Loading...
HomeMy WebLinkAboutMFP21003717.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21003717 IVR Number: 21003717 Permit Information Permit Name: ExteNet Systems - Fiber - SOUTH RENTON - PHASE 2 - S-007407 SEG 21 Address/Location:08/04/2021Application Date:3340400006Parcel Number: 2233 EAST VALLEY RD Permit Type:08/13/2021Issue Date:Franchise Permit Work Class:08/15/2022Expiration Date:Major Utility Job Number: S-007407 SEG 21Franchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 EXTENET SOUTH RENTON PHASE 2 S 007407 SEG 21 PROPOSED OPEN TRENCH AND DIRECTIONAL DRILL SOUTH ALONG EAST SIDE OF E VALLEY RD FROM EXISTING CENTURYLINK VAULT TO EXISTING RISER LOCATION. PULL (1) 144F CABLE THROUGH. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 Applicant Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 PUBLIC STORAGE PO BOX 25025 GLENDALE , CA 91201 Owner Rachel Fenton Extenet Systems LLC 3030 Warrenville Rd Lisle, IL 60532 Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 12Know what'sbelow.before you dig.CallRRENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMTRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (ALL LANES)SIGN LEGEND ____ROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLSHORT-TERM STATIONARY WORK ZONE - MULTI-LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ROADWAY)CENTERLANECLOSEDAHEADEAST VALLEY RD2233 EASTVALLEY RDPARCEL NO.3340400005PARCEL NO.3340400006SW 19TH ST W20-1W20-5RW4-2RXXXW20-1W20-5CW4-2LXXXWORKVEHICLEL50'-100'W4-119LL/2L/2W4-119RW4-119R50'-100'WORK AREA424 SQ FTSCOPE OF WORK:USE WORK AREA TO INSTALL NEW VAULT, BORE & TRENCHCONDUIT, ACCESS EXISTING VAULT, AND PULL FIBER CABLETHROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYSPOTTER FLAGGERS ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONEW20-1PARCEL NO.3340400585GRADE NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 22Know what'sbelow.before you dig.CallRRENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMSCOPE OF WORK:USE WORK AREA TO INSTALL NEW VAULTS, BORE & TRENCHCONDUIT, AND PULL FIBER CABLE THROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYSIGN LEGEND ____ROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLSHORT-TERM STATIONARY WORK ZONE - MULTI-LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ROADWAY)CENTERLANECLOSEDAHEADTRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (ALL LANES)W20-1W20-5RW4-2RXXXWORKVEHICLEW4-119L50'-100'EAST VALLEY RDSW 23RD ST W20-1W20-5CW4-2LXXXGRADEL/2L/2W4-119RW4-119RPARCEL NO.3340400006PARCEL NO.21931001002300 EASTVALLEY RDPARCEL NO.3023059132PARCEL NO.1923059016WORK AREA336 SQ FTSPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONEGRADE L50'-100'ONLYR3-502W20-1X NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: R© 2021 Microsoft Corporation © 2021 TomTom SITE LOCATIONSCOPE OF WORK:Know what'sbelow.before you dig.CallRSHEET 5CONFIDENTIAL/PROPRIETARYSHEET: OF 17ENDADDRESS: 2233 EAST VALLEY RD, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANSSHEET INDEX1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-5. DESIGN VIEWS A-B6. UNDERGROUND TYPICALS7. SITE PHOTOGRAPHSCONTACTSNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMSHEET 4STARTPROPOSED OPEN TRENCH AND DIRECTIONALDRILL SOUTH ALONG EAST SIDE OF E VALLEYRD FROM EXISTING CENTURYLINK VAULT TOEXISTING RISER LOCATION. PULL (1) 144FCABLE THROUGH. NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 27#F#F#F##LEGEND NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 37The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16. NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: R3+004+005+006+00CONSTRUCTION NOTESPOTHOLE UTILITY CROSSING PRIOR TO BORE. MAINTAINMINIMUM 2' VERTICAL CLEARANCE AT THE CROSSING FROMEXISTING UTILITIES.4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF TUKWILA STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF TUKWILA STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF TUKWILASTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF TUKWILA STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.CONFIDENTIAL/PROPRIETARYSHEET: OF 47Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #7 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 5DESIGN VIEW A EAST VALLEY RD2233 EASTVALLEY RDPARCEL NO.3340400005PARCEL NO.3340400006PARCEL NO.1923059016SW 19TH ST 93' 18'18' 24'36'33' 11' 13' 11'121341RESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.DRESTORE ASPHALT PER CITY OF RENTONSTANDARDS.ERESTORE CURB & GUTTER PERCITY OF RENTON STANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.12'22'272'5' 12' 3' 27'A34'14'2'EGDADA NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: R0+00-1+00 -1+000+001+002+00CONFIDENTIAL/PROPRIETARYSHEET: OF 57Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #7 FOR SITE PHOTOGRAPHS.MATCH TO SHEET4DESIGN VIEW B CONSTRUCTION NOTESPOTHOLE UTILITY CROSSING PRIOR TO BORE. MAINTAINMINIMUM 2' VERTICAL CLEARANCE AT THE CROSSING FROMEXISTING UTILITIES.4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF TUKWILA STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF TUKWILA STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF TUKWILASTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF TUKWILA STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.EAST VALLEY RDSW 23RD STPARCEL NO.3340400006PARCEL NO.21931001002300 EASTVALLEY RDPARCEL NO.3023059132PARCEL NO.192305901671' 19'35'17' 18'18' 11'13'11'4119'2RESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.DRESTORE ASPHALT PER CITY OF RENTONSTANDARDS.ERESTORE CURB & GUTTER PERCITY OF RENTON STANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.DEGDA27'10'3'45'20'6'32A3' NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: RUNDERGROUND TYPICALSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 67TYPICAL TRENCH IN SOIL DETAILSCALE: NTSEXISTING GROUNDWARNING TAPEBACKFILL(8" LAYERS)6" MIN.12"36" MIN. DEPTH4"BACKFILL(COMPACTED @ 90%)HDPE DUCTCLEAN BACKFILLBACKFILL(COMPACTED EARTH @ 90%)24"12"6"6"3' MIN.PANEL WIDTH PER PLAN12"MIN.12"MIN.3" HMA (CL 12") (MATCHEX. IF GREATER)EX. ASPHALT SURFACE11" HMA (CL 12" OR 1)6" MIN. COMPACT MINERALAGGREGATE TYPE 2COMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGTYPICAL ASPHALT TRENCH DETAILSCALE: NTSTYPICAL CONCRETE TRENCH DETAILSCALE: NTS24"12"6"6"EX. CONCRETEREPLACE EX. CURBPER STD PLAN 410C6" MIN. TYPE 2 CRUSHEDROCKCOMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGPANEL WIDTH PER PLAN12"MIN.12"MIN.ZONE OF INFLUENCE12" PCC CLASS 6.5 (CL 1-1/2")233LA VAULT DETAILSCALE: NTSVAULTNo. 233-BLMANHOLE COVERAND FRAMELOADING: BUILT TOAN H2O RATING UPTO 150 KIP NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 21NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 2233 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 21 - PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 77CONSTRUCTION NOTESPHOTO #1: FACING SOUTH ON WEST SIDE OF EAST VALLEY RDPHOTO #2: FACING SOUTH ON WEST SIDE OF EAST VALLEY RD4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF TUKWILA STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF TUKWILA STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF TUKWILASTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF TUKWILA STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.143124132