Loading...
HomeMy WebLinkAboutR-418912rn 00 T qIT n J• 2 MIN. 12" WIDE TRENCH (OR AS REQUIRED TO ALLOW ADEQUATE COMPACTION OF BACKFlLL) FINISH GRADE 0 6° TYP 24" MIN. 0 SOD TOPSOIL DETECT -A -TAPE (BLUE) 6"ABOVE PIPE. 3 NEW PAVEMENT OR EXISTING PAVEMENT PATCH PER SPR STD. PLANS & SPECS (TYP.)-----,, FINISH GRADE 1TYP =' J CLEAN, COMPACTED, SUITABLE 12" MIN. COVER NATIVE BACKFlLL. I SCH 40 PVC MAIN LINE. BUNDLE CONTROLLER WIRES UNDER MAIN LINE ON OPPOSITE SIDE FROM SWING JOINTS (WHEN LATERAL & MAIN SHARE THE SAME IT TRENCH). NOTE: TAPE WIRES PER SPEC, BUT DO NOT TAPE BUNDLED WIRES TO MAIN LINE. MAIN LINE TRENCH 6" NP L 12" MIN. COVER SURFACE ABOVE 4" MIN. 4" MIN. IRRIGATION SLEEVE TRENCHING UNDER PATHWAY OR SIDEWALK EXISTING NT (THICKNESS TYP.) DETECT -A -TAPE (BLUE & RED) SHALL BE 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT (TYP.) ALL BACKFlLL SHALL BE MINERAL AGGREGATE TYPE 2 (14" MINUS CR) SCH.40 PVC SLEEVE WITH MAIN OR LATERAL LINES Sc CONTROL WIRES IN SEPARATE CONDUIT &/OR SLEEVE (TYP.) NOTES- 1. SLEEVE ID SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN OD SIZE OF THE PIPE. 2. WIRES SHALL BE IN SEPERATE CONDUIT SLEEVE EXCEPT UNDER ROADS WITH HEAVY VEHICLE TRAFFIC. 3. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS & WALL OR FOOTING PENETRATIONS. 4 FINISH 03 I: h+ + k{. TO ZONE '. SPRINKLERS NOTES: .� 1Q AUTOMATIC SOLENOID VALVE WATERTIGHT WIRE O2 36" LOOP, EACH WIRE RUN SPUCES (TYP.) 3 ADD DECODERS IF TWO WIRE APPROVED SIGNAL i . DECODER 'v V V V V V VVv VVV �vVVVVVVVVVv � 7, V V V V V V V V V V V V V 12" CRUSHED III —III, III—j1'- 71 SURFACING TOP COURSE CONTROL WIRE CABLE SCH.40 MAINLINE (TYP.) SECTION B — B THROUGH VAULT HINGED CORRUGATED NON-INFlLLED SYNTHETIC TURF. LOCKING COVER WITH ADHERE TURF TO COVER SET TO ADJUSTABLE FRAME FINISH GRADE +'+, DETECT -A -TAPE (BLUE & RED) SHALL BE + + 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT (TYP.) SELECT NATIVE BACKFlLL SCH.40 PVC SLEEVE WITH MAIN OR LATERAL LINES & CONTROL WIRES IN SEPARATE CONDOR &/OR SLEEVE (TYP.) NOTES- 1 . SLEEVE ID SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN OD SIZE OF THE PIPE. 2. WIRES SHALL BE IN SEPARATE CONDUIT SLEEVE. 3. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS, CURBS, AND SYNTHETIC TURF, AND WHERE SPECIFICALLY SHOWN. 4. ALLOW FOR FLANGE SIZE ON ALL SLEEVES CARRYING HOPE PIPE. 1 TRENCHING FOR MAINLINE & LATERAL PIPE F j3 NOT TO SCALE SCH BO LOCKING "TEE" COVER, BLACK, NOTES. SCH 80 D LABELED "IRRIGATION" 1Q BRASS BALL VALVE, THREADED FINISHED INLET/OUTLET, SIZED PER THE DRAWINGS GRADE 12" OR ASSOCIATED INLET -SIDE PIPE 2" SCH I 02 BRASS UNION SLIP PREFOR T=1TI=111= 03 BRASS NIPPLE SCH TOE NIF E SCH. 80 PVC T i CARSON 1419-12 JUMBO (a) SCHEDULE SO- PVC BUSHING, SaT REL BALL VALVE -_1 BRASS VALVE BOX OR EQUAL© CON1 N W/UNIONS OS MIN. 12" HORIZONTAL & VERTICAL OFFSET Vj FROM MAINLINE m 2" MIN. 2 i 2 SCH. 40 © PLASTIC VALVE BOX, MIN. 12"0 / PVC OUT 7 O MIN. 6" DEPTH 5/8" WASHED PEA GRAVEL PREFORMED SCH 80 PRE -CAST CONCRETE BRICK UNDER EACH TOE NIPPLE 8 1= CORNER OF THE VALVE BOX 2" SCH 80 PVC �_ _®__ 5 09 4 OZ/SY NON -WOVEN GEOTEXTILE SLIP UNION 2" SCH BO PVC NIPPLE E a ___- SCHAD PVC TEE, FITTINGS �& ADAPTERS (AS REQUIRED)—''' .O PVC MAINLINE (TYP.) 9 BALL VALVE IN LANDSCAPE NOT TO SCALE 10" O c O O O O GROUT ALL PENETRATIONS 4" PERFORATED CPEP 12° CRUSHED SURFACING TOP COURSE i. V V V V V V V v V V V V V V V V CONNECT TO + V V V V V V V V V V V V 4 V V V V V V V SUBSURFACE V V V V V V V V V V V V VV V V V V V V V V V VV DRAINAGE SYSTEM Gov ov ov ov ov ov ov ov ov ov ov ov ov ov ov IIIIIIIIIIIIIIIIIIIIIIIIIIII 111-IIhIIL��IIIIII„III, �,IIllill�l1111111111=III III„IIII CCI"TUIKI A — A TLJDnI lCU VAI II T REMOTE CONTROL VALVE MANIFOLD NOT TO SCALE 7 +VAULT, 57.5" X 22" X 22.5" +DEEP INSIDE DIMENSION; y.OLD CASTLE UTILITY VAULT .38-TA OR EQUAL III PLAN ;CH Z ELBOW 40 DEVELOPMENT ENGINEERING msippo 07/30/2021 01 R-418912 REVISION DATE �s 0 enton SCHOOL DISTRICT SIERRA HEIGHTS ELEMENTARY PLAYFIELD RENOVATIONS N 0) N 4 !r ' DA HOGAN HY Ist Avenue swm.w41N " p. 2os2as. 0400 IL 5,,W,uw..ni�,%% BID SET DATE 6-16-21 SCALE NTS DRAWN REF CHECKED DUA COPVREW OID]I DA. WGAN®ASMOARS IRRIGATION DETAILS SHEET F-2e3 SHEET 1 2 OF 18