Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutMFP21003315.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP21003315
IVR Number: 21003315
Permit Information
Permit Name: Verizon - MCI
Address/Location:06/21/2021Application Date:2423049037Parcel Number: 1400 MONSTER RD SW
Permit Type:08/05/2021Issue Date:Franchise
Permit Work Class:08/05/2022Expiration Date:Major Utility
Job Number: 1807BDIO.74_UG_REN_90540Franchise Type:Telephone
Description: INSTALL 50 LF of (1) CONDUIT VIA TRENCH, (1) NEW VAULT, PULL (1) 4861 LF OF FIBER THROUGH PROPOSED
AND EXISTING CONDUIT, PROPOSED VAULT AND (6) EXISTING STRUCTURES
Contacts
Name Address PhoneTypeBilling
Henson Smith
Mastec Network Solutions Inc
Applicant
HOLLY NORTH
MGC TECHNICAL CONSTULTING, INC
8521 154th Ave NE
REDMOND, WA 98052
B: (206) 618-0651Applicant
MasTec Representative
MasTec
151 Stewart Rd SW
Pacific, WA 98047
Applicant
Matthew Sapp
Verizon - MCI
Contact
Louise Popelka
Verizon MCI Buisness
3245 158th Ave SE
Bellevue, WA 98008
B: (425) 240-0238Contact
Mastec Network Solutions Inc 22257 68th Avenue S
Kent, WA 98032
Contractor
Business License Number: 38949Construction Contractor: MASTENS876KN
Electrical Contractor: MASTENS863JS
VECTRA LLC 1400 MONSTER RD SW
RENTON , WA 98057
Owner
Amy Ledvina
Verizon - MCImetro
3245 158 Ave SE
Bellevue, WA 98008
H: (425) 505-5651Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MCIMETRO ACCESS TRANSMISSION SERVICES CORP.
1807BDIO.74_UG_REN_90540
Henson Smith
425.287.8701
henson.smith@mastec.com
1660 LONGACRES DR SW PANTHER LAKE TO TUKWILA GATEWAY
INSTALL 50 LF of (1) CONDUIT VIA TRENCH, (1) NEW VAULT,
PULL (1) 4861 LF OF FIBER THROUGH PROPOSED AND EXISTING CONDUIT, PROPOSED
VAULT AND (6) EXISTING STRUCTURES
50
MASTEC NORTH AMERICA, INC.425.287.8701
MASTENA991KJ 51687
06/21/21
Scott Warlick RESTORATION PER CITY OF RENTON STANDARDS
MFP21003315
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
8/5/2021
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.☐ A copy of the Traffic Control Plan (TCP) Application form.
2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
☐Include map(s) showing the location of the project and work area.
☐Be legible lettering and clear, contrasting, symbols of viewing or printing.
☐Must indicate street names, and north arrow and scale.
☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
☐Types of plans required:
☐Work hour plan – show all mobility impacts during construction hours.
☐Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
☐Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
☐Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
1807BDIO.74_UG_REN_90540
1660 LONGACRES DR SW
Monday Friday 8:00am 3:00pm
INSTALL 50 LF of (1) CONDUIT
VIA TRENCH, (1) VAULT, PULL (1) 4861 LF OF FIBER THROUGH
EX. and PROPOSED CONDUIT, VAULT AND (6) EX. STRUCTURES
MasTec North America 425 287 8701
Henson Smith henson.smith@mastec.com
151 Stewart Rd SW Pacific, WA 98047
MFP21003315
Scott Warlick CED 8/5/2021
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 11/25/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
•TCP must be approved prior to commencing the work, and all permit conditions shall be met.
•Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
•Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
•TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
•Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
•Approved Temporary TCP must be at the work site during work hours.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
Henson Smith 06/21/21
N
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
1 7
TCS STAMP:1807BDIO.75_UG_REN_90540COVER PAGETRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
TRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
MINIMUM SHOULDER TAPER LENGTH (L/3) (FEET)
Shoulder
Width
Feet
Posted Speed (mph)
10
25 30 35 40 45 50 55 60 65 70
40
40
40
60
60
90
90
90
120
150
130
170
150
190 200
8 160 170 190
240220
USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-grade
intersections and/or driveways.
9. A Traffic Control Supervisor is required for all work affecting
ROW.
