HomeMy WebLinkAboutR-418909rn
00
T
C)
1
n
7
2
3
4
j
6CYCLONE FENCE
OLLARDs ��------------------�
/ ZONE 13 \
I/-------------------------------------------------------------------------------------------- \
Ii ----- ---- ----
_T-Yf1r------------------------------ILL- \\\ RM DRAIN.
---
- ---- ---- -
I I B.0 .D- 9.D -8,0 9. _ IA�GA4
- - -------------- _ .
OF SE n
_ DI �
1-1 SD SO SO 1 =�2' 1-1 2" CATCOOBASI1
AIMPVC E a 2 BE
1-I 2
n I 45.00' 2" 2" ZONES
¢ --------------- _ -- ------ - ----- --- ---- ----- s.o------- 9.0 9.0 s.o s.o duo 1
I I I
I 1 9.0 1 \----%----/ I/ ------ -- -----------
I I 1 I 1
PIPE TRENCH NO
I 2_ IN 1
> ix.
SMS-2
1 of Cl SOIL MOISTURE 5 P3
B I h / qq5 SENSOR
I0 / 1-1 2"
I I° OI 1- 2" 2" ZONE N�0P5 1
N--- --- -- ------I 1
- a5.0 0' /-s -- -- -- --s.o 90 s.o s. IN
I z
II s.o Nbi1zlo _ --_-------_-1 45.00' �Nj1 2" 4s.00 (TYP•)4 2 e 2 1/2" 1 A
SITE ENCHM K
pA _3 E�STS G.'RTH L� 939075
L MO TORE 2
SO ELEVA ION: 45. ET
_ -----_ ZO 6 -_-__- 2. r
9.0 T' 9.0 9.0 .o - I
9.0
1-1 2" I ,-1/2'• 2" 2 2 1_1 2• 2 L
ROTOR RISER 3 1z
2-1/2-
3
I ItD,
ASSEMBLY F 2.4 �
/ O
L
% 1-1/2" 2" w ZONE4 1 1 2" 1""IM 9asiry
1 3" MAINLINE ------------------------------ ------ PVC ME4443. ocv-z4QUICK COUPLING� /
F-2.4 VALVE m 1 \\�� �;
13 I1 / / / \ \ �ONF \ o 44
45.00' (TYP.) Vi
RE OTE CONTROIF 1 / / l` ^52.18• \ •� \ e I tx•9
VALV IN INDNIDUAL / 1 .o / / \ x, \\ 1-1/2" \ 1_1/2" 1
1 VALVE BOX II \\\ 2 2 ZONES
-- ---------- ----- ---
s.o 9.0 -
F-2.5 13 1 11 / \\ :` ( w 9.o1-
2" 9.3
3" MAINLINE 1 SMS-1
•o \ I 1 SOIL MOISTURE ROTOR RISER 3 1
SENSOR ASSEMBLY F_2.4
112
O 9 I / II 2-1/2` 1
m
1 0 1 I ZONE2
/-12.0 1za�----------1z.o --------Iz.o \
2-1/2" m
I.
9S I \11s 11 / 1-1//
45.56' TYP.
6.� I "+ 1I \\ / I 1-1/2" 2" ZONE I 7-1 /9• / -- _
--- -- f� ---
_ _ - - F
9.o a.o s.o _ s.D ����DOUBLE CHECK VALVEF- .] h \ -:AL
oI
\\ �--- ZONE 13
\ / I 121116 9 8 7 6 5 4,
�. BV-4 ------ -- - -- - -
2.3 BALL VALVE 3" MAINLINE -- -- OCV-1 BV 3
QUICK COUPLING BALL VALVE
VALVE _
4 REMOTE CON
oq2�F-2.4 VALVE MANIF
A�4'f
\ 12
n50/ z• s.z 11 z ��
/
rT---------
ry�
1 PORTABLE
z^53.7 z"31.s
IRRIGATION MAINLINE.
E N7Ha00NNECT NEW 3"
' IRRIGON MAINLINE
FIELD LOCATE EXISTING
IRRIGATION CONTROL WIRES.
UTILIZE EXISTING IRRIGATION
1 i CONTROL WIRES FOR NEW
2,. 6 _� TWO -WIRE COMMUNICATION PATH
AND MOISTURE SENSORS.
LIGHT STANOA
REVISION DATE
IRRIGATION NOTES
1. COORDINATE QUICK COUPLING VALVE LOCATIONS TO CORRESPOND TO
THE EDGE OF THE FIELD-
2. THE CONTRACTOR SHALL LOCATE EXISTING ELECTRICAL AND
COMMUNICATION CONDUCTORS IN THE FIELD AND VERIFY TO DEPTH
WITH THE ENGINEER PRIOR TO TRENCHING FOR THE DRAINAGE AND
WATER SYSTEMS-
3. COORDINATE IRRIGATION PIPING TO AVOID UNDERGROUND UTILITIES.
MarvHOLE 4. SPRINKLER HEADS IN THE NATURAL TURF AREAS SHALL BE SET FLUSH e n t o n
WITH FINISH GRADE. NO SETTLEMENT AROUND THE SPRINKLER HEADS
SHALL BE TOLERATED.
's SCHOOL DISTRICT
.5. ROTARY SPRINKLER HEADS TO BE LOCATED 6 INCHES MAXIMUM AND 3
- SO
INCHES MINIMUM FROM THE EDGE OF PAVING CONCRETE, ASPHALT OR
RVRBER MAT
CURBING) IN THE NATURAL TURF.
