Loading...
HomeMy WebLinkAboutS-41160106I co I r Lu � I I � I I � I I � I I � I I I I (n ry Ld ry \ Q W POINT OF INTERSECTION = STA 33+82.06 N 2ND ST= STA 41+00.00 MEADOW AVE N U \ I U \\ I \I Ii x x— x— x— x x— x x-- x x— x—k x— x- 7� 7 C4 N a i ►� T k: i V V�~/� I /i I Ila Z Ilu II cV i V I I+ 50 45 40 35 30 A HLENGINEERING P.O. Box 81211 Seattle, WA 98108 patrick@hLengineenng (858) 581-0754 � wwm N w F N + W U e > + e e EXISTING OIH CABLING TO BE REMOVED (PSE) TEMPORARY STREET LIGHT ELECTRICAL RE -CONNECTION CONDUIT w 42+00 w EXISTING UTILITY POLE y TO BE REMOVED (PSE) SEE NOTE 1 LOCATE AND INTERCEPT EXISTING ELEC AND TELECOM CONDUIT (PSE, COMCAST) TYP SECTION m + + CA-2.41 CA-4.01 = N e N V e n z e MEADOW AVE N+OB —x—xxtix�x—x—x x—xx�x�,,, —— I PSE ELEC � PSE ELEC (1)2"ELEC (1)2"ELEC (PSE, ST LIGHT) (PSE, ST LI A R4W. �� 48fi01 •$ FCLs-rva� VNAL6 x—x—x x—x—x—x x— PSE EI --PSE ELEC EXISTING n a u � I U I 0 0 w¢ I U ' I =c � N < o o^� I ¢ RIGHT-OF-WAY, TYP HN(Y POINT OF INTERSECTION STA 44+62.12 BRONSON WAY I (1) 2" ELEC STA 44+62.12 MEADOW AVE N (PSE, ST LIGHT) 44+00 CENTERLINE I CO (RIGHT-OF-WAY) o <T O —PSE ELEC PSE ELEC EXISTING UTILITY POLE II Z TO BE REMOVED (CTL) SEE NOTE 1 N g '8 J HT RIGHT-OF-WAY II \ w II ` z h w o o vwi w o o TEMPORARY STREET LIGHT ELECTRICAL RE -CONNECTION m N I z e z CONDUIT + ELEC SERVICE FOR 1408 BRONSON WAY NORTH z < I, z (REPLACEMENT OF EXISTING MEADOW AVE N o o SHADING INDICATES OIH TRANSFORMER TO BE REMOVED). CONDUIT JOINT TRENCH, SEE DEDICATED BUNDLE TBD. SEE PSE ORDER o u m a � N � NOTE 4, TYP RIGHT-OF-WAY �I I No. 101121708 FOR DETAILS �'• 0 o + 1. COORDINATE UTILITY POLE REMOVAL WITH PURVEYOR. SEQUENCE WORK WITH STREET IMPROVEMENTS AS NEEDED TO PROVIDE CONTINUOUS STREET LIGHTING. 2. UNLESS NOTED OTHERWISE, CONDUIT BEND RADII SHALL BE 4' MINIMUM. DEPTH OF COVER OVER STREET LIGHT CONDUIT OUTSIDE OF JOINT TRENCHING CONDITION SHALL BE 18" MIN. DEPTH OF COVER OVER PRIMARY CONDUIT OUTSIDE OF JOINT TRENCHING CONDITION SHALL BE 36" MIN. 3. PROVIDE REPLACEMENT SURFACING(SIDEWALK OR VEHICLE PAVEMENT) MATCHING EXISTING OR PROPOSED NEW CONDITION OVER UTILITY TRENCH ROUTES. 4. UTILITY JOINT TRENCH PER PURVEYOR'S REQUIREMENTS. SEE TYPICAL DETAIL 3 CA_2.41 CA-4.11 5. FIELD ADJUST PSE ELEC, CENTURY LINK, AND COMCAST CONDUIT HORIZONTAL AND VERTICAL ALIGNMENT TO MAINTAIN T MINIMUM SEPARATION FROM WATER, SEWER, AND STORM DRAINAGE INFRASTRUCTURE. 50 45 40 35 30 FOR REFERENCE ONLY; UTILITY CONVERSION UNDER SEPARATE PERMIT. S-411606 IN COMPLIANCE WITH CITY OF RENTON STANDARDS �xe�AS-NOTED CITY OF CITC HEADQUARTERS PAH --- RENTON 1300 BRONSON WAY N, RENTON WA 98 BWR DATUM NLL� UTILITY CONVERSION PLAN FM1FO' � •*� Plonning/Building/Public Works Dept. NO. REVISION BY DATE APPR "°^"^^^ """"`p°'N"' MEADOW AVE N 10.11 CA-2.4 6 w9