TRAFFIC CONTROL PLAN COVER PAGE
CONSTRUCTION
CONTRACTOR:
MASTEC
MATTHEW SMITH
253-736-5107
MATTHEW.SMITH2@
MASTEC.COM
OUTSIDE PLANT
ENGINEERING:
MCI
BILL JENNESS
425-457-6852
WILLIAM.JENESS@
VERIZON.COM
ENGINEERING
CONTRACTOR:
MASTEC
GERALD LUKE
503-206-1280
GERALD.LUKE@
MASTEC.COM
5/19/2021 by:
MASTEC
253.886.3057Julian MoralesTCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
LONGACRES DIY
1400 LONGACRES DR SW
SW GRADY WAY 35MPH
OVERPASS
INTERSTATE
405
SW 16TH ST 25MPH
MH
MH
13'30'
15'
30'
ROADWORK
AHEAD
W20-1
ONE LANEROADAHEAD
W20-4
W20-7a
W20-7a
ONE LANEROADAHEAD
W20-4
ROAD
WORKAHEAD
W20-1
100'+-
100'+-
100'+-
50' TO 300'
100'+-
100'+-
100'+-
50' TO 100'
6 DEVICE MIN
13'
11'
ROAD
WORK
AHEAD
W20-1
100'+-100'+-
100'+-
105'
B
5'11'
11'
10'5'
LONGACRES DR SW 25MPH
MATCHLINESHEET 3MATCHLINESHEET 2100'+-
100'+-
KEEP
RIGHT
R4-7b
V
15'
75'
MONSTER RD SW 25MPH
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
2 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
& ONE LANE TWO WAY
W/ FLAGGERS
SHEET 2 TCP IS FOR
SHEET 5 & 6 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
Legend
Arrowboard (Chevron)
Cone
Flagger
Man Hole
V Vault
Work Area
Work Truck
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 115'100'20'40'
Plan Scale
1 : 600 (1'' = 50')
5/19/2021 by:MASTEC
253.886.3057
Julian Morales
TCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
15'
30'
ROAD
WORK
AHEAD
W20-1
RIGHT LANECLOSED
AHEAD
W20-5
W1-4 100'+-100'+-
100'+-
105'
B
5'11'
11'
10'5'MATCHLINESHEET 2PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
3 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
& ONE LANE TWO WAY
W/ FLAGGERS
SHEET 3 TCP IS FOR
SHEET 5 & 6 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
Legend
Arrowboard (Chevron)
Cone
Flagger
Man Hole
Sign Stand
Work Area
Work Truck
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 105'100'20'40'
Plan Scale
1 : 600 (1'' = 50')
5/19/2021 by:MASTEC253.886.3057
Julian Morales
TCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
SW 16TH ST 25MPH
MH
16'
35'
12'
W1-4
ROAD
WORKAHEAD
W20-1
RIGHT LANECLOSEDAHEAD
W20-5
100'+-100'+-100'+-115'B
ROAD
WORK
AHEAD
W20-1
KEEP
RIGHT
R4-7b
5'
11'
12'
11'
5'
100'+-100'+-
S
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
4 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
SHEET 4 TCP IS FOR
SHEET 7 & 8 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 115'100'20'40'
SPOTTER SHALL ASSIST PEDESTRIAN'S
AROUND THE WORK AREA AT ALL TIMES.
1412 SW 16TH ST
1300 SW 16TH ST
Legend
Cone
Man Hole
Sign Stand
Spotter
Work Area
Work Truck
Plan Scale
1 : 600 (1'' = 50')5/19/2021 by:
MASTEC
253.886.3057
Julian Morales
TCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
SW 16TH ST 25MPH SW 16TH ST 25MPH
MH
OAKESDALE AVE SW 35MPH
15'
35'
14'
13'
15'
KEEP
RIGHT
R4-7b
1120 SW 16TH ST
S
R3-2
ROAD
WORK
AHEAD
W20-1
ROADWORKAHEAD
W20-1
ROAD
WORK
AHEAD
W20-1
CENTER
LANECLOSEDAHEAD
W9-3
ROAD
WORK
AHEAD
W20-1
RIGHT LANECLOSED
AHEAD
W20-5W1-4
100'+-100'+-100'+-125'B
100'+-
100'+-
12'
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
5 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
SHEET 5 TCP IS FOR
SHEET 11 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 115'100'20'40'
SPOTTER SHALL ASSIST PEDESTRIAN'S
AROUND THE WORK AREA AT ALL TIMES.
