Loading...
HomeMy WebLinkAboutR-404216A0 z O z LJJ rr rU) V O J O rr n 0 Lf� U SS-WAT CROSSING GRADE = 27.02, 2.0' COVER CROWN WAT = 23.00 IE WAT = 21.95 CROWN SS = 25.01 PRIVATE SS CLEANOUT #3, SS I.E. = 24.30 I N:175670.68 458• E0a 1291344 9 1z81jQ! 4& 111 a RD L_--- 4335F PRIVATE 8"0 PVC W W ®3.83q W o CB#13, TYPE 2, 60"0 N:175650.51 - - - - - - - - - - --LA291 SD - SD SO '�U SD - SO D S ��0 -So 0� / PRIVATE GREASE INTERCEPTOR VENTS PER MANUFACTURERS O - ss ss SPECIFICATIONS / G RIVATE GREASE INTERCEPTOR t`�QJ 14 0 CASTLE SINGLE VAULT SYSTEM ll OR APPROVED EQUAL - SEE DETAIL SHT C5.0B sN N:175606.83 #3 '� 1-1 A96 'E- E:1291285.56 4,&-LF PRIVATE 8"0 PVC ® O ss 1.0% O PRIVATE SAMPLING TEE, 3- N:175601.52 Pv0 ® E 1291276.35 8 m �� PAIN F� - EX. SSMH-S TYPE 2-48 STA: 0+10.00, 0.0 ' I - SANITARY SEWER EXTENSION PRIVATE SSMH#3, 48"0 TYPE 1 N ;;;66 4 A �9. N:175647.70 L E:12M327.72 44' 6" THICK ETHAFOAM PAD 22 -24-LF PRIVATE SS CLEANOUT 11, PRIVATE SS CLEANOUT #2, „ „«,n ,� PRIVATE 8" 0 N:175671.66 N:175671.72 .---6*r� �J----�56�3�8- T PVC C900 E:12MM.9 E1291463.7 ® 9r86*1.4X RD RD p RD RD RD 10 LF PRIVATE 8"0 PVC 2.00% PVC a 1.007. -&4. LF PRIVATE 8"0 60-5✓ LF PRIVATE 8"0 PVC ® �� a7% 67 ---- --- PRIVATE SSMH#1, 48"0 TYPE 1 . 75663.98 N �5ss+38 -F- ,P94 396 96 E:12M397.45 W - W W W W W i3VdW0' CB#12.--TYPE2.48"0 1 ' L - - -4t47566a67 SS-WAT CROSSING GRADE = 27.70, 2.64' CO> R PRIVATE SSMH/2- TYPE 1 CROWN WAT = 23.79 (POTHOLED) 1 _ IE WAT = 22.74 CROWN SS 25.011 SS I.E. = %4-30 SS STM CRO Wt .64 COVER CROWN STM 21.41 SS I.E. = I SCALE: 1 " = 20' 30-T WATER NOTE: - _$ / - WATER MAIN IS SHOWN PER DESIGN,- / CONTRACTOR SHALL POTHOLE AND FIELD / VERIFY THE DEPTH OF EXISTING WATER MAIN. 28 / CONTACT ENGINEER IF DISCREPANCIES OR PROPOSED GRADE / CONFLICT EXIST. �- SS-WAT CROSSING GRADE = 27.70, 2.64' COVER OWN WAT = 23.79 (POTHOLED) IE WAT = 22.74 22-24- LF 26 CROWN SS =-96.86-25.01 pRIVafE / SS I.E. = -2+35- / 24.30 PVC C9 0 1 Cl- 4 LF qt W Ii i / PRIVATE 800 PVC 24 - i A 20 EX. SSMH-SW2, TYPE 2-48"0 STA: 0+10 0.00' RIM = 26.94- 25.74 18 I.E. 8" (S) = 21.36, IN I.E. 8" (E) = 21.36, IN (NEW) I.E. 8" (NW) = 21.26, UT - LADDER - EAST 16 14 12 PROLOGIS RENTON 9 601 MONSTER ROAD SW A PORTION OF THE NW 1 /4 OF SECTION 24, TOWNSHIP 23, RANGE 4 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON SEE SHEET C5.OB FOR - AS BUILT WATER IN SS 00 STA: 0+5as, SS Co STA: 0+6a6, 11191- THIS AREA. 0.61 RN1m 26.12 RIM= 25.02 C PVC (E&VO - 22.94 C PVC (E&W) = 23.04 I CONNECT TO EXISTINGOf BUILDING SEWER LINE25 'WYE" I.E. = 24. 