HomeMy WebLinkAboutW_Bosair_Hangar_Demolition_210914_v1.pdf
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
1
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
SA SUBMITTAL REQUIREMENTS
SITE PLAN REVIEW
Planning Division
1055 South Grady Way, Renton, WA 98057
Phone: 425-430-7294 | www.rentonwa.gov
PURPOSE: To assure the site plan is compatible with both the physical characteristics of the site and the
existing and potential uses of the surrounding area. In addition, Site Plan Review assures the
development is consistent with City of Renton plans, policies and regulations.
FREE CONSULTATION MEETING: Prior to submitting an application, the applicant should informally
discuss the proposed development with the Planning Division. The Planning Division will provide
assistance and detailed information on the City’s requirements and standards. Applicants may also take
this opportunity to request the waiver of the City’s typical application submittal requirements, which
may not be applicable to the specific proposal. For further information on this meeting, see the
instruction sheet entitled “Submittal Requirements: Pre-Application.”
APPLICATION SCREENING: Applicants are required to bring in a CD or USB portable (flash/hard) drive
(or other device or pathway as approved by your assigned project manager) with one PDF file of the
application package for informal review by staff, prior to scheduling an intake meeting. Please allow
approximately 45 minutes for application screening.
COMPLETE APPLICATION REQUIRED: In order to accept your application, each of the numbered items
must be submitted at the same time. If you have received a prior written waiver of a submittal item(s)
during a pre-application meeting, please provide the waiver form in lieu of any submittal item not
provided.
APPLICATION SUBMITTAL HOURS: Applications should be submitted to Development Services staff at
the 6th floor counter of Renton City Hall, 1055 South Grady Way, between 8:00 a.m. and 4:00 p.m.
Monday through Friday. Please call your assigned project manager to schedule an appointment or call
425-430-7294 to reach the Planning Division. Due to the screening time required, applications delivered
by messenger cannot be accepted.
ADDITIONAL PERMITS: Additional permits from other agencies may be required. It is the applicant’s
responsibility to obtain these other approvals. Information regarding these oth er requirements may be
found at http://apps.oria.wa.gov/opas/.
All Plans and Attachments are subject to Electronic File Standards
Prepared by AEM
on 08/26/2021
2
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
APPLICATION MATERIALS:
1. Pre-Application Meeting Summary: If the application was reviewed at a “pre-application
meeting,” please provide the written summary provided to you.
2. Waiver Form: If you received a waiver form during or after a “pre-application meeting,”
please provide this form.
3. Land Use Permit Master Application Form: Application must have notarized signatures of
ALL current property owners listed on the Title Report. If the property owner is a
corporation, the authorized representative must attach proof of signing authority on behalf
of the corporation. The legal description of the property must be attached to the application
form.
4. Fees: The application must be accompanied by the required application fee (see Fee
Schedule). Please call 425-430-7294 to verify the exact amount required. Checks should be
made out to the City of Renton and cannot be accepted for over the total fee amount. Credit
cards may also be used to pay required application fees. Fees are paid at Cashier on the 1st
Floor City Hall.
5. Project Narrative: Please provide a clear and concise description of the proposed project,
including the following:
Project name, size and location of site;
Land use permits required for proposed project;
Zoning designation of the site and adjacent properties;
Current use of the site and any existing improvements;
Special site features (i.e. wetlands, water bodies, steep slopes);
Statement addressing soil type and drainage conditions;
Proposed use of the property and scope of the proposed development;
For plats indicate the proposed number, net density and range of sizes (net lot area)
of the new lots;
Access;
Proposed off-site improvements (i.e. installation of sidewalks, fire hydrants, sewer
main, etc.);
Total estimated construction cost and estimated fair market value of the proposed
project;
Estimated quantities and type of materials involved if any fill or excavation is
proposed;
Number, type and size of any trees to be removed;
Explanation of any land to be dedicated to the City;
Any proposed job shacks, sales trailers, and/or model homes; and
Any proposed modifications being requested (include written justification).
For projects located within 100 feet of a stream or wetland, please include:
Distance in feet from the wetland or stream to the nearest area of work.
