Loading...
HomeMy WebLinkAboutSR_HEX_SunsetGardens_210817_v5_FINALDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map SR_HEX_SunsetGardens_210817_v5_FINAL A. REPORT TO THE HEARING EXAMINER Hearing Date: August 17, 2021 Project File Number: PR21-000160 Project Name: Sunset Gardens Land Use File Number: LUA21-000168, SA-H, VAR, MOD Project Manager: Alex Morganroth, Senior Planner Owner: Renton Housing Authority, Mark Gropper, 2900 NE 10th St, Renton, WA 98056 Applicant/Contact: David Albers, SMR Architects / 117 S Main St, Suite 400, Seattle, WA 98104 Project Location: 2900 NE 10th St, Renton, WA 98056 Project Summary: The applicant is requesting Hearing Examiner Site Plan Review, a Variance, four modifications, and concurrence with the Sunset Area Planned Action EIS for a proposed four-story mixed-use building and associated improvements located at 2900 NE 10th St. The proposed building would contain 76 affordable housing units with approximately 13,645 square feet of ground floor space occupied by the Renton Housing Authority services staff. The residential density of the completed project would result in approximately 66 dwelling units per net acre. The existing 13,416 square foot Renton Housing Authority building would be removed. The project site is approximately 1.28 acres and located within the Center Village (CV) zoning district, Commercial Mixed Use (CMU) comprehensive plan designation, and Urban Design District ‘D’ overlay. Vehicle access to the subject property would occur from a single driveway located on the northwest portion of the site on Jefferson Ave NE. The applicant would provide parking for 56 vehicles. The applicant would construct street frontage improvements abutting the project site along NE 10th St and Jefferson Ave NE. There are nineteen (19) significant trees on the subject property all of which are proposed to be removed. The applicant is requesting a variance related to the required location for parking to allow parking between the building and the public street. The applicant is also requesting four code modifications related to street frontage improvements, retaining wall height, parking stall size, and refuse and recycling standards. Studies included with the project application include drainage report, arborist report, geotechnical report, and traffic impact analysis. The project site is within the Sunset Planned Action Area. A moderate landslide hazard and sensitive slopes are mapped on the project site according to COR Maps. Site Area: 1.28 acres City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 2 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL B. EXHIBITS: Exhibits 1-17: As shown in the Environmental Review Committee (ERC) Concurrence Memo Exhibit 18: Staff Report to the Hearing Examiner Exhibit 19: Proof of Neighborhood Meeting Exhibit 20: Planned Action Ordinance 5813 Exhibit 21: Sunset Area Final Environmental Impact Statement Exhibit 22: Garbage and Recycling Screening Detail C. GENERAL INFORMATION: 1. Owner(s) of Record: Renton Housing Authority, Mark Gropper, 2900 NE 10th St, Renton, WA 98056 2. Zoning Classification: Center Village (CV) Urban Design District D Overlay 3. Comprehensive Plan Land Use Designation: Commercial Mixed Use (CMU) 4. Existing Site Use: Renton Housing Authority on-site services 5. Critical Areas: Moderate landslide hazard, sensitive slopes 6. Neighborhood Characteristics: a. North: Multifamily Residential; CV Zone b. East: Multifamily Residential; CV Zone and RMF Zone c. South: Multifamily Residential; CV Zone d. West: Commercial; CV Zone 7. Site Area: 1.28 acres D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Epstein Annexation N/A 1246 04/16/1946 Sunset Area Planned Action EIS LUA10-052 N/A 06/06/2011 Comprehensive Plan N/A 5758 06/22/2015 Zoning N/A 5758 06/22/2015 Sunset Area Planned Action Ordinance (Revised) N/A 5813 08/08/2016 E. PUBLIC SERVICES: 1. Existing Utilities City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 3 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL a. Water: Water service will be provided by the City of Renton and includes the following infrastructure: i. Existing 8-inch water main in NE 10th Street. ii. Existing 6-inch water main on the north side of NE 10th St south of the site and east of Jefferson Ave NE iii. Existing 8-inch water main in Jefferson Ave NE west of the site. iv. Existing 8-inch water main in Jefferson Ave NE west, north and east of the site. v. Existing 12-inch water stub ending at the southeast corner of the intersection of NE Sunset Blvd and NE 10th St. b. Sewer: Sewer service is provided by the City of Renton. There is an existing 8-inch lined concrete sewer main in Jefferson Ave NE. c. Surface/Storm Water: There is an existing 12-inch stormwater main located along the western frontage, along Jefferson Avenue NE. Additionally, there is an existing 12-inch stormwater main located along the southern frontage, along NE 10th St. 2. Streets: NE 10th St is classified as a collector street with a total right-of-way width of 60 feet. Jefferson Ave NE is classified as a residential access street and commercial access street with an existing right-of-way width of 50 feet. 3. Fire Protection: Renton Regional Fire Authority (RRFA) F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table – Uses Allowed in the Zoning Designations c. Section 4-2-120A: Development Standards for Commercial Zoning Designations d. Section 4-2-120C: Conditions Associated with Development Standards Tables for Commercial Zoning Designations 2. Chapter 3 Environmental Regulations and Overlay Districts a. Section 4-3-050: Critical Area Regulations b. Section 4-3-100: Urban Design Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 6 Streets and Utility Standards a. Section 4-6-030: Drainage (Surface Water) Standards b. Section 4-6-040: Sanitary Sewer Standards c. Section 4-6-060: Street Standards d. Section 4-6-080: Water Service Standards 5. Chapter 9 Permits – Specific a. Section 4-9-200: Master Plan and Site Plan Review b. Section 4-9-250: Variances, Waivers, Modifications, and Alternates 6. Chapter 11 Definitions City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 4 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element 2. Housing and Human Services Element H. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on May 27, 2021 and determined the application complete on the same day. The project complies with the 120-day review period. 2. A public meeting was held on virtually on April 14, 2021. Fourteen (14) members of the public attending the meeting, and provided comments and questions regarding the following issues: security, parking, exterior design (Exhibit 19). 3. The project site is located 2900 NE 10th St, Renton, WA 98056. 4. The project site is currently developed with a one-story office building used by the Renton Housing Authority for on-site services. 5. Access to the site would be provided via a single 20-foot wide driveway off of Jefferson Ave NE. 6. The property is located within the Commercial & Mixed Use (CMU) Comprehensive Plan land use designation. 7. The site is located within the Center Village (CV) zoning classification and within Urban Design District D overlay. 8. There are approximately nineteen (19) trees located on-site, of which the applicant is proposing to remove all nineteen (19) trees. 9. The site is mapped with a moderate landslide hazard and sensitive slopes. 10. Approximately 4,240 cubic yards of material would be cut on-site and approximately 1,020 cubic yards of fill is proposed to be brought into the site. 11. The applicant is proposing to begin construction in January of 2022 and end in May of 2023. 12. Staff received no public comment letters. 13. No other public or agency comments were received. 14. The subject property is located within the Sunset Planned Action Area where a Planned Action Ordinance (Ord. 5813) (Exhibit 20) was adopted in accordance with the State Environmental Policy Act (SEPA) for redevelopment of the Highlands Area. The Final EIS document was issued April 1, 2011 (Exhibit 21). 15. The Environmental Review Committee (ERC) reviewed the Sunset Gardens application and issued a Concurrence Memo designating the proposal a planned action (Exhibit 1) and therefore the project would not require a SEPA threshold determination, preparation of an EIS, or be subject to further environmental review pursuant to SEPA. 16. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 5 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL 17. Comprehensive Plan Compliance: The site is designated Commercial & Mixed Use (CMU) on the City’s Comprehensive Plan Map. The purpose of the CMU designation is to allow residential uses as part of mixed-use developments, and support new office and commercial development that is more intensive than what exists to create a vibrant district and increase employment opportunities. The intention of this designation is to transform strip commercial development into business districts through the intensification of uses and with cohesive site planning, landscaping, signage, circulation, parking, and the provision of public amenity features. The proposal is compliant with the following development standards if all conditions of approval are met: Compliance Comprehensive Plan Analysis ✓ Policy L-2: Support compact urban development to improve health outcomes, support transit use, maximize land use efficiency, and maximize public investment in infrastructure and services. ✓ Goal L-H: Plan for high-quality residential growth that supports transit by providing urban densities, promotes efficient land utilization, promotes good health and physical activity, builds social connections, and creates stable neighborhoods by incorporating both built amenities and natural features. ✓ Goal L-I: Utilize multiple strategies to accommodate residential growth, including: • Development of new multi-family and mixed-use in the City Center and in the Residential High Density and Commercial Mixed Use designations, and Infill development on vacant and underutilized land in established neighborhoods and multi-family areas. ✓ Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new development is designed to be functional and attractive. ✓ Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development. ✓ Policy L-47: Accommodate change in a way that maintains Renton’s livability and natural beauty. ✓ Policy L-48: Address privacy and quality of life for existing residents by considering scale and context in infill project design. ✓ Policy L-51: Include human-scale features such as pedestrian pathways, quality landscaping, and public spaces that have discernible edges, entries, and borders to create a distinctive sense of place in neighborhoods, commercial areas, and centers. ✓ Policy L-52: Orient buildings in developments toward the street or a common area, rather than toward parking lots. ✓ Policy L-56: Complement the built environment with landscaping using native, naturalized, and ornamental plantings that are appropriate for the situation and circumstance and provide for respite, recreation, and sun/shade. ✓ Policy L-60: Improve the appearance of parking lots through landscaping and screening. ✓ Policy HHS-3: Work with other jurisdictions and organizations, including the Renton Housing Authority and non-profit housing developers, to address the need for housing City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 6 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL to be affordable to very low-income households. This housing should focus on accessibility, mobility, and proximity to social services. 18. Zoning Development Standard Compliance: The purpose of the Center Village Zone (CV) is to provide an opportunity for concentrated mixed-use residential and commercial redevelopment designed to urban rather than suburban development standards that supports transit-oriented development and pedestrian activity. Use allowances promote commercial and retail development opportunities for residents to shop locally. Uses and standards allow complementary, high-density residential development, and discourage garden-style, multi-family development. The proposal is compliant with the following development standards, as outlined in RMC 4-2-120.A, if all conditions of approval are met: Compliance CV Zone Develop Standards and Analysis ✓ Use: The applicant proposes to develop the site with a residential mixed-use building to include Attached dwellings – Flats and an On-site Service. Staff Comment: Pursuant to RMC 4-2-060C, the CV zone allows attached dwelling units - flats subject to special condition 6 which states that where not prohibited, attached dwelling units are permitted subject to the following conditions and standards in addition to RMC 4-4-150, Residential Mixed Use Development Standards. The applicant proposes one (1) mixed-use building with attached multi-family dwelling units on floors two through four where residents live in private units that are attached to one or multiple dwelling units by one or more common roof(s), wall(s), or floor(s) within a building. The ground floor of the building would be utilized by the Renton Housing Authority and would be classified as an on-site service. On-site services are a permitted use in the CV zone. A portion of the ground floor also contains a 660 square foot residential lobby with access to an elevator, stairs, and an ADA restroom. Structured parking is proposed on the first floor but is located primarily below grade due to the sloping nature of the site. ✓ Density: The density range required in the CV zone is a minimum of 20.0 dwelling units per net acre to a maximum 80 dwelling units per net acre. Assisted living bonus: 1.5 times the maximum density may be allowed subject to conditions of RMC 4-9-065. Net density is calculated after the deduction of sensitive areas, areas intended for public right-of-way, and private access easements from the gross site area. Staff Comment: The net area of the property is 50,280 square feet or 1.15 acres after 5,477 square feet of right-of-way dedications along Jefferson Ave NE and NE 10th St. The proposed mixed-use building would include 76 dwelling units. The proposed attached dwelling units on the subject property would result in net density of 66 dwellings units per net acre (76 units / 1.15 acres = 65.84 du/ac rounded up to the nearest whole number). Therefore, the proposal complies with the density range permitted in the CV zone. ✓ Lot Dimensions: The minimum lot size required (for lots created after Nov. 10 2004) in the CV zone is 25,000 sq. ft. There are no minimum lot width or depth requirements. Staff Comment: The subject property would be 50,280 sq. ft. in size after the required dedication. The applicant does not propose to subdivide the lot. ✓ Setbacks: The minimum front yard setback is 15 ft. The minimum setback may be reduced to 0 ft. through the site plan review process, provided blank walls are not located within the reduced setback. A maximum front yard setback of 20 ft. is required. The minimum secondary front setback is 15 ft. The minimum setback may be reduced City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 7 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL to 0 ft. through the site plan review process, provided blank walls are not located within the reduced setback. The maximum secondary front yard setback is 20 feet. There are no minimum side or rear yard setbacks, except 15 ft. if the lot abuts or is adjacent to a lot zoned residential. Staff Comment: The site contains a front yard (NE 10th St) and two secondary front yards (Jefferson Ave NE). As shown on the site plan (Exhibit 2) the west façade (secondary front yard) of the building fronts Jefferson Avenue NE has a maximum setback of approximately 19 feet. The south façade (front yard) of the building fronts NE 10th Street has maximum setback of 19.5-feet. The east façade (secondary front yard) of the building fronts Jefferson Avenue NE and has a maximum front yard setback of approximately 16.5 along the west wing. No portion of the building lies within the minimum setback area. There would be no side or rear yards as the abutting north and east property is CV zoned. Therefore the project will comply with the setback requirements for the CV zone. ✓ Building Standards: The CV zone has a maximum building coverage 65% of total lot area or 75% if parking is provided within the building or within an on-site parking garage. The maximum building height permitted is 50 ft., except 70 ft. for vertically mixed use buildings (commercial and residential). Heights may exceed the Zone’s maximum height with a Conditional Use Permit. Staff Comment: Following dedication for frontage improvements, the applicant’s lot would result in 50,280 square feet of lot area. The applicant’s proposed building would be four (4) stories in height (approximately 42.6-feet) and cover 13,645 square feet or 28-percent (28%) of the lot. ✓ Building Orientation: See urban design regulations in RMC 4-3-100. Commercial and civic uses shall provide entry features on all sides of a building facing a public right-of- way or parking lot. The front entry of residential only uses shall be oriented to a public or private street developed to the required standards in RMC 4-6-060. Staff Comment: The proposed building is located on three (3) street frontages including NE 10th St and Jefferson Ave NE on two sides. A main entrance to the future RHA offices is proposed on NE 10th St. A separate entrance to the residential lobby is also located on NE 10th St east of the office entrance. Two secondary access doors for the residential uses are proposed along Jefferson Ave NE. Two additional secondary access entries are proposed along Jefferson Ave NE on the west façade to provide access to interior RHA office spaces. Lastly, an exterior egress door and a mechanical room door are located on the east Jefferson Ave NE frontage. Four canopies are proposed to provide weather protection canopy and add articulation to the building including two on Jefferson Ave NE and two on NE 10th St. See FOF 19: Urban Design District Review, Building Entries. Compliant if condition of approval is met Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot onsite landscape strip along all public street frontages with the exception of areas for required walkways and driveways . Additional minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4- 6-060. Street trees from the City’s Approved Street Tree List and, at a minimum, groundcover, are to be located in this area when present. Spacing standards shall be based on the mature size of the street tree as set forth in RMC 4-4-070F.2 City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 8 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL All surface parking lots shall have perimeter landscaping. Such landscaping shall be at least ten feet (10') in width as measured from the street right-of-way. Standards for planting shall be as follows: a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi- family, commercial, and industrial uses at an average minimum rate of one tree per thirty (30) lineal feet of street frontage. b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped area. Up to fifty percent (50%) of shrubs may be deciduous. c. Ground cover in sufficient quantities to provide at least ninety percent (90%) coverage of the landscaped area within three (3) years of installation. Interior Parking Lot Landscaping: Surface parking lots with more than fourteen (14) stalls shall be landscaped as follows: Surface parking lots with between 15 and 50 spaces shall provide 15 sf of interior parking lot landscaping per parking space, 51 and 99 spaces shall provide 25 sf of interior parking lot landscaping per parking space, and 100 or more spaces shall provide 35 sf of interior parking lot landscaping per parking space. Interior parking lot landscaped areas shall have minimum dimensions of 8 feet (8’) by 12 feet (12’). Staff Comment: The applicant submitted a Conceptual Landscaping Plan (Exhibit 9) with the land use application. Proposed planting areas would contain trees, shrubs, and groundcover, including but not limited to, Vine maple, Shore pine, Golden sedge, Sweetbox, White spirea, Sword fern, and Snowberry. The applicant would be required to submit a Detailed Landscape and Irrigation Plan with the civil construction permit submittal that provides location, size, quantity, planting details, and other applicable items as set forth in the RMC 4-8-120 submittal requirements. The applicant’s conceptual landscaping plan identifies a minimum 10-foot wide landscaping area along the NE 10th St and Jefferson Ave NE street frontages. As indicated on the Landscape Plan (Exhibit 3), the on-site landscaping would include a mix of trees, shrubs, and ground cover per the requirements number and spacing requirements in RMC 4-3-070.L.2. Three bioretention planters are proposed on the west side of the site abutting the Jefferson Ave ROW and. As proposed, the planters appear to be partially located within the required 10-foot landscaping area. In order to ensure compliance with the required on-site landscaping is prioritized over the bioretention planters, staff recommends as a condition of approval, the applicant shall submit a detailed landscaping plan with the civil construction permit that provides those items noted in RMC 4-8-120D.12 and a detailed irrigation plan. The plan shall also clearly identify the 10-foot wide onsite street frontage landscaping along Jefferson Ave NE that is displaced by the stormwater facilities as currently shown. The stormwater facilities may be integrated into the street frontage landscaping however the required frontage planting shall take priority and if the street frontage landscaping and stormwater facilities are unable to comingle, the facilities shall be relocated outside of the required street frontage landscaping area. The detailed landscaping plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Sixteen (16) street trees of unknown variety are proposed in the ROW planter strip. The species and spacing of the trees would be required to comply with the City of Renton Approved Tree List and Spacing Guidelines. Additional landscaping is proposed on site in the form of above grade planters, terracing along NE 10th St, and a memorial garden to the north of the buildings west wing. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 9 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Perimeter and interior landscaping is integrated into the surface parking lot design. Perimeter parking lot landscaping is approximately 10 feet in width along the portion of the parking lot adjacent to the Jefferson Ave NE ROW. The proposal includes approximately 1,385 sq. ft. of interior parking lot landscaping separate from the required perimeter landscaping that meets the dimensional requirements in code, or 25 sq. ft. per one parking stall. Therefore, the project complies with the interior and perimeter parking lot landscape requirements. Verification of compliance would occur at the time of formal civil construction permit review. Compliant if Condition of Approval is met Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4- 4-130) require at least ten percent (10%) of the significant trees be considered protected and retained in commercial developments. