HomeMy WebLinkAboutP_Site_Plan_and_Analysis_210804_v1x xx
OHP OHPOHP
GAS GASGAS
SD SDSD
W WW
SS SSSS
∆=30°19'18"R=410.51'L=217.25'∆=2 5 °27 '15"R=618.89'L =274.95'N24°32'09"W44.93'214.65'-MEAS 214.72'-R4(29,359 S.F.)SSSDSSSSSSICVSS332.7'331.2'334.7'334.8'335.5'338.2'333.5'334.1'335.7'337.4'332.8'333.2'337.5'336.0'334.9'334.1'333.4'331.6'334.6'335.0'335.0'335.1'335.2'333.6'335.2'336.3'336.5'336.1'335.6'335.0'336.1'335.5'336.3'337.3'336.7'339.4'338.3'338.8'340.0'338.9'339.1'338.1'339.1'339.4'337.0'339.6'339.4'340.7'338.5'338.0'338.0'337.8'337.7'337.4'337.1'337.0'337.4'337.9'337.8'337.7'337.7'338.2'337.1'336.1'339.2'339.3'339.3'339.4'337.2'337.4'341.7'339.5'340.8'340.2'341.1'341.6'337.3'337.1'337.0'340.1'339.8'33834033833 63363343323383 3 8
3363 3 8
3 4 0 3363323 3 4334
24' DRIVEWAYEASEMENTREC. NO.20050422900002PPW
1.THIS DRAWING IS INTENDED TO REFERENCE OR SHOW CERTAIN SITE FEATURES WHERE
APPLICABLE REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR INFORMATION NOT SHOWN HERE. SEE
SHEET A1.00 FOR SITE PLAN INFORMATION.
2.THIS DRAWING IS INTEDED TO SHOW BUILDING SHELL ONLY. SEE ENLARGED UNIT AND COMMON
AREA PLANS FOR ADDITIONAL INFORMATION.
3.GRID PATTERNS WHERE SHOWN INDICATE LOCATION OF SCORE LINES, EXPANSION JOINTS, OR
CONTRACTION JOINTS IN TOPPING SLABS AND SLABS ON GRADE. ALIGN THESE JOINTS WITH OPEN JOINTS
IN UNIT PAVERS ON PEDESTALS WHERE THE TWO MEET. SEE LANDSCAPE DRAWINGS FOR ADDITIONAL
INFORMATION.
4.PROVIDE FIRE DEPARTMENT CONNECTIONS (FDC) AS REQUIRED BY LOCAL FIRE DEPARTMENT.
FDC'S SHALL BE READILY VISIBLE AND ACCESSIBLE ON A STREET FRONTAGE OR WHERE OTHERWISE
APPROVED AND LOCATED AT LEAST 10 FEET AWAY FROM BUILDING EXITS.
5.PROVIDE RECESSED WALL HYDRANTS AT PERIMETER OF BUILDING WHERE REQUIRED BY LOCAL
FIRE DEPARTMENT.
6.PROVIDE MINIMUM 1-FOOTCANDLE EMERGENCY ILLUMINATION AT INTERIOR LOBBIES AND
CORRIDORS, RESIDENTIAL AND ENTRY COURTYARDS TO PUBLIC WAY. ANY LIGHTING FIXTURES SHOWN
ARE TO ILLUSTRATE GENERAL LIGHTING INTENT ONLY. PROVIDING ADEQUATE ILLUMINATION LEVELS IS
THE RESPONSIBILITY OF THE ELECTRICAL DESIGN-BUILD CONTRACTOR.
7.EXIT SIGNS ARE MINIMUM REQUIRED. CONTRACTOR TO PROVIDE ADDITIONAL EXIT SIGNS AS
REQUIRED BY AHJ.
8.PROVIDE BOLLARDS AND/OR OTHER IMPACT PROTECTION MEASURES AT
MECHANICAL/ELECTRICAL EQUIPMENT WHERE EXPOSED TO MOVING TRAFFIC. SEE DETAIL 4/A8.01
9.REFERENCE BUILDING PLANS FOR ADDITIONAL DIMENSIONS FOR BUILDING LENGTH, MODULATION ,
ETC.