W = Waived
W
X
X
X
3
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
For projects located within 200-feet of Black River, Cedar River, Springbrook Creek, May
Creek and Lake Washington please include the following additional information:
Distance from closest area of work to the ordinary high water mark ;
Description of the nature of the existing shoreline; and
The approximate location of and number of residential units, existing and potential,
that will have an obstructed view in the event the proposed project exceeds a height
of 35-feet above the average grade level.
6. Environmental Checklist: Please ensure you have signed the checklist and that all questions
on the checklist have been completed. If a particular question on the checklist does not
apply, fill in the space with “Not Applicable.”
7. Rezone, Variance, Modification, or Conditional Use Just ification: Please contact the
Planning Division to determine whether your project proposal triggers any additional land
use permits. If so, additional information may be required.
8. Density Worksheet
9. Plat Certificate or Title Report: Please provide a current Plat Certificate or Title Report
obtained from a title company documenting ownership and listing all encumbrances of the
involved parcel(s). The Title Report should include all parcels being developed, bu t no
parcels that are not part of the development. If the Plat Certificate or Title Report references
any recorded documents (i.e. easements, dedications, covenants), the referenced recorded
document(s) must also be provided. All easements referenced in the Plat Certificate must be
located, identified by type and recording number, and dimensioned on the Site Plan.
10. Draft Legal Documents: Please provide any proposed street dedications, restrictive
covenants, draft Homeowners Association, or any other legal documents pertaining to the
development and use of the property.
11. Construction Mitigation Description: Please provide a written narrative addressing each of
the following:
Proposed construction dates (begin and end dates);
Hours and days of operation;
Proposed hauling/transportation routes;
Measures to be implemented to minimize dust, traffic and transportation impacts,
erosion, mud, noise, and other noxious characteristics;
Any special hours proposed for construction or hauling (i.e. weekends, late nights);
and
Preliminary traffic control plan.
If your project requires the use of cranes, please contact the City’s Airport Manager at 425-
430-7471 to determine whether Federal Aviation Administration (FAA) notification will be
required.
12. Urban Center Design Overlay District Report: For any projects in an Urban Design District,
W
W
W
W
W
X
X
4
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
please provide a statement addressing how the project meets the requirements of the
Urban Center Design Overlay District. The statement shall address the following:
Pedestrian building entries
Transition to surrounding development
Location of parking, design of surface parking, and/or structure/garage parking
Vehicular access
Pedestrian circulation
Common space
Landscaping
Building character and massing, rooflines, and materials
13. Affidavit of Installation of Public Information Sign(s): Please complete and provide the
attached notarized affidavit attesting the required public information sign(s) has been
installed in accordance with City Code requirements. See attachment titled “Public
Information Signs” for information about the size and location requirements for public
information signs.
14. Neighborhood Detail Map: Please provide a map drawn at a scale of 1" = 100' or 1" = 200'
(or other scale approved by the Planning Division) to be used to identify the site location on
public notices and to review compatibility with surrounding land uses. The map shall identify
the subject site with a much darker perimeter line than surrounding properties and include
at least two cross streets in all directions showing the location of the subject site relative to
property boundaries of surrounding parcels. The map shall also show: the proper ty's lot
lines, lot lines of surrounding properties, boundaries of the City of Renton (if applicable),
north arrow (oriented to the top of the plan sheet), graphic scale used for the map, and City
of Renton (not King County) street names for all streets shown. Please ensure all information
fits on a single map sheet.
Kroll Map Company (206-448-6277) produces maps that may serve this purpose or you may
use the King County Assessor’s maps as a base for the Neighborhood Detail Map. Additional
information (i.e. current city street names) will need to be added by the applicant.
15. Affidavit of Installation of Public Outreach Sign(s): Please complete and provide the
attached notarized affidavit attesting the required public outreach sign(s) has been installed
in accordance with the City Code requirements. See attachment titled “Public Outreach
Signs” for information about the size and location requirements for public outreach signs.
16. Proof of Neighborhood Meeting: Please provide the following materials with the submittal
of a complete development application:
The notice provided to surrounding property owners within three hundred feet
(300’) of the proposed development site;
The mailing list used to send out meeting not ices;
An affidavit of mailing and posting notice(s);
The meeting sign-in sheet;
Materials presented at the meeting;
W
W
W
W
5
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
Notes of the meeting including a summary of oral and written comments received;
and
If no members of the public attended the neighborhood me eting and/or persons in
attendance made no comments, the required submittal materials shall reflect the
absence of comment, attendance, or both.