SPOTTER SHALL ASSIST VEHICLES
IN AND OUT OF ACCESS POINTS
Legend
Cone
Man Hole
Spotter
Traffic Light
Work Area
Work Truck
Plan Scale
1 : 600 (1'' = 50')
5/19/2021 by:
MASTEC
253.886.3057Julian MoralesTCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
SW 16TH ST 25MPH
SW 16TH ST 25MPH
RAYMOND AVE SW 25MPH
MH
35'
15'
14'
13'
15'
DETOUR
M4-9
800 SW 16TH ST
S
KEEP
RIGHT
R4-7bR3-2
ROAD
WORK
AHEAD
W20-1
ROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1
CENTERLANE
CLOSED
AHEAD
W9-3
RIGHT LANECLOSED
AHEAD
W20-5W1-4
100'+-100'+-
100'+-100'+-100'+-125'
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
6 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
SHEET 6 TCP IS FOR
SHEET 12 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
Legend
Cone
Man Hole
Sign Stand
Spotter
Work Area
Work Truck
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 115'100'20'40'
SPOTTER SHALL ASSIST PEDESTRIAN'S
AROUND THE WORK AREA AT ALL TIMES.
SPOTTER SHALL ASSIST VEHICLES
IN AND OUT OF ACCESS POINTS
Plan Scale
1 : 600 (1'' = 50')
5/19/2021 by:
MASTEC
253.886.3057Julian MoralesTCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
LIND AVE SW 25MPH
SW 16TH ST 25MPH
MH
15'
35'
12'
11'
10'
ROADWORKAHEAD
W20-1
ROAD
WORK
AHEAD
W20-1
ROAD
WORKAHEAD
W20-1
ROAD
WORK
AHEAD
W20-1W4-2
RIGHT LANECLOSEDAHEAD
W20-5
ROAD
WORK
AHEAD
W20-1
100'+-100'+-100'+-105'B
316 SW 16TH ST
S
PROJECT ID NUMBER
1807BDIO.75_UG_
REN_90540
PERMITTING ENTITY
PROJECT LOCATION
SCOPE OF WORK:
DRAWN BY:
DATE:
SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON
1400 LONGACRES DR SW
JM
5/19/2021
7 7
TCS STAMP:1807BDIO.75_UG_REN_90540RIGHT LANE CLOSURE
SHEET 7 TCP IS FOR
SHEET 14 OF 15 OF SITE
WORK PLANS.TRAFFIC CONTROL PLANTRAFFIC CONTROL PLAN:
SHORT DURATION WORK ZONE FOR
EXISTING UNDERGROUND CONDUIT INSTALLATION
All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard
Legend
Arrowboard (Chevron)
Cone
Man Hole
Spotter
Traffic Light
Work Area
Work Truck
N
MPH TAPER SIGN SPACING TAPER TAGENT
SHIFT TAPER = 1/2 TAPER
SHOULDER TAPER = 1/3 TAPER
25 105'100'20'40'
SPOTTER SHALL ASSIST PEDESTRIAN'S
AROUND THE WORK AREA AT ALL TIMES.