SITE PLAN GENERAL NOTES
SYMBOL LEGEND
DATA BOX
WOOD BOARD FENCE
OVERHEAD POWER LINE
PM POWER METER
GM GAS METER
WM WATER METER
PROPOSED WALL
CONCRETE HATCH
ASPHALT HATCH
GAS LINE
STORM DRAIN
WATER LINE
SANITARY SEWER LINE
PERMEABLE PAVERS
(E) 5-STORY
BUILDING
(E) SOLID WALL
BARRIER
(E)
ACCESS EASEMENTREC #20050422900002R O W L A N D S C A P E
1 0 ' - 0 "T C E
2 3 ' - 0 " A P P R O X
ROW LANDSCAPE10' - 0"FRONT BSBL15' - 0"(E) STREET
CURB
(E) SIDEWALK
TO REMAIN
(N) 8' PLANT STRIP
WHERE (E) SIDEWALK
WAS LOCATED PER CIP
DRAWINGS #20130276
F R O N T B S B L15' - 0 "ABANDON EXISTING PARKING EASEMENT
REC #9809221300
REC #20050422900002
(N) CURBCUT TO
GARAGE ENTRY
RELOCATION OF (N)
8' SIDEWALK PER CIP
DRAWING #20130276
LINE OF BACK OF
(E) SIDEWALK TO
BE RELOCATED
PER CIP #20130276
A P P R O X L O C / E X T E N T S O F T C E T E R M S O F R E D U C E D E X T E N T S T O B E N E G O T IA T E D W IT H C IT Y O F R E N T O N
CLEAR VISION
TRIANGLE
SOLID WASTE
STORAGE ACCESS
NEW TRANSFORMER
BY PSE
BACKING DIST.
24' - 0"
VEHICULAR LIFT BY
CITYLIFT
(14 STANDARD
VEHICLE CAPACITY)
BACKING DIST.
24' - 0"
ALL PARKING SHOWN
PROVIDED AS STRUCTURED
PARKING PER
RMC 4-4-080F.8.b ,TYP.
RETAIL A
ENTRY
RETAIL B
ENTRY
RETAIL B
ENTRY
RETAIL A
ENTRY
RESIDENTIAL
STAIR EXIT
RESIDENTIAL
PARKING ENTRY
RESIDENTIAL
MAIN ENTRY
334.43'
335.38'
333.65'338.75'
338.75'
335.75'
338.75'
338.75'
334.00'
334.00'
RESIDENTIAL
PARKING ENTRY
NE SUNSET BLVDH A R R I N G T O N A V E N E
RETAIL A
BACK ENTRY
RETAIL B
BACK ENTRY
P L : R =6 4 8 .8 9 ' L =1 9 9 .9 8 'P
L: 44.99'PL: R=4
60.
5
1'
L
=136
.40'
PL: 241.84'PL:
138.55'
(E) TREE TO BE DEMOD
172' - 1"26' - 4"1 7 ' - 3 "5' - 0 "18' - 1"92' - 3"13' - 11"30' - 0"5 0' - 0"(E) CURBCUT TO BE ABANDONED
(E) CURBCUT TO BE ABANDONED
A
B
A
NDONE
D
A
ND RE
L
OCA
T
E
D(
E
) CURB
CUT
T
O
B
E
CURBCUT TO REMAIN
(E) ACCESS EASEMENT
SB-1
SB-1
GN-1
GN-1
GN-1
ST-10
ST-11
FH-1
FH-2
BK-5
14' - 8"205' - 6"
3' - 2"
DE-13
DE-13
(N) LANDSCAPE
STRIP AND CURB
PER CIP #20130276
(N) HYDRANT
© 2021 GROUPARCHITECT, INC. ALL RIGHTS RESERVED
SHEET TITLE:
PROJECT No.