17. Overall Site Plan (Only for previously appr oved Master Site Plans): Please provide an
overall site plan if the project has previously undergone a Master Site Plan Review. The
overall site plan should detail how this specific phase of the project fits in relation to the
previously approved master site plan.
18. Site Plan: Please provide a fully-dimensioned plan sheet drawn at a scale of 1"=20' (or other
scale approved by the Planning Division). We prefer the site plan be drawn on one sheet of
paper unless the size of the site requires several plan sheets to be used. If you are using
more than a single plan sheet, please indicate connecting points on each sheet.
The Site Plan should show the following:
Name of proposed project;
Date, scale, and north arrow (oriented to the top of the paper/plan sheet);
Drawing of the subject property with all property lines dimensioned and names of
adjacent streets;
Widths of all adjacent streets and alleys;
Location of all existing public improvements including, but not limited to, curbs,
gutters, sidewalks, median islands, street trees, fire hydrants, utility poles, etc., along
the full property frontage;
Location and dimensions of existing and proposed:
1. structures
2. parking, off-street loading space, curb cuts and aisle ways
3. fencing and retaining walls
4. free-standing signs and lighting fixtures
5. refuse and recycling areas
6. utility junction boxes and public utility transformers
7. storage areas and job shacks/sales trailers/model homes
Setbacks of all proposed buildings from property lines;
Location and dimensions of all easements referenced in the title report with the
recording number and type of easement (e.g. access, sewer, etc.) indicated;
Location and dimensions of natural features such as streams, lakes, required buffer
areas, open spaces, and wetlands; and
Ordinary high water mark and distance to closest area of work for any project
located within 200-feet from a lake or stream.
19. Architectural Elevations: Please provide for each building and each building face (N, S, E, &
W) a 24” x 36” fully-dimensioned architectural elevation plan drawn at a scale of 1/4” = 1’ or
1/8” = 1’ (or other size or scale approved by the Planning Division). The plans must clearly
indicate the information required by the “Permits” section of the currently adopted
International Building Code (IBC) and RCW 19.27 (State Building Code Act, Statewide
W
W
X
6
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
amendments), including, but not limited to the following:
Identify building elevations by street name (when applicable) and orientation i.e.
Burnett Ave. (west) elevation;
Existing and proposed ground elevations;
Existing average grade level underneath proposed structure;
Height of existing and proposed structures showing finished roof top elevations
based upon site elevations for proposed structures and any existing/abutting
structures;
Building materials and colors including roof, walls, any wireless communication
facilities, and enclosures;
Fence or retaining wall materials, colors, and architectural design ;
Architectural design of on-site lighting fixtures;
Screening detail showing heights, elevations, and building materials of proposed
screening and/or proposed landscaping for refuse/recycling areas; and
Cross section of roof showing location and height of roof-top equipment (include air
conditioners, compressors, etc.) and proposed screening.
20. Landscape Plan, Conceptual: Please provide a fully-dimensioned plan drawn by a licensed
Landscape Architect at the same scale as the project site plan (or other scale approved by
the Planning Division), clearly indicating the following:
Date, graphic scale, and north arrow;
Location of proposed buildings, parking areas and access, and existing buildings to
remain;
Names and locations of abutting streets and public improvements, including
easements;
Existing and proposed contours at two-foot intervals or less;
Location and size of planting areas;
Location and height of proposed building;
Location and elevations for any proposed landscape-related structures such as
arbors, gazebos, fencing, etc.;
Location, size, spacing and names of existing (to remain) and proposed shrubs, trees,
and ground covers. Locations of decorative rocks or landscape improvements in
relationship to proposed and existing utilities and structures; and
For wireless communication facilities, indicate type and locations of existing and new
plant materials used to screen facility components and the proposed color(s) for the
facility.
