HomeMy WebLinkAboutR-416633C0
O
0
1O EASY FIT COMPRESSION TEE:
RAIN BIRD MDCFTEE
O2 SUB -SURFACE DRIPLINE:
RAIN BIRD XF SERIES DRIPLINE
POTABLE: XFS DRIPLINE
NON -POTABLE: XFSP DRIPLINE
30 INLINE DRIP EMITTER
O4 TIE DOWN STAKE: RAIN BIRD TDS-050
WITH BEND (TYPICAL)
O5 TURF/FINISH GRADE OR SHRUB BED
WITH MULCH
NOTES:
1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND
FIVE FEET IN CLAY.
2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR
ELBOWS, USE TIE —DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION.
3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN
STAKES.
DRIPLINE BURIAL
NOT TO SCALE
Q
LL
O
II
w
J
W
cl-C) III
NOTE:
ONE VALVE PER BOX.
PROVIDE EXTRA COILS (18") OF EACH WIRE IN VALVE BOX.
COMPACT SOIL AROUND VALVE BOX.
USE TEFLON OR FLOWABLE SEALANT IN ALL THREADED FITTINGS, PER
MANUFACTURES SPEC'S.
REMOTE CONTROL VALVE ASSEMBLY
NOT TO SCALE
X
cn
w
m
O
N
N
O
N
N
E
a
0
J
I10
N
a
N
CD
CD
0
SIDE VIEW
DRIP IRRIGATION VALVE
NOT TO SCALE
PVC SCH 80 SxT 90° ELBOW
PVC SCH 80 UNION
WIRE WITH WATERPROOF
WIRE CONNECTOR - TYPICAL
FINISIH GRADE
SPARE WIRE WITH WATERPROOF
WIRE CONNECTOR ON CUT END
VALVE BOX
WITH COVER
PVC LATERAL
TO SPRINKLERS
PVC SCH 80
NIPPLE
AND FEMALE
ADAPTOR
PVC SCH 80
UNION
PVC SCH 80
NIPPLE
REMOTE CONTROL VALVE;
BODY CLEAR
OF SUMP
1 C.F. 7/8"
WASHED GRAVEL
SUMP
PVC MAINLINE
PVC SCH 80
NIPPLE
IRRIGATION DETAILS
OF
ELLIOTT FARMS
A PORTION OF SECTION 22, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
RECORD DRAWING
POP-UP
PAVING
SPRINKLER
FLUSH AT LAWN
AND FLUSH WITH
MULCH LINE
SPRINKLER
PVC SCH 80 NIPPLE
PVC LATERAL
Ell I I _--I
NOTE:
MANUFACTURER'S LIMITS PREVAIL FOR
INSTALLATION AND ADJUSTMENTS.
PROVIDE SWING JOINT RISERS AT WALKS AND CURBS.
24" FLEXIBLE RISERS ACCEPTABLE ELSEWHERE.
POP-UP RISER ASSEMBLY
NOT TO SCALE
O1 FINISH GRADE
O2 STANDARD VALVE BOX WITH COVER:
RAIN BIRD VB—STD
O3 WATERPROOF CONNECTION:
RAIN BIRD DB SERIES
VALVE ID TAG O4
O5 30—INCH LINEAR LENGTH OF WIRE, COILED
�6 1" X 3/a" REDUCING COUPLING
(INCLUDED IN XCZ—LF-100—PRF KIT)
O7 PRESSURE REGULATING FILTER:
RAIN BIRD PRF-100—RBY (INCLUDED IN
XCZ—LF-100—PRF KIT)
O8 LATERAL PIPE
O9 PVC SCH 40 FEMALE ADAPTOR OR REDUCER
10 REMOTE CONTROL VALVE:
RAIN BIRD LFV-100 (INCLUDED IN
XCZ—LF-100—PRF KIT)
11 PVC SCH 40 TEE OR ELL TO MANIFOLD
12 3—INCH MINIMUM DEPTH OF 3/4—INCH
WASHED GRAVEL
13 MANIFOLD PIPE AND FITTINGS
14 MINIMUM FOUR (4) 4"x8" BRICKS
SURVEY DATUM 7
NWRWI L wm rt mm amm
HOWWAL DAIM IS 100 IN991) PER aTY OF VERTICAL DMI FUR TI6 SIZE 6
RDIM CITY OF RENIO11 CONTROL vorlr ND. 1857 IS NAVD I= PER Cff OF
WAS HELD FOR POSITION AND A WE BOWM CITY REMM. CRY OF Ill"
OF RDITCH CONTROL PO9R ND. 1010 AND CONTROL POW NO. 2192 VMS MIS E1 Nm 18 mmm PN0.