CHECKED:
DRAWN:
REVISIONS
CLIENT:
PROJECT:1735 westlake avenue north, suite 200, seattle, wa 98109206.365.1230 | www.grouparch.comORIGINAL SHEET SIZE IS 24"x36" | PLOT DATE:
SHEET DATE:
ISSUE:
HARRINGTON
REDEVELOPMENT
960 HARRINGTON AVE.
NE, RENTON, WA 98056
ZARNOOR
ASSOCIATES LLC
PROJECT ISSUES:
SITE PLAN REVIEW 08/04/2021
8/2/2021 10:33:27 AM
SITE PLAN
A1.00
1922
BJP
KJS
08/04/21
SITE PLAN REVIEW SUBMITTAL
BK-5 BICYCLE RACK - FLOOR MOUNTED 2 STALL
DE-13 DEMO EXISTING BUILDING
FH-1 EXISTING FIRE HYDRANT TO REMAIN
FH-2 NEW FIRE HYDRANT PER CIVIL DWGS
GN-1 LINE OF BUILDING ABOVE
SB-1 BUILDING SETBACK LINE
ST-10 PAVING PER LANDSCAPE PLANS
ST-11 PLANTINGS PER LANDSCAPE PLANS
KEYNOTES
SCALE:1" = 20'-0"
SITE PLAN
338.36'
336.93'
331.73'
335.18'
B (STORY 1)
R-2 (STORY 3)
R-2 (STORY 4)
R-2 (STORY 5)
R-2 (STORY 6)
AVG. GRADE
335' -6 1/2"
MAX HT.
405' -6 1/2"MAX. BUILDING HEIGHT70' - 0"T.O.PENTHOUSE78' - 7"R-2 (STORY 1)
WCF MAX HEIGHT
16' - 0"R-2 (STORY 2)
R-2 (STORY 7)19' - 0"Departure
Number
Land Use Code
and Description
Code Requirement Departure Requested Applicant Design Rationale
D3 4-4-150.D.2.a: Ground floor
commercial space standards
depth.
Minimum average depth of 30' and no less than 20' at any given point for
commerical space
Proposing more than min. depth of 20' along alll
commercial front. Average is approximately 28'
With limited area of our lot and the need to provide a minimum amount of parking stalls, we have reduced possible depth of all our grade level occupiable
spaces in order to allow Renton standard stall sizes and aisle dimensions. This requirement thus has reduced a long portion of the depth along the NE
sunset Blvd facade to about 22'. The possible make up for the average is at the bend onto Harrision, increasing our depth to about an average of 31'.
Total height of building shall be a maximum 70' measuring from building's
average grade plan to the average height of highest rooftop
Project proposes 77'-0" from highest
penthouse structure
The building proposed for main rooftop structure is below the max 70' structure height at about 68'-1". Additional height space is required for
mechanical equipment and screening components. Elevator shafts require additional height for structure and machinery above the ceiling of the 7th
floor. Also, to vary up the roof lines, we are needing the extra height to play with top of surfaces and parapets per urban design 4-3-100.E3
D1 4-2-120.A: Building height
The max percent of compact parking stalls in the overall scheme is 30%The proposed amount of compact
stalls compared to the total is 38%
Within our limited area of space to provide for parking, we chose to fit more compact stalls to allow the amount to reach closer to required total stalls. If to
keep within max % of compact stalls, our total stall count would be reduced to half the current count, or a large portion of retail/residential space would have
to be take out. Our preference is to promote a better commercial space for pedestrians over type of parking.
D4 4-4-080.F.8: Parking stall
percentage required
The max percent of residential wall along street frontage is 25% of
overall facade along any street frontage
The proposed length of residential facade is
about 31.9% of the overall facade frontage
Our residential L1 spaces and commercial areas are broken up by rated vertical circulation stairways. These building componebts are main points of
egress from the upper tower of the building and must be separated by a minimum distance to give reasonable exit access during an emergency, IBC
1015.2.1. By pushing our north stair south, it would reduce the residential facade, but break the IBC seperation requirements.
D2 4-4-150.B.2: Limit of overall street
frontage of residential space at ground
level
Parking spaces for residential units shall be 1 space per DU. For
commercial stalls the stall count shall be min 10 stalls / 1000 sf dining
area space
Proposed total stalls is 70 spaces while the
requirement of total stall is 75 spaces
In order to keep to Renton standards of stall size and aisle width along with the grade level occupiable spaces, the minimum parking stall count is
unobtainable. To try to make up for the amount of stalls, we are proposing to install a parking lift system for the residential count in order to get closer to
the parking minimum.