21. Landscape analysis, lot coverage, and parking analysis: Please provide a landscape and
parking analysis including:
Total square footage of the site and the footprints of all buildings ;
Total square footage of existing and proposed impervious surface area(s) ;
Square footage (by floor and overall total) of each individual building and/or use ;
Percentage of lot covered by buildings or structures;
Number of parking spaces required by City code;
W
W
7
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
Number and dimensions of standard, compact, and ADA accessible spaces provided ;
and
Square footage of parking lot landscaping (perimeter and interior).
22. Floor Plans: Please provide a plan showing general building layout, proposed uses of space,
walls, exits and proposed locations of kitchens, baths, and floor drains, with sufficient detail
for City staff to determine if an oil/water separator or grease interce ptor is required and to
determine the sizing of a side sewer.
23. Topography Map: Please provide a plan showing the site’s existing contour lines at five-foot
vertical intervals and planimetric features extending ten feet beyond the property
boundaries.
24. Tree Retention/Land Clearing (Tree Inventory) Plan: Please provide a fully dimensioned
plan drawn by a certified arborist or a licensed landscape architect if ANY trees or
vegetation are to be removed or altered. The plan shall be based on finished grade, drawn at
the same scale as the project site plan with the northern property line at the top of the
paper, and clearly show the following:
All property boundaries and adjacent streets, location and dimensions of rights- of-
way, utility lines, fire hydrants, street lighting, and easements;
Location of all areas proposed to be cleared;
Location, species, and sizes of trees on or immediately abutting the site. This
requirement applies only to trees with a caliper of at least six inches (6"), or an alder
or cottonwood tree with a caliper of at least eight inches (8"), when measured at
fifty-four inches (54") above grade;
Clearly identify trees to be retained and to be removed;
Future building sites and drip lines of any trees which will overhang/ overlap a
construction line. Where the drip line of a tree overlaps an area where construction
activities will occur, this shall be indicated on the plan; and
Show critical areas and buffers.
25. Tree Retention Worksheet: Please provide a completed City of Renton tree retention
worksheet.
26. Arborist Report: Please provide an arborist report by a certified Arborist or a licensed
Landscape Architect that correlates with the Tree Retention/ Land Clearing Plan and
addresses the following:
Identification scheme used for each tree (e.g. tree number);
Species and size of each tree (caliper measured at 54 inches above grade);
Reason(s) for any tree removal (e.g. poor health, high risk of failure due to structure,
defects, unavoidable isolation (high blow down potential), unsuitability of species,
etc.) and for which no reasonable alternative action is possible (pruning, cabling,
etc.);
For trees proposed to be retained, a complete description of each tree' s health,
condition, and viability;
W
Waived if no
trees
proposed
for removal
Waived if no
trees
proposed
for removal
Waived if no
trees
proposed
for removal
W
8
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
For trees proposed to be retained, a description of the method(s)used to determine
the limits of disturbance (e.g., critical root zone, root plate diameter, or a case - by-
case basis description for individual trees);
A description of the impact of necessary tree removal to the remaining trees,
including those in a grove or on abutting properties;
The suggested location and species of supplemental trees to be used when required.
The report shall include planting and maintenance specifications; and
An analysis of retained trees according to Priority of Tree Retention Requirements
specified in RMC 4-4-130H.1.b.
27. Wetland Assessment: Please provide a map and a report if ANY wetlands are located on
the subject property or within 100 feet of the subject property. The wetland report/
delineation must be prepared by a qualified professional and include the information
specified in RMC 4-8-120D.23. In addition, if any alteration to the wetland or buffer is
proposed, a wetland mitigation plan is also required. See RMC 4-8-120D.23 for plan content
requirements.
28. Standard Stream or Lake Study: Please provide a report containing the information
specified in RMC Section 4-8-120D.19. In addition, if the project involves an unclassified
stream, a supplemental stream or lake study is also required. If any alteration to a water-
body or buffer is proposed a supplemental stream or lake study and mitigation plan are
also required.
29. Flood Hazard Data: Please provide a scaled plan showing the nature, location, dimensions,
and elevations of the area in question; existing or proposed structures, fill, storage of
materials, and drainage facilities. Also indicate the following:
Elevation in relation to mean sea level of the lowest floor (includ ing basement) of all
structures;
Elevation in relation to mean sea level to which any structure has been flood -
proofed;
Certification by a registered Professional Engineer or Architect the flood-proofing
methods criteria in RMC 4-3-050G.4.c have been met; and
Description of the extent to which a watercourse will be altered or relocated as a
result of proposed development.
