HomeMy WebLinkAboutMFP21003815.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP21003815
IVR Number: 21003815
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:08/05/2021Application Date:1253800120Parcel Number: 2700 LIND AVE SW
Permit Type:08/24/2021Issue Date:Franchise
Permit Work Class:08/24/2022Expiration Date:Major Utility
Job Number: 726997Franchise Type:Cable
Description: Comcast TIE INTO EXISTING SPLICE CASE SP.WAKV.0430 WITH 48CT FIBER OPEN TRENCH ON SOFT
SURFACE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2" CONDUIT BORE. INSTALL (2) 2"
CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2" CONDUIT. PLACE NEW 17x30 VAULT. PLACE NEW SPLICE
CASE IN VAULT.
POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Applicant
Shannon Heaton
Cannon Construction
406, Porter Way
Milton, WA 98354
Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Michael Cannon
Cannon Construction Inc
406 Porter Way
Milton, WA 98354-9638
B: (253) 922-2787
C: (253) 588-4034
Contractor
Business License Number: 20838Electrical Contractor: CANNOCI873CL
Construction Contractor: CANNOCI055CS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Comcast Cable Communications Management
JB0000726997
Rhonda Resnik
253-864-4246
Rhonda_Resnik@comcast.com
2700 Lind Ave SW, Renton, WA 98057 Hardwoods Specialty
TIE INTO EXISTING SPLICE CASE SP.WAKV.0430 WITH 48CT FIBER
OPEN TRENCH ON SOFT SURFACE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2" CONDUIT
BORE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2" CONDUIT. PLACE NEW 17x30 VAULT. PLACE NEW SPLICE CASE IN VAULT
741 ft.
Cannon Construction LLC - Shannon Heaton 253-922-2787 ext 258
601590363 20838
8/5/2021
MFP21003815
Scott Warlick POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
8/24/2021
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.☐ A copy of the Traffic Control Plan (TCP) Application form.
2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
☐Include map(s) showing the location of the project and work area.
☐Be legible lettering and clear, contrasting, symbols of viewing or printing.
☐Must indicate street names, and north arrow and scale.
☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
☐Types of plans required:
☐Work hour plan – show all mobility impacts during construction hours.
☐Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
☐Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
☐Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
Hardwoods Specialty
2700 Lind Ave SW, Renton, WA 98057
Monday Friday 8:00am 3:00pm
TIE INTO EXISTING SPLICE
OPEN TRENCH. BORE. INSTALL CONDUITS & PULL FIBER THROUGH.
PLACE NEW 17x30 VAULT. PLACE NEW SPLICE CASE IN VAULT
Cannon Construction LLC 253 922 2787
Shannon Heaton sheaton@cannonconstructioninc.com
406 Milton Way Milton, WA 98354
MFP21003815
Scott Warlick CED 8/24/2021
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 11/25/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
•TCP must be approved prior to commencing the work, and all permit conditions shall be met.
•Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
•Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
•TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
•Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
•Approved Temporary TCP must be at the work site during work hours.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
Shannon Heaton 8/5/2021
ROWROWROWROWROWROWDRIVEWAYLANDSCAPINGROWROWROWROWROWROWROWROWROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW3000LIND AVE SWEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPDRIVEWAYLANDSCAPINGSIDEWALKWTW20-1
W4-2R
W20-5RDRIVEWAYW20-1
R2-1LANDSCAPING
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
TCP 1 3
7/26/2021 WK AG
COMCAST
SITE SPECIFIC TRAFFIC CONTROL PLAN THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
[UNDERGROUND WORK]
CONTROL TYPE: SINGLE LANE CLOSURE FOUR-LANE ROAD
SITE NOTES:
1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES
2. PLACE TEMP "NO PARKING" SIGNS AT LEAST 72 HOURS
PRIOR TO WORK
3. SIDE WALKS TO REMAIN OPEN DURING ROAD WORK,
UNLESS NOTED OTHERWISE
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONNEL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST
***TRAFFIC CONTROL ADDITIONAL NOTES ***
- At aerial work, will be a moving traffic control setup
-Will coordinate with business that will be affected by construction.
