Loading...
HomeMy WebLinkAboutMFP21003688.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP21003688 IVR Number: 21003688 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:08/02/2021Application Date:9202500310Parcel Number: 2602 NE 23RD PL Permit Type:08/02/2021Issue Date:Franchise Permit Work Class:08/02/2022Expiration Date:Minor Utility Job Number: 717757Franchise Type:Cable Description: Comcast to bore 154 LF in ROW and place 2" PVC. Pothole all existing utilities. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Fahm Saelee Prince Telecom Applicant Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Akisha Brown Prince Telecom Inc 551A Mews Dr New Castle, DE 19720 B: (302) 482-8893 C: (302) 482-8892 Contractor Business License Number: 29850Electrical Contractor: PRINCTL834BF Construction Contractor: PRINCTL862PS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP21003688 Scott Warlick 8/2/2021 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering Comcast Job 717757 2602 NE 23rd Pl Renton Monday Friday 8:00AM 3:00PM Bore 154'in r/w and place 2"PVC. Prince Telecom LLC 206 743 2173 Comcast Cable Communications Management, LLC rhonda_resnik@comcast.com 410 Valley Ave NW Ste:12 Bldg C Puyallup, WA 98371 MFP21003688 Scott Warlick CED 8/2/2021 DatePrepared By:Fahm Saelee 206-743- 2173 Rev Place Large Photo Detail Here CSG 717757 0 2602 NE 23rd Pl Renton, WA 98056 SOW Detail Overview Requesting to bore 154' in r/w and place 2" PVC. Begin at CATV ped SE corner of 2614's property bore 5' then bore 5' under sidewalk, bore 32' then bore 24' under driveway, bore 41' then bore 29' under driveway, bore 13' then bore 5' under sidewalk to private property. Utility crossing to be potholed to ensure required separation is maintained, locations to be identified at pre-con inspection. All substructure to have 36" cover. Date: ENGINEERED FOR:DROP BURY REVISION Comcast ESS CATV PED 5' ROW BORE 5' SWB32' ROW BORE 24' DWB 41' ROW BORE 29' DWB 13' ROW BORE 5' SWB MFP21003688 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS Maintain maximum space from fire hydrant. recommend boring under sidewalk to maintain space from fire hydrant Ne 23rd St SIGN SPACING = X (FEET) (1) FREEWAYS & EXPRESSWAYS RURAL HIGHWAYS RURAL ROADS RURAL ROADS and URBAN ARTERIALS RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED 55/70 mph 60/65 mph 45/55 mph 35/40 mph 25/30 mph 25mph or less 1500ft +/- 800ft +/- 500ft +/- 350ft +/- 200ft +/-(2) 100ft +/-(2) (1) All spacing may be adjusted to accomodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. CHANNELIZING DEVICE SPACING CHART (FEET) 50/70 35/45 20/30 mph *Half-Spacing*TAPER TANGENT 20 N/A 40 30 20 80 60 40N/A BUFFER DATALONGITUDINAL BUFFER SPACE = B SPEED (mph) LENGTH (ft)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS) STATIONARYOPERATION(ft) 30 MIN. 100 max. MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION 4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCELONGITUDINAL BUFFER SPACE = B ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED 10ft LANE 11ft LANE 12ft LANE L L L1/2L 1/2L 1/2L Lanewidth MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting SHOULDER TAPERS(assume 10ft shoulders) 1/3L Devices(FT)LengthMPH 2025303540455055606570 70105150205270450500550600650700 668810161415161719 355575105135225250275300325350 345569889910 75115165225295495550605660715770 679911181516181920 406085115150250285305330370385 3455698991011 80125180245320540600660720780840 6710912191618192122 406590125160270300330360390420 345561099101112 2025303540455055606570 2535507090150170185200220235 33344666677 Shoulder tapers equalsshoulder Width x Speed/3 MINIMUM TAPER LENGTH = L (feet) POSTED SPEED (mph) 25 30 35 40 45 50 55 60 65 70 105 115125 150165180 205 225245 270295 320 450495 540 500550 600 550605660 660 720 -----780 840 LANEWIDTH(feet) 10 1112 2602 2608 <32'>ROADWORKAHEADW20-1W20-7aW20-4100'ABC100'100'ONE LANEROADAHEADKENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOP KENNY STERTZTRAFFIC CONTROL SUPERVISORWashington Oregon ID# WA016416 743390((cones - flagger - NORTH NOT TO SCALE Prince telecom telecommunications installation Fahm Salee 206-743-2173 JOB # CSG717757 sidewalkplanter strip SIDEWALKCLOSED R9-9NOPARKING7 AM -6 PMFROMTO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T38 SIDEWALKCLOSED R9-9 NOPARKING7 AM -6 PMFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T38 NOTES -Minimum 10' Lanes -No Parking signs shall be placed 24hrs in advance of work -Sidewalk shall be closed -Spotter/Flagger will be onsite to help any Pedestrians get pass the work area 2614 Drive way bore <29'><41'>ROADWORKAHEADW20-1 W20-7aW20-4 100' A B C 100'100'ONE LANEROADAHEADcatvpedDrive way bore <24'><5'><13'>SWB<5'>SWB <5'>www.invarion.com MFP21003688