HomeMy WebLinkAboutzR-406707MATCH -LINE IR 1 _ II II I I Fill 11110 1 ��• 00 10111 'a I III IIIIli ��' o 9 8.50 ������ I , u Ilk i 8 13.9 -�_ 0 1 IIIIIIIIIIIIIIII ���� o ¢aVt119atipn OP 0 20 40 60 feet U i� r'=z0' NORTH CID D z q o 4 s,1jaN Assoc xP THOMAS TANG 58178 VALVE SCHEDULE IRRIGATION SCHEDULE z NUMBER MODEL SIZE TYPE GPM WIRE PSI PSI a POC PRECIP SYMBOL MANUFACTURERIMODEL/DESCRIPTION SYMBOL MANUFACTURER/MODEVDESCRIPTION Z Z 1 Hunter ICV-G 1" Turf Spray 4.13 1,006 32.54 40.68 3.40l1 Hunter II w g 2 Hunter ICV-G 1" Turf Spray 3.44 973.9 32.35 40.42 1.711n1h Hunter PROS-06-PRS30 8' radius a 1'l 1 e Co lig and 3" Plastic Electric Remote Control Valves, 3 Hunter ICZ-101-40-LF (2) V Area for Dripline 10.7 736.E 35.45 50.73 0.43 infin o T " r Turf Spray, is psi regulated 6.0" POPUp. Co -molded wiper seal Glebe Confi urefioo, with NPT Threaded InletlOutlei for U bu 4 Hunter ICZ-101-40-LF (2) 1" Area for Dripline 10.]3 731.5 39.56 50.73 0.43 loth with UV Resistant Material. 9 w � e Commercial/Municipal Use. n/ a 5 Hunter lCZ-10140-LF (2) 1" Area for Dripline 10.88 477.5 38.32 51.27 0.43 inRi L.1_ 6 Hunter ICZ-101-40-LF(2) 1" Area for Dripline 12.66 247.6 42.45 55.14 0.43loth Hunter PROS-06-PRS30 10' radius � E 7 Hunter ICZ-101-40-LF 2 1" Area for Dripline 9.93 39.6 38.61 50.65 0.43 Iroh o T H r Turf Spray, 30 si regulated 6.0" Po U Co -molded wiper seal Hunter PGV-101 G W $ o O PPP R Pe Commercial Electric Remote Controlet/Outfor Residential/Light P 8 Hunter ICZ-101-40-LF (2) 1" Area for Dripline 13.91 518.4 43.34 56.89 0.43 inPo with UV Resistant Material. Commercial Use. Female NPT Inlet/Outlet. Globe 9 Hunter ICV-G 1" Turf Spray 8.50 718.9 33.42 43.69 1.47 inflPo Configuration, With Flow Control. O do w 10 Hunter ICV-G 1" Turf Rotary 15.35 797.4 ".70 58.03 0.38 inlh 0 0 U a ® 0 ®Hunter PROS-06-PRS30 adjustable arc L��y�/n1 do In a 11 Hunter ICZ-101-40-LF (2) 1" Area for Dripline 7.22 834.1 33.13 42.64 0.43loth Turf Spray, 30 psi regulated 6.0" Por-Up. Co -molded wiper seal 0 Hunter HQ-33DLRC a °n 12 Hunter ICV-G 1" Turf Spray 18.81 957.8 35.66 49.01 0.801n1h with UV Resistant Material. Quick coupler valve, yellow locking rubber cover, red brass and �J"J 0 Z w 13 Hunter ICV-G 1" Turf Spray 16.81 962.7 35.96 49.23 0.81 inPo stainless steel, with 314" NPT Inlet, 2-piece body. n/ ti v 14 Hunter lCZ-101-40-LF(2) V Area for Dripline 2.67 975.0 27.98 35.96 0.43loth � Hunter MP Corner PROS-06-PRS40-CV LL Z 15 Hunter ICV-G 1" Turf Rotary 12.36 1,048 43.86 53.81 0.37 inlh Turf Rotator, 6' pop-up with factory installed check valve, 0 Hunter HQ-94LRC T1 Hunter PGV-101G 1" Shrub Rotary 15.73 428.2 44.44 59.30 0.19loth pressure regulated to 40 psi, MP Rotator nozzle on PRS40 body. Quick coupler valve, yellow rubber lacking cover, red brass and T2 Hunter PGV-101G 1" Shrub Rotary 15.71 424.0 45.24 60.08 0.191n1h T=Turquoise adj arc 45-105. stainless steel, with 1" NPT inlet, 2-piece body. T3 Hunter PGV-101G 1" Shrub Rotary 18.90 419.9 36.91 54.43 0.15 inRi T4 Hunter PGV-101G 1" Shrub Rotary 15.65 180.5 44.59 59 0.19l1 Q Hunter MP1000 PROS-06-PRS40-CV � Hunter ICV-G V T5 Hunter PGV-101G 1" Shrub Rotary 15.81 177.5 45.40 59.91 0.19 in/h Turf Rotator, 