-Will have Spotter on site to escort pedestrian through work zone.
- All work will stop while pedestrians are escorted through work zones.
N
MFP21003815
SIDEWALKLANDSCAPINGLANDSCAPINGLANDSCAPINGSIDEWALKLANDSCAPINGROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW
EOP EOP EOP EOP EOP
ROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROW2900
SW 29TH ST
EOP
EOP
EOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPLIND AVE SWLANDSCAPINGLANDSCAPINGW20-1
W4-2R
W20-5RWT W20-1
W20-1
R2-1
SIDEWALK
SIDEWALK
COMCAST
SITE SPECIFIC TRAFFIC CONTROL PLAN THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
[UNDERGROUND WORK]
CONTROL TYPE: SINGLE LANE CLOSURE FOUR-LANE ROAD
SITE NOTES:
1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES
2. PLACE TEMP "NO PARKING" SIGNS AT LEAST 72 HOURS
PRIOR TO WORK
3. SIDE WALKS TO REMAIN OPEN DURING ROAD WORK,
UNLESS NOTED OTHERWISE
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONNEL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST
***TRAFFIC CONTROL ADDITIONAL NOTES ***
- At aerial work, will be a moving traffic control setup
-Will coordinate with business that will be affected by construction.
-Will have Spotter on site to escort pedestrian through work zone.
- All work will stop while pedestrians are escorted through work zones.
N
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
TCP 2 3
7/26/2021 WK AG
MFP21003815
SIDEWALKLANDSCAPINGLANDSCAPINGROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWEOPEOPEOPEOPEOPEOPEOPROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
EOP EOP EOP EOP EOP EOP EOP
ROWROWROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROWROWROWROW
2700
SW 29TH STEOPEO
P
EOP
EOPEOPEOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPLIND AVE SWSIDEWALKLANDSCAPINGLANDSCAPINGDRIVEWAYLANDSCAPINGLANDSCAPINGW20-1
W20-1
W4-2R
W20-5RWT R2-1
COMCAST
SITE SPECIFIC TRAFFIC CONTROL PLAN THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTION
[UNDERGROUND WORK]
CONTROL TYPE: SINGLE LANE CLOSURE FOUR-LANE ROAD
SITE NOTES:
1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES
2. PLACE TEMP "NO PARKING" SIGNS AT LEAST 72 HOURS
PRIOR TO WORK
3. SIDE WALKS TO REMAIN OPEN DURING ROAD WORK,
UNLESS NOTED OTHERWISE
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES
WILL CONFORM TO SPECIFICATIONS STATED IN THE
FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL
DEVICES (M.U.T.C.D)
CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONNEL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST
***TRAFFIC CONTROL ADDITIONAL NOTES ***
- At aerial work, will be a moving traffic control setup
-Will coordinate with business that will be affected by construction.
-Will have Spotter on site to escort pedestrian through work zone.
- All work will stop while pedestrians are escorted through work zones.
N
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
TCP 3 3
7/26/2021 WK AG
MFP21003815
THIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON COMPANIES
CONTACTS:
PROJECT MAP:
1 - COVER SHEET
2 -GENERAL NOTES
3 -LEGEND
4 -DETAILS
5 -OVERVIEW
6-7 -DESIGN
- 48CT FIBER: 741 FT. + 20% STORAGE = 889 FT.
*ALL FOOTAGES AND MATERIALS ARE ESTIMATED
SCOPE OF WORK:
SHEET INDEX:
BILL OF MATERIALS*:
NEW AERIAL =
OVERLASH =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
RISER (0)=
TOTAL FOOTAGE =
0 FT.
0 FT.
741 FT.
0 FT.
0 FT.
741 FT.
PROJECT DESCRIPTION - ROW*
NEW BUILDING PATH WAY =
EXISTING BUILDING PATH WAY =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
TOTAL FOOTAGE =
0 FT.
0 FT.
0 FT.
0 FT.
0 FT.
PROJECT DESCRIPTION -SITE*
TOTAL PROJECT FOOTAGE =741 FT.