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; and significant trees over sixty feet (60') in height or greater than eighteen inches ( 18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non-native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. Staff Comment: The applicant’s Arborist Report prepared by Fazio Associates, LLC, dated February 1, 2021 (Exhibit 15) and Tree Retention Plan (Exhibit 8) identifies nineteen (19) total trees on the site, the largest of which is an 18.5-inch DBH Scots pine. Twelve (12) of the trees are located frontage areas that would be dedicated to the City per the development regulations. Due to their location in future ROW, the twelve (12) trees do not count towards the tree retention requirement. The applicant also identifies the potential need to remove one off-site tree on the vacated portion of Jefferson Ave NE that may be impacted by the proposed frontage improvements. Based a required retention rate of 10%, the applicant is required to retain at least one significant tree. The remaining seven (7) trees are located on the site and are proposed for removal and therefore the applicant is required to install a minimum of six (6) 2-inch replacement trees on the site. Per the submitted schematic Landscape Plan (Exhibit 3), the applicant has proposed a replacement far in excess of the required six (6) trees. Due to the conceptual nature of the submitted landscape plan, staff recommends as a condition of approval that the applicant clearly indicate on the detailed landscape plan submitted with the civil construction permit application how the plan meets the 10% tree replacement requirements including but not limited to the 50% credit limitation provided for those trees that are required pursuant to RMC 4-4-070. If onsite replacement for the trees is not practical, then payment into the City’s Urban Forestry Program fund may be approved for those trees that cannot be accommodated onsite. The detailed landscape plan shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit approval. During construction, the offsite trees near the construction site in the vacated portion of Jefferson Ave NE would be required to comply with the tree protection measures City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 10 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL during construction (RMC 4-4-130H.9). The eight central components of tree protection include defining and protecting the drip line, erecting and maintaining a temporary six- foot-high chain link construction fence with placards around the tree to be retained, protecting the tree from grade changes, keeping the area clear of impervious surface material, restricting grading within the drip line, providing 3” of bark mulch within the required fencing, retaining a certified arborist to ensure trees are protected from development activities, and alternate protection/safeguards as necessary. Compliant if condition of approval is met and if variance under FOF 22 is approved Parking: For residential uses, required parking shall be located underground or under building (on the first floor of the structure), or in an attached or detached structure. Any additional parking may not be located between the building and public street unless located within a structured parking garage. For commercial uses, required parking may not be located between the building and the public street unless located within a structured parking garage. For mixed uses, joint parking is required subject to RMC 4-4-080E3. Parking regulations for low income attached dwellings are a minimum of 1 for each 4 dwelling units with a maximum of 1.75 per dwelling unit allowed. Parking regulations for on-site services require a minimum and maximum of 3 per 1,000 sq. ft. Parking regulations for low income attached dwelling units require a minimum of 1 for each 4 dwelling units and a maximum of 1.75 per dwelling units. Standard parking stall dimensions for surface lots are 9 feet by 20 feet, compact stall dimensions are 8 ½ feet by 16 feet. Standard parking stall dimensions for structured parking are 8’4” by 15’. Compact stall dimensions are 7’6” by 12” Maximum number of compact spaces shall not account for more than 50% for structured parking and 30% for the surface lot. Staff Comment: The applicant proposes a vehicle parking area that would be partially covered by the second-floor outdoor terrace and would consist of 56 stalls in a mixture of tuck-under, structured, and surface parking. The northeastern portion of the stalls would be uncovered. The structured parking area would be partially open on the north side but obscured from view when viewing the building from the surrounding ROW due to the grade change from east to west. As shown on the Site Plan (Exhibit 2) approximately eleven (11) parking stalls would be located between the building and the street (Jefferson Ave NE) along the eastern portion of the façade. The applicant submitted a variance (FOF 22: Variance) in order to allow surface parking between the building and this portion of public street. Per RMC 4-4-070.F.10, the applicant would be required to provide a minimum of one space for every four (4) low income attached dwelling units and a maximum of 1.75 spaces per dwelling unit. For the on-site service (RHA offices), the applicant would be required to provide a minimum and maximum of three (3) spaces per 1,000 sq. ft. of net floor area. Based on a total of 76 - low income attached dwelling units, the applicant is required to provide a minimum of nineteen (19) spaces (76 / 4) and a maximum of 133 spaces (76 x 1.75). Based on a total on-site net floor area of 10,483 sq. ft., the applicant is required to provide 32 spaces for the RHA offices. Therefore based on the square footage and number of attached units, the applicant is required to provide a total number of spaces between 51 (32 + 19) and a maximum of 166 (3+ 133) in order to meet code. The applicant proposed a total of 56 parking spaces onsite (29 standard City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 11 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL stalls, 24 compact stalls and 3 ADA stalls) including 23 spaces for the attached units and 32 spaces for the on-site service. A total of twenty (20) structured or tuck-under parking stalls are available for the residential units. Per RMC 4-4-080.E.3, a joint use parking agreement is required for parking facilities authorized to serve multiple uses in order allow commercial users of the building to utilize the residential parking spaces during off-peak times and vice versa. Therefore, in order to ensure compliance with the joint use parking standard, staff recommends, as a condition of approval, the applicant shall provide a joint use parking agreement for the residential and on-site service uses on the site. The joint use agreement shall be provided to the Current Planning Project for review and approval prior to the issuance of a Temporary or Final Certificate of Occupancy. In addition, to ensure a minimum of nineteen (19) structured or tuck-under stalls are designated for the exclusive use of the residential units in the building, staff recommends, as a condition of approval, the applicant shall mark the designated stalls with paint, signage, or an alternative method approved by the Current Planning Project Manager. The project site is in very close proximity to multiple King County Metro bus lines and a wide range of shopping options are within easy walking distance of the site which is ideal for tenants without vehicles. The proposal complies with the parking ratios of the code and the provides the required structured parking for the low income attached dwelling units. The applicant has requested a modification to reduce the size of the of parking stalls in the structured parking areas. The standard spaces measure 15-feet by 8-feet, 4-inches and the compact spaces measure 12-feet by 7.5-feet. The applicant has also requested a modification to allow for a reduced drive-aisle width of 22-feet for the surface parking spaces along the east property line. See FOF 23: Parking Modification for analysis. Compliant if Modification under FOF 23 is approved Bicycle Parking: The number of bicycle parking spaces shall be equal to ten percent (10%) of the number of required off-street vehicle parking spaces. Staff Comment: As shown on the floor plans (Exhibit 4), the applicant is proposing a total of 45 total bicycle parking spaces on the site including 40 within the paved parking garage and five (5) near the primary entrance of the building. The proposed site plan complies with the minimum number of bicycle parking spaces required for the 76 units and ground floor on-site service. The applicant has also requested a modification to allow for 32 of the 45 bicycle racks to be wall mounted instead of ground mounted. If the modification is approved, the proposed bike racks would comply with the design requirements. See FOF 23 for additional analysis. Compliant if Modification under FOF 25 is approved and condition of approval is met Fences and Retaining Walls: A maximum of eight feet (8') anywhere on the lot provided the fence, retaining wall or hedge does not stand in or in front of any required landscaping or pose a traffic vision hazard. There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Staff Comment: The applicant has proposed three (3) rockery retaining walls approximately four (4) feet in height along the southern façade facing NE 10th St in order raise the grade and hide the exterior concrete wall of the ground floor parking garage. The terraced walls would be tied into an additional four-foot (4’) tall rockery wall that will run abut the sidewalk along NE 10th St. The applicant has also proposed a City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 12 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL retaining wall at the southeast corner to provide a transition from the surface parking at the ground floor level and the existing grade at the back of the ROW at Jefferson Ave NE where there is an emergency exit from the building. Due to the retaining wall proposed to be located perpendicular to the slope, no horizontal level grading would be provided at the base. The height of the wall would be approximately 9.5 feet and would include a 42-inch tall guardrail on top to provide fall protection. The total combined height of the wall and guardrail would be approximately twelve (12’) feet. An existing on-site rockery wall between the parking lot and the Jefferson Ave NE ROW is proposed to be retained and varies in between two feet (2’) and ten feet (10’). All three (3) retaining walls, including the two proposed and one existing wall, would be located within the required three-foot (3’) setback from the ROW. In addition, both the existing rockery wall abutting Jefferson Ave and the new retaining wall between the parking lot and emergency exit would exceed the eight-foot (8’) maximum allowable height in commercial zones. Therefore the applicant is requesting a modification from RMC 4-4- 040.C.2 in order to reduce the horizontal distance of level grade abutting a retaining wall, reduce the minimum setback between the base of retaining walls abutting public rights-of-way, and to allow a retaining wall (new) and rockery wall (existing) to exceed eight-feet (8’) in height. See FOF 25: Fences, Hedges, and Retaining Wall Standards Modification for additional analysis. Compliant if Modification under FOF 24 is approved Refuse and Recycling: In office, educational and institutional developments, a minimum of two (2) square feet per every one thousand (1,000) square feet of building gross floor area shall be provided for recyclables deposit areas and a minimum of four (4) square feet per one thousand (1,000) square feet of building gross floor area shall be provided for refuse deposit areas. A total minimum area of one hundred (100) square feet shall be provided for recycling and refuse deposit areas. Collection points shall be located in a manner so that hauling trucks do not obstruct pedestrian or vehicle traffic on-site, or project into any public right-of-way. In multifamily developments, a minimum of one and one-half (1-1/2) square feet per dwelling unit in multi-family residences shall be provided for recyclables deposit areas, except where the development is participating in a City-sponsored program in which individual recycling bins are used for curbside collection. A minimum of three (3) square feet per dwelling unit shall be provided for refuse deposit areas. A total minimum area of eighty (80) square feet shall be provided for refuse and recyclables deposit areas. There shall be a minimum of one refuse and recyclables deposit area/collection point for each project. There shall be at least one deposit area/collection point for every thirty (30) dwelling units. Staff Comment: The proposed on-site service area contains approximately 13,300 square feet thereby defaulting to the minimum 100 square feet of recycling and refuse deposit area. A total of 76 units would require a minimum 114 sq. ft. for recyclables and a minimum 228 sq. ft. for refuse. Therefore, the applicant is required to provide a minimum of 442 sq. ft. for recycling and refuse. The site plan (Exhibit 2) indicates a single refuse and recycling area approximately 564 square feet in size. The enclosure is located along the Jefferson Ave NE street frontage and would be cladded with fiber cement board lap siding with foundation screening along the street frontage and north side. Additionally, the applicant has proposed a sloped metal shed roof on top of the enclosure. The access gate for the enclosure opens along the western wall into a concrete pad adjacent to the internal drive aisle accessed of off Jefferson Ave NE. The gates meet the minimum 12-foot width requirement but neither the gates nor the enclosure provide the required 12-foot vertical clearance of the opening. The applicant City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 13 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL has requested a modification to allow for a reduced 7-foot vertical clearance as after discussions with the refuse hauler, they determined that the dumpsters would be collected in the access driveway on collection days and therefore the enclosure would not need to be accessed by a truck (See FOF 24: Refuse and Recyclables Standards Modification). The applicant has also requested a modification in order to provide only one trash and recycling enclosure instead of three as would typically be required for 76 units. According to the applicant, the request is due to the difficulty in providing more than one enclosure on a small site with varying grades. Therefore, the project complies with requirements for the refuse and recycling enclosure if the modification under FOF 24 is approved. Compliant if Conditions of Approval are met Screening: All onsite surface mounted utility equipment shall be screened from public view. Screening shall consist of equipment cabinets enclosing the utility equipment, solid fencing or a wall of a height at least as high as the equipment it screens, or a landscaped visual barrier allowing for reasonable access to equipment. Equipment cabinets, fencing, and walls shall be made of materials and/or colors compatible with building materials. All operating equipment located on the roof of any building shall be enclosed so as to be screened from public view. Staff Comment: The only surface mounted utility equipment identified on the plan, a transformer located to the west of the refuse and recycling enclosure building, would be screened from the ROW and adjacent property through the use of landscape screen made up of trees, shrubs, and groundcover. The conceptual landscape plan (Exhibit 9) did not identify the locations of specific plants and therefore staff was unable to determine whether or not the transformer would be adequately screened. In addition, the applicant did not provide details of roof or surface mounted equipment and/or screening identified for such equipment with the land use application. Therefore, staff recommends, as a condition of approval, that the applicant be required to submit a surface mounted utility plan that includes cross-section details with the civil construction permit application. The applicant shall work with franchise utilities to ensure, as practical, utility boxes are located out of public ROW view, active common open spaces, and they shall not displace required landscaping areas. The plan shall provide and identify screening measures consistent with the overall design of the development. The surface mounted utility plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. In addition, staff recommends as a condition of approval that the applicant be required to submit a rooftop equipment exhibit with the elevation plans associated with the building permit application. The exhibit shall provide cross section details and identify proposed rooftop screening that is integral and complementary to architecture of the buildings. The exhibit shall be reviewed and approved by the Current Planning Project Manager. Compliant if Modification under FOF 27, Residential Mixed Use Design Standards is approved Residential Mixed Use Design Standards: For vertically mixed use buildings, the facade necessary for interior entrances, lobbies, and areas/facilities developed for the exclusive use of the building’s residents, or their guests, is limited to twenty five percent (25%) of the overall facade along any street frontage or the primary facade. Ground Floor Commercial Space Standards: At a minimum, the development shall include ground floor commercial space along any street frontage or, in the absence of street frontage, along the primary facade of the building in conformance with the following standards: City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 14 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL a. A minimum average depth of thirty feet (30') and no less than twenty feet (20') at any given point; b. A minimum floor-to-ceiling height of eighteen feet (18'), and a minimum clear height of fifteen feet (15') unless a lesser clear height is approved by the Administrator; c. ADA compliant bathrooms (common facilities are acceptable); d. A central plumbing drain line; and e. A grease trap and a ventilation shaft for a commercial kitchen hood/exhaust. Staff Comment: The applicant has proposed a mixed-use building with an on-site service (RHA) located on the first floor and 76 low income attached dwelling units above. Approximately 50% of the primary south façade is developed for the exclusive use of the future residents including both an entrance lobby/vestibule, storage space, and the residential units. Approximately 45% of the portion of the east façade in front of the Jefferson Ave NE is developed for the exclusive use of the future residents and primarily consists of residential units. The entire west façade is developed for the exclusive use of the non-residential portion of the project. The onsite service is developed at an average depth of fifty-eight feet (58’) across the south and west facades. The exact floor to ceiling height was not identified on the submitted elevations but appears to be less than eighteen feet (18’ however staff would support a lesser height with authority provided above due to the nature of tenant and the unlikelihood that a typical commercial retail or restaurant use would replace the RHA in the future. An ADA compliant bathroom in both the residential entry lobby as well as the on-site service area lobby. Due to the proposed on-site service use, neither a central plumbing line nor grease trap/ventilation shaft are proposed. See FOF 27, Residential Mixed Use Design Standards Modification. 19. Design District Review: The project site is located within Design District ‘D’. The following table contains project elements intended to comply with the standards of the Design District ‘D’ Standards and guidelines, as outlined in RMC 4-3-100.E: Compliance Design District Guideline and Standard Analysis 1. SITE DESIGN AND BUILDING LOCATION: Intent: To ensure that buildings are located in relation to streets and other buildings so that the Vision of the City of Renton can be realized for a high-density urban environment; so that businesses enjoy visibility from public rights-of-way; and to encourage pedestrian activity. a. Building Location and Orientation: Intent: To ensure visibility of businesses and to establish active, lively uses along sidewalks and pedestrian pathways. To organize buildings for pedestrian use and so that natural light is available to other structures and open space. To ensure an appropriate transition between buildings, parking areas, and other land uses; and increase privacy for residential uses. Guidelines: Developments shall enhance the mutual relationship of buildings with each other, as well as with the roads, open space, and pedestrian amenities while working to create a pedestrian oriented environment. Lots shall be configured to encourage variety and so that natural light is available to buildings and open space. The privacy of individuals in residential uses shall be provided for. ✓ Standard: The availability of natural light (both direct and reflected) and direct sun exposure to nearby buildings and open space (except parking areas) shall be considered when siting structures. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 15 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: The scale of the building transitions from four-stories above grade to three-stories along NE 10th Street as the topography rises to meet the eastern portion of Jefferson Avenue NE. At four-stories in height the development’s roof will approximately match the apartment building to the east that are up the hill in relation to the project site. The development will be taller than the one-story commercial buildings to the west of the project site. However, it not anticipated to significantly impact the availability of natural light due to lack of windows on the backside of the commercial building and orientation of the proposed development. ✓ Standard: Buildings shall be oriented to the street with clear connections to the sidewalk. Staff Comment: The proposed building will be surrounded by ROW on two sides and partially on the third side. The building is located 16-feet from the future dedicated street frontage along Jefferson Ave NE and NE 10th St. An eight (8’) foot wide sidewalk concrete pathway connects the public sidewalk to two five-foot (5’) concrete pathways that provide access to both the residential lobby and the RHA offices, providing a clear connection to both uses. Pedestrian level glazing along the two primary street facing façades (south and west) provides transparency and orientation to the abutting streets. ✓ Standard: The front entry of a building shall be oriented to the street or a landscaped pedestrian-only courtyard. Staff Comment: The building’s two main entries to the RHA offices on the first floor and residential lobby area with elevator access are oriented towards NE 10th St. Compliant if Condition of Approval is met Standard: Buildings with residential uses located at the street level shall be: a. Set back from the sidewalk a minimum of ten feet (10') and feature substantial landscaping between the sidewalk and the building; or b. Have the ground floor residential uses raised above street level for residents’ privacy. Staff Comment: Due to the slope of the site, approximately three (3) units are located at street level along NE 10th St near the southeast corner of the building. All ground floor residential units are located a minimum of 17 feet from the sidewalk along NE 10th St. Although trees and ground cover and shown in the conceptual plan between the units and the sidewalk, substantial high-quality landscaping is essential in order to ensure privacy is maintained residents in the units and to comply with the standard. Therefore, staff recommends, as a condition of approval, the applicant shall submit a detailed landscape plan that incorporates additional trees and/or shrubs between the sidewalk and ground floor residential units along NE 10th St. The detailed landscape plan shall be submitted to and approved by the Current Planning Project Manager to civil construction prior to permit approval. b. Building Entries: Intent: To make building entrances convenient to locate and easy to access, and ensure that building entries further the pedestrian nature of the fronting sidewalk and the urban character of the district. Guidelines: Primary entries shall face the street, serve as a focal point, and allow space for social interaction. All entries shall include features that make them easily identifiable while reflecting the architectural character of the building. The primary entry shall be the most visually prominent entry. