Loading...
HomeMy WebLinkAboutS-41160105co T 7 O 0 W rmk vej r 7 n N a i 7" 4 REATTACH OVERHEAD EXISTING UTILITY POLE PROPOSED UTILITY ELECTRICAL RESIDENTIAL TO REMAIN (PSE) POLE, INSTALL ELEC SERVICE CABLING (PSE) i RISER CONDUIT AND GUY WIRE (PSE), SEE DETAIL '------------ STA 20+17.17, 25.00' LT ___ _ ______ ---- - -'---"- 1 CA-2.31 CA-4.11 x � \x �+ (2) 4" ELEC (PSE) o z (2)4" TELECOM(COMCAST) ro m i +� WIZ (1) 4" TELECOM (CTL) JTx W ILi- k EXISTING OIH CABLING TYP SECTION o w EXISTING O CABLING J x �x Q > I TO REMAIN (PSE) m �' TO BE REMOVED (PSE) PROPOSED OIH UTILITY (PSE) \ \'�� Q EXISTING UTILITY POLE\CA-2.31 CA-4.01 TO REMAIN (PSE) PROPOSED UTILITYPOLE, INSTALL ELEC RISER CONDUIT AND_ GUY WIRE (PSE) ____---1•---- -�- -- ,S — ---~~ POINT OF INTERSECTION STA 20+84.79, 23.14' RT STA 21+00.00 GARDEN AVE N= EXISTING UTILI STA 31+00.00 N 2ND ST CAUTION!! EXISTING OIH i I EXISTING UTILITY POLE POLE (PSE) TO FIBEROPTIC TO REMAIN (COMCAST) �� a% TO BE REMOVED (CTL) — 32+0 REMAIN ? f 5' RADIUS MIN PROPOSED 264TA i (1)2"ELEC CONDUIT BEND TELECOM VAULT (CTL) (PSE, ST LIGHT) (CTL) STA 21+36.81, 22.00' LT RIM=40.90 I X__ _X—„ X—„—X —„—X —X XX— EXISTING UTILITY POLE TO BE REMOVED (COMCAST) m PROPOSED UTILITY POLE (COMCAST), SEE NOTE 5'363 a STA 21+42.51, 33--- J --SHAJOINT TRENCH, SEE ----ATES DING INDICATES i o OVERHEAD STRAIN WIRE------L I z m NOTE 4, TYP TO BE REMOVED (COMCAST) o x + o RE (2) 4" ELEC (PSE) o SEE NOTE 5 (2) 4" TELECOM (COMCAST) ABOVE GRADE STREET + ? M w m LIGHT CABINET PSE \ 2 4" TELECOM CTL N 2ND ST ) ! ms� (' (CTL) o. TEMPORARY STREET LIGHT + CONDUIT BEND P STA 21+48.03, 24.00' LT ) (SE) o a PROPOSED UTILITY POLE, ELECTRICAL RE -CONNECTION \ z F INSTALL TELECOM FG=41.65 CONDUIT \I STA 22+62.71, 27.00'LT wpm ILINE RISER CONDUIT AND GUY (2) 4' EXISTING UTILITY POLE +\ i u m i SEEMATHEET WIRE (CTL) CONDUIT (CTL) TO BE REMOVED (PSE) + 43 SEE SHEET CA-2.51 STA 21+68.46, 129.90' RT SEE NOTE 1 I (1) 2"ELEC (PSE, ST LIGHT) p VACATED RIGHT-OF-WAY x =x T =x �x TLx —�T� x cT�—cn— cTL Ilil{ —x —x —' — .--_.----_--- — — — — MATCHL_I_NESEE SHETCA-2.21 1 300 BRONSON WAY EXISTING UTILITY POLE TO REMAIN, OVERHEAD TO BE RE -STRUNG BY PURVEYOR (CTL) 45 T P.O. Box Seattle,le, WAA 98 FIL Patrick@hl.enginengineenng HLENGINEERING (858)581-0754 i NOTES: EXISTING UTILITY POLE TO REMAIN (PSE)—^ 1. COORDINATE UTILITY POLE REMOVAL WITH PURVEYOR. SEQUENCE WORK WITH STREET IMPROVEMENTS AS NEEDED TO PROVIDE CONTINUOUS STREET LIGHTING. k PROPOSED UTILITY POLE, I 2. UNLESS NOTED OTHERWISE, CONDUIT BEND RADII SHALL BE 4' MINIMUM. DEPTH OF INSTALL ELEC RISER CONDUIT k COVER OVER STREET LIGHT CONDUIT OUTSIDE OF JOINT TRENCHING CONDITION SHALL IN ¢ AND GUY WIRE (PSE) 18" MIN. DEPTH OF COVER OVER PRIMARY CONDUIT OUTSIDE OF JOINT TRENCHING w STA 39+65.11, 20.00' RT CONDITION SHALL BE 36" MIN. N SEE DETAIL z 2 3. PROVIDE REPLACEMENT SURFACING (SIDEWALK OR VEHICLE PAVEMENT) MATCHING z 8 CA-2.31 CA4.11 EXISTING OR PROPOSED NEW CONDITION OVER UTILITY TRENCH ROUTES. 