SPOTTER SHALL ASSIST VEHICLES
IN AND OUT OF ACCESS POINTS
Plan Scale
1 : 600 (1'' = 50')5/19/2021 by:MASTEC
253.886.3057
Julian Morales
TCS # 012813Jʅʙiʋɚ Mʝrɪȵeɡ
www.invarion.com
MFP21003315
MCImetro
ACCESS TRANSMISSION SERVICES, CORP
OUTSIDE PLANT CONSTRUCTION
RENTON, WASHINGTON
UNDERGROUND FIBER INSTALLATION
RIGHT-OF-WAY PERMIT
4,861 FEET OF FIBER PULL THROUGH EXISTING CONDUIT, 50 FEET OF TRENCH, 1 NEW VAULT, AND 6 EXISTING STRUCTURES
MCI PERMIT NUMBER: 1807BDIO.74_UG_REN_90540
SITE SPAN NFID: 1807BDIO.74
CAPITAL PROJECT: 072443-001
CENTRAL RENTON TO TUKWILA GATEWAY
ENGINEERING SERVICES
MFP21003315This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE VERT:
DRAWN BY:MCI METROACCESS TRANSMISSION SERVICES, CORP.REVISIONS
DATE DESCRIPTION INITIALS
BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
SHEET 02 OF
NAME OF FIRM: MASTEC NORTH AMERICA
CONSTRUCTION MANAGER: MATTHEW SMITH
PHONE: (253)-736-5107
EMAIL: MATTHEW.SMITH@MASTEC.COM
CONTACTS SHEET INDEX
ENGINEERING CONTRACTOR
OWNERS
CONSTRUCTION CONTRACTOR
JURISDICTION SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540CITY: RENTON
PHONE: (425) 430-6400
STREET: 1055 S GRADY WAY
CITY STATE ZIP: RENTON, WASHINGTON 98057
MCI METRO ACCESS TRANSMISSION SERVICES, CORP
COMPANY REP: BILL JENNESS
PHONE: (425) 457-6852
EMAIL: WILLIAM.JENNESS@VERIZON.COM
01
02
03
05-14
15
04
COVER SHEET
VICINITY MAP, CONTACTS & SHEET INDEX
GENERAL NOTES
SITE PLAN
LEGENDNAME OF FIRM: MASTEC NORTH AMERICA
PROJECT MANAGER: GERALD LUKE
PHONE: (503)-206-5423
EMAIL: GERALD.LUKE@MASTEC.COM
LOCATION OVERVIEW KEY MAP
DATE:
0 750 1,500375Feet
City of Renton, County of King, Bureau of Land Management, Esri Canada, Esri, HERE, Garmin, INCREMENT P, USGS, EPA, USDA
© 2021 Microsoft Corporation
© 2021 TomTom
END
BEGIN 316 SW 16TH
STREET
1660-1600LONGACRES DR
SW
SHEET #5
SHEET #6 SHEET #7 SHEET #8 SHEET #9 SHEET #10 SHEET #11 SHEET #12 SHEET #13 SHEET #14
NAME OF FIRM: MASTEC NORTH AMERICA
CONSTRUCTION MANAGER: JUAN FORONDA
PHONE: (253)-266-4037
EMAIL: JUAN.FORONDA@MASTEC.COM
PERMITTING CONTRACTOR 15 TYPICAL
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
OF03 15
ENGINEER:
GENERAL NOTES
THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANY
RESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREA COVERED BY
THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO AS CERTAIN THE LOCATION OF UNDERGROUNDUTILITIES PRIOR TO PERFORMING ANY EXCAVATION.
ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITEWORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTION REGULATIONS AND
APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE
SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHINPUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE LOCAL JURISDICTION INSPECTOR.
INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/
OWNER.
1.
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS
SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE,
MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE.THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO
REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND
ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED
IMPROVEMENTS SHOWN ON THESE PLANS.
2.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES.
THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OFANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.
3.
THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITY COMPANIES
WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT
THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTORSHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.
4.
THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE
STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THEJOB ON-SITE AT ALL TIMES.
5.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,
TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.
6.
IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN
THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.
7.
CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.17.
ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED
EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.
16.
ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCALJURISDICTION ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.15.
ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF
CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN
GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZEDWITH HARD SURFACE OR LANDSCAPING.
14.
DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR
ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD
DRAWINGS.
13.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD
DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT
ALL TIMES.
12.
PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR
OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.
11.
ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS
SPECIFICALLY STATED OTHERWISE.8.
FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTOR SHALLSUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY
CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION APRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCAL JURISDICTION.
9.
THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OFTHE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED,
CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.
10.
RENTON
UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PHYSCIALLY
LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALL
INSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.
1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET THE CITY OF RENTON STANDARDS.
ALL RENTON STANDARD DRAWINGS AN BE FOUND AT THE FOLLOWING WEBSITE: https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637032.
ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -
SECTION F 110.0-110.2.
3.
ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 102.0.
ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARDDETAIL - SECTION F 103.0.
4.
5.
6.
