HomeMy WebLinkAboutR-3937110 0 O I �O H W N O Z M O 7 W U m I I iv U to a- IY7 rn 0 N E 0 0 3 0 I N rn 0 Do a N rn 0 DO i 0 O O 00 Q � w 17 BOLT -DO Wtd HOLE (TYP.) 5f6" - 11 NC_ SEE ❑ETAIL 8 NOTE.2 a TOP SECTIDN REC ESSED ALLEN HEAD CAP SCREW ^ 1�. 54"-17NCx2" 314- GRME 1-0 MOTES I. This Frame Is designed to accommodate 20" x 24" grates or covers z. Provide two holes In the frame that are vertically aligned with t ha grate or cover slots. Tap each hole to accept a 518" - 11 NO x 2" alen head cap screw. Location of bolt down holes varies among different manufacturers. 3. Refer to Standard SpedfloMon 9-05.15(2) for additional requirements. ISOMETRIC VIEW 7 516" 1 9 FRAME O#R 2 102" SECTION DETAIL 1301ILT-DOWN1DETAIL ' } PUBLIC WORTS RECTANGULAR FRAME STD. PLAN - 204.00 DEPARTMENT It•(ARCIi 2(}0 2" CLA_` *2" TO 6" C OR C 1' V 2.5' V I 1' MIN MIN FMIN MIN MIN 11 S V IN FACE EDGE C LASS 'E' L -ASS 'B' 6.5' MIN. 2" DEPTH OF GRIND OR SAWCUT AND REMOVE 6.5' MIN- -2.5' MIN MIN MIN MIN MIN 2" CLASS 'B' CRUSHED ROCK, FLC3WAL-- Oil AS REQUIRED BY ENGINEER FOR MINIMUM STANDARDS, SEE DWG# HR-05, SP PAGE H032 OF CURB OR OF PAVEMENT ENTER LINE OR ANE LINE S* D SURFACING TOP COURSE TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT ADOPTED CITY OF P"TON ST&NOMM PW,WS LIST DAn! 02/05 DWG. NAME: H032--1 SP PAGE: H032.1 CONSTRUCTION NOTES AND DETAILS FOR UW MEDICINE -VALLEY MEDICAL CENTER NORTH GARAGE EXPANSION RECORD DRA WING Y � N Y < g m /z 0 FRAME AND VANED GRATE 5 s• 6" OR 12" ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTANGULAR ADJUSTMENT SECTION u � #3 BAR EACH CORNEF #3 BAR EACH SIDE t!l RAP FAr.W PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN #3 BAR HOOP PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP * 12" (STD. SPEC. 9-05.20) SOLID WALL PVC 15" (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC, 9.05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES 1. As acceptable alternatives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate must be Installed with the flange down. 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be grouted full after the basin has been placed. 8. All grade rings and castings shall be set in mortar in accordance With Standard Specification 9-04.3. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION ti�Y O STD. PLAN - 200.00 + PUBLIC WORKS CATCH BASIN TYPE 1 `` DEPARTMENT ��IvzO$ MARCH 2O08 4" FOOTING DRAIN DETENTION VAULT GONG. COL. TIEBACK ANCHOR DRAINAGE PANEL BETWEEN PILES SEE SPECS DRAIN AND J WEEP PIPE FOOTING DRAIN DETAIL NOT TO SCALE 4 REWSED PER AS -BUILT COND177ONS 3 CP-03 2 CP-02 ADDENDUM #2 Rol REVISION i a8-1t�uv I I I 3 MECH. PLENUM FLOOR - s2.15 5EE PLAN FOR EXTENT I _LEVEL 4 I I 0 BOTTOM OF VAULT SLAB CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD N RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION tO GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP 0 48'. SC, 68', 77, 84.OR 96' o MORTAR (TYP.) STEPS OR , > LAD DEER � o o ..... z FILLET m, � REINFORCING STEEL (TYP.) N 12' GRAVEL BACKFlLL FOR PIPE ZONE BEDDING SEPARATE BASE INTEGRAL BASE CAST -IN -PLACE PRECAST WITH RISER 'O" RING 12" GRAVEL BACKFlLL FOR 6"= PIPE ZONE BEDDING b° SEPARATE BASE PRECAST CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS BASE REINFORCING STEEL In2/fL IN EACH DIRECTION -• SEPARATE BASE INTEGRAL BASE 48" 4" 6" 36" 8" 0.23 0.15 54" 4.5" 8" 42" 8" 0.19 0.19 60" 5" 8" 48" 8" 0.25 0.25 72" 6" 8" 60" 12" 0.35 0.24 84" 8" 12" 72" 12" 0.39 0.29 96" 8" 12" 84" 12" 0.39 0.29 NOTES 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate must be installed With the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5• All grade rings, risers, and castings shall be set in mortar in accordance With Standard Specification 9-04.3. 1`ty O PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSP tD SOLID WALL PVC Q2 PROFILE WALL PVC 48" 24" 30" 24" 27" 30" 54" 30" 36" 30" 27" 36" 60" 36" 42" 36" 36" 42" 72" 42" 54" 42" 36" 48" 84" 54" 60" 54" 36" 48" 96" 60" 1 72" 1 60" 36" 48" (D Corrugated Polyethylene Storm Sewer Pipe (Std. Spec. 9-05.20) (Std. Spec. 9-05.12(1)) (Std. Spec. 9-05.12(2)) + & + PUBLIC WORKS CATCH BASIN TYPE 2 �iVZO� DEPARTMENT STD. PLAN - 201.00 MARCH 2O08 SADR �F W A Sy1 yC_A 24661 O�Ffs Or' / S T R NA L 1 \� 3/13/2019 FINI5HGR. APPROVED FOR CONSTRUCTION ----I LEVESUBJECT TO ERRORS AND OMISSIONS - 6T-10" _ BY: DATE: ''F:GOTIN DRAIN"'-"' DG RAIN64'-1" (� BY: DATE: II I I BY: DATE: IL1J BY: DATE: N C� U Z_ j Z of Z LLJ N J x zw g� N z O cV 00 00 (0 z I 00 I ww Q Lo Lo z 0 z C4 LO C4 LO w Lii J > Y U (_!) SURVEYED: BCE SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. CONSTRUCTION NOTES AND DETAILS UW MEDICINE - VALLEY MEDICAL CENTER NORTH GARAGE EXPANSION 400 SOUTH 43rd STREET RENTON, WASHINGTON 98055 CK 0911JI17 AS DESIGNED: ZTW ZTW 02/24/17 AS ZTW 01/30/17 AS DRAWZTW ONE INCH ZTW 11/04/16 AS CHECKED: AS AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE APPR APPRAOSVED: b 0 I c2 Z) 0 W D- DATE: 03/13/2019 rn HELDBOOK: 0 PAGE: 0 Z DRAWING NO: M O W m SHEET: OF: CIS 24 R- 393711