30. Biological Assessment/Critical Areas Study: Please provide if the project is located in a
designated floodplain (RMC 4-8-120D.2).
31. Habitat Data Report: If the project site contains or abuts a critical habitat per RMC 4-3-
050F.2.b, please provide a report containing the information specified in RMC 4-8-120D.8.
32. Geotechnical Report: Please provide a study prepared and stamped by a State of
Washington licensed Professional Engineer including soils and slope stability analysis, boring
and test pit logs, and recommendations on slope setbacks, foundation design, retaining wall
design, material selection, and all other pertinent elements.
W
W
W
W
W
W
9
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
33. Letter of Understanding Geologic Risk: Please provide a letter from the applicant, or the
owner of the site, stating that he or she understands and accepts the risk of developing in an
unstable area and that he or she will advise, in writing, any prospective purchasers of the
site, or any prospective purchasers of structures or portions of structures on the site, of the
unstable potential of the area.
34. Utilities Plan, Generalized (sewer, water, stormwater, transportation improvements):
Please provide a plan drawn on 22" x 34" plan sheets using a graphic scale of 1" = 40' (or
other size or scale approved by the Planning Division) clearly showing all existing (to remain)
and proposed public or private improvements to be dedicated or sold to the public
including, but not limited to, curbs, gutters, sidewalks, median islands, street trees, fire
hydrants, utility poles, free-standing lighting fixtures, utility junction boxes, public utility
transformers, etc., along the full property frontage. The finished floor elevations for each
floor of proposed and existing (to remain) structures shall also be shown.
35. Drainage Control Plan: Please provide a plan drawn to scale and stamped by a Washington
State licensed Professional Engineer and complying with the requirements of RMC 4-6-030
and the 2017 City of Renton Surface Water Design Manual (RSWDM).
36. Drainage Report: Please provide a report stamped and dated by a State of Washington
licensed Professional Engineer complying with the requirements of the City of Renton
Drafting Standards, (RMC 4-6-030), and the 2017 City of Renton Surface Water Design
Manual (RSWDM). The report shall contain the following:
Table of Contents;
Technical Information Report (TIR) Worksheet;
Section 1: Project Overview;
Section 2: Conditions and Requirements Summary;
Section 3: Offsite Analysis;
Section 4: Flow Control and Water Quality Facility Analysis and Design;
Section 5: Conveyance System Analysis and Design;
Section 6: Special Reports and Studies;
Section 7: Other Permit;
Section 8: Construction Stormwater Pollution Prevention Plan (CSWPPP) Analysis
and Design;
Section 9: Bond Quantities, Facility Summaries, and Declaration of Covenant; and
Section 10: Operations and Maintenance Manual.
37. Grading Elevations and Plan, Conceptual: This is required if the proposed grade differential
on-site will exceed 24" from the top of the curb or if the amount of earth to be disturbed
exceeds 500 cubic yards. Please provide a 22" x 34" plan drawn by a State of Washington
licensed Civil Engineer or Landscape Architect at a scale of 1" to 40' (horizontal feet) and 1"
to 10' (vertical feet) (or other size plan sheet or scale (approved by the Planning Division
Plan Review Project Manager) clearly indicating the following:
Graphic scale and north arrow;
W
Show any
existing utilities
under/near the
structures
W
W
W
10
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
Dimensions of all property lines, easements, and abutting streets;
Location and dimension of all on-site structures and the location of any structures
within 15-feet of the subject property or that may be affected by the proposed work;
Accurate existing and proposed contour lines drawn at two-foot, or less, intervals
showing existing ground and details of terrain and area drainage to include
surrounding off-site contours within 100-feet of the site;
Location of natural drainage systems, including perennial and intermittent streams
and the presence of bordering vegetation;
Setback areas and any areas not to be disturbed;
Finished contours drawn at two -foot intervals as a result of grading;
Proposed drainage channels and related construction with associated underground
storm lines sized and connections shown;
Finished floor elevation(s) of all structures, existing and proposed;
General notes addressing the following (may be listed on cover sheet):
Area in square feet of the entire property;
Area of work in square feet;
Both the number of tons and cubic yards of soil to be added, removed, or relocated;
and
Type and location of fill origin, and destination of any soil to be removed from site.
