Loading...
HomeMy WebLinkAboutR-41160151z: U) ry W Q 0 W U 0 LF 6"SO I OUT IE = 3 .65) CB TY E1 PER STD PLAN 20 .00 SOLID LID PER 20 .10 STA 51+31.61, 26.3 LT RIM = 4 .32 IE (IN) 39.70 (6" W) IE (OUT) = 39.70 (6 S) CB TY E 1 PER STD PLAN 200 00 SOLID LID PER 204. 0 sn(ErSTA 51+31. I RIM=4y IE (IN) = 39.79IT IE (OUT) = 39.79 (6" E t � NOTES: i O C 1. PARKING LOT, WALKWAYS, AND ALLEY GRADED TOWARD BIORETENTION. 2. CURB CUTS SIZED FOR 100 YEAR FLOW. 3. BIORETENTION SIZED TO MEET ENHANCED TREATMENTSTANDARD. 4. COR REQUIRES 6' SAND AND IMPERMEABLE LINER BELOW BIORETENTION FOR BIORETENTION CONSTRUCTION IN AQUIFER PROTECTION ZONE 1. T OPENING NON -INFILTRATING INLET, 5. ALL CONNECTIONS MUST BE WATERTIGHT. SEE RMC 4-3-050 FOR PIPE CDR STD 262 WITH PRE -SETTLING OUTLET COR 262 0 SPECIFICATIONS INCLUDING ACCEPTABLE JOINTS. PER COR STD 262.30 : 808 SF (77' X 10.51) RIM = 40.40 SIX (6) IN TOTAL IE IN = 37.48 (6" N BIORETENTION ELEVATIONS: TC = 41.65 IE OUT = 37.48 (6' W) TC = TOP OF CURB 6" PVC PERF. BC = 41.48 = 42.15 BC = BOTTOM OF CURB TM = 39.65 7AB UNDERDRAIN B -41.87 TM = TOP OF BIORETENTION SOIL MEDIA BG = 37.48 TM 39.65 BG = BOTTOM OF GRAVEL LAYER BG .48 TC = 41.65 --- - BC=41.15 TC-4215 9LF 6"DI TM = 39.65 BC = 41.65 G=37.48 _- ---------------------------- TM=39.65 ,❑ ❑ BG=37.48 SEE ENLARGEMENT FOR ELEV. CB TYPE 1 t LF 6" DI PER STD PLAN 200.00 _ 3l3 3sa- 3 VAR SEE LARCH FOR PLANTINGS 26 LF 6" DI TO EX. CB TYPE 1 CB STA 52+2128 (OUT IE=39.95) SOLID LID PER 204.10 VAR IN IE = 365 (6" E) STA 52+26.87, 26.45 LT p EX. CB IE - 35.77 (12" N) RIM = 41.73 ,. i6 LF 6"DI IE OUT=40.60(6"N) _ IE IN=40.60(6"E, W) �O ISO! SD<E� SD(Et _ § Y-- S➢(E� SD<E� S➢(E� S➢(E�- SD<E S➢(E� S➢(E SD(E� SD(E� SD(E� SD(E� SD(E S p p =_99T •�=�ST> SS(E SS(E� SS(E� SS(E� SS(E� SS(E SS(Er---SS(EimSS(E� SS(E� SS(E MPR�LLEvEMEABLE 6" PERF PVC cT( rn - cn LINER, 40 MIL PVC UNDERDRAIN 6" SAND BELOW CONCRETE BIORETENTION ENLARGEMENT 8" GRAVEL 1"=10, SEE ENLARGEMENT FOR ELEV. VAR VAR 4 c ° IMPERMEABLE LINER, 40 MIL PVC SEE LARCH FOR PLANTINGS FLONGITUDINAL SLOPE - 0.6 d ° ° INLET 18" BIORETENTION SOIL COR STD 262.60 - 6" PERF PVC UNDERDRAIN 8" GRAVEL J CONCRETE WALLS AND BOTTOM PER STRUCTURAL SEE COR STD 262.40 SET OPENING 0.75' ABOVE SOIL - e 4 ° ° e 0.75' f 6" SOLID PVC 6" SAND BELOW CONCRETE BIORETENTION SECTION - LONGITUDINAL T 111 = 2' CC-8.12 CC-8.13 _o K w h N I I 'w`I 4218 Meridian Ave a N ,d1a V B I 1 V Seahle, WA 98103 tony@dubinenv.Dom Environmental (206) 898-0057 V1 N N N a n SEE ENLARGEMENT FOR � VAR 18" BIORETENTION SOIL COR STD 262.60 CONCRETE WALLS AND BOTTOM PER STRUCTURAL BIORETENTION SECTION - NORTH 11 = 2, SEE ENLARGEMENT FOR ELEV. I- VAR I VAR SEE LARCH FOR PLANTINGS IMPERMEABLE 6" PERF PVC LINER, 40 MIL PVC UNDERDRAIN SEE CDR STD 262.40 SET OPENING 0.76 ABOVE SOIL 0.75, 6" SOLID PVC L 6" SAND BELOW CONCRETE 8" GRAVEL BIORETENTION SECTION - SOUTH 11 = 2, AS-NNONE 196* OTED v�z°",k:'"'°'°"n", ; CITY Or Nmro RENTON ATME TD DATUM �PHL Planning/Building/Public Works Dept. N0. REVISION BY DATE APPR ''IX01°'NMY 13 18" BIORETENTION SOIL COR STD 262.60 CONCRETE WALLS AND BOTTOM PER STRUCTURAL 13 I T W _W U u R-411629 0�_ IN COMPLIANCE WITH CITY OF RENTON STANDARDS W DEVELOPMENT ENGINEERING Q jchavez 08/28/2020 O :D Q CITC RENTON 1300 BRONSON WAY N RENTON, WA 98057 BIORETENTION ENLARGEMENT SFCTIONS "2020.07.02 W _ (> ^"K �N_ CC-8.14AND ""` 42 Of 58 U