HomeMy WebLinkAboutS-40720414: DocuSign Envelope ID: 6EECF5B6-602A-4E4A-8436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 0 2', 4', 9', 12", OR 24" l< ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EOUALLYI, SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION #3 BAR EACH CORNER #3 BAR EACH SIDE TOP AND BOTTOM - 03 BAR EACH CORNER 18" (MIN. 43 BAR HOOP / - e I L G I / ONE #3 BAR ACROSS BOTTOM PRECAST BASE SECTION SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION UR PUBLIC WORKS DEPARTMENT PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12, ALL METAL PIPE 15" CPSSP', STD. SPEC. 9-0520 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15, PROFILE WALL PVC, STD.. SPEC. 9415.12(2) 15' *CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05. M9)I, OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS, AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED, 2, THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 19. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5- MAXIMUM. PROVIDE A 1.5• MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5' - 4. THE FRAME AND GRATE SHALL BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY RAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER 6. THE STRUCTURE OPENING DIMENSIONS SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-21) 3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10, FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH, 11, ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING I$ NOT TO SCALE (NTS) STD. PLAN - 2D0.30 ATPROVED� CONCRETE INLET GAZ 9/28/2018 1 DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 UNDISTURBED NATIVE VEGETATION UNDISTURBED NATIVE SOIL 3"-4' ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 3"OF COMPOST INCORPORATED INTO 5" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8"J PLANTING BEDSIUNDISTURBED UNDISTURBED TURF (LAWN) AREAS, VEGETATION, SEE NOTE 1 SEE NOTE 1 0 OPTION 1 - NO DISTURBANCE PLANTING BEDS TURF (LAWN) AREAS GRASS: SEED OR SOD UNDISTURBED NATIVE SOIL GRASS: SEED OR SOD 1.75" OF COMPOST INCORPORATED INTO 6.25" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9. 5, FOR A SETTLED DEPTH OF II :45 AP SUBSOIL SCARIFIED 4' BELOW SUBSOIL SCARIFIED 4" BELOW '��// / ;�I. COM POST AMENDED LAYER COMPOST AMENDED LAYER -�'.� � - -F (1 T BELOW SOIL SURFACE) (12' BELOW SOIL SURFACE) --I 12, OPTIONS 2,3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND PLANTING BEDS TURF (LAWN) AREAS 7-4-ARBORIST I I li WOOD CHIP /' II /I'f,ll� III}ii,1, GRASS: SEED OR SOD MULCH, SEE STD. D• lid PLAN 262.60 _ NOTES: 1, AREAS OF NO DISTURBANCE TO BE FENCED AND EXISTING VEGETATION AND SOIL TO BE I I PROTECTED FROM CONSTRUCTION IMPACTS. 6" IMPORTED � TOPSOIL MI % IF I I- I- ITT- - TOPSOIL MIX I �I I -1 GENERAL NOTES: A4 (cgPAcrEo I I I - I I•- I I II II- I I -- (COMPACTED DEPTH) 6" 1�11II II Ii (III III DEPTH] 1TO MEASURE SETTLED DEPTH, WATER SOIL SUFFICIENTLY TO FULLY SATURATE WITHOUT CAUSING EROSION _ I /J%.` -1 / • SUBSOIL IS 2. COMPOST TO MEET STD. PLAN 262.60. �j�, SUBFIED6" '^r , \� SCARIFIED 8" \!`/ / BELOW IMPORTED 3. COMPACTION OF TOPSOIL (WHERE REQUIRED) SCARIFIED 6' _ •.� ? - \ �. TOPSOIL MIX TO BE TO 85%OF STANDARD PROCTOR. BELOW IMPORTEDTOPSOIL MIX 4, SEE CONSTRUCTION PLANS FOR SPECIFIC 12' I PROJECT REQUIREMENTS. OPTION S - IMPORTED TOPSOIL UNLESS OTHE R W 15E NOTED, DRAWING IS MOTTO SCALE (NTS) STD. PLAN - 264.00 PUBLIC WORKS APPR D; SOIL AMENDMENT SECTIONS GAZ 9/28/2018 1 , DEPARTMENT DATE Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 ■ Phone: (425) 392-0250 ■ Fax: (425) 391-3055 Eastern Washington Division 407 Swiftwater Blvd. ■ Cie Elum, WA 98922 ■ Phone: (509) 674-7433 ■ Fax: (509) 674-7419 :45 M 1 CATCH BASIN FRAME AND VANED GRATE PER STD- PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYR), SEE NOTE 5 4' MIN. 28" MAX. 16, MAX. FLAT SLAB TOP 72', Ia', 54",0' 4" 98", 120' OR 144" C SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER L- �o MIN. "q" RING' Z' 2.5- MAX. REINFORCING STEEL, (TYP.) MIN- 12-MAX. 1Z- GRAVEL BACKFILL FOR PIPE ZONE 12' BEDDING PER WSDOT STD. SPECIFICATION SECTION 9.03.12(3) s" s• SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES- 1- NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AMC GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2' MINIMUM TO 25" MAXIMUM. PROVIDE A 1-5' MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9.04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE - 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. S. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 4r' 4.. 6" 1. 8.1 4.5" 8• 42" 8" a%' S' 8' 48" a" 72' 6' 81 50, 12' 84- 8• 12- T2• 12' OW 1 8' 12, 84' 12' 120" 10^ IT 1. 12' 1"" 12" 12" 106, 12' PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL GPS5P' SOLO WALL PVC' PROFILE WALL PVC' 1. 24' 3T 24' 30• 1. 1. 1. 36" 3D, 36, 1. 1. 1. 42' 36' 42' 42" 72" 42" 54" AT 48" 48" 84• 1. BO• 54' 48' 48" 96" 60• 7T 60' 48' 1 48" 12T 1. 84" 60, 1 48' 1 48" 144' 1. 96, 60' 1 48' 1 48- 'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-DS-20) 'ETD. SPEC. 9-05.120) 'STD. SPEC. 9-05.12(2) UNLESS OTHERWISE NOTED, DRAWING I$ NOT TO SCALE (NTS) STD. PLAN - 201.00 AOWI%6 R. PUBLIC WORKS CATCH BASIN TYPE 2 PR U DEPARTMENT GAZ 9/28/2018 DATE SHACKLE RODS TYPE A BLOCKING � s J TYPE 8 CONCRETE BLOCKING FOR VERTICAL STD. PLAN - 330.3 PUBLIC WORKS FITTINGS DEPARTMENT 8 MARCH 2O10 �e 39374 IST � � 1 AS-BUILTS S�IONaL N0. 0311912021 REVISION :45 A M.d 34" FLAT FACE GOTHIC p00 9" DIA 5 �� 0 STORM 0 4" ❑0O0 0❑ "MD DIA 4,15* 0-112" D(2) "! l6 SS SOCKET HEAD CAP DIA (1)OPEN PICKHOLE I.. SCREW (ALLENHEAD) WIWSHRS ON A 8' DIA BOLT CIRCLE PLAN VIEW FRAME SECTION CAST IRON FRAME AND COVER, SEE NOTE 3 - 8' CLASS Aqg� SPHALT. SEE NOTE 4 CLEANOUT RISER, SEE NOTE 2 8-13l16' DIA PAVED AREA (TYP. ) 12- EXTEND CLEANOUT RISER 7 ABOVE DESIGN PONDING ELEVATION OR PER PLAN FERNCO GASKETED QUIK CAP OR SIMILAR DESIGN MINDING ELEVATION 4" STREA.MBED COBBLES PER WSDOT 9A3.11(2) 4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03-12(4) SOIL TIGHT 45'BEND WYE SOIL TIGHT COUPLER �{{\ UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR "'•3'l, ROOF DRAIN COLLECTOR 'i•1 PIPE. SEE NOTE 7 TOOVERFLOW-- STRUCTUREOR - STORM MAIN \ v ` MECHANICAL PLUG OR CONTINUED CONNECTOC TYPICAL CLEANOUT CONFIGURATION CLEANOUT RISER, SEE NOTE 2 - CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDINO AREA NOTES- 1. DIAMETER TO BE &INCHES MINIMUM PRIVATE. &INCHES MINIMUM PUBLIC- UNDERDRAIN PIPE PER STO. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME SIZE AND MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCT NO 00367549BOI OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT. MARKED'STORM'- 4, FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF SIORETENTION MINDING AREA. POUR 8" THICK, 2'xZ SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR. AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE. AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF SIORETENTION MINDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, U NLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING I$ NOT TO SCALE (NTSI D. PLAN - I26.00 URJPUBLIC WORKS AaPRovcO DEPARTMENT STORM SYSTEM CLEANOUT GAZ 9/28/2018 1 DATE f1".-V.I�II f-INMt.1mID I L. - -• _ _ =L h L I; .!-_ MA!L�I'_1.L _ .:t-0:. =H:L E I'. I �L L' --.`. nr --1- --n . .. L-n1 SURVEYED: SDM DESIGNED: EDM DRAWN: TLK EDM 03119121 SDM CHECKED: EDM BY DATE APPR APPROVED: NEM L r :45 AI --HI.• ��•RLrM'�Z SAN ITARY'1R APVHOU SN�4 �'.► G V-11/2011 1 :12 #q .L - - - OWN Know what's below. Call before you dig. VERTICAL NAVD1988 CITY OF N.T. $ HORIZONTALNAD 1983/1991 V ] RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY 0 0) `l IN COMPLIANCE WITH CITY OF RENTON STANDARDS o SAPPHIRE ON TALBOT CONSTRUCTION DETAILS co Q z 0 L^Wr/ = DATE 0311912021 CA - CA - (JJ FIELDBDGK: N/A PAGE NIA DRAWING NO: 18615 SHEET: OR 18 19 R-407217