Loading...
HomeMy WebLinkAboutR-412219N N T I LL1 CacuSq, Envelme to 5D308A1A-2ND40E&BB23AA3831BB%5E GENERAL NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS), 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS([ L JUNCTION BOXES SHALL HAVE NON-SKQ LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBERCOMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 7. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. 8. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL, NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. R TANSPORTATION NOTES Fric PLAN — 135 PUBLIC WORKS 0` _.,P' DEPARTMENT GAZ 3/13/2019 I a: GENERAL NOTES: w 1. FIELD VERIFY LIGHT POLE LOCATIONS TO CONFIRM 5'-0" MINIMUM FROM ALL SEWER AND WATER d SERVICES TO BUILDINGS. z 2. PROVIDE A GRADE BOX WHERE SHOWN ON PLAN. 0 3. LIGHTING SCHEDULES AND DETAILS ARE LOCATED ON SHEET E1.2. U 4. ELECTRICAL BOX SIZE AS SHOWN ON PLAN AND PER CITY OF RENTON STANDARD DETAILS 122.1, 0 122.2, AND 126.1. SEE SHEET L1.1 FOR LANDSCAPE SCREENING. PRESSLER w !�� Engineer ng, Inc1•=30'9"' CITY OF RENTON 22122 20tN Ave SE BBNSuite 161 CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4 07 J� WOMMEMN Planning/Building/Public Works Dept. BOTHELL, WASHINGTON 98021 � y (425) 485-3002 FM 485-811a NO. REVISION BY DATE APPR E R-412219 U a J 9 IN COMPLIANCE WITH CITY OF RENTON STANDARDS = CL DEVELOPMENT ENGINEERING � Q MSippo 06/03/2020 Z F_ H EC O LL LA FORTUNA PH III lime 02/13/20 J 17210-17324127TH STREET, RENTON, WA ELECTRICAL E1.1 = SITE LIGHTING ' 19'29