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 16 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Pedestrian access to the building from the sidewalk, parking lots, and/or other areas shall be provided and shall enhance the overall quality of the pedestrian experience on the site. Compliant if Condition of Approval is met Standard: A primary entrance of each building shall be located on the facade facing a street, shall be prominent, visible from the street, connected by a walkway to the public sidewalk, and include human-scale elements. Staff Comment: The primary entrances along NE 10th St would be connected to the public sidewalk via a “t-shaped” pedestrian pathway. As shown on the Architectural Elevations sheets (Exhibit 3), two main entries are flush with the plane of the façade. Weather protection is provided via individual canopies extending a minimum of 4.5 feet from the building façade. The canopy over the primary RHA on-site service entrance continues around the southwest corner of the building and provides an obvious visual cue for pedestrians accessing the building via Jefferson Ave NE. The wrap-around canopy also helps to break up the façade between the first and second floor and provides an additional pedestrian-scale feature in the plaza at the southwest corner of the site. Although the two proposed canopies provide a moderate measure of visual distinction to the entry, the entrances themselves lack prominence and are unremarkable when viewed from the street. Therefore staff recommends, as a condition of approval, the applicant shall submit revised exterior elevations with the building permit application that provide additional primary entry elements that are prominent and visible from the street. Entry elements may include but are not limited to, additional architectural articulation, an alternate facade that provide differentiation in material and/or color from other portions of the building, pedestrian level lighting, or other identifying visual features as approved by the Current Planning Project Manager. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. ✓ Standard: A primary entrance of each building shall be made visibly prominent by incorporating architectural features such as a facade overhang, trellis, large entry doors, and/or ornamental lighting. Staff Comment: See comment above. ✓ Standard Building entries from a street shall be clearly marked with canopies, architectural elements, ornamental lighting, or landscaping and include weather protection at least four and one-half feet (4-1/2') wide. Buildings that are taller than thirty feet (30') in height shall also ensure that the weather protection is proportional to the distance above ground level. Staff Comment: See primary entrance comments above. Both primary entries incorporate weather protection canopies that are at least 4.5-feet wide. Secondary entries on the west side of the building with access to Jefferson Ave NE also incorporate individual canopies with a minimum depth of 4.5 feet and are connected to the public sidewalk in Jefferson via a 10-foot wide scored concrete walkway. ✓ Standard: Building entries from a parking lot shall be subordinate to those related to the street. Staff Comment: The building’s two primary entries are located on NE 10th St. An emergency only egress is located on the east façade near the parking area and two unmarked RHA employee-only entrances are located in the parking area. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 17 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ✓ Standard: Features such as entries, lobbies, and display windows shall be oriented to a street or pedestrian-oriented space; otherwise, screening or decorative features should be incorporated. Staff Comment: See other entry discussions above. N/A Standard: Multiple buildings on the same site shall direct views to building entries by providing a continuous network of pedestrian paths and open spaces that incorporate landscaping. Staff Comment: No applicable. The proposal is for a single building. N/A Standard: Ground floor residential units that are directly accessible from the street shall include entries from front yards to provide transition space from the street or entries from an open space such as a courtyard or garden that is accessible from the street. Staff Comment: Not applicable. No residential units are directly accessible from the street. c. Transition to Surrounding Development: Intent: To shape redevelopment projects so that the character and value of Renton’s long-established, existing neighborhoods are preserved. Guidelines: Careful siting and design treatment shall be used to achieve a compatible transition where new buildings differ from surrounding development in terms of building height, bulk and scale. ✓ Standard: At least one of the following design elements shall be used to promote a transition to surrounding uses: 1. Building proportions, including step-backs on upper levels in accordance with the surrounding planned and existing land use forms; or 2. Building articulation to divide a larger architectural element into smaller increments; or 3. Roof lines, roof pitches, and roof shapes designed to reduce apparent bulk and transition with existing development. Additionally, the Administrator may require increased setbacks at the side or rear of a building in order to reduce the bulk and scale of larger buildings and/or so that sunlight reaches adjacent and/or abutting yards. Staff Comment: The building’s four-story height is proportionate to many of the surrounding businesses and Center Village zone. The scale of the building transitions from four-stories above grade to three-stories along NE 10th Street as the topography rises to meet the eastern portion of Jefferson Avenue NE. The building mass is further broken down through the modulation of siding that is distinguished by separate materials, textures, and colors to create the feeling of multiple buildings in place of one large mass. At four-stories in height the development’s roof will approximately match the apartment building to the east that are up the hill in relation to the project site. The development will be taller than the one-story commercial buildings to the west of the project site, but future redevelopment of the subject sites would likely result in buildings of a scale similar to the proposal. The commercial buildings are also located over 200 feet away from the future footprint of the building and will therefore not be overwhelmed by the bulk or height of the structure. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 18 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL d. Service Element Location and Design: Intent: To reduce the potential negative impacts of service elements (i.e., waste receptacles, loading docks) by locating service and loading areas away from high-volume pedestrian areas, and screening them from view in high visibility areas. Guidelines: Service elements shall be concentrated and located so that impacts to pedestrians and other abutting uses are minimized. The impacts of service elements shall be mitigated with landscaping and an enclosure with fencing that is made of quality materials. Service areas not adjacent to streets, pathways, or pedestrian-oriented spaces are encouraged to implement vegetative screening in addition to or as part of service enclosures. ✓ See also FOF 18 under Refuse and Recycling Standard: Service elements shall be located and designed to minimize the impacts on the pedestrian environment and adjacent uses. Service elements shall be concentrated and located where they are accessible to service vehicles and convenient for tenant use. Staff Comment: The location of the garbage enclosure would not impact the pedestrian environment and adjacent uses as the proposed location is not located near pedestrian areas or adjacent buildings. Tenants would have direct access to the enclosure from the primary entry to the enclosure via either onsite or offsite sidewalks. A man-door is located on the west façade to allow residents access to the enclosure when dropping off trash or recycling. ✓ Standard: In addition to standard enclosure requirements, garbage, recycling collection, and utility areas shall be enclosed on all sides, including the roof and screened around their perimeter by a wall or fence and have self-closing doors. Staff Comment: The garbage and recycling screening detail (Exhibit 22) and Landscaping Plan (Exhibit 9) indicate the enclosure would be enclosed on all sides with cement board lap siding. The enclosure would also utilize a metal shed roof and metal gate with composite wood slats. The applicant did not indicate whether the main gate utilized self-closing doors. However, due to the method used for collection which will require manually rolling the dumpsters outside of the enclosure, a self-closing door is not necessary. ✓ Standard: Service enclosures shall be made of masonry, ornamental metal or wood, or some combination of the three (3). Staff Comment: See discussion above. Compliant with Intent and Guidelines Standard: If the service area is adjacent to a street, pathway, or pedestrian-oriented space, a landscaped planting strip, minimum 3 feet wide, shall be located on 3 sides of such facility. Staff Comment: As indicated on the Landscaping Plan (Exhibit 9) the enclosure would include landscaping ranging between 0 and 8-feet in width along the Jefferson Ave NE frontage and along the north side of the enclosure. The applicant has requested to deviate from the landscape strip standard in order to reduce the width to 0 feet at the northeast corner of the enclosure. According to the applicant, the modification is necessary due to the pinch point created by the curvature of the ROW at the northeast corner of the enclosure which reduces the area available to provide landscaping. The applicant contends that the high-quality design of the enclosure combined with the additional planting strip width along the west, northwest, and east sides of the enclosure will meet the intent of the design standard. In addition, the average width of City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 19 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL the landscape strip provided is approximately six-feet (6’) and therefore provides double the amount of screening typically required. The additional 10-foot wide street frontage landscaping would provide additional screening. Staff concurs with the applicant’s justification and therefore supports the requested deviation to reduce the landscape planting strip, as the intent of the screening guideline would still be met. e. Gateways: Intent: To distinguish gateways as primary entrances to districts or to the City, special design features and architectural elements at gateways should be provided. While gateways should be distinctive within the context of the district, they should also be compatible with the district in form and scale. Guidelines: Service elements shall be concentrated and located so that impacts to pedestrians and other abutting uses are minimized. The impacts of service elements shall be mitigated with landscaping and an enclosure with fencing that is made of quality materials. N/A Standard: Developments located at district gateways shall be marked with visually prominent features. Staff Comment: Not applicable, the subject property is not located at a district gateway. N/A Standard: Gateway elements shall be oriented toward and scaled for both pedestrians and vehicles. Staff Comment: Not applicable. N/A Standard: Visual prominence shall be distinguished by two (2) or more of the following: a. Public art; b. Special landscape treatment; c. Open space/plaza; d. Landmark building form; e. Special paving, unique pedestrian scale lighting, or bollards; f. Prominent architectural features (trellis, arbor, pergola, or gazebo); g. Neighborhood or district entry identification (commercial signs do not qualify). Staff Comment: Not applicable. 2. PARKING AND VEHICULAR ACCESS: Intent: To provide safe, convenient access to the Urban Center and the Center Village; incorporate various modes of transportation, including public mass transit, in order to reduce traffic volumes and other impacts from vehicles; ensure sufficient parking is provided, while encouraging creativity in reducing the impacts of parking areas; allow an active pedestrian environment by maintaining contiguous street frontages, without parking lot siting along sidewalks and building facades; minimize the visual impact of parking lots; and use access streets and parking to maintain an urban edge to the district. a. Surface Parking: Intent: To maintain active pedestrian environments along streets by placing parking lots primarily in back of buildings. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 20 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Guidelines: Surface parking shall be located and designed so as to reduce the visual impact of the parking area and associated vehicles. Large areas of surface parking shall also be designed to accommodate future infill development. ✓ See also FOF 22: Development Standard Variance Standard: Parking shall be located so that no surface parking is located between: a. A building and the front property line; and/or b. A building and the side property line (when on a corner lot). Staff Comment: The parking area is primarily screened by the building and landscaping when viewed from the ROW. A small portion of the surface parking area on the east side of the site would be visible from the portion of Jefferson Ave NE east of the building. The applicant is requesting a variance from the standard to allow approximately eleven (11) stalls to be located between the building and the street. The applicant contends that due to the unique nature of the site which is surrounded by roadways on three sides, compliance with the standard is challenging. The applicant also contends that once installed, the perimeter parking lot landscaping combined with the eight (8’) foot planter strip will result in a high quality landscape screen that will obscure the surface parking from the portion of Jefferson Ave NE ROW adjacent to the site and meets the intent of the guideline. Staff concurs with the applicant and therefore supports the variance request. See also FOF 22: Variance for additional analysis. Staff also concurs with the applicant that the requested deviation from the surface parking to standard meets the intent of the guidelines due to being located significantly lower than the street grade and the meaningful perimeter landscaping proposed. ✓ See also FOF 22: Development Standard Variance Standard: Parking shall be located so that it is screened from surrounding streets by buildings, landscaping, and/or gateway features as dictated by location. Staff Comment: See discussion above. b. Structured Parking Garages: Intent: To promote more efficient use of land needed for vehicle parking; encourage the use of structured parking; physically and visually integrate parking garages with other uses; and reduce the overall impact of parking garages. Guidelines: Parking garages shall not dominate the streetscape; they shall be designed to be complementary with adjacent and abutting buildings. They shall be sited to complement, not subordinate, pedestrian entries. Similar forms, materials, and/or details to the primary building(s) should be used to enhance garages. ✓ Standard: Parking structures shall provide space for ground floor commercial uses along street frontages at a minimum of seventy five percent (75%) of the building frontage width. Staff Comment: The proposed structured parking area constitutes approximately 24% (120 feet / 485 feet = 0.24) of the building frontage width and therefore complies with the standard. Compliant if Condition of Approval is met Standard: The entire facade must feature a pedestrian-oriented facade. The Administrator of the Department of Community and Economic Development may approve parking structures that do not feature a pedestrian orientation in limited circumstances. If allowed, the structure shall be set back at least six feet (6') from the sidewalk and feature substantial landscaping. This landscaping shall include a City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 21 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL combination of evergreen and deciduous trees, shrubs, and ground cover. This setback shall be increased to ten feet (10') when abutting a primary arterial and/or minor arterial. Staff Comment: The integrated parking structure located at the southeast corner of the building is located below grade and is therefore not visible from the NE 10th ROW to the south and the majority of Jefferson Ave NE ROW to the east. The small portion visible from Jefferson St NE dead-end to the east of the site would be located approximately 50 feet from the ROW and would be screened via a mix of trees, shrubs, and groundcover that are a part of the perimeter parking lot area as indicated in the submitted schematic landscape plan (Exhibit 9). The submitted landscape plan did not identify the locations of individual shrubs or ground cover plants and therefore staff could not determine whether the proposed landscaping would adequately screen the structured parking. Therefore, staff recommends, as a condition of approval, the applicant shall submit a detailed landscape plan that identifies the pedestrian-scale landscaping requirements of RMC 4-3-100.E., including the species and spacing of individual plants, for the perimeter parking lot landscaping area near the southeast corner of the site. The landscape plan shall be submitted to and approved by the Current Planning Project Manager prior to civil construction permit approval. N/A Standard: Public facing facades shall be articulated by arches, lintels, masonry trim, or other architectural elements and/or materials. Staff Comment: The structured parking garage is located below grade and therefore does not have a public facing façade except for a small portion visible from the Jefferson Ave NE dead-end on the east side of the site due to the site sloping down and away from the ROW. ✓ Standard: The entry to the parking garage shall be located away from the primary street, to either the side or rear of the building. Staff Comment: The entrance to the parking garage is located on the back side of the building and does not face NE 10th St, the primary street. ✓ Standard: Parking garages at grade shall include screening or be enclosed from view with treatment such as walls, decorative grilles, trellis with landscaping, or a combination of treatments. Staff Comment: As discussed above, the parking garage is primarily enclosed from view by the rising topography of the site when moving northwest to southeast across the site. The small portion of the parking garage visible from Jefferson Ave NE to the east of the site would be screened by the proposed eight (8’) foot landscape strip in the ROW and proposed perimeter parking lot landscaping. N/A Standard: The Administrator of the Department of Community and Economic Development or designee may allow a reduced setback where the applicant can successfully demonstrate that the landscaped area and/or other design treatment meets the intent of these standards and guidelines. Possible treatments to reduce the setback include landscaping components plus one or more of the following integrated with the architectural design of the building: a. Ornamental grillwork (other than vertical bars); b. Decorative artwork; City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 22 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL c. Display windows; d. Brick, tile, or stone; e. Pre-cast decorative panels; f. Vine-covered trellis; g. Raised landscaping beds with decorative materials; or h. Other treatments that meet the intent of this standard... Staff Comment: Not applicable. c. Vehicular Access: Intent: To maintain a contiguous and uninterrupted sidewalk by minimizing, consolidating, and/or eliminating vehicular access off streets. Guidelines: Vehicular access to parking garages and parking lots shall not impede or interrupt pedestrian mobility. The impacts of curb cuts to pedestrian access on sidewalks shall be minimized. ✓ Standard: Access to parking lots and garages shall be from alleys, when available. If not available, access shall occur at side streets. Staff Comment: No alleys are abutting the property. The applicant provides one vehicle access driveway along Jefferson Ave NE near the rear of the site. The access point is located near the end of the road ROW and therefore would have a limited impact to the sidewalk and overall pedestrian experience. ✓ Standard: The number of driveways and curb cuts shall be minimized for vehicular access purposes, so that pedestrian circulation along the sidewalk is minimally impeded. Staff Comment: See above. 3. PEDESTRIAN ENVIRONMENT: Intent: To enhance the urban character of development in the Urban Center and the Center Village by creating pedestrian networks and by providing strong links from streets and drives to building entrances; make the pedestrian environment safer and more convenient, comfortable, and pleasant to walk between businesses, on sidewalks, to and from access points, and through parking lots; and promote the use of multi-modal and public transportation systems in order to reduce other vehicular traffic. a. Pedestrian Circulation: Intent: To create a network of linkages for pedestrians to improve safety and convenience and enhance the pedestrian environment. Guidelines: The pedestrian environment shall be given priority and importance in the design of projects. Sidewalks and/or pathways shall be provided and shall provide safe access to buildings from parking areas. Providing pedestrian connections to abutting properties is an important aspect of connectivity and encourages pedestrian activity and shall be considered. Pathways shall be easily identifiable to pedestrians and drivers. ✓ Standard: A pedestrian circulation system of pathways that are clearly delineated and connect buildings, open space, and parking areas with the sidewalk system and abutting properties shall be provided. a. Pathways shall be located so that there are clear sight lines, to increase safety. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 23 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL b. Pathways shall be an all-weather or appropriate permeable walking surface material, unless the applicant can demonstrate that the proposed surface is appropriate for the anticipated number of users and complementary to the design of the development. Staff Comment: The Site Plan (Exhibit 2) indicates a 5-foot wide concrete pedestrian pathway transitioning to an 8-foot wide concrete pedestrian from the two primary entrances and through the street frontage landscaping. The pathway is a direct connection approximately 15-feet long resulting in a clear sight line between the public sidewalk and the two entrances. Accessible pathways are provided from the sidewalks and parking lot to the building. Pathways from the parking lot are delineated with a change in texture. Sidewalks are eight-feet (8’) wide along NE 10th Street and six-feet (6’) wide along the western portion of Jefferson Avenue NE per City of Renton standards. Interior to the site, an accessible concrete pedestrian path through the surface parking area connects the building to the trash enclosure. ✓ Standard: Pathways within parking areas shall be provided and differentiated by material or texture (i.e., raised walkway, stamped concrete, or pavers) from abutting paving materials. Permeable materials are encouraged. The pathways shall be perpendicular to the applicable building facade and no greater than one hundred fifty feet (150') apart. Staff Comment: The Floor Plan (Exhibit 4) indicates a painted hatched area connecting the ADA stalls in the structured parking area with the concrete pedestrian walkway that is parallel to the building. Due to the constrained nature of the parking area, the applicant elected to provide a single walkway adjacent to the east building façade that weaves through the proposed memorial garden and connects to the public sidewalk in Jefferson Ave NE west of the building. Pedestrian access to the other portion of Jefferson Ave NE to the east of the site was determined to be infeasible due to the grade change and existing rockery wall located between the ROW and the parking area. ✓ Standard: Sidewalks and pathways along the facades of buildings shall be of sufficient width to accommodate anticipated numbers of users. Specifically: a. Sidewalks and pathways along the facades of mixed use and retail buildings 100 or more feet in width (measured along the facade) shall provide sidewalks at least 12 feet in width. The walkway shall include an 8-foot minimum unobstructed walking surface. b. Interior pathways shall be provided and shall vary in width to establish a hierarchy. The widths shall be based on the intended number of users; to be no smaller than five feet (5') and no greater than twelve feet (12'). c. For all other interior pathways, the proposed walkway shall be of sufficient width to accommodate the anticipated number of users. Staff Comment: As indicated on the Site Plan (Exhibit 2), all interior pathways have a minimum width of five (5’) feet. See additional discussion above. N/A Standard: Mid-block connections between buildings shall be provided. ✓ Standard: Permeable pavement pedestrian circulation features shall be used where feasible, consistent with the Surface Water Design Manual. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 24 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: Staff would review and consider permeable pavement if proposed with the civil construction permit application. b. Pedestrian Amenities: Intent: To create attractive spaces that unify the building and street environments and are inviting and comfortable for pedestrians; and provide publicly accessible areas that function for a variety of year- round activities, under typical seasonal weather conditions. Guidelines: The pedestrian environment shall be given priority and importance in the design of projects. Amenities that encourage pedestrian use and enhance the pedestrian experience shall be included. Compliant if Condition of Approval is met Standard: Architectural elements that incorporate plants, particularly at building entrances, in publicly accessible spaces and at facades along streets, shall be provided. Staff Comment: In order to further emphasize the prominence of the building’s primary entrances off of NE 10th St, the applicant has proposed a variety of landscaping elements concentrated at the southwest corner of the building including a seat wall with adjacent planting area, raised planters with small flowering trees, and multiple small planting strips where a mix of ground cover, shrubs, and trees are proposed. In order to provide additional pedestrian-scale landscape elements near the two primary entrances, staff recommends as a condition of approval the applicant incorporate additional raised planters or other architectural elements approved by the Current Planning Project Manager near the two primary front entrances off of NE 10th St in lieu of the proposed at-grade landscape strips shown on the conceptual landscape plan (Exhibit 9). Such elements shall be shown on the detailed landscape plan submitted with the civil construction permit to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Compliant if Condition of Approval is met Standard: Amenities such as outdoor group seating, benches, transit shelters, fountains, and public art shall be provided. a. Site furniture shall be made of durable, vandal- and weather-resistant materials that do not retain rainwater and can be reasonably maintained over an extended period of time. b. Site furniture and amenities shall not impede or block pedestrian access to public spaces or building entrances. Staff Comment: The applicant has seating options on the site including benches near the southwest plaza and memorial park. However, the applicant has not provided details of the exterior pedestrian amenities that are proposed. Therefore, staff recommends as a condition of approval the applicant submit details or manufacturers specifications with the detailed landscaping plan submitted with the civil construction permit for the proposed seat benches and other furniture shown on the Conceptual Landscape Plan (Exhibit 9). The site furniture and other sitting amenities shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit issuance. Compliant with intent and guidelines Standard: Pedestrian overhead weather protection in the form of awnings, marquees, canopies, or building overhangs shall be provided. These elements shall be a minimum of four and one-half feet (4-1/2') wide along at least seventy five percent (75%) of the length of the building facade facing the street, a maximum height of fifteen feet (15') above the ground elevation, and no lower than eight feet (8') above ground level. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 25 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: As indicated in the Architectural Elevations (Exhibit 3), primary entrance and exterior egress points would contain the 4.5-foot wide weather protection located approximately 11-feet above ground elevation. The weather protection canopy proposed over the primary RHA office entrance would extend west along the building façade and wrap around the southwest corner of the building in order to provide weather projection to the front plaza area. As designed, the building does not incorporate weather protection along at least 75% of the length of the building. However, canopies are provided above all primary and secondary entrances that face a public ROW and all pedestrian areas on the south and west sides of the building. The incorporation of awnings and canopies along 75-percent of the three facades that face a street would not complement the architecture of the building and may be detrimental to proposed foundation landscaping installed adjacent to the facade. Therefore, the amount of overhead weather protection proposed meets the intent of the guideline and would provide adequate protection from the elements for pedestrians access the primary or secondary entrance, or pedestrians utilizing the plaza near the southwest corner of the building. 4. RECREATION AREAS AND COMMON OPEN SPACE: Intent: To ensure that areas for both passive and active recreation are available to residents, workers, and visitors and that these areas are of sufficient size for the intended activity and in convenient locations. To create usable and inviting open space that is accessible to the public; and to promote pedestrian activity on streets particularly at street corners. Guidelines: Developments located at street intersections should provide pedestrian-oriented space at the street corner to emphasize pedestrian activity (illustration below). Recreation and common open space areas are integral aspects of quality development that encourage pedestrians and users. These areas shall be provided in an amount that is adequate to be functional and usable; they shall also be landscaped and located so that they are appealing to users and pedestrians ✓ Standard: All mixed use residential and attached housing developments of ten (10) or more dwelling units shall provide common opens space and/or recreation areas. a. At minimum, fifty (50) square feet per unit shall be provided. b. The location, layout, and proposed type of common space or recreation area shall be subject to approval by the Administrator. c. Open space or recreation areas shall be located to provide sun and light exposure to the area and located so that they are aggregated to provide usable area(s) for residents. d. For projects with more than one hundred (100) dwelling units, vegetated low impact development facilities may be used in required or provided open space where feasible and designed consistent with the Surface Water Design Manual. Such facilities shall be counted towards no more than fifty percent (50%) of the required open space. e. At least one of the following shall be provided in each open space and/or recreation area (the Administrator may require more than one of the following elements for developments having more than one hundred (100) units): i. Courtyards, plazas, pea patches, or multi-purpose open spaces; City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 26 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ii. Upper level common decks, patios, terraces, or roof gardens. Such spaces above the street level must feature views or amenities that are unique to the site and are provided as an asset to the development; iii. Pedestrian corridors dedicated to passive recreation and separate from the public street system; iv. Recreation facilities including, but not limited to, tennis/sports courts, swimming pools, exercise areas, game rooms, or other similar facilities; or v. Children’s play spaces that are centrally located near a majority of dwelling units and visible from surrounding units. They shall also be located away from hazardous areas such as garbage dumpsters, drainage facilities, and parking areas. f. The following shall not be counted toward the common open space or recreation area requirement: i. Required landscaping, driveways, parking, or other vehicular use areas. ii. Required yard setback areas. Except for areas that are developed as private or semi-private (from abutting or adjacent properties) courtyards, plazas or passive use areas containing landscaping and fencing sufficient to create a fully usable area accessible to all residents of the development. iii. Private decks, balconies, and private ground floor open space. iv. Other required landscaping and sensitive area buffers without common access links, such as pedestrian trails. Staff Comment: The applicant proposes 76 dwelling units and therefore 3,800 sq. ft. of common open space is required (76 units x 50 sq. ft. = 3,800 sq. ft). The applicant has proposed to provide common open space in excess of 50 sq. ft. per unit. The site plan and landscape plan (Exhibits 2 and 9) identify a memorial garden area on the north side of the site between the building and parking lot access drive. The garden area incorporates concrete walkways with connection to a central focal feature, raised mounds with seat walls, and a mix of ground cover, shrubs, and trees. The passive recreation area would provide approximately 2,800 sq. ft. of common open space. As shown on the site plan (Exhibit 2), the applicant also proposes a 3,500 sq. ft. second level outdoor terrace with adjoining 1,100 sq. ft. common room. The terrace area would include seating areas, a variety of vegetation and raised planters, and a tenant gardening area. Other ground floor amenity areas include built in seat benches in the public plaza adjacent to the southwest corner of building and substantial landscaped areas between the building and the Jefferson Ave NE ROW to the west of the building. The proposed common open spaces exceed minimum quantity requirements if they were required. In order to ensure the common open space elements meet the intent of the standard, which is provide usable and inviting open space that is accessible to the public, staff recommends as a condition of approval, the applicant shall submit details and manufacturers specifications for all common open space programming elements Landscape Plan (Exhibit 9). The details and specifications shall be identified on the detailed landscape plan to be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 27 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL N/A Standard: All buildings and developments with over thirty thousand (30,000) square feet of nonresidential uses (excludes parking garage floorplate areas) shall provide pedestrian-oriented space. a. The pedestrian-oriented space shall be provided according to the following formula: 1% of the site area + 1% of the gross building area, at minimum. b. The pedestrian-oriented space shall include all of the following: i. Visual and pedestrian access (including barrier-free access) to the abutting structures from the public right-of-way or a nonvehicular courtyard; and ii. Paved walking surfaces of either concrete or approved unit paving; and iii. On-site or building-mounted lighting providing at least four (4) foot- candles (average) on the ground; and iv. At least three (3) lineal feet of seating area (bench, ledge, etc.) or one individual seat per sixty (60) square feet of plaza area or open space. c. The following areas shall not count as pedestrian-oriented space: i. The minimum required walkway. However, where walkways are widened or enhanced beyond minimum requirements, the area may count as pedestrian-oriented space if the Administrator determines such space meets the definition of pedestrian-oriented space. ii. Areas that abut landscaped parking lots, chain link fences, blank walls, and/or dumpsters or service areas. d. Outdoor storage (shopping carts, potting soil bags, firewood, etc.) is prohibited within pedestrian-oriented space. Staff Comment: Not applicable. The proposed building contains approximately 13,645 square feet of non-residential uses. N/A Standard: Public plazas shall be provided at intersections identified in the Commercial Arterial Zone Public Plaza Locations Map and as listed below: a. Benson Area: Benson Drive S./108th Avenue S.E. and S.E. 176th. b. Bronson Area: Intersections with Bronson Way North at: i. Factory Avenue N./Houser Way S.; ii. Garden Avenue N.; and iii. Park Avenue N. and N. First Street. c. Cascade Area: Intersection of 116th Avenue S.E. and S.E. 168th Street. d. Northeast Fourth Area: Intersections with N.E. Fourth at: i. Duvall Avenue N.E.; ii. Monroe Avenue N.E.; and iii. Union Avenue N.E. e. Grady Area: Intersections with Grady Way at: i. Lind Avenue S.W.; City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 28 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ii. Rainier Avenue S.; iii. Shattuck Avenue S.; and iv. Talbot Road S. f. Puget Area: Intersection of S. Puget Drive and Benson Road S. g. Rainier Avenue Area: Intersections with Rainier Avenue S. at: i. Airport Way/Renton Avenue S.; ii. S. Second Street; iii. S. Third Street/S.W. Sunset Boulevard; iv. S. Fourth Street; and v. S. Seventh Street. h. North Renton Area: Intersections with Park Avenue N. at: i. N. Fourth Street; and ii. N. Fifth Street. i. Northeast Sunset Area: Intersections with N.E. Sunset Boulevard at: i. Duvall Avenue N.E.; and ii. Union Avenue N.E. N/A Standard: The plaza shall measure no less than one thousand (1,000) square feet with a minimum dimension of twenty feet (20') on one side abutting the sidewalk. N/A Standard: The public plaza must be landscaped consistent with RMC 4-4-070, including at minimum street trees, decorative paving, pedestrian-scaled lighting, and seating. Vegetated low impact development facilities may be used in the plaza where feasible and designed consistent with the Surface Water Design Manual. Such facilities shall count towards no more than fifty percent (50%) of the plaza requirement. 5. BUILDING ARCHITECTURAL DESIGN: Intent: To encourage building design that is unique and urban in character, comfortable on a human scale, and uses appropriate building materials that are suitable for the Pacific Northwest climate. To discourage franchise retail architecture. a. Building Character and Massing: Intent: To ensure that buildings are not bland and visually appear to be at a human scale; and ensure that all sides of a building, that can be seen by the public, are visually interesting. Guidelines: Building facades shall be modulated and/or articulated to reduce the apparent size of buildings, break up long blank walls, add visual interest, and enhance the character of the neighborhood. Articulation, modulation, and their intervals should create a sense of scale important to residential buildings. Compliant with intent and guidelines Standard: All building facades shall include modulation or articulation at intervals of no more than forty feet (40'). Staff Comment: As shown on the Architectural Elevations sheets (Exhibit 3), the building would contain a high parapet, canopies above all primary exterior doors, and expansive glazing along both the NE 10th St and Jefferson Ave NE ROWs. Two (2’) feet deep City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 29 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL modulated bays are provided along all ROW frontages and extend the entire height of the building. The applicant has departure from the standard in the form of a reduced articulation interval in order to allow the modulating bays to extend the full height of the building. According to the applicant, the interior design of the building necessitates using an alternative modulation interval and by utilizing the articulations at unit boundaries allows for easier framing and lower construction costs. The southwest corner of the building near the primary entrances utilizes a brick base on the first floor to help break down the corner and complement the wrap-around weather protection canopy. This frontage also includes expansive glazing with colored shades. The second floor terrace over the structured parking area provides a mass reducing vertical modulation. The glazing, contrast between light and dark tones, and use of both various fiber cement board textures including both panels and lap siding is human-scale and orients to the street. Staff concurs with the applicant that the other aesthetic elements are enough to help reduce the apparent size of the building and break the two long walls of the west and south wings and therefore meets the intent of the design guideline for the modulation and articulation standard. Compliant with intent and guidelines Standard: Modulations shall be a minimum of two feet (2') deep, sixteen feet (16') in height, and eight feet (8') in width. Staff Comment: The building façade provides regular modulations to the west along Jefferson Avenue NE and to the south along NE 10th Street in compliance with the Urban Design Regulations. While providing a full-height inset on both the northernmost and easternmost facades, the insets measure less than 8’ wide at 4’-10 ½“ and 5’-6 ½”, respectively. The applicant has requested a departure from the standard to allow for a reduced modulation width. According to the applicant, the inset at each façade uses color and window placement to create additional contrast from the main body to meet the intent of the design guideline. Staff concurs with the applicant and agrees that the proposal meets the intent of the design guideline for the modulation standard. Compliant if Condition of Approval is met Standard: Buildings greater than one hundred sixty feet (160') in length shall provide a variety of modulations and articulations to reduce the apparent bulk and scale of the facade; or provide an additional special feature such as a clock tower, courtyard, fountain, or public gathering area. Staff Comment: Both the south and west facades exceed 160 feet in length. While the proposed design of the modulating and articulating components do provide a high level of visual interest, they are not provided in a high enough frequency to effectively break up the two street-facing facades and reduce the bulk and scale of the building. Therefore, staff recommends as a condition of approval, the applicant shall submit revised elevation plans with the building permit application that shows a minimum of one (1) additional prominent corner feature such as a parapet extension, wrapped glazing, unique weather protection, and/or alternative elements approved by the Current Planning Project Manager. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. b. Ground-Level Details: Intent: To ensure that buildings are visually interesting and reinforce the intended human-scale character of the pedestrian environment; and ensure that all sides of a building within near or distant public view have visual interest. Guidelines: The use of material variations such as colors, brick, shingles, stucco, and horizontal wood siding is encouraged. The primary building entrance should be made visibly prominent by incorporating City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 30 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL architectural features such as a facade overhang, trellis, large entry doors, and/or ornamental lighting (illustration below). Detail features should also be used, to include things such as decorative entry paving, street furniture (benches, etc.), and/or public art. See FOF 19: Pedestrian Amenities Standard: Human-scaled elements such as a lighting fixture, trellis, or other landscape feature shall be provided along the facade’s ground floor. Staff Comment: Previous recommended conditions of approval would provide human scaled elements such as site furniture, lighting, and above landscaping elements in and around the facades ground floor. See FOF 19: Pedestrian Amenities for additional discussion. Compliant if Condition of Approval is met Standard: On any facade visible to the public, transparent windows and/or doors are required to comprise at least 50 percent of the portion of the ground floor facade that is between 4 feet and 8 feet above ground (as measured on the true elevation). Staff Comment: The ground floor of the south, west, north façades visible to the public contains expansive glazing in excess of the 50-percent requirement. However, glazing is limited on the east façade adjacent to the Jefferson Ave NE ROW. Therefore, staff recommends as a condition of approval, that the applicant submit a revised east elevation which includes a minimum of 50% glazing along the ground floor between 4 feet and 8 feet above ground on the wall of the structured parking garage, or, indicate on a revised elevation how the elevation meets the intent of the standard’s guidelines. Alternatively, the applicant may propose additional landscaping in front of the façade that would provide visual interest and mitigate the visual impact of the blank wall. The revised east elevation and/or landscape plan shall be submitted to and approved by the Current Planning Project Manager prior to building permit approval. ✓ Standard: Upper portions of building facades shall have clear windows with visibility into and out of the building. However, screening may be applied to provide shade and energy efficiency. The minimum amount of light transmittance for windows shall be 50 percent. Staff Comment: The second, third, and fourth stories contain a similar amount of glazing as the first floor. N/A Standard: Display windows shall be designed for frequent change of merchandise, rather than permanent displays. ✓ Standard: Where windows or storefronts occur, they must principally contain clear glazing. Staff Comment: The elevation sheets (Exhibit 3) indicate clear tempered glass along the façade. ✓ Standard: Tinted and dark glass, highly reflective (mirror-type) glass and film are prohibited. Staff Comment: No tinted, dark, or reflective glass is proposed. Compliant if Condition of Approval under FOF 19, Ground Level Detail is met Standard: Untreated blank walls visible from public streets, sidewalks, or interior pedestrian pathways are prohibited. A wall (including building facades and retaining walls) is considered a blank wall if: City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 31 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL a. It is a ground floor wall or portion of a ground floor wall over 6 feet in height, has a horizontal length greater than 15 feet, and does not include a window, door, building modulation or other architectural detailing; or b. Any portion of a ground floor wall has a surface area of 400 square feet or greater and does not include a window, door, building modulation or other architectural detailing. Staff Comment: As shown on the Architectural Elevations sheet (Exhibit 3) and discussed above, one untreated blank wall is proposed on the east façade. Staff recommended a condition of approval above that if met, would provide additional visual interest and reduce the “blank-wall” effect created by lack of features proposed on the portion of the east façade. Therefore, if the condition of approval is met, the elevation would meet the intent of the guidelines for ground-level detail. ✓ Standard: If blank walls are required or unavoidable, blank walls shall be treated with one or more of the following: a. A planting bed at least five feet in width containing trees, shrubs, evergreen ground cover, or vines adjacent to the blank wall; b. Trellis or other vine supports