D5 4-4-80.F.10.d: Number of parking
spaces required
D6 4-4-.080-F-8-b: Standard parking
stall size -Structure Parking
Structured parking is part of a structure above or below grade with stalls
accessed via interior aisles and used for temporary storage of motor
vehicles. excludes surface parking.
Proposed standard parking under on L1 partially
under building to be sized as structural parking
To provide more parking for both commercial and residential occupancies, we are proposing the capability to have structured parking stall sizes within an
area that is below the main building but techinically in a paved outdoor area.
18667.38 SF
BUILDING COVERAGE
LOT COVERAGE
10691.02 SF
NON-BUILDING COVERAGE
LOT COVERAGE
COMMERCI
AL65'
-
11"
C
O
M
M
E
R
CIA
L
31' - 1"
C O M M E R C I A L39' - 9 "M I X E D U S E9' - 3 "
1564.96 SF
RETAIL A
GROSS AREA
2132.43 SF
RETAIL B
GROSS AREA
28' - 6"RESIDENTIAL
85' - 8"
MIXED USE
37' - 1"
18658.97 SF
BUILDING
?
591.37 SF
LANDSCAPE
?
463.53 SF
LANDSCAPE
?
1256.85 SF
LANDSCAPE
?
1139.08 SF
LANDSCAPE
?
157.04 SF
LANDSCAPE
?
245.55 SF
LANDSCAPE
?
67.50 SF
LANDSCAPE
?
155.39 SF
LANDSCAPE
?
© 2021 GROUPARCHITECT, INC. ALL RIGHTS RESERVED
SHEET TITLE:
PROJECT No.
CHECKED:
DRAWN:
REVISIONS
CLIENT:
PROJECT:1735 westlake avenue north, suite 200, seattle, wa 98109206.365.1230 | www.grouparch.comORIGINAL SHEET SIZE IS 24"x36" | PLOT DATE:
SHEET DATE:
ISSUE:
HARRINGTON
REDEVELOPMENT
960 HARRINGTON AVE.
NE, RENTON, WA 98056
ZARNOOR
ASSOCIATES LLC
PROJECT ISSUES:
SITE PLAN REVIEW 08/04/2021
8/2/2021 10:33:02 AM
ZONING CODE
ANALYSIS (CITY OF
RENTON)
A0.11
1922
BJP
KJS
08/04/21
SITE PLAN REVIEW SUBMITTAL
CONSTRUCTION OF A RESIDENTIAL MIXED USE BUILDING CONSISTING OF (1) FLOOR OF
COMMERCIAL / PARKING AND (5) FLOORS OF RESIDENTIAL UNITS WITH VEHICULAR AND BICYCLE
PARKING IN ATTACHED GARAGE.
LEGAL DESCRIPTION
TAX PARCEL NO:7227801025
PROPERTY ADDRESS:960 HARRINGTON AVENUE NE, RENTON, WA 98056
LEGAL DESCRIPTION:LOT B, CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-05-015-LLA,
RECORDED UNDER RECODING NO. 20050422900002, IN KING COUNTY WA.
