Loading...
HomeMy WebLinkAboutR-413107T C TM T `- , T I I N I CV LU U_ 'LU V ) LU IIr H J LU O n D Q 72 �.63 D - f. 6 2 .59 .6z- 65_- UGP 22:35 22.60 -------- ° 22.48---------- ° --= ° 22_64 ----- ------------------ a / � D 5� v I 22.7°E�' \ VI D \ I 22.73 I I 6"PVC SSCO iI / I I _L � ti5 I I 23.071 a NX z "2 \\ \\\\ .. ®22.75D 3"PVC SSCO Rol 01 i�l■ivliV�ll�ii■■■■■■�:�� 22.35 101 Asa::.�������F7�1i■■■■I�T�i 'i■■■■■■ 3"PVC SSCO 0 P- T 22.08 / 07 I 1 1 6'5" IqEXTENDING A 15 FT WIDE EASEMENT, 7.5 FT FROM THE PIPE CENTERLINE, _ SHALL BE REQUIRED. 10 LF 4" DI CL 52 (RJ) P II I (1) 4" 90° BEND (RJ) W/ THRUST BLOCKING ❑ H20 H20 PER COR STANDARD DETAIL 330.2 (TYP) I UGP 30 LF' 4" DI CL 52 (RJ) \ .Q vD 22.89. .89 2T 79 2 .87 �P3� \, INSTALL POWER TO J' L Aw Q 39871 Cs EGISTER� �IDNAL E� 0 /10 N 0. in FRTS 22. 22.33 2172 6 \ \ \ 1 / 22.40 1 22.46 22.38 22.88 / R S 23. 2 Q 1.0 II / 21.2�ffi II 22.52 / I a 1 / Q 21 ji 01 �23.05 21. / 1 1 O-INCH DUCTILE IRON 1.10 WATER MAIN I 11 2105 -� 0 I II X / �SS1- 2C.89 I I T � I 1�0,;I( ¢- - POST INDICATOR V VF (1) 4" DDCVA PER COR \ STD PLAN 360.1 (1)10"x4"WET TAP \ / (1) 4" TAPPING TEE (FLxRJ) \ / PER COR STD DETAIL 300.1 \ / 2 LF 4" DI SPOOL (RJ) K SEE WET TAP NOTE THIS SHEET L I / 2 .�1 ° t�2h 31 / 0 87 FIRE DEPARTMENT a m CONNECTION I / - If ]STALL PUMP IN DDCVA TO DRAIN I // AULT. ROUTE POWER TO PUMP. V 20.93 ® 2 PUMP SHALL BE ZOELLER M98 -1/2 SUBMERSIBLE SUMP PUMP W/ - TICAL FLOAT SWTICH © 20 8 I R APPROVED EQUAL I 15 LF 6" PVC STORM AT 2% a �I CONNECT TkEXISTING CB AT 2.5' BELOW RI ELEVATION Q PVC HAS MINIMUM COVER OF 3 FT. USE DI OR OTHER (� (1) 4" 90° BEND (RJ) APPROVED PIPE 2 .77 W/ THRUST BLOCKING MATERIAL PER TABLE I ' 20 LF 4" DI CL 52 (RJ) PER COR STANDARD 4.2.1 .A2 OF THE 2017 i DETAIL 330.2 (TYP) RSWDM / a \ \ a \ -21.63 \ aLD a 1 1 c 1 I :D) .64 I 21.74 1 6 1.86 I I I V) I¢ 37 I I 20.96 / / I 0 5 10 20 V SCALE 111=10' Legend N 79°33'06" E - 46.81' PROPERTY LINE 8" SD @ xx% STORM DRAINAGE PIPE ❑®--- • ■❑OO YD/CO/CB/CB 2/MH 8" SS @ xx% SANITARY SEWER O • SANITARY MH/CO 12" DI W WATER MAIN tFAFD�PIVNWV FH/FDC/PIV/VALVE WATER VAULT/METER J WET TAP NOTE: THE CONTRACTOR SHALL COORDINATE WITH THE ONLY UTILITY CONTRACTOR ALLOWED BY THE CITY OF RENTON FOR WET TAPS: SPEAR TAPS (425.485.4764). COORDINATE WITH THE PUBLIC WORKS INSPECT SO THEY CAN WITNESS THE WET TAP. THE DEVELOPER'S CONTRACTO ILL BE RESPONSIBLE FOR ALL OTHER CONSTRUCTION ASSOCIATED WITA THE SERVICE APPROVED WET TAP CONTRACTORS INCLUDE: - SPEER TAPS, INC. - LEGACY TAPPING. INC. I I Er Is1 LJJ U IN COMPLIANCE WITH CITY OF RENTON STANDARDS > DEVELOPMENT ENGINEERING r LU Nathan Janders 07/29/2020 ' (n LU WATER UTILITY 0U M.Mitchell 07/28/2020 J J SURVEYED: SCALE: DAM KAP HORIZONTAL.-NAD 1983/1991 94 7 P O W E L L FIRE SERVICE 06/10/2020 LU HORIZONTAL.- KNK CITY OF RENTON, WA FlELDBOOK: DRAWN: RENTON PERMIT SET PAGE: O BTD DRAWING N0: PRI ONE INCH DATUM CHECKED:ONE AT FULL SCALE g� g�Dept.UTILITY PLAN C3.00 Planning/Building/Public Buildin Public Works IF NOT ONE INCH REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: 7 OF., 8 KNK S-413101 W-4131 01 Call Before You Dig. 8-1-1 or 1-800-424-5555 Underground Service (USA)