6' pop-up with check valve, pressure regulated to 1", 1-1/2", 2", and 3" Plastic Electric Master Valve, Globe T6 Hunter PGV-101G 1" Shrub Rotary 15.75 173.1 34.58 49.03 0.15 loth 40 psi, MP Rotator nozzle on PRS40 body. M=Maroon adj arc Configuration, with NPT Threaded InleVOutlet, for Common Wire 2,097 90 to 210. L=Light Blue 210 to 270 arc, O=Olive 360 arc. Commercial/Munidpal Use. OOO Hunter MP2000 PROS-06-PRS40-CV gF Zum 950XLT 1' Turf Rotator, 6' pop-up with factory installed check valve, Double Check Valve Assembly pressure regulated to 40 psi, MP Rotator nozzle on PRS40 body. K=Black adj arc 90-210, G=Green adj arc 210-270, R=Red 360 NOTES am CHunteModel rC Controller, Modular Controller, 24 stations, Outdoor Model, Plastic Cabinet 1. THIS PLAN IS DIAGRAMMATIC ONLY. VERIFY ALL DIMENSIONS AND ELEVATIONS INFIELD. ADJUST Commercial Use. With three ICM-600 modules included. AI EQUIPMENT LAYOUT TO SUIT FIELD CONDITIONS AND SITE CONSTRNTS. Hunter MP3000fixedriser 2. EQUIPMENT SHOWN IN PAVED AREAS OR OUTSIDE PROJECT LIMITS IS FOR GRAPHIC CLARITY ONLY. Simon Rotator, fixed -riser, B=Blue atlj arc 90-210. Y=Yellow atlj ® Hunter WR-CLIK Q arc 210-270, A --Gray 360 arc Rain Sensor, install within 1000 ft of controller, in line of sight INSTALL IN LANDSCAPED AREA. DO NOT WILLFULLY INSTALL EQUIPMENT UNDER PAVEMENT OR 9 t. Q OUTSIDE PROJECT LIMITS. 7 Hunter MP3500 fixed riser 22-28 VACNDC 100 mA power from timer transformer. Mount 3. DALL ESIGNSLEEVES ASSUMPTIONS 20 SS OTHERWISE INDICATED. as noted. 4. DESIGN ASSUMPTIONS 20 GPM AT RADIUS PSI STATIC PRESSURE AT THE METER. VERIFY D FIELD. Shrub Rotator, fixed -riser. MP Rotator nozzle. LB=Light Brown, 5. ADJUST SPRINKLER ARC AND RADIUS AS NEEDED TO AVOID OVER SPRAY ONTO HARD SURFACES, Adjustable Arc, 90-210 O Water Meter 1" WHILE MAINTAINING PLANT COVERAGE. / 6. THIS SYSTEM QUALIFIES FOR HUNTER IRRIGATION'S ENHANCED S YEAR WARRANTY. CONTACT DANIEL SYMBOL MANUFACTURERIMODEL/DESCRIPTION Irrigation Lateral Line: PVC Class 200 SDR 21 Q MOTYLEWSKI AT 503-50"909 FOR DETAILS. Hunter ICZ-101-00-LF Irrigation Lateral Line: PVC Schedule 40 8 Drip Control Zone Kit. 1"ICV Globe Valve with 1"HY100 filter Temporary irrigation, alcove -ground system. Pressure Regulation: 40psi. Flow Range: .5 GPM to 15 Irrigation Mainline: PVC Schedule 40 O GPM. 150 mesh stainless steel screen. Pipe Sleeve: PVC Schedule 40 Q Hunter PLD-BV- Hunter PLD-BV-1/2' manual gush valve, barbed insert. Install in V r rUlow 10' box, with adequate blank or "cobra" tubing to extend valve verve N°'"bPr out of valve box. # # valve "mv 1 ' 1 #'• verve sne I 1 1 ID Hunter ECO-ID ECO-I D: 7/2" FPT connection with 12-60 PSI operating pressure. 7� Specify with Hunter SJ swing joint. ( 1 , Area to Receive Dripline / v Hunter H 2-CV: 1 2-CV Hunter HDL-04-12-CV: Hunter Dripline w/0.4 GPH emitters at 12" O.C. \ 1\ Check valve, dark brown tubing with tan striping. Dripline laterals spaced all apart, with emitters offset for triangular Pwhere possible. Install with Hunter PLO barbed or PUD-LLD-LQQ filings. '"'DESIGN IS BASED ON HUNTER. DUE TO CURRENT INVENTORIES NOTED ON THE PRODUCT DATA OF LIKE/EQUAL PRODUCTS MAY NEED TO BE SWITCHED TO RAINBIRD"' I � I