SITUATE IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WA
SIDE (ELEV + ELEV) / 2
NORTH (338.36 + 336.93) / 2 = 337.64'
WEST (336.93 + 331.73) / 2 = 334.32'
SOUTH (331.73 + 335.18) / 2 = 333.46'
EAST (335.18 + 338.36) / 2 = 336.77'
1342.19 / 4 = 335.54' GRADE PLANE
MAX HEIGHT = AVG GRADE PLANE + 70' = 405.54'
BUILDING PROPOSED TOP OF ROOF = 414.1'
(ADDITIONAL SHED, PARAPET, AND ROOF SLOPE WITH
ENCLOSING PARAPET HEIGHTS MAY APPLY)
REFER TO ROOF PLAN FOR ADDITIONAL INFORMATION
ADDITIONAL EQUIPMENT AND PENTHOUSE > 70' (D1)
BUILDING HEIGHT CALCULATIONS
SCOPE OF WORK
PARKING MATRIX
BUILDING HEIGHT CALCULATIONS -4-2-120A
GRADE PLANE FORMULA
FORMULA TO BE USED FOR BUILDING TO DETERMINE AVERAGE GRADE PLANE:
ELEVATION USED IS LOWEST POINT FROM BUILDING TO PL OR WITHIN 6' OF BUILDING
(ELEV A + ELEV A')/2 + (ELEV B + ELEV B')/2 + (ELEV C + ELEV C')/2 +..... = AVERAGE GRADE LEVEL
# OF FACES IN CALCULATIONS
STALL TYPE COUNT
STANDARD - LIFT 14
COMPACT - ADA 1
STANDARD - ADA 2
VAN - ADA 1
COMPACT 25
STANDARD 26
Grand total: 69 69
PROJECT ADDRESS: 960 HARRINGTON AVENUE NE, RENTON, WA 98056
SITE AREA:GROSS SITE AREA=29,359 (0.67 ACRES)
ROW DEDICATION= TBD
NET SITE AREA = TBD
ZONING: CENTER VILLAGE-CV (COMMERCIAL AND MIXED USE)
URBAN DESIGN DISTRICT D
PRINCIPAL USES
NUMBER OF RESIDENTIAL UNITS: 69 UNITS -MULTIFAMILY APARTMENTS
LOT COVERAGE
MAX BUILDING AREA:75% (29,359 X .75 = 22,019 SF) MAX
DENSITY:
MIN RESIDENTIAL DENSITY 20 DU/acre = 13.4 UNITS (.67 X 20)
MAX RESIDENTIAL DENSITY 80 DU/acre = 53.6 UNITS (.67 x 80)
AFFORDABLE HOUSING DENSITY BONUS 4-09-65.D3:
GAIN 1 MARKET RATE DU PER EVERY AFFORDABLE HOUSING DU PROVIDED
30% AFF HOUSING INCREASE 53.6 X .3 = 16 ADDITIONAL UNITS ALLOWED MAX
54 + 16 = 70 UNITS MAX
SEE UNIT MATRIX ABOVE
AFFORDABLE PROVIDED:8 UNITS AFFORDABLE HOUSING DU
MARKET RATE DU GAIN:7 UNITS MARKET RATE DU
TOTAL NET DU GAINED:15 UNITS
DENSITY PROPOSED:54 UNITS + 15 BONUS = 69 UNITS TOTAL (COMPLIES)
SETBACKS:
MIN FRONT (STREET) YARD:15 FT (COMPLIES)
MAX FRONT (STREET) YARD:20 FT (COMPLIES)
FRONT YARD PROVIDED:15 FT (COMPLIES)
MIN SIDE YARD:0 FT (COMPLIES)
MIN BACK YARD:0 FT (COMPLIES)
SIDE/BACK YARD PROVIDED:0 FT (COMPLIES)
CLEAR VISION ANGLE CREATED FROM 20' AT INTERSECTION CORNER
(SEE ARCHITECTURAL SITE PLAN FOR SETBACK PROPOSAL)
BUILDING LIMITATIONS:
MAX GROSS FLOOR AREA COMMERCIAL USE:NONE (COMPLIES)
BUILDING ORIENTATION TOWARDS PUBLIC STREETS (COMPLIES)
HEIGHT:
MAX BUILDING HEIGHT:50 FT OR 70 FT FOR MIX USE VERTICAL BUILDING
BUILDING HEIGHT PROPOSED:76'-2" (SEE BUILDING HEIGHT CALCULATION) (D2)
MAX HEIGHT CELL TOWER (4-4-140.F.2.d) WCF ALLOWED 16'-0" HIGHER THAN ZONING CODE
4-4-150 -RESIDENTIAL MIXED USE DEVELOPMENT STANDARDS
COMMERCIAL MIXED USE STANDARD:
ANY DEVELOPMENT WHEREIN DWELLING UNITS ARE PROPOSED SHALL PROVIDE
COMMERCIAL SF EQUIVALENT TO 50% THE GROSS GROUND FLOOR AREA OF ALL BUILDINGS
ON SITE.
GROSS FLOOR AREA OF LEVEL 1 =6767 SF
50% GROSS COMMMERCIAL REQUIRED=6767 SF / 2 = 3,3383 SF MIN.