6. ALL IRRIGATION MAINLINES, LATERAL LINES, ELECTRICAL AND VALVE
CONTRj� SD Pv SHALLOBE WI
LLEEVED.RES OSSING SLEEVESDER SHALL BEAPLACED AND
UNDERASPHALT DRIVEWAYS
ALL
DRIVEWAYS, PAVED AREAS. WALKS AISLES, ETC WHERE IRRIGATION SIERRA HEIGHTS
! LAre ouq LATERAL. MAINLINE AND CONTROL WIRES CROSS. SLEEVES SHALL BE
I E9uTPRENS. - PVC SCH 40. BURY MINIMUM 24• DEEP. MINIMUM DISTANCE PAST ELEMENTARY
EDGE OF PAVED SURFACE SHALL BE 24•. WATER AND WIRE SHALL
.I NOT BE PLACED IN THE SAME SLEEVE. SLEEVES SHALL BE TWICE THE p LAY F I E LD
DIAMETER OF THE PIPE BEING SLEEVED. WIRE SLEEVES TO
BE 2'. SLEEVES ARE REQUIRED, WHETHER OR NOT INDICATED IN PLAN.
I FIELD LOCATE THE EXISTING IRRIGATION CONTROL WIRES. USE THE RENOVATIONS
EXISTING CONTROL WIRES FOR THE NEW TWO -WIRE COMMUNICATION
PATH TO THE NEW IRRIGATION VALVES AND SOIL MOISTURE SENSORS.
" 8. ALL IRRIGATION REMOTE CONTROL VALVES SHALL BE 2" UNLESS
OTHERWISE NOTED.
I -- 9. POP UP RISER HEIGHT IN SEEDED /TURF AREAS TO BE 4".
I a
I - -10. IRRIGATION SYSTEM LAYOUT: DUE TO THE SCALE OF THE DRAWINGS,
a THE CONTRACTOR SHALL BE AWARE THAT MINOR ADJUSTMENTS TO THE
IRRIGATION SYSTEM MAY BE NECESSARY TO PROVIDE PROPER
5 ETAIL F- ,5 COVERAGE. THESE ADJUSTMENTS COULD INCLUDE NOZZLE CHANGES
1 OCAT AND/OR ADDITION OR DELETION OF INDIVIDUAL HEADS TO COMPENSATE
N W IRRIGATIO - FOR CHANGES MADE ON THE SITE. THE CONTRACTOR SHALL LOCATE O
C INT OLLER - ALL VALVES, LATERAL LINE AND MAINLINE IN PLANTING AREAS. O
FURTHERMORE THE IRRIGATION DESIGN IS DIAGRAMMATIC. ALL PIPING,
VALVES, ETC. SHOWN WITHIN PAVED AREAS IS FOR DESIGN Q
-- CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS �.
- WHEREVER POSSIBLE. THE CONTRACTOR SHALL LOCATE ALL VALVES IN DA H O G A N
SHRUB, GROUNDCOVER OR TURF AREAS. IN
A1. THE IRRIGATION SYSTEM DESIGN IS BASED ON A MINIMUM OPERATING LL sus::, n.."uaWm.wteam r,, zon zas.0000
PRESSURE OF 60 PSI AND MAXIMUM FLOW DEMAND OF GPM. THE C �•.
CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION.
7C4l"xTc 71 p:
L6@Na47E I (INDICATES GENERAL CONSTRUCTION NOTE)
VALV 3O. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)
IRRIGATION LEGEND
2" DOUBLE CHECK VALVE ASSEMBLY
FESCO LF850
1" QUICK COUPLER VALVE AND BOX
TORO 100-SLVLC
BALL VALVE IN INDIVIDUAL BOX
APOLLO WATTS OR
EQUAL
O
t
NEW AUTOMATIC CONTROLLER
TORO SENTINEL
THRUST BLOCK
cQ
•••- CONNECT TO EXISTING
O
NORTH
REMOTE CONTROL VALVE IN
TORO 220
n
`f
CONCRETE VALVE VAULT
VeeeQ
REMOTE CONTROL VALVE IN
TORO 220
N
INDIVIDUAL BOX
0 20'
40'
TORO TPS-SS &
U
SCALE: I"- 2V
MOISTURE SENSOR
TPS-RX
•- SCH 40 PVC IRRIGATION MAIN LINE
3"
BID SET
- SCH 40 PVC PIPE (LATERAL)
1-1/2" UNLESS
DATE 6-16-21
OTHERWISE NOTED
IRRIGATION SLEEVE
SCALE 1"=20'
24 VOLT ENERGIZER WIRE.
#14 UF,
e _ SEPARATE WIRES PLUS COMMON
TO
CONNECT IRRIGATION REMOTE CONTROL
DRAWN RUE
VALVES TO CONTROLLER
3604 ROTARY POP UP SPRINKLER
TORO T7
CHECKED DUN
ADJUSTABLE ROTARY POP UP SPRINKLER
TORO T7
COPVRax,Omu DA.WGAN®ASMOATEs
ADJUSTABLE ROTARY POP UP SPRINKLER
TORO T7
NOZZI ES-
6.0 50 PSI, 48' RADIUS. 5.7 GPM
9.0 50 PSI, 50' RADIUS, 8.3 GPM
IRRIGATION
PLAN
12.0 50 PSI, 51' RADIUS. 11.6 GPM
ADJUSTABLE ROTARY POP UP SPRINKLER
1.5 45 PSI, 35' RADIUS, 1.59 GPM
TORO T5
LAMP VALVE STATION
PAILS
M PA
2' 40 VALVE GALLONS
VALVE SIZE PER MINUTE
(GPM)
DEVELOPMENT ENGINEERING
msippo 07/30/2021 R-418909
SHEET
F-1.4