71WITH 26.06w 25.78 CLEANOUT "WYE"3LF h6" ---- -------- ------------ "06"xl-1/4" 26.246" REDUCERPVC / "P" 26.25RIM = 29.78 26.TRAI.E. = 24.6t 4LF 4"34'x42' ® 1.0' NEW 6" C NC.PVC PAD FOR COMPAC OR. w 38LF 1-1/4"0 "SLOPED TO DRAIN PVC FORCEMAIN Q E-ONE MODELINA0133POI STA:0+510, 0.71 GRINDER PUMP (OR I 26.25 �� 26.24 RIM= 26.18 APPROVED EQUAL) -SEE PUMP TAIL 1 SHEET C5.OB YSTEM POWER & 14r� SQUARE DRAIN REMOVE AND REPLA E 26.25 w/ BOTTOM OUTLET 34'x60' EXISTING C C. CONTROL BOX PER MANUFACTURERS 7 RIM =X�7 TRUCK APRON. RE FOR TRASH COMPA RADE OR. SPECIFICATIONS. TRAPZILLA M- C REMOVE 35LF OF TRENCH GREASE INTERCEPTOR (OR STA: +58.Z, 0.71 DRAIN. INSTALL NEW CAP APPROVED EQUAL) - SEE RIM 26.07 AT END. DETAIL 2 SHEET C5.OB TRASH COMPACTOR PAD GRADING & SEWER PLAN �21111��Z iL Q W C -I 6748-LF 60-55-.LF RIVATE_ P _ _ 0.796 BUILDING FINISH FLOOR 30 ELEV = 29.78 30 - - - - - - - - �I II I R6 TE 8 "0 P C ® 1.007 -- -- I I �.u7fi 12»0 D I. WATER AIN f I I _ 4-- I 1 I 8�.;{�1 52-49-LF I _ - - 14 I I 8"� PVC PRIVATE $ro TVA -1 - � I I _per-C9 N 14 ®a.gg1. I --- ---- ---- ----- ---- ---- - 1 1 SS-STM BOSSING I I GRADE = 27.72, 2.6 ' COVER 1 1 IE STM=-19.8i-19.78 1 CROWN STM=-24.44-21.41 SS I.E. 24.25 - - - - - - - 120 - - - - - - - - - - 18"0 CPEP SD- 15 0.11% PRIVA SS CLEANOUT 11, 1 PRIVATE SSMH#2, 48"0 TYPE 1 STA:2+86.5, 5.81 1 RIM = 29.06 'RIVATE SAMPLING TEE 1 RIM = STA:1+6 .8, 1.4'L I.E. 8" W = 25.88 I 18 STA:0+74.3, 2.2R I I.E. 8" (E) -IN 24. , PVC L 1 'IM �_ 27�-i- 26,79 RIVATE SSMH#1, 48 0 TYPE 1 " - , 011T 22.5 I.E. 8" (SW) - 24..45� our 4.46, PVC + W.99 , 1A90 E. 8" E UT 22.52, PVC PRIVATE SS H#3, 48 0 TYPE1 IM = 29.46r 29.31 () _ CB#13, TYPE 2, 60"0 14 RIM 27.46 ' STA:1+ 4, 0.8 R / BACKFLOW VALVE - . 6, CPEP I.E. 18" ( =}8- RIM j� 27. .:- 8" (E) =P&P9 IN 25.02, P 16 J19.76 CPEP I.E. 18" (E) _ +9-�8- I.E. 8 (NE) 24.29, IN 24. 6, PVC E. 8" (N) _ � IN 25.02, PRI VA TE GREASE IN TERCEP OR I. E. 8" (N W) 9.46, IN 23. 