50% OF GROUND FLOOR FACING STREET FRONTAGE SHALL BE OF COMMERCIAL SPACE.
MIN. AVG DEPTH OF COMMERCIAL SPACE SHALL BE 30' AND NO LESS THAN 20' AT ANY POINT.
PROPOSED AVG DEPTH APPROXIMATE 28' (D3)
PROPOSED DEPTH > 20' (COMPLIES)
PROPOSED LENGTH %142 / 274 = 51.8% (COMPLIES)
MIN. FLOOR TO CEILING HEIGHT OF 18', AND MIN. CLEAR HEIGHT OF 15'
PROPOSED HEIGHT 18' FLOOR TO CEILING AND 15' CLEAR
RESIDENTIAL SPACES FOR RESIDENTS OR THEIR GUESTS IS LIMITED TO 25% OF THE OVERALL
FACADE LENGTH ALONG A STREET FRONTAGE OR PRIMARY FACADE.
PROPOSED RESIDENTIAL FACADE % =85.66' RES / 268.7' TOTAL FACADE
=31.9% (D2)
4-4-070.F1 -STREET FRONTAGE LANDSCAPING:
10 FT REQ'D ALONG ALL PUBLIC FRONTAGES CONTAINING TREES SHRUBS AND LANDSCAPING.
PROVIDED LANDSCAPE STRIP =10' (COMPIES)
4-4-070.F2 -STREET FRONTAGE LANDSCAPING IN ROW ON PUBLIC STREETS:
STREET TREES IN THE ROW PLANTER WILL ALSO BE REQUIRED, MIN WIDTH BETWEEN CURB AND
SIDEWALK DETERMINED BY 4-6-060.
4-4-080.B.1.b -PARKING LOADING AND DRIVEWAY STANDARDS
PARKING SHALL BE PROVIDED TO NEW STRUCTURES OUTSIDE CENTER DOWNTOWN. REQUIRED
PARKING LOCATED UNDER BUILDING / FIRST LEVEL OR IN ATTACHED / DETACHED STRUCTURE. NOT
TO BE LOCATED BETWEEN BUILDINGS AND PUBLIC UNLDESS LOCATED IN GARAGE STRUCTURE.
4-100.E.2 -NO SURFACE PARKING PERMITTED
NO SURFACE PARK PERMITTED BETWEEN PRIMARY BUILDING AND FRONT PROPERTY LINE
4-4-080.F.8 -PARKING STALL TYPES, SIZES, AND PERCENTAGE ALLOWED / REQUIRED
STANDARD PARKING STALL DIMENSIONS FOR STRUCTURED PARKING PER 4-4-080.F.8.b SHALL BE:
8.33' WIDE X 15' LONG (STANDARD STALL)
7.5' WIDE X 12' LONG (COMPACT STALL)
COMPACT PARKING STALL DIMENSIONS FOR STRUCTURED PARKING PER 4-4-080.F.8.c.ii SHALL BE:
MAX 30% COMPACT PARKING ALLOWED
ACCESSIBLE PARKING STALLS -PROVIDE PER WA ST CODE STANDARDS, IBC-WSA CH 11.
4-4-080.F.9.b -AISLE WIDTH STANDARDS
AISLE WIDTH AT 90 DEG PARKING TO BE MIN 24 FT WIDE
4-4-080.F.10.d -NUMBER OF PARKING SPACES REQUIRED
PARKING QUANTITIES FOR ATTACHED DWELLINGS IN ALL OTHER ZONES:
MIN. STALLS = 1.0 SPACES / STANDARD DU 61 X 1.0 = 61 SPACES MIN.
MIN. STALLS = 1.0 SPACES / 4 AH DU 8 X .25 = 2 SPACES MIN.
MAX. STALLS = 1.75 SPACES / DU 68 X 1.75 = 119 SPACES MAX.
PARKING QUANTITIES FOR EATING AND DRINKING ESTABMLISHMENTS:
MIN. STALLS = 10 / 1000 SF DINING AREA 10 X (1200 / 1000) SF = 12 SPACES MIN.
