Loading...
HomeMy WebLinkAboutMFP21001630.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP21001630 IVR Number: 21001630 Permit Information Permit Name: ExteNet Systems - Fiber - SOUTH RENTON - PHASE 2 - SEG 11 Address/Location:04/16/2021Application Date:2193100010Parcel Number: 300 SW 27TH ST Permit Type:08/03/2021Issue Date:Franchise Permit Work Class:08/03/2022Expiration Date:Minor Utility Job Number: SOUTH RENTON - PHASE 2 - SEG 11Franchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013. EXTENET SOUTH RENTON PHASE 2 SEG 11 ROD & PROOF EXISTING CTL/LUMEN VAULTS AND CONDUIT ALONG WEST SIDE OF E VALLEY RD FROM JUST SOUTH OF SW 41ST ST TO SW 27TH ST. PLACE INNERDUCT & FIBER Contacts Name Address PhoneTypeBilling MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 2501 EAST VALLEY ROAD LLC 1717 MCKINNEY AVE #1900 DALLAS , TX 75202 Owner Rachel Fenton Extenet Systems LLC 3030 Warrenville Rd Lisle, IL 60532 Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP21001630 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 8/3/2021 NO.123PROJECT NAME: EXTENET RENTON - PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 16Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (SOUTH BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYEAST VALLEY RD101 SW 41ST STPARCEL NO.39268000404000 EAST VALLEY RDPARCEL NO.3123059032W20-1W20-5RW4-2RXXXWORK AREA 10'X10'WORKVEHICLEL2' MIN50'-100'MFP21001630 NO.123PROJECT NAME: EXTENET RENTON - PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 26Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYEAST VALLEY RDSW 41ST ST3751 EAST VALLEY RDPARCEL NO.12536000303900 EAST VALLEY RDPARCEL NO.3123059092TRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (SOUTH BOUND LANE)WORKVEHICLEL2' MIN50'-100'WORK AREA 10'X10'W20-1W20-5RW4-2RXXXW20-1X W20-5RW20-1MFP21001630 NO.123PROJECT NAME: EXTENET RENTON - PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 36Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYWORK AREA 10'X10'TRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG SW 34TH ST (EAST BOUND LANE)W20-1W20-5RW4-2RXXXWORKVEHICLEL2' MINSW 34TH STEAST VALLEY RD 3351 EAST VALLEY RDPARCEL NO.12538000303400EAST VALLEY RDPARCEL NO.30230590673401 EAST VALLEY RDPARCEL NO.1253600010W20-1W20-1MFP21001630 NO.123PROJECT NAME: EXTENET RENTON - PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 46Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE WITH LANE SHIFT (FOR URBAN ARTERIAL ROADWAY'S)WORKVEHICLEL/2W20-1W20-5RW4-2RXX2' MIN50'-100'XWORK AREA 10'X10'SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYEAST VALLEY RD3100 EAST VALLEY RDPARCEL NO.30230590703051 EAST VALLEY RDPARCEL NO.1253800034W20-1W20-5CW4-2LXXXCENTERLANECLOSEDAHEADL/2L/250'-100'W4-119R11' MINTRAFFIC CONTROL PLAN #4 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (SOUTH BOUND LANE)MFP21001630 NO.123PROJECT NAME: EXTENET RENTON - PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 56Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE WITH LANE SHIFT (FOR URBAN ARTERIAL ROADWAY'S)WORKVEHICLEL/2W20-1W20-5RW4-2RXX2' MIN50'-100'XWORK AREA 10'X10'SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYEAST VALLEY RDW20-1W20-5CW4-2LXXXCENTERLANECLOSEDAHEADL/2L/250'-100'W4-119R11' MINTRAFFIC CONTROL PLAN #5 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (SOUTH BOUND LANE)2915 EAST VALLEY RDPARCEL NO.1253800010PARCEL NO.3023059085R3-1W20-1X R3-1W20-1X MFP21001630 NO.123PROJECT NAME: EXTENET RENTON- PHASE 2 - SEG 11 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH STRENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 2 - PROOFING - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 66Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGENDNORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYWORK AREA 10'X10'WORKVEHICLEEAST VALLEY RD 300 SW 27TH STPARCEL NO.21931000102701 EAST VALLEY RDPARCEL NO.12538000152940 EAST VALLEY RDPARCEL NO.3023059096ROADWORKAHEADRIGHTLANECLOSEDAHEADCENTERLANECLOSEDAHEADW20-1W20-5CW4-2LXXXL/2L/250'-100'R20-5RW20-1X W20-1X R20-5RW4-119R2' MIN11' MINSHORT-TERM STATIONARY WORK ZONE - SINGLE-LANE CLOSURE WITH LANE SHIFT (FOR URBAN ARTERIAL ROADWAY'S)TRAFFIC CONTROL PLAN #6 - USE SET-UP WHERE APPLICABLE ALONG SW 27TH ST (EAST BOUND LANE)SW 27TH STMFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: R© 2021 Microsoft Corporation © 2021 TomTom SITE LOCATIONSHEET INDEXSCOPE OF WORK:PROOF EXISTING CTL/LUMEN VAULTS ANDCONDUIT ALONG WEST SIDE OF E VALLEY RDFROM JUST SOUTH OF SW 41ST ST TO SW27TH STKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 117ADDRESS: 300 SW 27TH ST, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS1.COVER SHEET / SITE LOCATION2.LEGEND3.GENERAL NOTES4.-16.DESIGN VIEWS A-M17.SITE PHOTOSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMNORTH SKY COMMUNICATIONS, LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C.206.305.5881MSMITH@NORTHSKY.COMSHEET 4SHEET 7SHEET 13SHEET 16SHEET 11SHEET 6SHEET 8SHEET 10SHEET 12SHEET 14SHEET 15SHEET 5SHEET 9MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 217#F#F#F##LEGENDMFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 317The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 417MATCH TO SHEET 5DESIGN VIEW A Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.EAST VALLEY RDSW 41ST ST 101 SW 41ST STPARCEL NO.39268000404000 EAST VALLEY RDPARCEL NO.312305903279' 36' 42' 8' 57' 14' 12'11' 23'11'CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12355'CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.1MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 517MATCH TO SHEET 6 MATCH TO SHEET 4DESIGN VIEW B Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.3751 EAST VALLEY RDPARCEL NO.12536000303900 EAST VALLEY RDPARCEL NO.312305909280'39'41'7'51'21'11'11'12'17'EAST VALLEY RDSW 41ST ST CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122130'241'CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.2MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 617MATCH TO SHEET 7 MATCH TO SHEET 5DESIGN VIEW C Know what'sbelow.before you dig.CallR3750 EAST VALLEY RDPARCEL NO.30230590823820 EAST VALLEY RDPARCEL NO.30230590923751 EAST VALLEY RDPARCEL NO.1253600030CONSTRUCTION NOTES2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2372'MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 717MATCH TO SHEET 8 MATCH TO SHEET 6DESIGN VIEW D Know what'sbelow.before you dig.CallREAST VALLEY RD3701 EAST VALLEY RDPARCEL NO.12536000203700 EAST VALLEY RDPARCEL NO.302305911778' 39'40' 10'47'21' 12'11'13'11'CONSTRUCTION NOTES2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.372'2MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 817MATCH TO SHEET 9 MATCH TO SHEET 7DESIGN VIEW E Know what'sbelow.before you dig.CallR3701 EAST VALLEY RDPARCEL NO.12536000203600 EAST VALLEY RDPARCEL NO.3023059104EAST VALLEY RD79' 39'40' 23'35'22' 11'13'11'CONSTRUCTION NOTES2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.372'2MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 917CONSTRUCTION NOTESMATCH TO SHEET 10 MATCH TO SHEET 8DESIGN VIEW F Know what'sbelow.before you dig.CallRSW 34TH ST80'39'41'22'35'22'12'23'EAST VALLEY RD3401 EAST VALLEY RDPARCEL NO.12536000103412 EAST VALLEY RDPARCEL NO.30230590272EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2372'MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1017MATCH