7, PVC �, Ell20.56, PVC I.E. 8 = . _ Pyc10 LF E. 8 W = , OUT 24.92, VC OR PPROr%v EQUA - LF I.E�n (SW) PRIVATE 8"0 PVC CB 12, TYPE 2, 48"0 SEED TAIL #3 SHT C .06 " PRIVATE SS LEANOUT #3, 0 2.00% RIVATE SS CLE NOUT #2, # PRIVATE 8 0 PVC RIM = 28,74 ' 34.8'R STA: 2+19.7, �- 14 . , 3.83% RIM = �8- 2 30 7.3'L LE. 18" (E) 19.94, CPEP MULTIPLE ACCE S LIDS, SEE DETAIL RIM = 27.44 I.E. 8" (S) = 25 40, OUT I.E. 18" (W) - 28-12 19.94, CPEP FOR RIMS I.E. 8" (SE) 24.80, OUT I.E. 4 (S) = 2; .2 9- 26.34, PVC IE 8" (NE) =SIN 22.71, PVC BAFFLE ELEV. IE 8" (SW) = 2249, OUT 22.52, PVC BAFFLE ELEV. 12 �FN 00n . Co O N NN �0 CD0 C3) 00N Co 00 CO Op O 0000 O t\ COLn t\ CO d- Co I�'V- N 03 N Co NO Do Od N C4 co N 00 N co N CN Do04 CN N Do 04 N 00 NN NN SANITARY SEWER PROFILE HORZ. 1 "=20' VERT. 1 "=2' 28 PATJ 24 22 20 I� I 12" 0 ROOF DRAIN LINE BUILDING FOUNDATION 3442' NEW 6T CONC. PAD FOR COMPACTOR. SLOPED TO DRAIN SCALE: 1" = 20' 30 28 26 - _T4r Q•A � REMOVE AND REP �DRAIN SQUAR CZ 11151 w/ BOTTOM OUTLET 34 x60 EXISTING CONC. RIM = z1(r9� 25.97 TRUCK APRON. REGRADE U REMOVE35LF OF TRENCH FOR TRASH COMPACTOR. - DRAIN. LL NEW -CAP" 24 6" CLEANOUT "WYE* AT ENE. 6"xl-1/4" REDUCER CTR. INLET = 0.2;- INLET CAWD 90T. OF S=IURE = 24.04 = 29.78 -RIM I.E. = 24.6t LE= 18 CTR. OUTLET = INLET CALCD BOT. OF S1RU = 24.08 CTR. OUTLET = 3LF 4"0 PVC CTR.INLET = " -Ipi-� 22 CONNECT TO EXISTING 6- 2Z PVC ®1 OX BUILDING SEWER LINE "WYE" TRAPZI MODEL#TZ-160-ECA WITH I.E. = 24.5t GREASE INTERCEPTOR OR f ONE MODEL#NAO133P01 APPRO EQUAL) - SEE GRINDER PUMP (OR DETAIL SHEET C5.OB APPROVED EQUAL) - SEE STA:O+ a71. DETAIL 1 SHEET C5.OB STA-0+52.10, 011. ss co r- 5411. 0281 20 RIM= 26.18 0.6'L M- 26.12 Ir (EW - 2294 . _ 4r PVC (EMt ,*04 � O CD N N N N COMPACTOR DRAINAGE PROFILE HORZ. 1 "=20' VER T. 1 "=2' RECORD DRAWING NOTE: THIS CONSTRUCTION RECORD DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY INNOVA ARCHITECTS AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEYED 1 REVISED PER CITY COMMENT LETTER DATED 12/21 18 JRE 04 02 1s 1 INFORMATION AND DOCUMENT D FIELD REVISIONS. 2 REVISED PER CITY COMMENTS DATED 05 07 19 JRE 06 03 19 CONSTRUCTED 1 1 DUCTED 3 REVISED PER CITY COMMENTS TO C2.0, C6.0 & C6.2 JRE 06 21 19 4 REVISED PER CITY COMMENTS TO C6.0 JRE 06 25 19 5 REVISED PER CITY COMMENTS TO NGPA & WALL HEIGHTS JRE 07 23 19 6 REVISED WATER QUALITY TREATMENT VAULT C3.0, C3.1, C3.4, & C3.5 JRE 08 20 19 7 CONSTRUCTION COORDINATION SET JRE 10 21 19 8 CONSTRUCTION COORDINATION SET - PSE/SDWLK REVISION JRE 12 20 19 8A REVISED WATER CONNECTION PER