- TIE INTO EXISTING SPLICE CASE SP.WAKV.0430 WITH 48CT FIBER
- OPEN TRENCH ON SOFT SURFACE. INSTALL (2) 2" CONDUITS.
PULL (1) 48CT FIBER THROUGH (1) 2" CONDUIT
- BORE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER THROUGH
(1) 2" CONDUIT
- PLACE NEW 17x30 VAULT. PLACE NEW SPLICE CASE IN VAULT
- BORE. INSTALL (1) 2" CONDUITS. PULL (1) 48CT FIBER THROUGH
2700 LIND AVE SW
HARDWOODS SPECIALTY
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
COMCAST
COMCAST COMMUNICATION
Mike Fontenot - (425)-213-5482 - Mike_Fontenot@cable.comcast.com
WORK AREA
METRO-E
JB# 0000726997
RENTON, WA 98057
CANNON COMPANIES
Alex Gaunt - (206)-856-3583 - agaunt@cannonconstructioninc.com
MFP21003815
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
GENERAL NOTES 2 7
7/26/2021 WK AG
COMCAST
MFP21003815
EDGE OF PAVEMENT
FOGLINE
POWER
COMMUNICATION
SEWER
DRAIN
DRAINAGE DITCH
GAS
WATER
TRAFFIC SIGNAL
TELCOM
STEAM
UNKNOWN UTILITY
RIGHT OF WAY
TRAFFIC CONES
PROPOSED NEW BORE
STRAW WATTLES
P
LT
CW
R
UTILITY POLE
VAULT - SMALL
PEDESTAL
STREET LIGHT
CROSSWALK LIGHT
UTILITY RISER
V VAULT - SMALL
444LA MANHOLE
VAULT - 25TA
CATCH BASIN
CATCH BASIN WITH SOCK
GLULAM UTILITY POLECENTER LINE
LANE LINE
FENCE
HIGH VISIBILITY FENCE
S SEWER MANHOLE
D DRAIN MANHOLE
W WATER MANHOLE
V UTILITY VALVE
SHRUBBERY
BORE PIT
VAULT - LARGE
VAULT - 25TA
C COMMUNICATION MANHOLE
FIRE HYDRANT
DISTANCE STATIONSTA 0+00
CONSTRUCTION NOTE CALLOUT#
X.X DISTANCE DIMENSION
ASPHALT SURFACE
CONCRETE SIDEWALK PANEL
CONCRETE ROADWAY PANEL
HF H-FRAME
VAULT - LARGE
C
CCAB CABINET
LEGEND
LANE DIRECTION INDICATOR
PROPOSED MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES
A
7
LANDSCAPE
CROSS SECTION SYMBOL
CROSS SECTION NAME
CROSS SECTION SHOWN ON PAGE
FL FL
EOP
P P
TS TS
C C
D D
DD DD DD DD DD DD
G G
W W
T T
ST ST
ROW ROW
S
UK
CB
CB
P P
V V V
V VV
WORK BEING DONE1LOCATION PHOTO NOTE CALLOUT
#PHOTO LOCATOR SYMBOL
PROPOSED NEW TRENCH
PROPOSED NEW AERIAL STRAND
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
LEGEND 3 7
7/26/2021 WK AG
COMCAST
MFP21003815
STORM DRAIN INLET PROTECTION
STANDARD DETAIL2TRENCH - SOFT SURFACE
STANDARD DETAIL1
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
DETAILS 4 7
7/26/2021 WK AG
COMCAST
MFP21003815
3
2
1
CONSTRUCTION NOTES:
TIE INTO EXISTING SPLICE CASE SP.WAKV.0430 WITH
48CT FIBER
OPEN TRENCH ON SOFT SURFACE. INSTALL (2) 2"
CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2"
CONDUIT
BORE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER
THROUGH (1) 2" CONDUIT
PLACE NEW 17x30 VAULT. PLACE NEW SPLICE CASE IN
VAULT
BORE. INSTALL (1) 2" CONDUITS. PULL (1) 48CT FIBER
THROUGH
V
V455' BORE3' TRENCH1
2
3 270' BORE3
3' TRENCH2
4
5
V 10' BORE5
4
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
OVERVIEW 5 7
7/26/2021 WK AG
COMCAST
N
MFP21003815
DRIVEWAYSTA 20+00STA 20+50STA 21+00STA 21+50STA 22+00STA 22+50STA 23+00STA 23+50STA 24+00STA 24+50DRIVEWAY
SIDEWALK
LANDSCAPING
LANDSCAPING
LANDSCAPING
SIDEWALK
LANDSCAPINGROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS SS SS
SS
SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
D D
D D
D
D
D
D
D
D
D
DDDDDDDDDDD
D
D
DDDDDDD
D
D
D
D D D D D D D D D D D D D D D D D D D D D D
DDDD D D D D D D
W WWWWWWWW
W W W W W W W W W
W W
VVVMMFHWWWWWWWWWWWWWWWW
WWWWW
WWWWWEOP
EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPVVG G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
LIND AVE SW
C C C
P P P P P P P P P P P P P P P P P P P P P P P P P P P P P
LT
LT
V
PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP
SIDEWALK
LANDSCAPING
LANDSCAPING
DRIVEWAY
LANDSCAPING
SIDEWALK
LANDSCAPING LANDSCAPING LANDSCAPING
SCALE: 1"=30'
0'15'30'60'
STATION START
STATIONING STARTS AT 10+00 AT THE
INTERSECTION OF SW 34TH ST & LIND AVE SW
PROPOSED PATH DISCLAIMERS
1.PROPOSED PATH MAY CHANGE AT TIME OF
CONSTRUCTION DUE TO UTILITY LOCATIONS
AND INSPECTOR REQUIREMENTS
2.UNKNOWN UTILITY DEPTHS TO BE VERIFIED IN
FILED DURING TIME OF CONSTRUCTION
UTILITY DISCLAIMER
ALL LOCATIONS OF UTILITIES SHOWN ARE
APPROXIMATE. LOCATION OF ALL UTILITIES TO BE
VERIFIED PRIOR TO CONSTRUCTION. CALL UTILITY
UNDERGROUND LOCATION CENTER AT
1-800-424-5555 2
1
POTHOLE IS SOFT SURFACES
WHEN AVAILABLE. PATCH
POTHOLE LOCATION PER LOCAL
JURISDICTION SPECIFICATION
LOCATION POTHOLE DISCLAIMER
CSWPP LEGEND
NATIVE TRENCH MATERIAL SHALL BE COVER WITH
PROTECTIVE TARP AND SECURED WITH SANDBAGS
TO PREVENT RAIN WATER ABSORPTION.
CATCH BASIN WITH SOCKCB
CONSTRUCTION NOTES:
TIE INTO EXISTING SPLICE CASE SP.WAKV.0430 WITH
48CT FIBER
OPEN TRENCH ON SOFT SURFACE. INSTALL (2) 2"
CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2"
CONDUIT
BORE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER
THROUGH (1) 2" CONDUIT
DRAINAGE SYSTEM DISCLAIMER
EXISTING DRAINAGE SYSTEM (GRATE INLET, DITCH, ETC.)
SHALL BE PROTECTED AND FUNCTIONAL THROUGHOUT THE
CONSTRUCTION PROJECT. IF ANY PARTS OF THE SYSTEM ARE
IMPACTED BY CONSTRUCTION ACTIVITIES, THEY SHALL BE
RESTORED TO THE ORIGINAL CONDITIONS.
