Loading...
HomeMy WebLinkAboutR-412222Em EX. EXCELSA CEDARS (5) 6"-8",REF. TREE REPORT BY GREENFOREST - INCORPORATED, 3/27/2020 EX. WESTERN RED CEDAR, 1 T' DBH, IF ROOTS 1"DIA. OR GREATER ARE ENCOUNTERED, TO BE INSPECTED BY PROJECT ARBORIST, AND RECOM. �I MADE AT THAT TIME FOR MITIGATION _ (ROOT PRUNING, BRANCH PRUNING OR TREE REMOVAL), REF. TREE REPORT BY GREENFOREST INC., 3/27/2020 176r,A, 1 0 C A TREE PROTECTION AT PROPERTY LINE SMH-4 � \ � TREE NUMBERS GENERATED FOR REFERENCE ONLY PROPOSED TREES SHOWN FOR i BY KKLA. NUMBERED TREES USED FOR TREE CALCS., REFERENCE ONLY, NOT INCLUDED IN , T E . \ REF. L0.2, ADDL. SURVEY TREES IDENTIFIED MINIMUM TREE DENSITY CALCULATIONS. li a¢I AFTERWARDS ARE NOT USED IN CALCS., TYR. SEE LI A FOR PROPOSED TREES AND 00 0 -CB7-rlL _- --- --- TREE PROTECTION IS FROM CENTER OF TREE, EXTEND TO DRIPLINE,REF. NI TREE REPORT BY GREENFOREST EX. CHERRY TREE, T' DBH, INCORPORATED, V-7/2020 TO BE REMOVED, CUT TO GRADE CU LV�Z 1 - - AND LEAVE ROOT BALL, REF. TREE O REPORT BY GREENFOREST IE 80.66 �� \ INCORPORATED, 3/27/2020 V CB-4 T THAND, __._ TREE PROTECTION VSOUTH OF PERTY LINE. ANY EXCAVATION ETWEEN LIMIT OF DISTURBANCE AND FENCE SHALL BE DONE BY INJURING NO ROOTS, REF. TREE REPORT BY GREENFOREST INCORPORATED, 3/27/2020 �m II • - �ItRr_II���III�111C�II� Ili 1111 / LANDSCAPE, TYP. L - / - -- ot9 — EXISTING TREE TO BE RETAINED, -- _ \ SEE SHEET L0.2 FOR TREE i EX. DECID. LEGEND AND NOTES, TYP. TREE TO BE - I�\P. REMOVED SM -11 --1- 029 ' TREE PROTECTION r ADDL. TREES SURVEYED NOT � i / USED IN TREE CALCS., TYP. �o F A2 • 11 _ I� 1 _NII YIYA, / •• 1: D 059- � P A16 PA4 AS /tA9P Tree Plan scale I"=2U'-a 10 51 r_m MH-86-18 (PER SOOS CREEK AS -GUILTS) OF WA3Hi Karen Kiest P pE" s FsIOD Landscape Architects h d 111 west john street suite 306 seattle washington 98119 `�14 95 ExP. tel 206 323 6032 'Arroscnve pP PNO C TREE HAS FALLEN, PER ADDL. TREE SURVEY INFORMATION I I ' I _ I I T T I I / 1 1 11 U O I I I I 1I I nn II uu n 1 JB-15 n u 0 IIIII 20 REVISION � I F I WETLAND MAIL KIOSK BUFFER i I 15SETBACK \� I I fflSE J WVC- S1��0 �_ _ii-ter _tL ___ II 0 I II I CB-13 I 11 I II I II I I I I CB-12 I G SSMH-13-11 I SEE GAS NOTE BUILDING I I I CB-21 Pv r 40 I NOTE: 1. FOR EXISTING TREE LEGEND AND NOTES, SEE SHEET L0.2 2. FOR PROPOSED PLANTING AND TREES, SEE SHEET 1.1.1 1"=20' ��=MT, CITY OF RENTON �� DATUM Planning/Building/Public Works Dept. I I II I I I I II I MINE 2 LINE I j J 1 • ,J I 2 m U) W IL Z 0 U Z I O 0 A IN COMPLIANCE WITH CITY OF RENTON STANDARDS = d DEVELOPMENT ENGINEERING Q MSippo 06/03/2020 H 0 ILL. LA FORTUNA PH II ° °02/13/20 17210-17324 127TH STREET, RENTON, WA TREE PLAN _ w. L0.1