Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-416634
IRRIGATION DETAILS co I 0 0 X to w m 0 ry 0 U J rn r-> N a / N / 0 0 0 N la) / Lqa) a E DRIPLINE CENTER FEED LAYOUT NOT TO SCALE T PVC EXHAUST HEADER ( PVC SCH 40 TEE OR EL (TYPICAL) 30 BARB X MALE FITTING 40 FLUSH POINT (TYPICAL) SEE DETAIL ( PERIMETER OF AREA ( PERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM PERIMETER OF AREA O PVC SUPPLY PIPE FROM CONTROL ZONE KIT (SIZED TO MEET LATERAL FLOW DEMAND) 80 PVC SUPPLY MANIFOLD 90 CONNECTION FROM SUPPLY MANIFOLD TO DRIPLINE (TYPICAL)— SEE INSET A OF ELLIOTT FARMS A PORTION OF SECTION 22, TOWNSHIP 23 N. RANGE 05 E., W.M. 10 SUB —SURFACE DRIPLINE CITY OF RENTON, KING COUNTY, WASHINGTON 11 BLANK TUBING RECORD DRAWING 12 BARB X BARB INSERT TEE OR CROSS: 13 Y2" AIR RELIEF VALVE 14 BARB X FEMALE FITTING: PVC NIPPLE, LENGTH AS NECESSARY 16 DRIPLINE INDICATOR. SEE DETAIL FOR ADDITIONAL INFORMATION Dripline Maximum Lateral Lengths (Feet) Inlet Pressure psi 12" Spacing 18" Spacing 24" Spacing Nominal Flow (gph) Nominal Flow (gph) Nominal Flow (gph) 0.6 1 0.9 0.6 0.9 0.6 0.9 15 273 155 314 250 424 322 20 318 169 353 294 508 368 30 360 230 413 350 586 414 40 1 395 255 465 402 652 474 50 417 285 528 420 720 488 60 460 290 596 455 780 514 INSET A NOTES: 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE IRRIGATION SCHEDULE FOR SPACING. 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. 3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA. 4. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. O PVC EXHAUST HEADER 20PVC SCH 40 TEE OR EL (TYPICAL) 03 FLUSH POINT (TYPICAL) SEE DETAIL 04 BARB X MALE FITTING 05 PERIMETER OF AREA 06 BARB X BARB INSERT TEE OR CROSS 07 PERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM PERIMETER OF AREA ( SUB —SURFACE DRIPLINE: SEE IRRIGATION SCHEDULE 09 BLANK TUBING 10 )'" AIR RELIEF VALVE: SEE DETAIL 11 PVC SUPPLY MANIFOLD 12 PVC SUPPLY PIPE FROM CONTROL ZONE KIT (SIZED TO MEET LATERAL FLOW DEMAND) 13 TOTAL LENGTH OF SELECTED DRIPLINE SHOULD NOT EXCEED LENGTH SHOWN IN TABLE 14 PVC SCH 40 RISER PIPE 15 DRIPLINE INDICATOR. SEE DETAIL FOR ADDT'L INFO NOTES: • DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE MANUFACTURER DRIPLINE INSTALLATION GUIDE FOR SUGGESTED SPACINGS. • LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. • AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA. • WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. 4-6" DRIP MANIFOLD BURIAL DEPTH INSET A DRIPLINE IRREGULAR SHAPED LAYOUT NOT TO SCALE INSET A r—� DRIPLINE ODD CURVES LAYOUT NOT TO SCALE NOTES: 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS FOR SPACING 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE. 3. INSTALL AIR RELIEF VALVE AT HIGH POINTS IN DRIP LATERAL. 4. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. 01 PVC SUPPLY PIPE FROM RAIN BIRD ® ARB X BARB INSERT TEE CONTROL ZONE KIT (SIZED TO MEET LATERAL FLOW DEMAND) 90 TOTAL LENGTH OF SELECTED DRIPLINE SHOULD A NOT EXCEED LENGTH SHOWN IN TABLE O PERIMETER OF AREA 14 13 10 PVC FLUSH HEADER O PERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM PERIMETER OF AREA 11 FLUSH POINT: Ly SEE DETAIL ® PVC SUPPLY MANIFOLD 4-6° 12 PVC RISER PIPE MANIFOLD O PVC SCH 40 TEE OR EL (TYPICAL) 13 TURF OR MULCH IAL DEPTH © BARB X MALE FITTING 14 FINISH GRADE 1 5 4 O SUB—SURFACE SEE IRRIGATION SCHEDULE 0 15 1/2 AIR RELIEF VALVE: SEE DETAIL INSET A , 12 16 DRIPLINE INDICATOR. SEE DETAIL FOR ADDT'L INFO SURVEY DATUM 7 HWR NPL Ill 141MIAL Ill MIUMVIL DAIM 6 WD IN991) PER CITY OF VERTICAL D91111 FM TH6 SIX 6 REMON. CITY OF REMON CONTROL vorlr N0. 