N
BUS STOP. WILL HAVE TO COORDINATE
WITH KING COUNTY METRO AT TIME OF
CONSTRUCTION
3
1 CBCB
BOREPIT
2R
1R 2
1R
RESTORATION NOTES:
RESTORE LANDSCAPING PER CITY OF RENTON
SPECIFICATIONS
RESTORE CONCRETE SIDEWALK PANEL PER CITY OF
RENTON SPECIFICATIONS2R
3
455' BORE6'
8'
2'3' TRENCHSTA 20+15SSSMATCH LINESEE SHEET 7OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
DESIGN 6 7
7/26/2021 WK AG
COMCAST
MFP21003815
LANDSCAPING
SIDEWALK
LANDSCAPING
STA 25+00STA 25+50STA 26+00STA 26+50STA 27+00STA 27+50STA 28+00STA 28+50STA 29+00STA 29+50SIDEWALK
LANDSCAPING
LANDSCAPING
SIDEWALK
LANDSCAPING
LANDSCAPING
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPROWROWEOPEOPROWROWROWROWSS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS
SSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS
SSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
D
DDDDDDDDDDD
D
D
D
D
D
DDDD
D
D
D
D
D D D D D D D D D D D D D D D D D D D D D
D D D D D D D
DDDWWWWWWWWWWWW
WWWVVVVVVVVVFHFHFHWWWWWWWWWWWW WWWWWWWWWWWWWWW
W
SW 29TH STEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPVG G G G G G G G G G G G G G G G G G G G G G G G G G G G G GLIND AVE SW
P P P P P P P P P P P P P P P P P P P P P P P P P P P P P PCBCB
LT
LT
LT
PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP
SIDEWALK
LANDSCAPING
LANDSCAPING
DRIVEWAY
LANDSCAPING LANDSCAPING
SCALE: 1"=30'
0'15'30'60'
N
STATION START
STATIONING STARTS AT 10+00 AT THE
INTERSECTION OF SW 34TH ST & LIND AVE SW
PROPOSED PATH DISCLAIMERS
1.PROPOSED PATH MAY CHANGE AT TIME OF
CONSTRUCTION DUE TO UTILITY LOCATIONS
AND INSPECTOR REQUIREMENTS
2.UNKNOWN UTILITY DEPTHS TO BE VERIFIED IN
FILED DURING TIME OF CONSTRUCTION
UTILITY DISCLAIMER
ALL LOCATIONS OF UTILITIES SHOWN ARE
APPROXIMATE. LOCATION OF ALL UTILITIES TO BE
VERIFIED PRIOR TO CONSTRUCTION. CALL UTILITY
UNDERGROUND LOCATION CENTER AT
1-800-424-5555
POTHOLE IS SOFT SURFACES
WHEN AVAILABLE. PATCH
POTHOLE LOCATION PER LOCAL
JURISDICTION SPECIFICATION
LOCATION POTHOLE DISCLAIMER
CSWPP LEGEND
NATIVE TRENCH MATERIAL SHALL BE COVER WITH
PROTECTIVE TARP AND SECURED WITH SANDBAGS
TO PREVENT RAIN WATER ABSORPTION.
CATCH BASIN WITH SOCKCB
DRAINAGE SYSTEM DISCLAIMER
EXISTING DRAINAGE SYSTEM (GRATE INLET, DITCH, ETC.)
SHALL BE PROTECTED AND FUNCTIONAL THROUGHOUT THE
CONSTRUCTION PROJECT. IF ANY PARTS OF THE SYSTEM ARE
IMPACTED BY CONSTRUCTION ACTIVITIES, THEY SHALL BE
RESTORED TO THE ORIGINAL CONDITIONS.
V
BOREPIT
BOREPIT
5'5'
5'
5'
2'
1
3' TRENCH SSSTA 24+76STA 24+791R
1RSEE SHEET 6MATCH LINE1
CONSTRUCTION NOTES:
OPEN TRENCH ON SOFT SURFACE. INSTALL (2) 2"
CONDUITS. PULL (1) 48CT FIBER THROUGH (1) 2"
CONDUIT
BORE. INSTALL (2) 2" CONDUITS. PULL (1) 48CT FIBER
THROUGH (1) 2" CONDUIT
PLACE NEW 17x30 VAULT. PLACE NEW SPLICE CASE IN
VAULT
BORE. INSTALL (1) 2" CONDUITS. PULL (1) 48CT FIBER
THROUGH
2
2
270' BORE V
BOREPIT
5'
10' BORE
3
4
4
1R
1R
RESTORATION NOTES:
RESTORE LANDSCAPING PER CITY OF RENTON
SPECIFICATIONS
3STA 27+545'
OF
DATE REVISION BY QC
CANNON COMPANIES
0000726997HARDWOODS SPECIALTY
2700 LIND AVE SW
RENTON, WA 98057
DESIGN 7 7
7/26/2021 WK AG
COMCAST
N
MFP21003815