with evergreen climbing vines; c. Architectural detailing such as reveals, contrasting materials, or other special detailing that meets the intent of this standard; d. Artwork, such as bas-relief sculpture, mural, or similar; or e. Seating area with special paving and seasonal planting. Staff Comment: No untreated blank walls are proposed. c. Building Roof Lines: Intent: To ensure that roof forms provide distinctive profiles and interest consistent with an urban project and contribute to the visual continuity of the district. Guidelines: Building roof lines shall be varied and include architectural elements to add visual interest to the building. Compliant if Condition of Approval is met Standard: Buildings shall use at least one of the following elements to create varied and interesting roof profiles: a. Extended parapets; b. Feature elements projecting above parapets; c. Projected cornices; d. Pitched or sloped roofs e. Buildings containing predominantly residential uses shall have pitched roofs with a minimum slope of one to four (1:4) and shall have dormers or interesting roof forms that break up the massiveness of an uninterrupted sloping roof. Staff Comment: As shown on the Architectural Elevations (Exhibit 3), the building features a roof line with extended parapets varying in height above the roof level. A high parapet with varying color is proposed near the southwest corner to emphasize the primary entrance and provide an additional visual cue to direct visitors to the primary entrances. The roofline is primarily flat and does utilize the minimum slope identified in the standard, or one to four (1:4). A metal roof cap is proposed along the City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 32 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL top of the parapet but no cornicing is proposed and as such, the roofline lacks visual interest. Therefore, in order to comply with building roof line guidelines, staff recommends, as a condition of approval, the applicant shall provide one additional roof element that breaks up the massiveness of uninterrupted roof line and provide additional visual interest. The revised building elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. d. Building Materials: Intent: To ensure high standards of quality and effective maintenance over time; encourage the use of materials that reduce the visual bulk of large buildings; and encourage the use of materials that add visual interest to the neighborhood. Guidelines: Building materials are an important and integral part of the architectural design of a building that is attractive and of high quality. Material variation shall be used to create visual appeal and eliminate monotony of facades. This shall occur on all facades in a consistent manner. High quality materials shall be used. If materials like concrete or block walls are used they shall be enhanced to create variation and enhance their visual appeal. Compliant if conditions of approval are met Standard: All sides of buildings visible from a street, pathway, parking area, or open space shall be finished on all sides with the same building materials, detailing, and color scheme, or if different, with materials of the same quality. Staff Comment: The proposed building will be covered with fiber cement in different variations and colors including grey and orange (identified as ‘tangerine’) colored panels on the primary surfaces and navy lap siding in the articulating insets that spans the entire height of the building. Dark bronze anodized aluminum louvers are proposed along the top of ground floor windows to provide additional pedestrian-scale visual interest. A light grey brick veneer is proposed along portions of the first floor in order to provide an obvious contrast between the RHA offices on the first floor and upper level residences. The brick also reduces the perceived bulk of the building by creating a visual horizontal break in the façade wall. In order to ensure the brick veneer stands out from the grey fiber cement panels on some of the modulating façade elements, staff recommends as a condition of approval that the applicant utilize an alternative color scheme for the brick veneer. The applicant submitted revised elevation plans with the building permit application that shows an alternative brick color with higher contrast. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. In addition, to ensure the materials are of high quality, staff recommends as a condition of approval, the applicant submit a materials board with the building permit application that provides samples of exterior cladding materials that are proposed on the building. The materials board shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. ✓ Standard: All buildings shall use material variations such as colors, brick or metal banding, patterns or textural changes. Staff Comment: Texture changes including panels in multiple colors, lap siding, and first- floor brick veneer in addition to the bronze metal window shading elements provide material variations that complement and provide visual interest to the building. ✓ Standard: Materials, individually or in combination, shall have texture, pattern, and be detailed on all visible facades. Staff Comment: See discussion above. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 33 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ✓ Standard: Materials shall be durable, high quality, and consistent with more traditional urban development, such as brick, integrally colored concrete masonry, pre-finished metal, stone, steel, glass and cast-in-place concrete. Staff Comment: See discussion above. N/A Standard: If concrete is used, walls shall be enhanced by techniques such as texturing, reveals, and/or coloring with a concrete coating or admixture. N/A Standard: If concrete block walls are used, they shall be enhanced with integral color, textured blocks and colored mortar, decorative bond pattern and/or shall incorporate other masonry materials. ✓ Standard: All buildings shall use material variations such as colors, brick or metal banding, patterns, or textural changes. Staff Comment: See discussion above. 6. SIGNAGE: In addition to the City’s standard sign regulations, developments within Urban Design Districts C and D are also subject to the additional sign restrictions found in RMC 4 -4-100G, urban design sign area regulations. Modifications to the standard requirements found in RMC 4-4-100G are possible for those proposals that can comply with the Design District criteria found in RMC 4-3-100F, Modification of Minimum Standards. For proposals unable to meet the modification criteria, a variance is required. Compliance not yet demonstrated Standard: Signage shall be an integral part of the design approach to the building. Staff Comment: The applicant has proposed conceptual signage as shown in the Color Renderings (Exhibit 5) provided with application. Signage proposed includes two ground monument signs incorporated into seat walls near the primary front entrance, as well as a large projection sign above the residential entrance. Signage standards will be reviewed for compliance with the sign permit application. ✓ Standard: In mixed use and multi-use buildings, signage shall be coordinated with the overall building design. Staff Comment: The proposal includes separate signage for both the RHA on-site service as well as for residential portion of the project. The proposed signage is well integrated into the site design and aesthetic character of the building. Signage standards will be reviewed for compliance with the sign permit application. N/A Standard: Corporate logos and signs shall be sized appropriately for their location. Staff Comment: Not applicable. No corporate signage proposed. N/A Standard: Entry signs shall be limited to the name of the larger development. Staff Comment: Not applicable. The proposal is for a single use building. N/A Standard: Alteration of trademarks notwithstanding, corporate signage should not be garish in color nor overly lit, although creative design, strong accent colors, and interesting surface materials and lighting techniques are encouraged. Staff Comment: Not applicable. No corporate signage proposed. Compliance not yet demonstrated Standard: Front-lit, ground-mounted monument signs are the preferred type of freestanding sign. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 34 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: The applicant has proposed two ground-mounted monument signs with unknown lighting type. Signage standards and associated lighting methods will be reviewed for compliance with the sign permit application. Compliance not yet demonstrated Standard: Blade type signs, proportional to the building facade on which they are mounted, are encouraged on pedestrian-oriented streets. Staff Comment: As shown in the Color Renderings (Exhibit 5), the applicant has proposed a large projecting blade-type sign to identify the name of the project, Sunset Gardens, on the façade facing NE 10th St. The sign dimensions were not shown on the drawings, but appear to be proportional to the overall building scale. Signage standards will be reviewed for compliance with the sign permit application. Compliance not yet demonstrated Standard: All of the following are prohibited: a. Pole signs; b. Roof signs; and c. Back-lit signs with letters or graphics on a plastic sheet (can signs or illuminated cabinet signs). Exceptions: Back-lit logo signs less than ten (10) square feet are permitted as area signs with only the individual letters back-lit (see illustration, subsection G8 of this Section). Staff Comment: No pole, roof, or back-lit signs were proposed as part of the application. Signage standards will be reviewed for compliance with the sign permit application. Compliance not yet demonstrated Standard: Freestanding ground-related monument signs, with the exception of primary entry signs, shall be limited to five feet (5') above finished grade, including support structure. Staff Comment: The height of the two freestanding monument signs is not indicated on the plans, but both heights appear to be under five feet (5’) above finished grade. Signage standards will be reviewed for compliance with the sign permit application. Compliance not yet demonstrated Standard: Freestanding signs shall include decorative landscaping (ground cover and/or shrubs) to provide seasonal interest in the area surrounding the sign. Alternately, signage may incorporate stone, brick, or other decorative materials as approved by the Director. Staff Comment: As indicated in the Landscape Plan (Exhibit 9) and Color Rendering (Exhibit 5), meaningful landscaping is proposed in front of both freestanding signs. Specific plant species and their locations will be required to be identified on the final landscape plan submitted at the time of building permit application. Signage standards will be reviewed for compliance with the sign permit application. 7. LIGHTING: Intent: To ensure safety and security; provide adequate lighting levels in pedestrian areas such as plazas, pedestrian walkways, parking areas, building entries, and other public places; and increase the visual attractiveness of the area at all times of the day and night. Guidelines: Lighting that improves pedestrian safety and also that creates visual interest in the building and site during the evening hours shall be provided. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 35 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Compliant if condition of approval is met Standard: Pedestrian-scale lighting shall be provided at primary and secondary building entrances. Examples include sconces on building facades, awnings with down-lighting and decorative street lighting. Staff Comment: No lighting information was provided by the applicant with the land use application. Therefore, staff recommends, as a condition of approval, the applicant shall submit a lighting plan with the building permit application that adequately provides for public safety and creates visual interest to the building and site. Pedestrian scaled lighting shall be provided at the primary entrance and accent lighting on building facades. The parking area shall also contain adequate lighting to ensure safety and security. The lighting plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Compliance not yet demonstrated Standard: Accent lighting shall also be provided on building facades (such as sconces) and/or to illuminate other key elements of the site such as gateways, specimen trees, other significant landscaping, water features, and/or artwork. Staff Comment: See discussion above. Compliance not yet demonstrated Standard: Downlighting shall be used in all cases to assure safe pedestrian and vehicular movement, unless alternative pedestrian scale lighting has been approved administratively or is specifically listed as exempt from provisions located in RMC 4-4- 075, Lighting, Exterior On-Site (i.e., signage, governmental flags, temporary holiday or decorative lighting, right-of-way-lighting, etc.). Staff Comment: See discussion above. 20. Site Plan Review: Pursuant to RMC 4-9-200.B, Site Plan Review is required for development in the CV zoning classification when it is not exempt from Environmental (SEPA) Review. For Master Plan applications compliance with the review criteria for Site Plans are analyzed at a general level of detail to ensure nothing would preclude the development of the Site Plan. Given Site Plan applications are evaluated for compliance with the specific requirements of the RMC 4-9-200.E.3 the following table contains project elements intended to comply with level of detail needed for Site Plan requests: Compliance Site Plan Criteria and Analysis Compliant if conditions of approval are met a. Comprehensive Plan Compliance and Consistency. Staff Comment: See previous discussion under FOF 17, Comprehensive Plan Analysis. Compliant if conditions of approval are met b. Zoning Compliance and Consistency. Staff Comment: See discussion under FOF 18, Zoning Development Standard Compliance. Compliant if conditions of approval are met c. Design Regulation Compliance and Consistency. Staff Comment: See discussion under FOF 19, Design District Review. ✓ d. Planned action ordinance and Development agreement Compliance and Consistency. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 36 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: The Environmental Review Committee issued a concurrence memo (Exhibit 1) indicating the proposal is consistent with the Sunset Area Planned Action Ordinance and qualifies as a planned action. No development agreement is associated with this project. Compliant if Condition of Approval under FOF 19, Lighting is met e. Off-site Impacts. Structures: Restricting overscale structures and overconcentration of development on a particular portion of the site. Staff Comment: The proposed building is four stories and generally consistent with the scale of existing buildings in the commercial area in the surrounding Sunset neighborhood. A three-story apartment building across NE 10th St and a four-story across Jefferson Ave NE are of similar size and scale to the proposed development. The building includes pedestrian-scale features along all frontages and is oriented to the abutting streets. See also FOF 19, Design District Review: Building Character and Massing. Circulation: Providing desirable transitions and linkages between uses, streets, walkways and adjacent properties. Staff Comment: The applicant is proposing to access the ground level parking via a single curb cut off of Jefferson Ave NE. Site improvements include a new 8-foot wide sidewalk along NE 10th St, a new 6-foot wide sidewalk along Jefferson Ave NE, and two at grade entrance points for both the RHA offices on the ground floor and the residences above. Extensive weather protection and a plaza at the southwest corner of the building result in an enhanced pedestrian experience for visitors or passersby. Utilities, Loading and Storage Areas: Locating, designing and screening storage areas, utilities, rooftop equipment, loading areas, and refuse and recyclables to minimize views from surrounding properties. Locate utilities underground consistent with RMC 4-6-090. Staff Comment: The proposed refuse and recycle area is located towards the rear of the site behind the west wing of the structure in a full enclosure to be constructed with high quality materials that are consistent with those used on the primary structure. The location and design of the enclosure results in limited view impacts to neighbors and passersby. The addition of a metal roof for the enclosure further limits the visual impacts by ensuring that neighboring properties at higher elevations cannot see down into the structure. See FOF 18, Zoning Development Standards: Refuse and Recycling and Screening. Views: Recognizing the public benefit and desirability of maintaining visual accessibility to attractive natural features. Staff Comment: There are no significant views for which to maintain visual accessibility and staff received no comments from adjacent properties regarding views. New territorial views to the south and west would be available to residents in the new development. Landscaping: Using landscaping to provide transitions between development and surrounding properties to reduce noise and glare, maintain privacy, and generally enhance the appearance of the project. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 37 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: The applicant would provide the required 10-foot wide street frontage landscaping along NE 10th St and Jefferson Ave NE. The applicant has also proposed a heavily landscaped memorial garden area at the rear of the building and a second floor terrace with incorporated planter boxes that will help reduce the scale of building and increase privacy for both residents and neighbors (see Exhibit 9 . See also discussion under FOF 18, Zoning Development Standard: Landscaping. Lighting: Designing and/or placing exterior lighting and glazing in order to avoid excessive brightness or glare to adjacent properties and streets. Staff Comment: A lighting plan was not provided with the application; therefore staff recommended as condition of approval that a lighting plan be provided at the time of building permit review (See Lighting discussion under FOF 19, Design District Review: Lighting). ✓ f. On-site Impacts. Structure Placement: Provisions for privacy and noise reduction by building placement, spacing and orientation. Staff Comment: The building provides privacy and noise reduction as a large number of units are oriented towards Jefferson Ave NE, a dead-end road that provides access to the adjacent apartments and commercial uses to the west and north of the site. The exterior common spaces are located behind the building and away from the busier NE 10th St. There are also no occupied roof decks above the second level that could project noise over the adjacent buildings to the larger neighborhood. All noise from exterior common spaces at ground level would be limited and contained by hardscape and landscape features such as planter boxes, trees and weather protection canopies. Structure Scale: Consideration of the scale of proposed structures in relation to natural characteristics, views and vistas, site amenities, sunlight, prevailing winds, and pedestrian and vehicle needs. Staff Comment: The proposed building would be “L” shaped with an outdoor second- story terrace area located on the backside of the building. This design would provide the maximum amount of natural sunlight to both the outdoor common spaces and the residential units above. The other large common open space, a memorial park near the northwest corner of the site, is located behind west wing of the building and has plentiful access to sunlight due to the orientation of the building. Parking is concentrated between the two wings and provides adequate vehicular access to the site while remaining mostly hidden from the abutting streets. Natural Features: Protection of the natural landscape by retaining existing vegetation and soils, using topography to reduce undue cutting and filling, and limiting impervious surfaces. Staff Comment: Moderate cutting is proposed on the site in order to utilize the slope of the site to screen the structured parking and provide a better pedestrian experience (Exhibit 10). Most of the existing vegetation on the subject property will be removed during construction, however, the development would result in a significant number of street trees and new ground level landscaping including at grade shrubs and trees as well as above grade planter boxes. Reducing Parking Impervious Areas: Design parking areas to minimize impervious surfaces, including but not limited to: (1) breaking up parking areas and directing City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 38 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL stormwater flows to multiple low impact development features such as bioretention areas; (2) locating parking near trees to provide storm water uptake; (3) retaining or adding vegetation to parking areas; (4) placing existing parking that exceeds maximum parking ratios in permeable pavement designed consistent with the Surface Water Design Manual in RMC 4-6-030; and (5) using other low impact development techniques consistent with RMC 4-6-030. Staff Comment: The applicant has minimized parking impervious areas by providing a portion of the parking stalls under the second floor of the building. In addition, the applicant has proposed adequate interior and perimeter landscaping that will allow for rainwater infiltration in the surface parking area. The parking lot landscaping will include new trees, shrubs, and ground cover that will reduce the amount of water entering the public storm water conveyance system. Landscaping: Use of landscaping to soften the appearance of parking areas, to provide shade and privacy where needed, to define and enhance open spaces, and generally to enhance the appearance of the project. Landscaping also includes the design and protection of planting areas so that they are less susceptible to damage from vehicles or pedestrian movements. Staff Comment: The surface parking area will be screened by the east wing of the building abutting NE 10th St as well as the frontage landscaping along Jefferson Ave NE. Perimeter landscaping is also proposed along a portion of the parking lot between the sidewalk in the Jefferson Ave NE ROW and the stalls. The memorial garden area will include mounded planted areas incorporated with small flowering trees, shrubs, and ground cover and will provide significant visual interest in addition to screening a small portion of the parking lot from the Jefferson Ave NE ROW. Curbing installed in the parking lot will help prevent the potential the planting areas to be damaged by vehicles access the parking lot. See also FOF 18, Zoning Development Standard: Landscaping. Compliant if Conditions of Approval are met g. Access and Circulation. Location and Consolidation: Providing access points on side streets or frontage streets rather than directly onto arterial streets and consolidation of ingress and egress points on the site and, when feasible, with adjacent properties. Staff Comment: The applicant will provide a single driveway for the development located on Jefferson Ave NE, a dead end street that provides access to multiple adjacent properties. The proposal promotes safe and efficient circulation through a single access point. Internal Circulation: Promoting safety and efficiency of the internal circulation system, including the location, design and dimensions of vehicular and pedestrian access points, drives, parking, turnarounds, walkways, bikeways, and emergency access ways. Staff Comment: The applicant has consolidated the vehicle access to one driveway on Jefferson Ave NE. Vehicles within the internal parking lot are provided with adequate driveway aisles for maneuvering in and out of the lot. Pedestrian connections from the street to the primary and secondary building entrances will be provided as well as a concrete pathway adjacent to the parking area that will