CONFLICT WITH HP GAS MAIN STN 10 30 19 9 PSE/SDWLK REVISION CITY COMMENTS C6.0 & C6.2 JRE 1 14 2020 10 CONSTR. COORD. REVISED ROOF DRAIN CLEANOUTS, ADDED CB#7A JRE 1/16/2020 SURVEYED: SCALE: 1 a = 20' 11 REVISED WATER SERVICE LINE TO BUILDING JRE 5 13 2020 DESIGNED: J. Eaves/J. Hein 12 REVISED ADA RAMP DETAIL 2, SHEET C6.2 JRE 7 24 2020 13 REVISED UTILITIES FOR TENANT IMPROVEMENTS JRE 8 27 2020 / / J. Eaves/J. Hein ONE INCH 14 REVISED PER CITY TENANT IMPROVEMENT COMMENTS JRE 9/15/2020 CHECKED: S. Nelson AT FULL SCALE IF NOT SONE INCH CALE ACCORDNHGLY NO. REVISION BY DATE APPR APPROVED: 0 10 20 40' Know what's below. 1°-20' Call before you dig. HORIZONTAL: HAD HAD 1913/1991 ' CITY OF RENTON DATUM Planning/Building/Public Works Dept. 14'-6" x 8' CONC SLAB - FOR ELECTRICAL - REFER TO STRUCTURAL i PLANS SUBMITTED FOR OLLARDS, TYP. 2 TENANT IMPROVEMENTS- - LACES _ - - - UNDER SEPARATE PERMIT. N 14' -6" x 40' CONC SLAB - REFER TO STRUCTURAL PLANS N SUBMITTED FOR TENANT / I ° IMPROVEMENTS UNDER ° SEPARATE PERMIT. t 1 ° I I ° ° @,� 3"RBA IN ABOVE GROUND HEATED "HOT I BOX" (2'-2"x5'-10") PER I 3 / C.O.R. STD. PLAN 350.2 I I3" DOMESTIC I METER PER C.O.R. I STD PLAN 320.4 I L ° I 14'-6" x 20' CONC SLAB - REFER TO s STRUCTURAL PLANS ° SUBMITTED FOR TENANT 3 ° , IMPROVEMENTS UNDER SEPARATE PERMIT. WEST WATER 3 SERVICE �• Mac, Q !4�$ 0 ram_ f SCALE: 1 " = 20' Q+ 0 RECORD DRAWING 03-15-2021 REUSE OF DOCUMENTS 14S DOCUMENT HAS BEEN SIM ElECTROWALLY IN ACCORDANCE NRH wAC 196-23-070 AND CHAPTER 19.34 RCW. UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT 1HLL INVALIDATE THE DOCUMENT, MY CERI1FICATION AND SMILATURE, THE IDEAS AND DESIGNS NWRPORATED HEREIN, AS AN INSTRUMENT OF THE PROFESSIONAL STRVICE, IS THE PROPERTY OF NNOVA ARCHITECTS AND IS NOT TO BE USED, N NHIOLE OR IN PART, FOR ANY OTHER PRO ECT WTHOUT NRITTEN AUTHORIZATION OF INNOVA ARCHITECTS. architects 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 253-572-4903 ient: PROLOGIS 12720 Gateway Dr., Suite 110 Tukwila, WA 98168 206-414-7625 S-404203A W-404203A R-404216A IN COMPLIANCE WITH CITY OF RENTON STANDARDS H H DEVELOPMENT ENGINEERING Bbannwarth 10/28/2020 z PROLOGIS RENTON 9 601 MONSTER ROAD SW Record Drawing documents 03-15-2021 ADDITIONAL TENANT UTILITY IMPROVEMENT PLAN z W V J DATE 11/16/18 F1ELDBOOK: PAGE: O J DRAWING NO: C5.Oa O SHEET: OF: 16 51