4. UTILITY JOINT TRENCH PER PURVEYOR'S REQUIREMENTS. w N I SEE TYPICAL DETAIL CA-2.31 CA4.11 (1)4" TELECOM CONDUIT (CTL) ICI 5. PRIOR TO REMOVAL OF EXISTING UTILITY POLE, CONTRACTOR TO COORDINATE WITH w (1) 4" ELEC (PSE) PURVEYOR (COMCAST) THE SCHEDULE AND DURATION OF TEMPORARY SUPPORT OF z (1) 2" ELEC (PSE, ST LIGH FIBEROPTIC OVERHEAD CABLING AND REQUIRED TRAFFIC CONTROL APPROVALS WITH THE w T�I CITY OF RENTON. FOLLOWING TEMPORARY CABLING SUPPORT BY PURVEYOR, REMOVE m m m F EASTERLY EXISTING STRAIN WIRE AND EXISTING UTILITY POLE COMPLETELY, AND INSTALL o o o I i STRUCTURAL (GLULAM POLE) AS PART OF CONTRACTOR DESIGN -BUILD IN SAME LOCATION, rN ^moo �.QSFc fnI U. CONSTRAINED UTILITY CROSSING: CONDUIT TO BE INSTALLED 12" MIN ABOVE EXISTING SO o r mo o N < z z w r No o r J 7. CONSTRAINED UTILITY CROSSING: CONDUIT(CTL)TO BE INSTALLED 12" MIN BELOW w¢ m O �¢ 2 ov o o Q o ¢ 2 u I PROPOSED SD (SEE SHEET CC-8.13) AND EXISTING GAS. o r— m w— w m z r m w r— x 68. FIELD ADJUST PSE ELEC, CENTURY LINK, AND COMCAST CONDUIT HORIZONTAL AND VERTICAL ALIGNMENT TO MAINTAIN V MINIMUM SEPARATION FROM WATER, SEWER, AND EXISTING UTILITY LI REMAIN, STORM DRAINAGE INFRASTRUCTURE. POLE RIGHT-OF-WAY, TYP loll „� �Em i CENTERLINE EXISTING MEDIAN ISLAND ---------------------------------------------- CTL_TY + (RIGHT-OF-WAY) TO REMAIN +/ POINT +8 INTERSECTION +/ 0 w 33+00 N 2ND S T ml YYYY��� STA 33+00.00 N 2ND W " —. STA 41+00.00 MEADOW AVE N +'+ u—�'+---------- ELEC HANDHOLE PSE, ST LIGH 0 --►a (1) 4" ELEC (PSE) 'o STA 41+20.81, 22.40' RT PROPOSED UTILITY POLE, / 16 N O (2) 4" TELECOM (1) 2" ELEC (PSE, ST LIGHT) m x r EXISTING UTILITY POLE RIM = 40.94 INSTALL TELECOM CONDUIT (CTL) (1) 4"TELECOM (COMCAST) —„ - „ „ X TO BE REMOVED (CTL) RISER CONDUIT AND (2)4"TELECOM (CTL) - ;n 11 GUY WIRE (CTL) X X X—X X X —X— X X --- —X—X �---� oaia sd L—�� T LTL—LTL X4T STA4120.40,56.90LT x TCHLINE U SEE SHEET CA-2.41 Hw r z,n Y n Z zm w t-Km w II m �I z VJ z o * z W (2) 4" TELECOM CONDUIT (CTL) i.�+ z w i EXISTING UTILITY POLE TO BE REMOVED (CTL) • (1) 2" ELEC (PSE, ST LIGHT) ELEC SERVICES FOR 1300 AND j �I w II II}r 1408 BRONSON WAY NORTH. 0 II II CONDUIT BUNDLES TBD. SEE C:) J II PSE ORDER No. 101121708 FOR I m Q I Q • DETAILS LLJ V DEDICATED RIGHT-OF-WAY IN COMPLIANCE WITH CITY OF RENTON STANDARDS 20 10 0 20 40 scale 1" = 20' feet — �xeAS-NOTED °°' "" CITY OF CITC HEADQUARTERS FAH --- RENTON 1300 BRONSON WAY N, RENTON WA 98 aWa DATUM UTILITY CONVERSION PLAN AT M ME Plonning/Building/Public Works Dept. N 2ND ST N0. REVISION BY DATE APPR ^°^"^^^ """'IX01°'""' 10.11 CA-2.3 5 9