38. Screening Detail, Refuse/Recycling: Please provide a detailed plan drawing, prepared to
scale, showing location within property boundaries, heights, elevations, and building
materials of proposed screening or of proposed plantings.
39. Traffic Study: Please provide a report prepared by a State of Washington licensed
Professional Engineer containing the elements and information identified in the City of
Renton “Policy Guidelines for Traffic Impact Analysis of New Development” in sufficient
detail to define potential problems related to the proposed development and identify the
improvements necessary to accommodate the development in a safe and efficient manner.
40. Colored Maps for Display: Please provide a colored version of each plan sheet for use in
presenting the project to the Environmental Review Committee and at any required public
hearing:
Neighborhood Detail Map
Site Plan
Landscaping Plan
Elevations
The following colors are required:
Red-North Arrow, outer property boundary. Proposed new lot lines (dashed). Do not
color existing lot lines which are to be eliminated or relocated.
Blue-Street names identified with lettering of at least 1” in height. Street names must be
legible at a distance of 15-ft.
Brown-Existing buildings (please do not color buildings which will be demolished or
W
W
W
11
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
removed)
Yellow-Proposed buildings
Light Green-Landscaped areas
Dark Green-Areas of undisturbed vegetation
All Plans and Attachments are subject to Electronic File Standards
REVIEW PROCESS: Once a complete land use application package has been accepted for initial review,
the Planning Division will post one notice of the pending application at or near the subject site and mail
notices to property owners within 300 feet of the project site. The proposal will be routed to other City
departments and other jurisdictions or agencies that may have an interest in the application. The
reviewers have two (2) weeks to return their comments to the Planning Division. Within approximately
two weeks, the Planning Division will prepare a report regarding the proposal’s compliance with
applicable codes and the City’s review criteria.
The application will then be presented to the City’s Environmental Review Committee. The
Environmental Review Committee (ERC) is comprised of the Administrator of Public Works, the
Administrator of Community and Economic Development, the Administrator of Community Services, and
the Fire Chief. The Committee is responsible for determining whether the proposal will result in
significant adverse environmental impacts. To do this, the committee will consider such issues as
environmental health hazards, wetlands, groundwater, energy and natural resources and will then issue
its decision (Environmental Threshold Determination).
The Environmental Review Committee will either issue a:
Determination of Non-Significance (DNS)-Make a determination the proposal will have no
significant negative environmental impacts; or
Mitigated Determination of Non-Significance (DNS-M)-Make a determination the proposal,
if modified, would have no significant negative environmental impacts; or
Determination of Significance (DS)-Make a determination the proposal will have significant
adverse environmental impacts and require the applicant to submit an Environmental Impact
Statement (EIS) prepared by a qualified consultant.
Once the Environmental Review Committee has issued its Environmental Threshold Determination
(provided an EIS is not required), a public notice of the Determination is printed in the Renton Reporter
and notice(s) are posted at or near the site. A 14-day appeal period commences following the
publication date. At the discretion of the City, a separate and additional 15-day comment period may be
added prior to the 14-day appeal period. The remainder of the review process differs depending on
whether a public hearing is required. Section 4-2-060 of the Renton Municipal Code stipulates whether
or not a public hearing is required.
In addition to issuing the Environmental Determination, the Environmental Review Committee is also
charged with determining whether a public hearing should be required for those Site Plan proposals not
automatically triggering a public hearing. The Environmental Review Committee will consider the
12
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
departmental and public comments in determining whether or not a hearing should be required. This
determination may be appealed within 14 days to the Hearing Examiner pursuant to RMC 4-8-110.
Projects exceeding the size limits listed in the RMC 4-9-200D.3 and projects abutting or across the street
from residential zones MUST have a public hearing. No variance from this requirement is possible. The
remainder of the review process differs depending on whether a public hearing is required.