9/4/2020
HK
DV
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
OF04 15
ENGINEER:
LEGEND
PROPOSED
EXISTING VERIZON
BASE LAYERS
EXISTING UTILITIES
PROPOSED SYMBOLS EXISTING MCI SYMBOLS
A A APROPOSED AERIAL STRAND
DIRECTIONAL BORE
TRENCH
A A A
³MIC
!!!!!!!!!
EXISTING AERIAL STRAND
EXISTING UNDERGROUND
1_2" HDPE
2_2" HDPE
1_4" HDPE
1_2" PVC
2_2" PVC
1_4" PVC
INNERDUCT
!!!!!!!!!!!!!!
"""""""""""""""""""""
PIL
) ) ) ) ) ) ) ) ) ) ) ) ) ) )
SIDEWALK
EDGE OF PAVEMENT
FACE OF CURB
FENCE
GUARDRAIL
LIP OF GUTTER
PROPERTY LINE
RAILROAD
RIGHT OF WAY
CENTERLINE
T T
³³E E
G G
TELECOMMUNICATIONS
ELECTRIC
GAS
RAINWATER
SANITARY SEWER
STORM DRAIN
WATER
EXISTING UTILITIES SYMBOLS
PROPOSED MANHOLE
PROPOSED VAULT
PROPOSED ANCHOR
PROPOSED GUY
PROPOSED SIDEWALK ANCHOR & GUY
PROPOSED RISER
POTHOLE
BORE PIT
EXISTING MCI MANHOLE
EXISTING MCI VAULT
EXISTING MCI ANCHOR
EXISTING MCI GUY
EXISTING MCI SIDEWALK ANCHOR & GUY
EXISTING MCI SPLICE
POWER PEDESTAL
POWER HANDHOLE
POWER CABINET
POWER VAULT
POWER UNKNOWN
POWER MANHOLE
POWER POLE
STREET LIGHT POLE
STREET HANDHOLE
TRAFFIC SIGNAL HANDHOLE
TRAFFIC SIGNAL VAULT
TRAFFIC SIGNAL MANHOLE
TRAFFIC CABINET
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL PEDESTAL
CATV MANHOLE
CATV HANDHOLE
CATV PEDESTAL
TELECOM MANHOLE
TELECOM HANDHOLE
TELECOM CABINET
POWER ANCHOR
POWER GUY
POWER SIDEWALK GUY
PEDESTAL (UNKNOWN UTILITY)
WATER SAMPLING STATION
OTHER UNKNOWN
SEWER VAULT
SEWER UNKNOWN
STORM DRAIN VAULT
SEWER VALVE
STORM ACCESS POINT
TELECOM PEDESTAL
TELECOM POLE
SEWER MANHOLE
SEWER CLEANOUT
SEWER CATCH BASIN
STROM CATCH BASIN
STORM MANHOLE
STORM DRAIN UNKNOWN
STORM CLEANOUT
STORM DRAIN VALVE
WATER VALVE
WATER METER
WATER RESERVOIR
WATER MANHOLE
WATER VAULT
WATER UNKNOWN
WATER WELL
MANHOLE (UNKNOWN UTILITY)
WATER PUMP
TEST VALVE
GAS METER
GAS VALVE
GAS MANHOLE
FIRE HYDRANT
GAS TEST POINT
TRAFFIC LOOP DETECTOR
TRAFFIC DETECTOR
BOLLARD
SIGN POST
PARKING METER
CULVERT
ADA RAMP
ADA RAMP COMPLIANCE
SUB STATION
TRANSIT STOP
TREE
CABLE MARKER
9/4/2020HK
DV
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET:SEE SHEET:SEE SHEET:6SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 155""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&&&&&
___
_
_
_
S
T
A
3
+
3
7
(
2
4
'
L
T
)
CONSTRUCTION NOTES
GENERAL NOTES
LOCATE MANHOLE AND PULL FIBER CABLE THROUGH
CONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
CONTRACTOR TO CONFIRM AND
MAINTAIN CLEARANCE OFSTRUCTURES
______STA 4+55 (21' LT)
EXISTING XO CONDUITCONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTIONPULL FIBER CABLE THROUGH
DIG BORE PIT AND PL. NEW
36"X60"X48" VAULT IN
SIDEWALK. SEE DETAIL ON
PAGE 15
³MIC
³MIC ³MIC³MIC
12 '3 '
62 '26 '43 '28 '5 '22 '
0+00
1+00
1+00
2+00
3+00
4+00
5+00
EXISTING
C
O
N
D
U
I
T
2
3
3
2
4
4
1
1
3
SW 16T
H
S
TJACKSON AVE SWJACKSON AVE SWJACKSON AVE
SW
SW GRAD
Y
W
A
Y
SW GRAD
Y
W
A
Y
SW GRAD
Y
W
A
Y
I-405 FW
Y
I-405 FWY
I-405 FWY
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 5SEE SHEET:SEE SHEET:7SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 156&&
STA 2+79(24' LT)______
CONSTRUCTION NOTESGENERAL NOTES
