24" DIAMETER J
MANHOLE ACCESS
W/TYPE 2-48"
BARREL AND GRATED
OPENING (TYP.)
i
,12" PVC OUT
15'
156'
65.8'
VAULT SECTIONS
FOR
UW MEDICINE - VALLEY MEDICAL CENTER
NORTH GARAGE EXPANSION
23.7'
zi H zI H Q z
>
>
>
a
a
a
00
00
---------------------------
00
RECORD DRA WING
51.5'
O .° G C .Q
IE=85.0
Ln
IE=85.0 IE=85.0
TYP. LADDER LOCATION
76.90
z
76.90
76.90
5% MIN. ,,_� 04
i 5% MIN.
5 x10 ACCESS GRATE
0.00% LONGITUDINALLY LEVEL
(BOLTED DOWN)
IE=78.0
TYP. LADDER LOCATION
FLOW RESTRICTOR RISER PER DETAIL THIS SHEET
Z
4'x4' SUMP
6�.
IE=85.0
LO IE=85.0
d ° o .d ° c - .Q
°. -
25---------------------------
110.17'
PLAN VIEW
43.33'
24" DIAMETER 77.50 i
MANHOLE ACCESS
W/TYPE 2-48"
BARREL AND GRATED
OPENING (TYP.)
SCAI F- 1 "=1 n' nA" nu urrrn
NU 1 tv
SEE STRUCTURAL PLAN FOR CONSTR
4 REVISED PER AS —BUILT CONDITIONS
3 CP-03
y CP-02
1 ADDENDUM #2
Rol
REVISION
SURVEYED:
BCE
CK
0911JI17
AS
DESIGNED:
ZTW
ZTW
02/24/17
AS
ZTW
01/30/17
AS
DRAW
ZTW
11/04/16
AS
CHECKED:
AS
BY
DATE
APPR
APPROVED:
AS
4" PERF. PVC
FOOTING DRAIN
1 77.50
I
I
PROVIDE LADDER PER CITY STANDARD
1 204.60 TYP. 4 LOCATIONS
3/4" CRUSHED DRAIN ROCK
18"
'—I I FABRIC FILTER
ao III 4" PREFPRATED DRAIN PIPE TAKEN TO
I —1 —1- APPROVED POINT OF DISCHARGE
FOOTING DRAIN DETAIL
NTS
N�
REMOVABLE WATER —TIGHT
COUPLING
6" MAX.
"—PLATE WITH ORIFICE
AS SPEC. BELOW.
ELBOW DETAIL
MAX WS EL=86.5 FIELD VERIFY LOCATION
FOR ATTACHMENT OF SHEAR
GATE HANDLE TO WALL
OF VAULT
5'x10' ACCESS GRATE
(BOLTED DOWN) 4" ELBOW, SEE DETAIL ABOVE04
EL = 83.0
ORIFICE DIA. = 1 CLEANOUT SHEARGATE
HANDLE TO BE HUNG
FROM LADDER FOR
EASIER ACCESS. HANDLE
MUST BE ACCESSIBLE
FROM THE SURFACE
WITHOUT ENTERING THE
a
VAU LT.
BOTTOM OF LID a�-
EL=87.0 PIPE SUPPORTS:
MAX. W.S. EL=86.5 3"xO.090 GAGE 12" MIN.
BOLTED OR IMBEDDED
2" IN WALL
a MAX. 3'-0" SPACING 12" CMP
(MIN. ONE SUPPORT) 12" SD
,a
CLEANOUT GATE: IE=78.0
�. 8"DIA. SHEAR
GATE
IE=78.0 12" CMP
STANDPIPE
2' MIN.
24'
RESTRICTOR PLATE
WITH ORIFICE
EL = 74.0
DIA.
a
12" OUT
4" PERF. PVC IE=78.0
FOOTING DRAIN FLOW RESTRICTOR RISER
PER DETAIL THIS SHEET
STATIC W.S. EL=78.0
BOTTOM OF WALLS M\N•
EL=77.5
a
° d9
a °
SCALE:
SECTION A -A
4" PERF. PVC FOOTING
DRAIN
(SEE DETAIL ABOVE)
SCALE: 1 "=10' HORIZONTAL 1 "=2' VERTICAL
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
1 .1
FLOW RESTRICTOR RISER
1 "=2'
SADR
W A
�F
Sy1
24661
/STE��G\���
NA L
3/13/2019
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
BY: DATE
BY: DATE
N
..w
00
Z j
z�
zw
gN
J
X
L
Zw
g�
N
z
0 W
O
cV
00
000000
Ofz
I
I
ui Ld
Q
�LoLin
5:z
��
LO
V-)
w L
Li
>
Uu
8
BY: DATE: 0
0
I
O
BY: DATE:
w
DATE: Q_
VAULT SECTIONS 03/13/2019 cm
UW MEDICINE - VALLEY MEDICAL CENTER FIELDBOOK:
NORTH GARAGE EXPANSION PAGE z
DRAWING N0: m
400 SOUTH 43rd STREET °
7
RENTON, WASHINGTON 98055 SHEET: A ^ OF: -1 U4
R-393709