provide safe passage for pedestrians accessing the outdoor park area or secondary entrances. Emergency vehicle City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 39 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL access can be accommodated via the two abutting streets. See Location and Consolidation discussion above and Pedestrian discussion below. Loading and Delivery: Separating loading and delivery areas from parking and pedestrian areas. Staff Comment: Due to the nature of the proposed uses, frequent large deliveries will not likely occur. Loading and delivery would be available on Jefferson Ave NE on the west side of the building where traffic is minimal due to the dead-end nature of the street. Onsite loading and delivery access could also be provided in the surface parking accessed via Jefferson Ave NE. No information or stripping was designated for loading and delivery onsite. If a separate loading and delivery area from parking and pedestrian areas is proposed onsite, the applicant may include the loading and delivery area details with the civil construction plan for review. Transit and Bicycles: Providing transit, carpools and bicycle facilities and access. Staff Comment: Per RMC 4-4-080F.11.a bicycle parking spaces are required at 10% of the number of required off-street parking spaces for the RHA on-site service and 0.5 spaces per unit for the residential uses. The applicant has proposed a total of 45 bicycle parking spaces for the development including 40 in a separate room contained within the structured parking garage and five (5) in front of the building’s primary entrance on Jefferson Ave NE. See FOF 18, Zoning and Development Standards: Bicycle Parking. A transit stop is located abutting the subject property on NE 10th St. The stop services King County Metro route 111 which provides service between Lake Kathleen and downtown Seattle. In order to avoid conflicts with the transit stop during site development, staff recommends as a condition of approval that the applicant coordinate with King County Metro prior to submitting construction permits to identify any needed accommodations for the abutting transit stop on NE 10th St that need to occur during construction of the site. Evidence of the coordination with King County Metro and the accommodation(s) shall be shown on the civil construction permit plans to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Pedestrians: Providing safe and attractive pedestrian connections between parking areas, buildings, public sidewalks and adjacent properties. Staff Comment: The applicant will provide a pedestrian connection from the NE 10th St public sidewalk to the two primary entries and a walkways adjacent to the parking lot. The applicant will also provide a new 8-foot wide sidewalk and street trees along NE 10th St and a new 6-foot wide sidewalk with street trees along Jefferson Ave NE. In order to ensure the proposed pedestrian connections, including both walkways and plaza areas, are differentiated from other surfaces on the site and provide a safe connection, staff recommends, as a condition of approval, that the paving material used for the proposed onsite plaza and pedestrian circulation areas be scored concrete and that the connections in the parking lot be constructed of concrete or comparable alternative material. The scoring and material composition of the interior pedestrian pathways and plaza areas shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit approval. See also FOF 19, Design District Review for additional analysis City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 40 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ✓ h. Open Space: Incorporating open spaces to serve as distinctive project focal points and to provide adequate areas for passive and active recreation by the occupants/users of the site. Staff Comment: The applicant proposes an exterior memorial garden area near the rear of building and a second-floor outdoor terrace area. Both areas will include seating for residents and visitors and will provide quiet spaces for passive recreation. Interior common spaces include a first-floor lobby and second-floor common room adjacent to the outdoor terrace (Exhibits 2 and 3). ✓ i. Views and Public Access: When possible, providing view corridors to shorelines and Mt. Rainier, and incorporating public access to shorelines Staff Comment: Existing view corridors should not be impacted. New views may be possible from the upper story of the building. The public access requirement is not applicable to the proposal. ✓ j. Natural Systems: Arranging project elements to protect existing natural systems where applicable. Staff Comment: The site was previously developed with a one-story building housing RHA offices. Existing natural systems are limited to the vegetated area along and trees along the street frontages. Therefore, limited natural systems are available on the site. ✓ k. Services and Infrastructure: Making available public services and facilities to accommodate the proposed use: Police and Fire. Staff Comment: Police and Fire Prevention staff indicated that sufficient resources exist to furnish services to the proposed development, if the applicant provides Code required improvements and fees. A Fire Impact Fee, based on amount per square foot per the City of Renton Fee Schedule in effect at the time of building permit application submittal would be applicable to the proposal. A minimum of three fire hydrants are required including one within 150-feet and two within 300-feet of the building. A looped water main is required to serve the site due to the fire flow demand exceeding 2,500 gallons per minute. Schools: It is anticipated that the Renton School District can accommodate any additional students generated by this proposal at the following schools: Highlands Elementary School, McKnight Middle School, and Hazen High School. Except for the elementary school students, any new students from the proposed development would be bussed to their schools. The school bus stop is located approximately 0.3 miles from the project site at NE 9th St and Harrington Ave NE (NW corner). The proposed project includes the installation of frontage improvements along the NE 10th St project frontage, including sidewalks. All students would walk east along NE 10th St, south along Kirkland Ave NE, and west along NE 9th St to access the bus stop. Existing sidewalks are available for the entire route on both sides of the street and marked crosswalks are available at all intersections where street crossings are necessary. Elementary school students would access Highlands Elementary School using the same route. A School Impact Fee, based on the City of Renton Fee Schedule would be applicable to the proposal. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 41 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Water and Sewer. Staff Comment: Water service is provided by City of Renton. It has been determined that the preliminary fire flow demand for the proposed development is 3,000 gallons per minutes (gpm). A looped water main around the building is required around the building due to fire flow demand exceeding 2,500 gpm. There is a 6-inch water main on the north side of NE 10th St for the portion south of the project site and on the east side of Jefferson Ave NE for the portion west of the site that can provide a maximum flow capacity of 1,600 gpm. There is an 8-inch water main in Jefferson Ave NE west, north, and east of the site that can provide a maximum flow capacity of 1,600 gpm. Lastly, there is a 12- inch water stub ending at the southeast corner of the NE Sunset Boulevard and NE 10th St that can provide a maximum flow capacity of 2,800 gpm. The applicant has proposed water main extensions in Jefferson Ave NE and NE 10th St to complete the looped main system and provide the required fire-related improvements. Installation of one new fire hydrant is proposed along the NE 10th St frontage approximately 52 feet from the proposed fire department connection (FDC). A fire hydrant is required within 50 feet of the FDC. Sewer service is provided by the City of Renton. There is an existing 8-inch lined concrete sewer to the north of the site in Jefferson Ave NE. All new building side sewers shall be a minimum of 6-inches and shall run at a slope of at least 2-percent to the main. Drainage from all parking under cover and any floor drains inside the building shall be routed to the sanitary sewer system after passing through a City approved commercial grade oil/water separator such as an inverted tee in a type 1 catch basin. The development is subject to current water and wastewater system development fees. Drainage. Staff Comment: The site is within the City’s Peak Rate Flow Control Standard (Existing Conditions) and is within the East Lake Washington Drainage Basin. The applicant’s drainage analysis (Exhibits 11 and 12) has indicated a flow control facility, such as a vault, would not be required to comply with the Renton Surface Water Design Manual. The report indicates the on-site site catch basins would discharge stormwater into an existing 12-inch stormwater main in the Jefferson Ave NE ROW as well as an existing 12-inch stormwater main in NE 10th St ROW. However, the site would be required to provide Best Management Practices meeting enhanced basic water quality standards for new pollution-generated surfaces. The applicant has proposed to provide limited infiltration for the new pollution generating impervious surfaces via two bioretention planters to be installed on-site between the building’s west façade and the Jefferson Ave NE ROW. Due to the applicant proposing to locate the planters partially within the on-site 10-foot landscape strip, staff recommended as a condition of approval under FOF 18, Zoning Standards: Landscaping that the applicant located the planters outside of required 10-foot landscape strip. While staff recognizes the importance of providing Best Management Practices for improved water quality, it cannot come at the expense of reducing landscape elements that reduce the development’s impact on the neighborhood. The applicant’s analysis has indicated the amount of pollution generating impervious surface would exceed 5,000 sq. ft. for the redeveloped site and therefore would not be exempt from providing water quality treatment. Final review for compliance with the City’s stormwater requirements would occur during the civil construction permit phase. The development is subject to the current surface water system development fee. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 42 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Transportation. Staff Comment: The proposed development fronts Jefferson Avenue NE along the west, north, and east property lines. Access to the site is proposed via a single driveway located along Jefferson Ave NE. The segment of Jefferson Avenue NE to the east of the site is classified as a residential access street and the segment of Jefferson Ave NE west of the site is classified as a commercial access street with an existing ROW width of 50 feet. The minimum ROW width for a residential access street is 53 feet and requires a pavement width of 26-feet, a 0.5-foot curb, an 8-foot planting strip, and a 5-foot sidewalk. The applicant would be required to dedicate 1.5-foot dedication along this section of Jefferson Avenue NE and construct the required improvements. The minimum ROW width for a commercial access street is 69 feet and requires a pavement width of 36-feet, a 0.5-foot curb, an 8-foot planting strip, and a 6-foot sidewalk. Dedication to fit these improvements within the public ROW will be required, pending field survey. The proposed development also fronts NE 10th Street along the south property line. NE 10th Street is classified as a collector arterial with an existing ROW width of 60 feet. The minimum ROW width for a collector arterial with 2 lanes is 83-feet and the minimum paved roadway width is 46-feet. The paved roadway section consists of two 10-foot travel lanes, two 8-foot parking lanes, and two 5-foot bike lanes, a 0.5-foot curb, 8-foot planter strip, and 8-foot sidewalk are required along both sides of the pavement. Two feet of clear space behind the sidewalk is required along both sides of the roadway. Dedication to accommodate this street section will be required. City staff has reviewed this portion of NE 10th St and would recommend approval of a modification (see FOF 26, Street Modification Analysis) to have the applicant retain the existing pavement width and construct the required 8-foot planter, 8-foot sidewalk, 0.5-foot curb, and 2-foot clear space behind the current curb line along the subject property’s frontage. Dedication to fit these improvements within public ROW will be required, pending field survey. Increased traffic created by the development would be mitigated by payment of transportation impact fees. A Transportation Impact Fee, based on the City of Renton Fee Schedule would be applicable to the proposal. The proposal has passed the City’s Traffic Concurrency Test per RMC 4-6-070.D (Exhibit 16), which is based upon a test of the citywide Transportation Plan, consideration of growth levels included in the LOS-tested Transportation Plan, and future payment of appropriate Transportation Impact Fees. N/A l. Phasing: The applicant is not requesting any additional phasing. ✓ m. Stormwater: Providing optimal locations of stormwater infiltrating low impact development facilities. Avoiding placement of buildings or impervious areas on soils with infiltration capability to the maximum extent practicable. Staff Comment: The applicant proposes the building to be located on existing impervious surfaces. Limited infiltration is proposed via three bioretention filters to be installed between the building and Jefferson Ave NE on the west side of the property (Exhibit 9). In addition, plentiful landscaping around the building perimeter, within the surface parking lot area, and in the outdoor garden area will provide additional opportunities for infiltration. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 43 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL 21. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations, if all conditions of approval are complied with: Compliance Critical Areas Analysis Compliant if condition of approval is met Geologically Hazardous Areas: Based upon the results of a geotechnical report and/or independent review, conditions of approval for developments may include buffers and/or setbacks from buffers. A standard 15-foot building setback is required for all structures from Protected Slope areas. A 50-foot buffer and 15-foot building setback are required from Very High Landslide Hazard Areas. Staff Comment: The City’s COR maps has identified the site containing a Moderate Landslide Hazard Area and Sensitive Slopes (15-40%). As such, the applicant submitted an Updated Geotechnical Report prepared by Otto Rosenau and Associates, Inc and dated April 16, 2021 (Exhibit 13). The applicant’s geotechnical engineer completed a geotechnical exploration via two test borings on August 17, 2020. The geotechnical engineer anticipates that the western portion of the proposed structure may be supported with a conventional foundation system and the southeast portion of the proposed structure may be supported by deep foundation elements such as driven piles, provided the recommendations presented in the report are followed. In addition, the geotechnical engineer anticipates that proposed development would not have adverse impacts on adjacent properties provided the same recommendations are followed. The applicant’s geotechnical engineer found that soil erosion potential at this project site can be reduced through the provision of normal erosion control measures include such items as fences, hay bales, mulching, control ditched and diversion trenches. The applicant’s geotechnical engineer recommends that temporary slopes be no greater than 1.5H:1V and that temporary soldier pile and lagging shoring be installed in areas where significant cutting of materials occurs near existing sidewalk and roadways. The engineer makes specific recommendations with respect to the foundation, one of the most important of which is the removal of any organic material or unsuitable soils according to the report. Foundation options for the structure include slab-on-grade, driven pin piles, and conventional footings depending on the section of building being designed for. Therefore in order to ensure the recommendations of the geotechnical report or future addenda are implemented, staff recommendations as a condition of approval, the applicant shall comply with the recommendations of the geotechnical report prepared by Otto Rosenau & Associates, dated April 16, 2021 or future addenda. 22. Variance Analysis: The applicant is requesting a variance from RMC 4-2-120.A to allow a portion of the surface parking lot to be located between the building and the public street. Per RMC 4-2-110.A, Parking, parking for residential and commercial uses in the CV zone may not be located between the building and a public street unless located within a structured parking garage. The applicant is requesting relief from the code section in order to allow approximately eleven (11) parking stalls to be located in the area between Jefferson Ave NE ROW abutting the east side of the site. The applicant’s justification for the requested variance is that the site’s unique curvature of the northeast property line and the presence of ROW abutting three sides of the site necessitates locating a portion of the parking lot between the building and City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 44 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL the ROW. The proposal is compliant with the following variance criteria, pursuant to RMC 4-9-190I.4. Therefore, staff recommends approval of the requested variance. Compliance Variance Criteria and Analysis ✓ a. That the applicant suffers practical difficulties and unnecessary hardship and the variance is necessary because of special circumstances applicable to subject property, including size, shape, topography, location or surroundings of the subject property, and the strict application of the Zoning Code is found to deprive subject property owner of rights and privileges enjoyed by other property owners in the vicinity and under identical zone classification. Staff Comment: The applicant contends that due to the unique curvature of the site along the eastern and northern property lines where the surface parking lot is located, a portion of the surface parking stalls would be located between the Jefferson Ave NE and the building. The design of the building which is located along the entire NE 10th St ROW allows the majority of the parking to be tucked behind the building, but leaves approximately eleven (11) stall exposed to Jefferson Ave NE due to the curvature of the northeast property line. According to the applicant, locating the surface parking lot at the back of the site near the curved property line was the only viable option for a site bounded by ROWs on three sides and results in a small number of stalls between the building and street. Therefore the applicant concludes that the parking lot location standard is difficult to implement in abnormally-shaped lots with a significant amount of abutting ROW. Staff concurs with the applicant’s justification and finds that the applicant suffers practical difficulties and unnecessary hardship and the variance is necessary due to the unique shape of the site. ✓ b. That the granting of the variance will not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity and zone in which subject property is situated. Staff Comment: The applicant contends that the granting of the variance would not negatively impact public welfare or neighboring properties in the vicinity due to the portion of the surface parking lot between the building and the street is mostly hidden from view due to the substantial grade change created by an existing 12-foot tall rockery wall abutting the east property line. According to the applicant, the grade change created by the site’s topography combined with the amble landscaping proposed as part of both the planter strip and on-site perimeter parking lot landscaping will substantially screen the surface parking lot from view and limit impacts to neighboring properties. Staff concurs with the applicant’s justification and finds that the proposed location of the surface parking lot between the building and street would not be materially detrimental to the public welfare or injurious to other properties in the vicinity. ✓ c. That approval shall not constitute a grant of special privilege inconsistent with the limitation upon uses of other properties in the vicinity and zone in which the subject property is situated. Staff Comment: The proposal does not constitute a grant of special privilege as the proposed location of the surface parking lot is only justifiable due to the unique shape of the lot and is necessary as a result of the ROW abutting three sides of the site. In addition, the surface parking is mostly hidden from you due to the higher grade of the street and the applicant’s proposal for significant on0site landscaping to the west of the City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 45 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL existing retaining wall. The applicant will also be required to install an 8-foot (8’) wide planter strip as part of the Jefferson Ave NE improvements which will provide an additional screening element. ✓ d. That the approval is a minimum variance necessary that will accomplish the desired purpose. Staff Comment: According to the applicant, the requested variance is the minimum necessary to provide the number of parking stalls needed for the residential and on-site uses. By approving a variance to allow for a portion of the stalls to be located between the building and the street, the applicant can provide the number of stalls necessary per their anticipated parking demand while providing ensuring the area is adequately screened through the use of landscaping and site topography. Staff concurs with the applicant that the approval is minimum relief necessary that will accomplish the desired purpose. 23. Parking Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9-250D, the applicant is requesting a Modification from four subsections in RMC 4-4-080 Parking, Loading, and Driveway Regulations: a) RMC 4-4-080.F.8.a, Standard Parking Stall Size for Surface/Private Garage/Carport: The applicant requests a modification to reduce the minimum size of the standard surface parking stalls from 20- feet by 9-feet to 15-feet x 8-feet. b) RMC 4-4-080.F.8.c, Compact Parking Stall Size and Maximum Number of Compact Spaces: The applicant is requesting a modification to reduce the minimum size of the surface compact parking stalls from 8.5-feet by 16-feet to 7.5 feet x 12-feet and a modification to exceed the maximum percentage of compact spaces allowed by 11%. c) RMC 4-4-080.F.9.b, Ninety Degree Parking Aisle Minimums: The applicant is requesting a modification to allow for a 22-foot parking aisle width for a portion of the surface parking lot. d) RMC 4-4-080.F.11.b and 4-4-080.F.11.c, Bicycle Parking Standards: The project requests a modification to the type of bicycle rack provided to allow a portion of the racks to be wall-mounted. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9-250D, if all conditions of approval are met. Therefore, staff is recommending approval of the requested modification as noted below: Compliance Parking Modification Criteria and Analysis ✓ a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support flexible street grid and pathway patterns, and are visually attractive, safe, and healthy environments. The requested off-street parking modification is consistent with these policy guidelines. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 46 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL The applicant contends that the intent of the proposed modification, specifically requests ‘a)’, ‘b)’, and ‘c)’ was to provide enough parking onsite to minimize impacts to the surrounding residential neighborhood. According to the applicant, designing the parking on a site abutting three ROWs and with an irregular shape proved challenging and necessitates relief from multiple dimensional standards in order to provide enough spaces to meet the demand of the residential and on-site uses. With respect to the part of the request related to bicycle parking, noted under ‘d)’ above, the applicant reasons that including both wall-mounted and floor-mounted bicycle racks provides a variety of locking solutions while minimizing the footprint of the indoor bicycle enclosure. In addition, the applicant is able to provide more bicycle stalls than required due to the space-saving design of the wall-mounted racks. The applicant contends that the approach is consistent with the land use and design policies in the City’s Comprehensive Plan, which encourages high quality infill projects that consider the impacts on adjacent properties and provides mitigation for those impacts. Approval of the modification would ensure adequate vehicular and bicycle parking is located on the site and reduce the overall impact on the neighborhood. Policy L-48: Address privacy and quality of life for existing residents by considering scale and context in infill project design. Staff concurs with the applicant’s justification and finds that the modification is consistent with the policy and objectives of the Comprehensive Plan Land Use element and is the minimum adjustment necessary. ✓ b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: The applicant contends that the modification meets the intent of the code requirement by providing necessary number of vehicular and bicycle parking stalls within a smaller footprint designed within a uniquely shaped site. The use of smaller parking stalls, a slightly smaller drive aisle, and efficient wall racks for bikes will provide future RHA staff and building residents with adequate transportation infrastructure on site while ensuring the infrastructure can meet the anticipated parking demand and lower the potential for parking off-site. Staff concurs with the applicant’s justification and finds that the proposed modification would meet the objectives and function, appearance, environmental protection and maintainability intended by the Code requirements by providing the necessary parking and bicycle infrastructure in a smaller footprint without compromising the supply of spaces. ✓ c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The applicant contends that requested modification of the four standards identified as ‘a)’, ‘b)’, ‘c)’, and d)’ above would not be injurious to surrounding properties as the requests only involve on-site infrastructure that will have no impacts off site. By providing as much parking as possible by relaxing the dimension standards for parking lot stalls and aisles, the applicant will be able to ensure limited parking impacts to the neighborhood. Staff concurs with the justification and supports the applicant’s desire to limit parking impacts on nearby streets as much as possible. Therefore, staff finds the modification would not create adverse impacts to other properties in the vicinity. See comments under criteria ‘b’ and ‘c’. ✓ d. Conforms to the intent and purpose of the Code. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 47 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL Staff Comment: The applicant contends that the proposed modification conforms to the intent and purpose of the Code, which is to address the parking needs of a specific use based on the use’s unique characteristics and to limit impacts of parking on surrounding properties. Staff concurs the parking modification conforms to the intent and purpose of the Code by providing adequate parking based on parking demands anticipated by the use, limiting the potential for impacts to adjacent properties, and providing multiple bicycle rack types for future residents of the building. See also comments under criterion ‘b’. ✓ e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: See comments under criterion ‘b’. Staff concurs that the modification is justified as it is the minimum necessary according to the parking stall supply needed to accommodate parking during large events. In addition, the wall-mounted bicycle rack proposed would give future residents of the building multiple options for securing their bicycles while taking up a smaller footprint in the building and providing more space to other more active amenities. 24. Refuse and Recycling Standards Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9- 250D, the applicant is requesting a Modification from RMC 4-4-090 in order to allow the development to utilize only one refuse and recycling enclosure and to allow a reduced height for the refuse and recycling enclosure. Per RMC 4-4-090.D.1b, a minimum of one deposit/collection point is required for every thirty (30) dwelling units. Therefore the applicant would be required to provide two deposit/collection points instead of only one. The applicant’s justification for the modification is that the site grade and the minimum required parking make it difficult to provide access to multiple locations throughout the site. The applicant contends that providing one large trash collection location is a more efficient use of the limited space the site affords and allows an accessible route to a single enclosure within the required distance from the building entrance at the elevators. Per RMC 4-4-090.C.10, enclosures for outdoor refuse or recyclables deposit areas/collection points shall have gate openings at least twelve feet (12') wide for haulers. In addition, the gate opening for any separate building or other roofed structure used primarily as a refuse or recyclables deposit area/collection point shall have a vertical clearance of at least eleven feet (11'), but no more than fourteen feet (14'). The applicant contends that after discussing collection methods with Republic Services, the hauler, the dumpsters will be staged outside of the trash enclosure structure and collected on the side of the access driveway on collection days. Due to the dumpsters not being directly picked up within the trash enclosure, the applicant contends that the minimum overhead clearance is not necessary. Compliance Refuse and Recycling Standards Modification Analysis ✓ a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support flexible City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 48 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL street grid and pathway patterns, and are visually attractive, safe, and healthy environments. The applicant contends that the intent of providing only a single pick-up location was to provide enough parking onsite to minimize impacts to the surrounding residential neighborhood. They also contend that the approach is consistent with the land use and design policies in the City’s Comprehensive Plan, which encourage new development to be designed in a thoughtful way that considers how an infill development will impact existing residents in the neighborhood. By providing a single enclosure that helps to maximize the amount of on-site parking available and limit the potential for the smell or sight of trash to impact adjacent properties, the modification request supports Policy L-48 under the Comprehensive Plan Land Use Element. Policy L-48: Address privacy and quality of life for existing residents by considering scale and context in infill project design. Staff concurs with the applicant’s justification and finds that the modification is consistent with the policy and objectives of the Comprehensive Plan Land Use element and is the minimum adjustment necessary. Compliant if condition of approval is met b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: The applicant contends that the modification meets the intent of the code requirement by providing a large, well-designed, easily accessible trash and recyclables enclosures that is within the required distance from the building elevators. Staff concurs with the applicant’s justification and finds that the proposed modification would meet the objectives and function, appearance, environmental protection and maintainability intended by the Code requirements by providing a high-quality, easily accessible area to deposit trash and recyclables for future residents in the building. In addition, the lower height of the enclosure will minimize its visibility from surrounding properties and contribute to the overall high-quality site design. The location of the enclosure on the north side of the site will require residents to cross the single access drive that serves the parking lot in order to deposit their materials. Due to the potential for a vehicular/pedestrian conflict, especially during night hours, staff recommends as a condition of approval that the applicant be required to incorporate a concrete pathway connection across the access driveway that connects pathway on the west side of the parking lot with the concrete pad adjacent to the trash and recycling enclosure. The pathway shall be made of a contrasting material and color and shall be a minimum of five (5) feet wide. The pathway shall be shown on revised landscape plans submitted with the civil construction permit to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. The applicant shall also install pedestrian scale lighting on each side of the access driveway as well as at the enclosure entry in order to provide additional visibility for users. The applicant shall submit a lighting plan with the building permit application that includes the required pedestrian-scale lighting near the pathway crossing the driveway. The lighting plan shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. ✓ c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The applicant contends that providing a single enclosure with a lower overall height will help limit both visual and parking impacts to the surrounding neighborhood and would therefore not be injurious to adjacent properties. Staff City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 49 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL concurs with the justification and supports the applicant’s desire to minimize the visual impact of the enclosure and provide adequate on-site parking for residents, RHA staff members, and visitors. Therefore, staff finds the modification would not create adverse impacts to other properties in the vicinity. See comments under criteria ‘b’ and ‘c’. Compliant if Condition of approval under criterion ‘b’ is met d. Conforms to the intent and purpose of the Code. Staff Comment: The applicant contends that the proposed modification conforms to the intent and purpose of the Code, which is to minimize the impact of the trash and recycling enclosure while remaining convenient and safe to use for both residents and the hauler. Staff concurs that the modification conforms to the intent and purpose of the Code by providing an adequately sized enclosure that can be safely access by both residents and the hauler if the condition of approval is met. See also comments and condition under criterion ‘b’. ✓ e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: See comments under criterion ‘b’. Staff concurs that the modification is justified as it is the minimum necessary. 25. Fence, Hedges, and Retaining Walls Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4- 9-250D, the applicant is requesting a Modification from RMC 4-4-040.C.2.d, Retaining Wall Standards – Setback from Public Rights-of-Way and 4-4-040.C.2.f., Grading. Specifically, the applicant is proposing to install four-foot (4’) tall rockery walls along NE 10th St within the three-foot (3’) required setback area, to allow a reduced minimum horizontal distance of level grade abutting a proposed retaining wall near the surface parking area along Jefferson Ave NE, and to allow a retaining wall (new) and rockery wall (existing) to exceed eight-feet (8’) in height. The applicant’s justification for the request to allow a reduced setback at the base of the retaining wall along the NE 10th St ROW is due to the desire to raise the grade up as high as possible to hide the concrete wall of the adjoining ground floor parking while keeping the height low enough that a more expensive concrete wall would not be required. In order to raise the grade by the amount necessary, the applicant maintains the rockeries need to begin at the immediate back of the NE 10th St ROW. The applicant’s justification for the request to allow for a reduced horizontal distance of level grade abutting a retain wall is due to the space available between the retaining wall perpendicular to Jefferson Ave NE near the southeast corner of the surface parking lot and the emergency exit pathway to the south. According to the applicant, due to the height of the commercial ground floor, the second floor of the structure is located above the grade of the adjacent Jefferson Ave NE ROW, necessitating a slope down to the east from the building to the ROW. Therefore, the area adjacent to the retaining will slope perpendicular to the wall and will not allow for the required level grade equal to the height of the wall. The applicant’s justification for the request to allow for the construction of a new 9.5 -foot tall retaining wall between the surface parking area is that the significant grade change between the parking lot and southeast corner necessitates a wall taller than eight-feet (8’). The applicant’s justification for retaining the existing rockery wall abutting Jefferson Ave NE that extends up to a maximum of ten-feet (10’) tall is that reconstruction of the wall at a lower height would significantly impact the applicant’s ability to build the required roadway improvements along Jefferson Ave NE. o Staff concurs with the applicant’s justification for allowing a reduced setback at the base of a retaining wall, a reduced horizontal distance of level grade abutting a retaining wall, and two walls (one new, one existing) City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 50 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL to exceed eight (8’) feet in height, and therefore recommends approval of the modification requested as noted below: Compliance Fences, Hedges, and Retaining Walls Modification Criteria and Analysis ✓ a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support flexible street grid and pathway patterns, and are visually attractive, safe, and healthy environments. The requested retaining wall modifications are consistent with these policy guidelines. The applicant contends that the primary intent is to ensure that the structured parking area on the first floor of the building can be fully obscured from both the Jefferson Ave NE and NE 10th St ROW. In addition, the intent of allowing the existing rockery to exceed eight-feet (8’) is to allow for the city-required improvements on Jefferson Ave NE which will create a more walkable, pedestrian friendly environment. The modification request supports both Policy L-60 and Goal L-BB as under the Comprehensive Plan Land Use Element, as they related to ensuring high-quality development and limiting the visual impact of parking areas. Policy L-60: Improve the appearance of parking lots through landscaping and screening. Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new development is designed to be functional and attractive. Staff concurs with the applicant’s justification and finds that the modification is consistent with the policy and objectives of the Comprehensive Plan Land Use element and is the minimum adjustment necessary. Compliant if Condition of Approval is met b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: The applicant contends that the retaining wall heights needed in order to raise the grade near the structured parking area and to allow for the required improvements along Jefferson Ave NE to be installed necessitate a relaxation of the retaining wall standards. At staffs direction during the preliminary design phase, the applicant sought to fully obscure the exterior cement wall of the parking garage at the corner of NE 10th St and Jefferson Ave NE in order to provide a more functional and attractive building. In addition, by raising the grade at the southeast corner of the building, the applicant is afforded additional landscaping options that will serve to help break up the façade wall and improve the pedestrian experience. Although the proposed encroachment into the setback of the terrace walls and associated rockery wall abutting the sidewalk on NE 10th St is necessary to screen the structured parking exterior wall, the lack of space for landscaping at the base of the wall does not meet the objective of appearance or function. Therefore, staff recommends as a condition of approval that the applicant utilize a concrete seat wall in lieu of the proposed rockery wall adjacent to NE 10th St in order to provide additional pedestrian-scale features on along a primary façade. The details and specifications of the seat wall shall City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 51 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL be identified on the detailed landscape plan to be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. Staff concurs with the applicant’s justification and finds that the proposed modification would meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements if the condition of approval is met. ✓ c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The applicant contends that allowing for a reduced retaining wall setback for the proposed wall along NE 10th St, eliminating the horizontal distance of level grade requirement for the retaining wall perpendicular to Jefferson Ave N, and allowing two retaining/rockery walls to exceed 8-feet in height will help limit the visual impact of the structured parking garage to the surrounding neighborhood by allowing the grade to be raised high enough to fully screen the unsightly concrete exterior and reducing the overall height of any single retaining wall on the site. Therefore, the proposed modifications would not be injurious to adjacent properties. Staff concurs with the applicant and finds the modification would not create adverse impacts to other properties in the vicinity. See comments under criteria ‘b’ and ‘c’. ✓ See condition under criterion ‘b’ above d. Conforms to the intent and purpose of the Code. Staff Comment: The applicant contends that the proposed modifications to the retaining wall standards conforms to the intent and purpose of the retaining wall code, which includes creating aesthetically pleasing neighborhoods and encouraging the feeling of spaciousness along neighborhood streets. According to the applicant, allowing a reduced setback from the ROW will reduce the overall height of the terraced walls and therefore improve the pedestrian experience for sidewalk users. In addition, the applicant contends that eliminating the horizontal distance of level grade requirement for the retaining wall perpendicular to NE 10th would reduce the need for terracing and allow for more robust landscaping between the ROW and the building, thereby improving the pedestrian experience and the overall visual aesthetic of the primary building. Staff concurs with the applicant’s justification and finds that the modification conforms to the intent and purpose of the Code. See also comments and condition under criterion ‘b’. ✓ e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: See comments and condition under criterion ‘b’. Staff concurs that the modification is justified as it is the minimum necessary according to grading expectations provided by the applicant. 26. Street Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9-250D, the applicant is requesting a Modification from RMC 4-6-060.F.2, Minimum Design Standards for Public Streets and Alleys, to modify the ROW width for Jefferson Ave NE. The segment of Jefferson Avenue NE to the east of the site is classified as a residential access street with an existing ROW width of 50 feet. To meet the City’s complete street standards for a residential access street, half-street improvements are required along the entire site frontage including an 8-foot (8‘) planter strip, a five-foot (5’) sidewalk, a 0.5-foot curb, and two-feet (2’) at back of curb. The applicant has requested a modification to reduce the amount of dedication provided from 1.5 feet to 0 feet. The justification provided by the applicant is that the 1.5-feet of dedication would require the reconstruction of the existing City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 52 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL rockery retaining wall and would create challenges with installing the city-required roadway improvements. NE 10th St is classified as a collector street with an existing ROW width of 60 feet. To meet the City’s complete street standards for a collector street, half-street improvements are required along the entire site frontage including an 8-foot (8‘) planter strip, a eight-foot (8’) sidewalk, a 0.5-foot curb, and two-feet (2’) at back of curb. In addition, a total pavement width of 46 feet is required. The applicant has requested a modification to install the required half-street improvements but retain the existing pavement width City Staff from the transportation and planning divisions have reviewed the requested modification and will support the modification. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9-250D, if all conditions of approval are met. Therefore, staff is recommending approval of the requested modification as noted below: Compliance Street Modification Criteria and Analysis ✓ a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support grid and flexible grid street and pathway patterns, and are visually attractive, safe, and healthy environments. The requested street modification is consistent with these policy guidelines. In addition, maintaining the existing roadway width for both street, as proposed in the modification request, is consistent with various policies in the Comprehensive Plan including both L-I and L-48. The modification request is consistent with goal L-I by continuing to support a walkable neighborhood by installing new sidewalk improvements that allow pedestrians to traverse safely. In addition, the modification request is consistent with L-48 by allowing infill development without substantially changing the look and feel of the neighborhood, and without creating the temporary traffic and noise impacts associated with widening the two streets. Therefore, staff finds that the modification request is consistent with the policy and objectives of the Comprehensive Plan Land Use element and is the minimum adjustment necessary. Compliant if condition of approval is met b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: The applicant contends that the required dedication on Jefferson Ave NE of 1.5-feet would extend the ROW on top of the existing rockery retaining wall along Jefferson Ave NE at the southeast edge of the site, necessitating a costly re- establishment of the wall and potentially impacting the ability of the applicant to construct the required frontage improvements due to the grade. The applicant has proposed four (4) standards in order ensure the objectives of safety and function are met including providing a geotechnical engineer analysis certifying the stability of the existing rockery retaining wall after building demolition and frontage construction, providing a curb-bulb out on the intersection of NE 10th Street and Jefferson Avenue NE, providing a driveway entrance to the private driveway north of Jefferson Avenue NE and pursue to the maximum extent feasible, a connection to the existing private City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 53 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL sidewalk at the north property. In order to ensure the standards are met and the safety of the wall is demonstrated prior to project completion, staff recommends, as a condition of approval, the applicant shall demonstrate compliance with the four standards above prior to issuance of a Temporary or Final Certificate of Occupancy via a written report. The report shall be reviewed and approved by the Current Planning Project Manager. The City’s Transportation section reviewed the section of NE 10th St abutting the project recommended the applicant submit a modification to retain the pavement width, which was determined to be adequate. However, in order to ensure a safe pedestrian connection for residents crossing Jefferson Ave NE when walking north on NE 10th St towards Sunset Blvd NE, a curb bulb was recommended. Therefore, staff recommends, as condition of approval, the applicant shall install a curb bulb at the northeast corner of the intersection of NE 10th St and Jefferson Ave NE near the southwest corner of the site in order to improve pedestrian safety. The curb bulb shall be shown on the civil construction plans for review and approval by the Current Planning Project Manager. Therefore, staff finds the modification would meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment and if all conditions of approval are met. Compliant if condition of approval under ‘criterion b’ above is met c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The applicant contends that reducing the dedication requirement for the segment of Jefferson Ave NE east of the parcel and retaining the pavement width of NE 10th St in front of the site will allow for construction of the required improvements, which will improve walkability in the neighborhood, while allowing the limiting traffic impacts in the neighborhood. According to the applicant, retention of the rockery wall will reduce the amount of construction work necessary and therefore lower the overall impact to neighborhood while providing a sidewalk, landscape strip, and curb that will significantly improve the pedestrian experience. In addition, by pursuing a connection to the private sidewalk to the north, as required in the recommended condition of approval under ‘criterion b’ above, the applicant will provide an improved connection between the ROW and the residential property to the north. Therefore, staff finds the modification would not create adverse impacts to other properties in the vicinity if the condition of approval is met. See comments under criteria ‘b’ and ‘c’. Compliant if condition of approval under ‘criterion b’ above is met d. Conforms to the intent and purpose of the Code. Staff Comment: The applicant contends that even without the 1.5 feet of extra dedication, the proposed improvements would provide a safe condition for pedestrians along the property frontage and would continue to meet the objectives intended by code requirements. In addition, reducing the dedication to 0-feet allows for the retention of an existing retaining wall which if relocated, would create a significantly larger environmental neighborhood impact due to the constraints on the site. As indicated above, the City’s Transportation Section supports a modification to maintain the existing pavement width on NE 10th St as it provides adequate space for the required number of travel lanes and therefore meets the intent and purpose of the Code. Staff concurs the proposed modification meets the intent and purposes of the Code. See also comments and the condition under criterion ‘b’. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 54 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL ✓ e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: Staff concurs the modification is justified as it results in improved pedestrian streetscape while reducing impacts on the environment and surrounding neighborhood. See also comments and the condition under criterion ‘b’ and ‘d’. 27. Residential Mixed Use Standards Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9- 250D, the applicant is requesting a Modification from RMC 4-4-090 in order to allow the development to not meet three out of five criteria required as part of the Residential Mixed Use Standards in RMC 4-4-150. Specifically, the applicant is seeking to construct a residential mixed use building without conforming to the following standards: For vertically mixed use buildings, the facade necessary for interior entrances, lobbies, and areas/facilities developed for the exclusive use of the building’s residents, or their guests, is limited to twenty five percent (25%) of the overall facade along any street frontage or the primary facade. The applicant meets the requirement on the west facade but is proposing approximately 45% of the east façade abutting the Jefferson Ave NE ROW and approximately 50% of the west façade abutting the NE 10th St ROW to be developed for the exclusive use of the residents. Ground Floor Commercial Space Standards: At a minimum, the development shall include ground floor commercial space along any street frontage or, in the absence of street frontage, along the primary facade of the building in conformance with the following standards: b. A minimum floor-to-ceiling height of eighteen feet (18'), and a minimum clear height of fifteen feet (15') unless a lesser clear height is approved by the Administrator d. A central plumbing drain line e. A grease trap and a ventilation shaft for a commercial kitchen hood/exhaust. The applicant’s justification for the request is that due the nature of the tenant and the unlikelihood that a typical commercial retail or restaurant use would replace the RHA offices in the future, the standards in the Residential Mixed-Use standards, which are primarily geared towards promoting retail or restaurant commercial uses, are not applicable to the subject project. Staff concurs with the applicants justification for not providing the required components therefore recommends approval of the modification requested as noted below: Compliance Residential Mixed Use Standards Modification Analysis ✓ a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support flexible street grid and pathway patterns, and are visually attractive, safe, and healthy environments. The applicant contends that locating the RHA offices in the neighborhood will provide additional resources to neighborhood residents in addition to providing a high-quality building and site that improves the walkability in the surrounding area, even without incorporating a typical commercial use that necessitates compliance with the standards above. Staff concurs with the applicant’s justification and finds that the City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 55 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL modification is consistent with the policy and objectives of the Comprehensive Plan Land Use element and is the minimum adjustment necessary. ✓ b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: The applicant contends that the modification meets the intent of the code requirement by providing a well-designed, high quality development that will provide both additional housing and housing assistance services to the surrounding neighborhood. Staff concurs with the applicant’s justification and finds that the proposed modification would meet the objectives and function, appearance, environmental protection and maintainability intended by the Code requirements by providing services that are beneficial to the neighborhood even without the inclusion of a traditional commercial retail or restaurant component. ✓ c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The applicant contends by not providing unnecessary building features such as a grease trap, central plumbing, and tall ceilings, the cost savings could be used to improve the overall site design and building quality. In addition, the lack of such features would not have impact on surrounding properties. Staff concurs with the justification finds the modification would not create adverse impacts to other properties in the vicinity. See comments under criteria ‘b’ and ‘c’. ✓ d. Conforms to the intent and purpose of the Code. Staff Comment: The applicant contends that the proposed modification conforms to the intent and purpose of the Code, which is to provide an active ground-level use on primary streets while protecting the privacy of residents living in the building. Even though resident-exclusive spaces make up more than 25% of two facades, the primary entry of the building is located on an active street corner and is developed exclusively for the on-site service. Due to the topography on the site and desire to hide the concrete exterior wall of the parking structure, a number of the residential units are located at ground level are technically accessed via the second floor. Therefore, the applicant reserved the first floor faced for the on-site service where possible and thereby meets the intent and purpose of the code. Staff concurs that the modification conforms to the intent and purpose of the Code by providing only the necessary residential mixed use standards and by incorporating the on-site service along the first floor façade where possible. See also comments and condition under criterion ‘b’. ✓ e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: See comments under criterion ‘b’ and ‘d’. Staff concurs that the modification is justified as it is the minimum necessary. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 56 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL I. CONCLUSIONS: 1. The subject site is located in the Commercial & Mixed Use (CMU) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 17. 2. The subject site is located in the Center Village (CV) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval, see FOF 18. 3. The proposed site plan complies with Design District ‘D’ overlay standards and guidelines provided the applicant complies with City Code and conditions of approval, see FOF 19. 4. The proposed site plan complies with the Site Plan Review approval criteria provided the applicant complies with City Code and conditions of approval, see FOF 20. 5. There are safe walking routes to the school bus stop, see FOF 20. 6. There are adequate public services and facilities to accommodate the proposed site plan, see FOF 20. 7. The proposed site plan complies with the Critical Areas Regulations provided the applicant complies with City Code and conditions of approval, see FOF 21. 8. The variance request submitted with the application complies with the four (4) variance criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 22. 9. The parking modification request submitted with the application complies with the five (5) modification criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 23. 10. The refuse and recycling standards modification request submitted with the application complies with the five (5) modification criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 24. 11. The fence, hedges, and retaining walls standards modification request submitted with the application complies with the five (5) modification criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 25. 12. The street modification request submitted with the application complies with the five (5) modification criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 26. 13. The residential mixed use standards modification request submitted with the application complies with the five (5) modification criteria as established by City Code, providing the applicant complies with all advisory notes and conditions of approval contained herein, see FOF 27. 14. Key features, which are integral to this project include the memorial garden area on the north side of the site, the second-floor outdoor terrace area, and the pedestrian scale elements including the overhead canopies, full height modulating elements, first floor brick veneer on the façade, tall corner parapet near primary entry with use of alternative colors, and a significant amount of above grade landscaping elements such as planters and terracing near the primary entries. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 57 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL J. RECOMMENDATION: Staff recommends approval of the Sunset Gardens Hearing Examiner Site Plan Review, Variance, and Modifications, File No. LUA21-000168, SA-H, VAR, MOD, as depicted in the Site Plan (Exhibit 2), subject to the following conditions: 1. The applicant shall submit a detailed landscaping plan with the civil construction permit that provides those items noted in RMC 4-8-120D.12 and a detailed irrigation plan. The plan shall also clearly identify the 10-foot wide onsite street frontage landscaping along Jefferson Ave NE that is displaced by the stormwater facilities as currently shown. The stormwater facilities may be integrated into the street frontage landscaping however the required frontage planting shall take priority and if the street frontage landscaping and stormwater facilities are unable to comingle, the facilities shall be relocated outside of the required street frontage landscaping area. The detailed landscaping plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 2. The applicant shall submit a detailed landscape plan with the civil construction permit application that identifies the replacement trees meeting the replacement requirements of RMC 4-4-130. The landscape plan shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit approval. 3. The applicant shall clearly indicate on the detailed landscape plan submitted with the civil construction permit application how the plan meets the 10% tree replacement requirements including but not limited to the 50% credit limitation provided for those trees that are required pursuant to RMC 4-4-070. If onsite replacement for the trees is not practical, then payment into the City’s Urban Forestry Program fund may be approved for those trees that cannot be accommodated onsite. The detailed landscape plan shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit approval. 4. The applicant shall provide a joint use parking agreement for the residential and on-site service uses on the site. The joint use agreement shall be provided to the Current Planning Project for review and approval prior to the issuance of a Temporary or Final Certificate of Occupancy. 5. The applicant shall reserve a minimum of nineteen (19) structured or tuck-under stalls for the exclusive use of the residential units in the building. The applicant shall mark the designated stalls with paint, signage, or an alternative method approved by the Current Planning Project Manager. The method proposed shall be submitted to and approved by the Current Planning Project Manager prior to building permit approval. 6. The applicant shall submit a surface mounted utility plan that includes cross-section details with the civil construction permit application. The applicant shall work with franchise utilities to ensure, as practical, utility boxes are located out of public ROW view, active common open spaces, and they shall not displace required landscaping areas. The plan shall provide and identify screening measures consistent with the overall design of the development. The surface mounted utility plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 7. The applicant shall submit a rooftop equipment exhibit with the elevation plans associated with the building permit application. The exhibit shall provide cross section details and identify proposed rooftop screening that is integral and complementary to architecture of the buildings. The exhibit shall be reviewed and approved by the Current Planning Project Manager. 8. The applicant shall submit a detailed landscape plan that incorporates additional trees and/or shrubs between the sidewalk and ground floor residential units along NE 10th St. The detailed landscape plan shall be submitted to and approved by the Current Planning Project Manager to civil construction permit approval. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 58 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL 9. The applicant shall submit revised exterior elevations with the building permit application that provide additional primary entry elements that are prominent and visible from the street. Entry elements may include but are not limited to, additional architectural articulation, an alternate facade that provide differentiation in material and/or color from other portions of the building, pedestrian level lighting, or other identifying visual features as approved by the Current Planning Project Manager. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 10. The applicant shall submit a detailed landscape plan that identifies the pedestrian-scale landscaping requirements of RMC 4-3-100.E.2, including the species and spacing of individual plants, for the perimeter parking lot landscaping area near the southeast corner of the site. The landscape plan shall be submitted to and approved by the Current Planning Project Manager prior to civil construction permit approval. 11. The applicant shall incorporate additional raised planters or other architectural elements approved by the Current Planning Project Manager near the two primary front entrances off of NE 10 th St in lieu of the proposed at-grade landscape strips shown on the conceptual landscape plan (Exhibit 9). Such elements shall be shown on the detailed landscape plan submitted with the civil construction permit to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 12. The applicant shall submit details and manufacturers specifications for all common open space programming elements Landscape Plan (Exhibit 9). The details and specifications shall be identified on the detailed landscape plan to be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 13. The applicant shall submit details or manufacturers specifications for the proposed seat benches and other furniture shown on the Landscape Plan (Exhibit 9). The site furniture and other sitting amenities shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 14. The applicant shall submit revised elevation plans with the building permit application that shows a minimum of one (1) additional prominent corner feature such as a parapet extension, wrapped glazing, unique weather protection, and/or alternative elements approved by the Current Planning Project Manager. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 15. The applicant shall submit a revised east elevation which includes a minimum of 50% glazing along the ground floor between 4 feet and 8 feet above ground on the wall of the structured parking garage, or, indicate on a revised elevation how the elevation meets the intent of the standard’s guidelines. Alternatively, the applicant may propose additional landscaping in front of the façade that would provide visual interest and mitigate the visual impact of the blank wall. The revised east elevation and/or landscape plan shall be submitted to and approved by the Current Planning Project Manager prior to building permit approval. The applicant shall provide one (1) additional roof element that breaks up the massiveness of uninterrupted roof line and provides additional visual interest. The revised building elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 16. The applicant shall provide one additional roof element that breaks up the massiveness of uninterrupted roof line and provide additional visual interest. The revised building elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 17. The applicant shall utilize an alternative color scheme for the brick veneer. The applicant shall submit revised elevation plans with the building permit application that shows an alternative brick color with higher contrast. The revised elevations shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. City of Renton Department of Community & Economic Development Sunset Gardens Staff Report to the Hearing Examiner LUA21-000168, SA-H, VAR, MOD Report of August 17, 2021 Page 59 of 59 SR_HEX_SunsetGardens_210817_v5_FINAL 18. The applicant shall submit a materials board with the building permit application that provides samples of exterior cladding materials that are proposed on the building. The materials board shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 19. The applicant shall submit a lighting plan with the building permit application that adequately provides for public safety and creates visual interest to the building and site. Pedestrian scaled lighting shall be provided at the primary entrance and accent lighting on building facades. The parking area shall also contain adequate lighting to ensure safety and security. The lighting plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 20. The applicant shall coordinate with King County Metro prior to submitting construction permits to identify any needed accommodations for the abutting transit stop on NE 10th St that need to occur during construction of the site. Evidence of the coordination with King County Metro and the accommodation(s) shall be shown on the civil construction permit plans to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 21. The material used for the proposed plaza areas shall be scored and the connections in the parking lot shall be constructed of concrete or comparable alternative material. The scoring and material composition of the interior pedestrian pathways and plaza areas shall be reviewed and approved by the Current Planning Project Manager prior to civil construction permit approval. 22. The applicant shall comply with the recommendations of the geotechnical report prepared by Otto Rosenau & Associates, dated April 16, 2021 or future addenda. 23. The applicant shall incorporate a concrete pathway connection across the access driveway that connects pathway on the west side of the parking lot with the concrete pad adjacent to the trash and recycling enclosure. The pathway shall be made of a contrasting material and color and shall be a minimum of five (5) feet wide. The pathway shall be shown on revised landscape plans submitted with the civil construction permit to be reviewed and approved by the Current Planning Project Manager prior to permit issuance. The applicant shall also install pedestrian scale lighting on each side of the access driveway and at the refuse and recycling enclosure in order to provide additional visibility for users. The applicant shall submit a lighting plan with the building permit application that includes the required pedestrian-scale lighting near the pathway crossing the driveway. The lighting plan shall be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 24. The applicant shall utilize a concrete seat wall in lieu of the proposed rockery wall adjacent to NE 10th St in order to provide an additional pedestrian-scale feature on along a primary façade. The details and specifications of the seat wall shall be identified on the detailed landscape plan to be reviewed and approved by the Current Planning Project Manager prior to building permit issuance. 25. The applicant shall demonstrate compliance with the four standards under FOF 26, Criterion B, related to the stability of the existing retaining wall and access to the adjacent parcel, via a written report prior to issuance of a Temporary or Final Certificate of Occupancy. The report shall be reviewed and approved by the Current Planning Project Manager. 26. The applicant shall install a curb bulb at the northeast corner of the intersection of NE 10th St and Jefferson Ave NE near the southwest corner of the site in order to improve pedestrian safety. The curb bulb shall indicated on the roadway plans to be submitted and reviewed at the time of civil construction permit application. CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT STAFF REPORT TO THE HEARING EXAMINER EXHIBITS Project Name: Sunset Gardens Land Use File Number: LUA21-000168, SA-H, VAR, MOD Date of Hearing August 17, 2021 Staff Contact Alex Morganroth Senior Planner Project Contact/Applicant David Albers, SMR Architects / 117 S Main St, Suite 400, Seattle, WA 98104 Project Location 2900 NE 10th St, Renton, WA 98056 The following exhibits are included with the Staff Report to the Hearing Examiner: Exhibits 1-17: As shown in the Environmental Review Committee (ERC) Concurrence Memo Exhibit 18: Staff Report to the Hearing Examiner Exhibit 19: Proof of Neighborhood Meeting Exhibit 20: Planned Action Ordinance 5813 Exhibit 21: Sunset Area Final Environmental Impact Statement Exhibit 22: Garbage and Recycling Screening Detail