EXISTING MCI CONDUITCONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
LOCATE MANHOLE AND PULL FIBER CABLE THROUGHCONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION
CONTRACTOR TO CONFIRM AND
MAINTAIN CLEARANCE OF
STRUCTURES
STA 0+00 IS LOCATED AT
INTERSECTION OF SW 16TH ST AND
JACKSON AVE SW ³MIC³MIC³MIC³MIC³M IC ³MIC 3 '45 '21 '16 '5 '2+00
3+00
4+00
5+00
6+00 7+00
532'
EXISTING C
O
N
D
U
I
T
EXISTING CONDUIT
3
2
32
SW GRAD
Y
WAY
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
I-405 FW
Y
SW 16T
H
S
T
SW 16TH
S
T
SW 16TH ST
SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 6SEE SHEET:SEE SHEET:8SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 157&&_____
_
S
T
A
8
+
0
4(
3
9'
L
T
)
CONSTRUCTION NOTES
GENERAL NOTES
LOCATE MANHOLE AND PULL FIBER CABLE THROUGH
CONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION
CONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED ATINTERSECTION OF SW 16TH ST ANDJACKSON AVE SW
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH ³MIC³MIC³MIC³MIC15 '79 '43 '50 '24 '40 '17 '11 '6+00 7+00 8+00 9+00 10+00 11+00
532'
EXISTING CONDUIT
EXISTING CONDUIT2102'
1302SW 16TH ST
3
2
2
3
SW 16TH ST SW 16TH ST SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 7SEE SHEET:SEE SHEET:9SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 158&CONSTRUCTION NOTESGENERAL NOTES
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
CONTRACTOR TO CONFIRM AND
MAINTAIN CLEARANCE OF
STRUCTURES
STA 0+00 IS LOCATED AT
INTERSECTION OF SW 16TH ST AND
JACKSON AVE SW ³MIC³MIC78 '43 '46 '18 '36 '17 '11 '11+00 12+00 13+00 14+00
15+00
16+00
EXISTING CONDUIT EXISTING CONDUIT(2102')
1302SW 16TH ST
3
3
SW 16TH ST SW 16TH ST
SW 16TH ST
SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 8SEE SHEET:SEE SHEET:10SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 159
"""""""""""""""""""""
""""""""""""""""""""""""
"""""""""""""""""""""
"""
""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&CONSTRUCTION NOTES
GENERAL NOTES
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
CONTRACTOR TO CONFIRM AND
MAINTAIN CLEARANCE OF
STRUCTURES
STA 0+00 IS LOCATED AT
INTERSECTION OF SW 16TH ST AND
JACKSON AVE SW ³MIC³MIC³MIC60 '30 '12 '45 '23 '19 '4 '16+00 17+00 18+00 19+00 20+00 21+00
EXISTINGCONDUIT
EXISTING
CONDUIT EXISTING CONDUIT(2102')
3
3 OAKESDALE AVE SWOAKESDALE AVE SWSW 16TH ST SW 16TH ST SW 16TH ST SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 9SEE SHEET:SEE SHEET:11SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 1510&&CONSTRUCTION NOTESGENERAL NOTES
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
CONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED ATINTERSECTION OF SW 16TH ST ANDJACKSON AVE SW
LOCATE MANHOLE AND PULL FIBER CABLE THROUGHCONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION
_____
_
S
T
A
2
1
+
3
7
(
2
6'
L
T)³MIC³MIC³MIC61 '41 '32 '20 '25 '5 '8 '21+00 22+00 23+00 24+00 25+00 26+00
EXISTING CONDUIT EXISTING CONDUIT EXISTING CONDUIT(2102')
3
3
2
2
SW 16TH ST SW 16TH ST SW 16TH ST SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 10SEE SHEET:SEE SHEET:12SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 1511&&_____