PARKING QUANTITY REQUIRED:MIN. 75 SPACES
PARKING QUANTITY PROVIDED:69 SPACES (8% PARKING ADJUST D5)
PARKING % COMPACT PROVIDED:26 COMPACT / 70 TOTAL = 38% (D4)
4-4-080.F.11.a -NUMBER OF BICYCLE PARKING SPACES REQUIRED:
0.5 BICYCLE SPACES / ATTACHED DWELLING UNIT SHALL BE PROVIDED
BICYCLE PARKING REQUIRED:69/2 = STORAGE FOR 35 BIKES REQUIRED FOR RESIDENTS
12X .1 = STORAGE FOR 1 BIKE REQUIRED FOR COMMERCIAL
BICYCLE PARKING PROVIDED:34 BIKE STALLS
(2) 2 ADA BIKE STALLS (COMPLIES)
4-4-090.C -GENERAL REQUIREMENTS
ARCHITECTURAL DESIGN OF OUTDOOR STRUCTURE SHALL BE CONSISTENT WITH ARCHITECTURE
OF PRIMARY BUILDINGS ON PROPERTY. COLLECTIONS AND COMPACTOR AREAS SHALL BE
SCREENED BY MIN 6 FT HIGHT FENCE OR WALL. ENTRY INTO THE ENCLOSURE SHALL BE AT LEAST
12 FT WIDE. MIN. HEIGHT WHERE ENCLOSED TO BE 15 FT.
FENCE, HEIGHT AND DOORWAY PROVIDED (COMPLIES)
4-4-090.D -MULTI-FAMILY -ADDITIONAL REQUIREMENTS FOR DEPOSIT AND COLLECTION AREAS
MIN SIZE TO BE 1.5 SF / DU FOR RECYCABLE DEPOSITS AND A MINIMUM OF 3 SF / DU FOR REFUSE
DEPOSIT AREA. ADDITIONALLY, AT LEAST 1 DEPOSIT AREA/COLLECTION POINT FOR EVERY 30 DU.
4-4-090.E -COMMERCIAL -ADDITIONAL REQUIREMENTS FOR DEPOSIT AND COLLECTION AREAS
MIN SIZE TO BE 5 SF / 1000 SF FOR RECYCABLE DEPOSITS AND A MINIMUM OF 10 SF / 1000 SF FOR
REFUSE DEPOSIT AREA. A TOTAL MIN. OF 100 SF SHALL BE PROVIDED FOR COMMERCIAL DEPOSIT
AREA
REFUSE / RECYCLING AREAS REQUIRED:
69 DU x 1.5 SF / DU = 103.5 SF MIN RECYCLE COLLECTION
69 DU x 3.0 SF / DU = 207 SF MIN REFUSE COLLECTION
69 DU = MIN 2 COLLECTION AREAS REQ'D
3479 SF / 1000 SF X 5 SF = 17.4 SF MIN RECYCLE COLLECTION
3479 SF / 1000 SF X 10 SF = 34.8 SF MIN REFUSE COLLECT
(100 SF MIN. REQUIRED FOR COMMERCIAL COLLECTION)
REFUSE / RECYCLING AREAS REQUIRED:TOTAL AREA = 410.5 SF
REFUSE / RECYCLING AREAS PROVIDED:TOTAL AREA = 415 SF (COMPLIES)
ONE CENTRALLY-LOCATED DEPOSIT AREA ON EACH LEVEL
SITE INFORMATION
CV ZONING DEVELOPMENT STANDARDS (4-2-120A):
SCALE:1" = 50'-0"
ZONING - PLAN HEIGHT CALC DIAGRAM
LANDSCAPING -4-4-070
4-4-095.D.1 -SURFACE MOUNTED EQUIPMENT GENERAL SCREENING:
ALL ON SITE-SURFACE MOUNTED UTILITY EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW.
SCREENING TO CONSIST OF EQUIPMENT CABINETS ENLCOSING UTILITY EQUIPMENT, SOLID
FENCING OR WALL AS HIGH AS EQUPIMENT, OR LANDSCAPE VISUAL BARRIER. SCREENING TO
ALLOW EASY ACCESS. MATERIALS TO BLEND AND GO ALONG WITH BUILDING.