TO SHEET 11 MATCH TO SHEET 9DESIGN VIEW G Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.EAST VALLEY RDSW 34TH ST3351 EAST VALLEY RDPARCEL NO.12538000303400 EAST VALLEY RDPARCEL NO.302305906782'41'41'25'34'23'11'13'11'80'45'35'22'43'16'11'12'11'10'CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.122223'114'29' 3 4 'CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.3MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1117CONSTRUCTION NOTESMATCH TO SHEET 12 MATCH TO SHEET 10DESIGN VIEW H Know what'sbelow.before you dig.CallR3351 EAST VALLEY RDPARCEL NO.12538000303400 EAST VALLEY RDPARCEL NO.3023059067SW 34TH STEAST VALLEY RD81'40'41'24'35'23'11'13'11'2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2371'MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1217MATCH TO SHEET 13 MATCH TO SHEET 11DESIGN VIEW I Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.EAST VALLEY RD3100 EAST VALLEY RDPARCEL NO.30230590703051 EAST VALLEY RDPARCEL NO.125380003482'41'40'25'35'22'11'13'11'CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12236'335'CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.4MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1317CONSTRUCTION NOTESMATCH TO SHEET 14 MATCH TO SHEET 12DESIGN VIEW J Know what'sbelow.before you dig.CallREAST VALLEY RD3001 EAST VALLEY RDPARCEL NO.1253800020PARCEL NO.302305909483'43'40'26'35'22'11'13'11'2CONSTRUCTION NOTES2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.372'MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1417CONSTRUCTION NOTESMATCH TO SHEET 15 MATCH TO SHEET 13DESIGN VIEW K Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.2915 EAST VALLEY RDPARCEL NO.1253800010PARCEL NO.3023059085EAST VALLEY RD83'43'40'26'35'23'11'13'11'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.139'233'122CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.5MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1517CONSTRUCTION NOTESMATCH TO SHEET 16 MATCH TO SHEET 14DESIGN VIEW L Know what'sbelow.before you dig.CallR83'43'40'26'35'23'12'13'11'EAST VALLEY RD2915 EAST VALLEY RDPARCEL NO.12538000102960 EAST VALLEY RDPARCEL NO.30230590982EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.2372'MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1617CONSTRUCTION NOTESMATCH TO SHEET 15DESIGN VIEW M Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #17 FOR SITE PHOTOGRAPHS.EAST VALLEY RDSW 27TH ST300 SW 27TH STPARCEL NO.21931000102701 EAST VALLEY RDPARCEL NO.12538000152940 EAST VALLEY RDPARCEL NO.302305909672'32'40'14'35'23'12'13'11'89'43'46'25'35'29'11'23'209'1EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.1213'CONTRACTOR NOTES1.BUTTERFLY TEMPLATES NEED TO BE FILLED OUT, SHOWINGCONDUIT ON ALL 4 WALLS. ADDITIONALLY, A PICTURE OF ALL4 WALLS OF EVERY MH IS REQUIRED.6MFP21001630 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 11NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 300 SW 27TH ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 11 - PROOFING PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRPHOTO #1: FACING NORTH ON WEST SIDE OF EAST VALLEY RDPHOTO #2: FACING NORTH ON WEST SIDE OF EAST VALLEY RDPHOTO #3: FACING WEST ON SOUTH SIDE OF SW 34TH STPHOTO #4: FACING SOUTH ON WEST SIDE OF EAST VALLEY RDPHOTO #5: FACING NORTH ON WEST SIDE OF EAST VALLEY RDPHOTO #6: FACING SOUTH ON NORTH SIDE OF SW 27TH STCONFIDENTIAL/PROPRIETARYSHEET: OF 17171EXISTING CTL/LUMEN VAULT. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK. AND TO CREATE FIELDBUTTERFLY DIAGRAMS.2EXISTING CTL/LUMEN CONDUIT. PULL JETLINE THOUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.1111122222222221MFP21001630