_
S
T
A
2
9
+
0
8(
2
1'
L
T)
CONSTRUCTION NOTESGENERAL NOTES
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTION
PULL FIBER CABLE THROUGH
CONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED ATINTERSECTION OF SW 16TH ST ANDJACKSON AVE SW
LOCATE MANHOLE AND PULL FIBER CABLE THROUGH
CONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION³MIC³MIC³MIC1 '61 '41 '35 '20 '21 '2 '14 '26+00 27+00 28+00 29+00 30+00
(2102')
EXISTING CONDUIT EXISTING CONDUIT EXISTING CONDUIT1214'
3
3
2
2
SW 16TH ST SW 16TH ST SW 16TH ST
RAYMOND AVE SWRAYMOND AVE SWHK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 11SEE SHEET:SEE SHEET:13SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 1512&CONSTRUCTION NOTESGENERAL NOTES
CONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED ATINTERSECTION OF SW 16TH ST ANDJACKSON AVE SW
EXISTING MCI CONDUIT
CONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTIONPULL FIBER CABLE THROUGH ³MIC³MIC³MIC61 '38 '33 '17 '25 '8 '9 '30+00 31+00 32+00 33+00 34+00 35+00
EXISTING CONDUIT
EXISTING CONDUIT(1214')
1602RAYMONDAVE SW
3
3
SW 16TH ST SW 16TH ST SW 16TH ST SW 16TH ST
RAYMOND AVE SWRAYMOND AVE SWHK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 12SEE SHEET:SEE SHEET:14SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 1513&CONSTRUCTION NOTES
EXISTING MCI CONDUITCONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTIONPULL FIBER CABLE THROUGH
GENERAL NOTES
CONTRACTOR TO CONFIRM AND
MAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED AT
INTERSECTION OF SW 16TH ST ANDJACKSON AVE SW ³MIC³MIC³MIC89 '43 '46 '18 '28 '12 '17 '35+00 36+00 37+00 38+00 39+00
(1214')
EXISTING CONDUIT
EXISTING CONDUIT
500SW 16TH ST
3
3
SW 16TH ST SW 16TH ST SW 16TH STSENECA AVE SWHK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: RENTON, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
0 40FeetSEE SHEET: 13SEE SHEET:SEE SHEET:SEE SHEET:BOM / CLARIFICATIONS
DESCRIPTION QUANTITY
OF 1514&&_____
_
S
T
A
4
1
+
0
8(
3
6'
L
T)
SEE PERMIT 1807BDIO.74_UG_REN_90539
CONSTRUCTION NOTES
EXISTING MCI CONDUITCONTRACTOR TO VERIFY CORECT CONDUIT PRIOR TO CONSTRUCTIONPULL FIBER CABLE THROUGH
GENERAL NOTES
CONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OFSTRUCTURES
STA 0+00 IS LOCATED ATINTERSECTION OF SW 16TH ST ANDJACKSON AVE SW
LOCATE MANHOLE AND PULL FIBER CABLE THROUGHCONTRACTOR TO VERIFY CORRECT MANHOLE PRIOR TO CONSTRUCTION
³MIC³MIC³MIC4 '55 '24 '35 '9 '38+00 39+00 40+00 41+00
EXISTING CONDUIT
EXISTING CONDUIT (1214')
316SW 16TH ST
500SW 16TH ST
3
3
2
2
LIND AVE SWLIND AVE SWSW 16TH ST SW 16TH ST SW 16TH ST
HK
9/4/2020
MFP21003315
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN PERMISSION.
SHEET
SCALE VERT:
DRAWN BY:
DATE:MCI METROACCESS TRANSMISSION SERVICES, CORP.SITE NAME: WARE-PANTHER LAKE TO TUKWILA GATEWAYLOCATION ADDRESS: 1660 LONGACRES DR SWHUB: WALB HUB ADDRESS: TUKWILA, WASITE SPAN NFID: 1807BDIO.74MASTEC ID NUMBER: 1807BDIO.74_UG_REN_90540REVISIONS
DATE DESCRIPTION INITIALS
OF15 15
ENGINEER:
DETAILS
HK
9/4/2020
MFP21003315