HomeMy WebLinkAboutR-412222Em
EX. EXCELSA CEDARS (5) 6"-8",REF.
TREE REPORT BY GREENFOREST -
INCORPORATED, 3/27/2020
EX. WESTERN RED CEDAR, 1 T' DBH, IF
ROOTS 1"DIA. OR GREATER ARE
ENCOUNTERED, TO BE INSPECTED BY
PROJECT ARBORIST, AND RECOM.
�I MADE AT THAT TIME FOR MITIGATION
_ (ROOT PRUNING, BRANCH PRUNING
OR TREE REMOVAL), REF. TREE REPORT
BY GREENFOREST INC., 3/27/2020
176r,A, 1 0 C A
TREE PROTECTION
AT PROPERTY LINE
SMH-4 �
\ � TREE NUMBERS GENERATED FOR REFERENCE ONLY PROPOSED TREES SHOWN FOR i
BY KKLA. NUMBERED TREES USED FOR TREE CALCS., REFERENCE ONLY, NOT INCLUDED IN , T E . \
REF. L0.2, ADDL. SURVEY TREES IDENTIFIED MINIMUM TREE DENSITY CALCULATIONS. li
a¢I AFTERWARDS ARE NOT USED IN CALCS., TYR.
SEE LI A FOR PROPOSED TREES AND
00
0
-CB7-rlL _- --- ---
TREE PROTECTION IS FROM CENTER
OF TREE, EXTEND TO DRIPLINE,REF. NI
TREE REPORT BY GREENFOREST EX. CHERRY TREE, T' DBH,
INCORPORATED, V-7/2020 TO BE REMOVED, CUT TO GRADE
CU LV�Z 1 - - AND LEAVE ROOT BALL, REF. TREE
O REPORT BY GREENFOREST
IE 80.66 �� \ INCORPORATED, 3/27/2020
V CB-4 T
THAND,
__._ TREE PROTECTION VSOUTH OF
PERTY LINE. ANY EXCAVATION
ETWEEN LIMIT OF DISTURBANCE
AND FENCE SHALL BE DONE BY
INJURING NO ROOTS, REF.
TREE REPORT BY GREENFOREST
INCORPORATED, 3/27/2020
�m II
• - �ItRr_II���III�111C�II� Ili 1111
/ LANDSCAPE, TYP. L -
/
- --
ot9 — EXISTING TREE TO BE RETAINED, -- _
\ SEE SHEET L0.2 FOR TREE i EX. DECID.
LEGEND AND NOTES, TYP. TREE TO BE -
I�\P. REMOVED SM -11 --1-
029
' TREE PROTECTION r
ADDL. TREES SURVEYED NOT � i /
USED IN TREE CALCS., TYP.
�o F A2 • 11
_ I� 1 _NII YIYA, / ••
1:
D
059- �
P A16
PA4
AS
/tA9P
Tree Plan
scale I"=2U'-a
10
51
r_m
MH-86-18 (PER SOOS
CREEK AS -GUILTS)
OF WA3Hi
Karen Kiest P pE" s FsIOD
Landscape Architects h d
111 west john street suite 306
seattle washington 98119 `�14 95 ExP.
tel 206 323 6032 'Arroscnve pP PNO
C
TREE HAS FALLEN, PER
ADDL. TREE SURVEY
INFORMATION
I
I
'
I
_
I I T
T
I I
/
1
1
11
U
O
I
I I I
1I
I
nn
II
uu
n
1
JB-15
n
u
0
IIIII
20
REVISION
� I
F
I
WETLAND MAIL KIOSK
BUFFER
i I
15SETBACK
\� I
I
fflSE
J WVC-
S1��0
�_ _ii-ter _tL ___
II 0 I II I CB-13 I
11 I II I
II I
I I
I
CB-12
I
G
SSMH-13-11
I
SEE GAS NOTE
BUILDING
I
I
I
CB-21
Pv r
40
I NOTE:
1. FOR EXISTING TREE LEGEND AND
NOTES, SEE SHEET L0.2
2. FOR PROPOSED PLANTING AND
TREES, SEE SHEET 1.1.1
1"=20' ��=MT, CITY OF
RENTON
�� DATUM
Planning/Building/Public Works Dept.
I I
II I
I I I II
I
MINE
2
LINE
I j J
1
• ,J I 2
m
U)
W
IL
Z
0
U
Z
I O 0
A
IN COMPLIANCE WITH CITY OF RENTON STANDARDS =
d
DEVELOPMENT ENGINEERING Q
MSippo 06/03/2020
H
0
ILL.
LA FORTUNA PH II ° °02/13/20
17210-17324 127TH STREET, RENTON, WA
TREE PLAN _
w. L0.1