Administrative Site Plan Review: A public hearing is not required. The Planning Division reviews
the proposal for compliance with the requirements of RMC 4-9-200E, F in conjunction with the
Environmental Review Committee decision and any staff or public comments prior to making a
decision. The decision to approve, conditionally approve, or deny the proposal will be mailed to
all persons listed on the Master Application and all parties of record.
Hearing Examiner Site Plan Review and Review of Environmental Determination Appeals: A
public hearing is required. After review of the proposal and any staff or public comments, the
Planning Division staff will forward a report and recommendation and the Environmental Review
Committee decision to the Hearing Examiner prior to the hearing. This report will be mailed to all
persons listed on the Master Application and all parties of record. Notice of the public hearing
will be published in the Renton Reporter at least 10 days prior to the hearing, the site will be
posted again, and parties of record will receive notices of the hearing via mail. Applicants are
strongly encouraged to attend the public hearing for th eir proposal. City staff will first make a
presentation to the Hearing Examiner about the proposal. Either the applicant or citizens in
support of the proposal will then give testimony. When giving testimony, names and addresses
must be stated for the record. Following this, individuals with neutral or opposing comments will
give their testimony to the Hearing Examiner. City staff or the applicant will address additional
questions raised throughout the hearing. The Hearing Examiner will review the proposed
application for compliance with the requirements of RMC 4-9-200E and F concurrently with any
environmental appeals and issue a final decision(s) within 14 days of the hearing unless, at the
time of the public hearing, the Hearing Examiner indicates additional time will be required for
issuance of the decision. The decision to approve, conditionally approve, or deny the proposal
will be mailed to all persons listed on the Master Application and all parties of record. The
Examiner’s decision on any environmental appeals will also be mailed.
APPEAL AND RECONSIDERATION PROCESS FOR DECISIONS: Any person, including the applicant,
aggrieved by the granting or denial of an application, may make a written application for reconsideration
to the Reviewing Official within 14 calendar days of the date of the decision. After review of the request,
the Reviewing Official may take whatever action is deemed prope r. The Reviewing Official’s written
decision on the reconsideration request will be mailed to all parties of record within 10 days from the
date the request was filed. If any party is still not satisfied after a reconsideration decision has been
issued, an appeal may be submitted within 14 days to:
The Hearing Examiner for Administrative decisions
The City Council for Hearing Examiner decisions
An appeal may be filed without first requesting reconsideration by the Reviewing Official; however, it
must be filed within 14 days of the date when the original decision was issued. See RMC 4-8-110 for
further information on the appeal process and time frames.
13
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\sa.doc Rev: 02/2017
BUILDING AND CONSTRUCTION PERMIT ISSUANCE AND INSTALLATION OF IMPROVEMENTS: In the
City of Renton, a Building Permit must be obtained to build buildings and structures. A Construction
Permit must be obtained to install utility lines, transportation improvements and undertake work in City
right-of-ways. Building and Construction Permits are separate permits.
Applicants may apply for building and construction permits concurrently with their request for a land
use application. However, the applicant should be aware any conditions of land use permit approval may
create a need for revisions to other permit applications whereby additional fees may be charged.
Refunds of building permit charges are not available.
If no appeals or reconsideration requests are filed within 14 days of the effective date of the decision to
approve the application, the applicant may obtain building and construction permits. A construction
permit for the installation of on-site and off-site utilities will be issued upon the review and approval of
civil engineering drawings by the Division’s Public Works Section and receipt of all applicable
development and permit fees. A building permit will be issued upon the Building Section’s approval of
building plans and receipt of all applicable fees.
DEFERRAL OF IMPROVEMENTS: If a developer wishes to defer certain on-site or off-site improvements
(i.e. landscaping, curbs and sidewalks), written application with full and complete engineering drawings
must be submitted to the Development Engineering Section. The application should explain the reasons
why such delay is necessary. If approval is granted, security in the form of an irrevocable letter of credit,
set-aside fund, assignment of funds, or certified check shall be furnished to the City in an amount equal
to a minimum of 150% of the estimated cost of the required improvements.
EXPIRATION AND EXTENSIONS: Once an application has been approved, the applicant has two years to
comply with all conditions of approval and to apply for an y necessary permits before the approval
becomes null and void. The approval body that approved the original application may grant a single two -
year extension. The approval body may require a public hearing for such extension.