1857 6 NAVD 1988 PER CRY OF WAS HELD FOR POSH AND A UE BE MMN CITY REMM. CRY OF RENRNI OF RENr01 CONRIOL PONr N0. 1910 AND WWA POW NO. 2192 WAS OONMM PONT Na 1850 WAS HEIR FM WIMIX HEIR FOR E1E1 IDIC BEND NO. BEING S55'3Y23E. 9&199 FEEFQNVIM). RECORD DRAWING AS —BUILT REC EQUIPMENT and MONUMENT SIGN REVISION 2 DRIPLINE END FEED LAYOUT NOT TO SCALE DRIPLINE SLOPED LAYOUT NOT TO SCALE TCR 15.27.221 JMV JMV 14.19.221 JMV BY I DATE I APPR SURVEYED: I SCALE: DESIGNED: TCR DRAWN. TCR ONE INCH SCALE AT FULLJIMv CHECKED: IF NOT ONE INCH SCALE ACCORDINGLY APPROVED: JMV NOTES: • DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE DRIPLINE INSTALLATION GUIDE FOR SUGGESTED SPACINGS. • LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. • AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA. • WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. re VERTICAL• NAVD 19a8 HORIZONTAL: HAD 1983/1991 DATUM 4-6" DRIP MANIFOLD BURIAL DEPTH INSET A O PVC EXHAUST HEADER ( PVC SCH 40 TEE OR EL (TYPICAL) ( BARB X MALE FITTING: T FLUSH POINT (TYPICAL) SEE RAIN BIRD DETAIL 'FLUSH POINT WITH BALL VALVE' O PERIMETER OF AREA O PERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM PERIMETER OF AREA O SUB —SURFACE DRIPLINE 80 BLANK TUBING 90 BARB X BARB INSERT TEE OR CROSS: 10 Y2" AIR RELIEF VALVE 11 PVC SUPPLY HEADER 12 PVC DRIP MANIFOLD FROM CONTROL ZONE VALVE KIT (SIZED TO MEET LATERAL FLOW DEMAND) 13 PVC SCH 40 RISER PIPE 14 DRIPLINE INDICATOR. SEE DETAIL FOR ADDT'L INFO Dripline Maximum Lateral Lengths (Feet) Inlet Pressure psi 12" Spacing 18" Spacing 24" Spacing Nominal Flow (gph) Nominal Flow (gph) Nominal Flow (gph) __0.6 0.9 0.6 1 0.9 0.6 1 0.9 15 273 155 314 250 424 322 20 318 169 353 294 508 368 30 360 230 413 350 586 414 40 395 255 465 402 652 474 50 417 285 528 420 720 488 60 460 290 1 596 1 455 780 514 NOTES: • DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. DISTANCE BETWEEN LATERAL ROWS FOR BOTTOM 1 /3 OF SLOPE TO BE SPACED GREATER THAN OPTIMAL ROW DISTANCE. SEE RAIN BIRD XFD DRIPLINE INSTALLATION GUIDE FOR SUGGESTED SPACING. • LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. • WHEN ELEVATION CHANGE EXCEEDS 8 FEET IT IS RECOMMENDED THAT A NEW DRIPLINE ZONE BE CREATED. • INSTALL AIR RELIEF VALVE AT HIGH POINTS IN DRIP LATERAL. • WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. O PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL ZONE VALVE KIT (SIZED 11 TO MEET LATERAL FLOW DEMAND) 12 O BARB X MALE FITTING: O PVC SUPPLY HEADER 4-6" ® PVC SCH 40 TEE OR EL (TYPICAL) DRIP MANIFOLD BURIAL DEPTH O SUB —SURFACE DRIPLINE: 10 PVC RISER PIPE 11 TURF OR MULCH 12 FINISH GRADE OODU © FLUSH POINT: SEE RAIN BIRD XFS DETAILS FOR FLUSH POINT 1 INSTALLATION 4 O7 PVC FLUSH HEADER INSET A ® Y" AIR RELIEF VALVE: RAIN BIRD MODEL: ARV050 0 DRIPLINE INDICATOR. SEE DETAIL FOR ADDITIONAL INFORMATION CITY OF- 1;%R] RENTON vugv Planning/Building/Public Works Dept. RECORD DRAWINGS R-416634 V E V Id � H � � t ._ 0 vM Ln i LLB N N M 4A i QOON (n N � >a� rq > L0 i C Ln aS N W U 22 Y IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRIPOINTE HOMES (425) 455-2900 15900 SE EASTGATE WAY. SUITE 300 BELLEVUE, WA 98008 DATE: 05-27-22 FIELDBOOK: PAGE 34 °F 46 0 O I L0 cn N O Qz F--O OLj JUJ