Loading...
HomeMy WebLinkAboutzS-4067SetPERMIT# O ? STA: 4+00 e CL NORTHING: 167211.8065 �j FASTING 1297770.0685 ?� -- AD II II T I Ii i ` I � II ❑s I II � � I � �l s cr of w I I rZo 1 3 I Jo I \ 3 yak \ I $$TA: 2+50 Oaj R . 6%61.8514 5.2 STIN�i' 9k6648 I -/I EXISTING 6" CONCRETE SIDE SEWER SERVICE CONTRACTOR TO VERIFY CONDITION OF PIPE PRIOR TO CONNECTION 52 LF 6" PVC SDR 35 Q 1.67 / SSCO #5 STA: 3+46.78, 76.18 RT I ,OZ' I I $ 191 LF 6" PVC SDR 35 S la' SfiArS�4}52Pr33-P6-RR•F AiSA6N6F" I_.�I <O atl VERTICAL DATUM NOVEL 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. VERIFIED CITY OF RENTON 230 -.a (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) - ELEV: 230.75 VERIFY INVERT DEPTH PRIOR TO ORDERING MATERIALS. NOTIFY ENGINEER IF DEPTH IS HIGHER THAN SHOWN F 4 LP 6" PVC SDR 35 @2. % S S -F fSHUT-OFF VALVE I S RIM: 22.14 22.34 STA: 3+44.12, 229.00 RT IE: 16.70 6" (N) - - - FINISHED FLOOR: 22.70 SSCO#1­L1 RIM:44GF22.50 CONTINUATION TO STA: 3+39.07, 284.25 RT IE'i769-6' 1B 1763 OIL/WATER SEPARATOR e U r SSCO #3 / STA: 3+51.21, 279.95 RT SSCO #2 STA: 3+51.34. 284.72 RT CONTINUATION TO CAR WASH BATHROOM SERVICE O r CAR SERVICE I .I d J BASIS OF BEARING NAD 1983 WASHINGTON STATE PLANE NORTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) -10 LF 6" PVC SDR 35 @ 2.00% CONTINUATION Il TO CAR SERVICE AREA f CAR WI AREA SANITARY SEWER NOTES 1. SEWER SERVICE SHALL BE 6" PVC SDR 35. 2. PROVIDE SEWER CLEANOUTS PER DETAIL 1 C3.2 3. PROVIDE SEWER PIPE BEDDING PER DETAIL 2 C3.2 0+50 1+00 1+50 2+00 2+50 3+00 SEWER PROFILE 0 Know what's below. Call before you 25 20 15 10 DATUM O SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE. ANBL IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT PS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT PRE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FORANYPURPOSE BF ML DMI ML LH:��Bt SK �� U"EC01OMXY 140. REVISION BY DATE APPR Mwa•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lanning/Building/Public Works Dept. / �!G/A�C✓ TACO MA • S EATTL E �oa, ad}�°8B®� S PO KAN E • TRI-CITIES �%0NA6 $1 2215 North 30th Street, Suite 300 Tacoma, WA 98403 psX/y/zp1/ 253.383.2422 TEL 253.383.2572 FM w Lahbl.mm WEB IN COMPLIANCE WITH CITY OF RENTON STANDARDS WALKER MAZDA DEALERSHIP AS-BUILTS AHBL JOB #2180100.11 SEWER PLAN AND PROFILE C3.1 7 O N N O O T u LIE) O co O O O 00 Q J N C) O O O 00 To 7 S-406701