OLAR 80 WAS NEID Fat RDr nD1t. MD FOR E�11TION.
BEIIIO SW3Y23E. 95.199 FEEt(INVD88).
TOP VIEW
RECORD DRAWING AS —BUILT
REC EQUIPMENT and MONUMENT SIGN
REVISION
6" CLEAR OF
OBSTRUCTION
MULCH CONDITION
FINISH GRADE
ADJUST ANGLE AT
SLOPE COVERAGE
CONDITIONS. 50% OF
SLOPE ANGLE - TYPICAL
MARLEX 90` ELBOWS
PVC SCH 40
TEE SxSxT
(SIDE INLET ONLY)
SURVEYED:
DESIGNED:
TCR
TCR 5.27.22 JMV DRAWN: TCR
JMV 4.19.22 JMV CHECKED:
imv
BY DATE APPR APPROVED:
JMV
FINISH GRADE
PVC DRIP MANIFOLD PIPE
PVC 1" X 3/4" TRUE UNION
BALL VALVE
EASY FIT MALE X BARB
ADAPTER:
RAIN BIRD XFF—MA-075
5O
SUB —SURFACE DRIPLINE:
RAIN
BIRD XF
SERIES
BLANK TUBING
O6
12—INCH
VALVE
BOX WITH
COVER:
RAIN
BIRD VB—STD
70
3—INCH
MINIMUM
DEPTH
OF 3/4"
WASHED
GRAVEL
Og
BRICK (1
OF 2)
FLUSH POINT WITH BALL VALVE
NOT TO SCALE
FINISH GRADE
VALVE BOX
QUICK COUPLING VALVE
SUMP 1 C.F. 7/8"
WASHED GRAVEL
THREE (3) 4"x8" BRICKS
MARLEX ELL - TYPICAL
SCH 80 P.V.C. NIPPLE
SCH 40 PVC SXSXT TEE
QUICK COUPLING VALVE DETAIL
NOT TO SCALE
O1 FINISH GRADE/TURF
2O OPERATION INDICATOR
3O SUB -SURFACE DRIPLINE:
SEE IRRIGATION SCHEDULE
NOTE:
1. INSERT BARB TRANSFER FITTING DIRECTLY INTO DRIPLINE TUBING.
2. VAN NOZZLE MAY BE SET TO CLOSED, OR IF IT IS DESIRED TO SEE SPRAY FROM
THE NOZZLE, SET THE ARC TO Y4 PATTERN. THE FLOW FROM THE NOZZLE, 0.3
GPM, SHOULD BE ACCOUNTED FOR IN THE SYSTEM DESIGN.
DRIP IRRIGATION DRIPLINE INDICATOR
NOT TO SCALE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL• NAVD 1988
HORIZONTAL HAD 1983/1991
DATUM
•
CITY OF
RENTON
Planning/Building/Public Works Dept.
V E
C
v
.,
i
c
O
�
H
3
C
4-1
8
r
m
C
�
i
LLB
CV
�
M
4A
i
a
co
N
M
01
4A
LO
i
C
LO
aS
N
/c�v
W
O
V
r
Y
N
RECORD DRAWINGS
R-4166331
10,
H
O
O
O
Q
co
IN COMPLIANCE WITH CITY OF RENTON STANDARDS cTv
TRIPOINTE HOMES
(425) 455-2900
15900 SE EASTGATE WAY. SUITE 300
BELLEVUE, WA 98008
�O
Qz
�O
I—
—)
Ow
JUJ
DATE:
LLJ
W
05-27-22
FIELDBOOK:
PAGE
33 °F 46