4-4-095.E.1 -ROOF MOUNTED EQUIPMENT GENERAL SCREENING:
ALL OPERATING EQUIPMENT ON ROOF OF ANY BUILDING SHALL BE ENCLOSED AS TO SCREENED
FROM THE PUBLIC VIEW
SHIELDING SHALL CONSISTS OF ROOF WELLS, CLERESTORIES, PARAPETS, WALLS, SOLID FENCING
OR OTHER SIMILAR SOLID, NONREFLECTIVE BARRIERS OR ENCLOSURES.
SCREENING -4-4-095
PARKING 10-10-13 & 4-4-080
BICYCLE PARKING MATRIX
REFUSE & RECYCLING -4-4-090
ACCESS TO SITE IS PROPOSED VIA AN ACCESS EASEMENT , OVER THE PROPERTY TO THE SOUTH, OFF
OF HARRINGTON AVE NE AS WELL AS DRIVEWAY ACCESS OFF OF NE SUNSET BLVD.
ACCESS EASEMENT #20050422900002
PARKING AGREEMENT LINE ON EASTERN PL REC. NO. #9809221300 PER REC. NO. 20050422900002 TO BE
UPHELD WITH PROVIDING PARKING ALONG EAST PL AT GRADE LEVEL.
SEE URBAN DESIGN REGULATIONS FOR MORE INFORMATION
ACCESS 4-3-100
CITY COR MAPPING SYSTEM DOES NOT CONTAIN ANY CRITICAL AREAS ON THE PROPERTY OR WITHIN
NEARBY VICINITIES.
CRITICAL AREAS -4-3-050
SCALE:1" = 30'-0"
ZONING - BUILDING HEIGHT DIAGRAM
STALL TYPE COUNT
BIKE RACK - FLOOR MOUNTED / 2 BIKE CAPACITY ADA 3
BIKE RACK - WALL MOUNTED 33
OCCUPANCY LEVEL AREA
COMMERCIAL LEVEL 1 3470.76 SF
3470.76 SF
OCCUPANCY LEVEL AREA
RESIDENTIAL LEVEL 3 12348.10 SF
RESIDENTIAL LEVEL 4 12348.10 SF
RESIDENTIAL LEVEL 5 12348.10 SF
RESIDENTIAL LEVEL 6 11211.49 SF
RESIDENTIAL LEVEL 7 12075.87 SF
60331.66 SF
DEPARTURE MATRIX
UNIT # COUNT
A.1 5
A.2 5
B.1 20
B.2 5
B.3 5
B.4 2
C.1 5
C.2 5
C.3 5
C.4 4
C.5 3
C.6 3
C.7 1
D.1 1
STANDARD: 69
TOTAL: 69
SCALE:1" = 50'-0"
ZONING - BUILDING COVERAGE DIAGRAM
BUILDING LOT COVERAGE AREA % OF TOTAL SITE AREA
BUILDING COVERAGE 18667.38 SF 64%
NON-BUILDING COVERAGE 10691.02 SF 36%
29358.41 SF
BUILDING LOT COVERAGE CALCULATION
SCALE:1" = 50'-0"
ZONING - COMMERCIAL OCCUPANCY DIAGRAM
GROSS COMMERCIAL SPACE CALCULATION
OCCUPANCY TYPE AREA % OCCUPANCY AREA
COMMERCIAL 3697.40 SF 52%
MECHANICAL/STORAGE 882.04 SF 12%
RESIDENTIAL 2534.63 SF 36%
7114.07 SF
(COMPLIES)
(COMPLIES)
(CONDITIONAL USE PERMIT REQ'D)
(ADMIN. MODIFICATION OF STANDARDS)
(ADMIN. MODIFICATION OF STANDARDS /
PARKING STUDY)
(ADMIN. MODIFICATION OF STANDARDS)
(ADMIN. MODIFICATION OF STANDARDS)
(ADMIN. MODIFICATION OF STANDARDS)
SCALE:1" = 50'-0"
ZONING - LANDSCAPE DIAGRAM
LANDSCAPE AREA
BUILDING LOT COVERAGE AREA % OF TOTAL SITE AREA
BUILDING 18658.97 SF 64%
IMPERVIOUS 6623.20 SF 23%
LANDSCAPE 4076.32 SF 14%
29358.49 SF