HomeMy WebLinkAboutR-417723FINISH GRADE SEE SHEETS C501-5A AND C501-58 DEPTH AS RECOMMENDED REMOVE AND DISPOSE OF CONCRETE PAVING AND GRADING DETAILS BY GEOTECHNICAL ENGINEER STRUCTURAL SLAB VAULT LID IN ITS PROPOSED CONCRETE (3-FOOT MIN) ENTIRETY (TYPICAL) PAVEMENT SECTION EXISTING GRADE/TOP OF VAULT C501-2E o v REMOVE AND DISPOSE OF CONCRETE STRUCTURAL WALLS TO A MINIMUM DEPTH OF 3-FEET BELOW FINISH GRADE ELEVATION OR AS REQUIRED BY GEOTECHNICAL ENGINEER (TYPICAL) BACKFILL VAULT WITH GRAVEL BACKFILL CUSS B PER WSDOT STD SPEC 9-03.12(1)B. BACKFILL SHALL BE COMPACTED TO AT LUST 95% MAX DENSITY PER ASTM D1557 (�L WET VAULT REMOVAL SECTION A C50011-2E SCALE: NITS 24" DIA MANHOLE 14" INLET FRAME AND COVER (TYPICAL) F INTERIOR WALL (TYPICAL) --------------— — — — — — — — — — — — — — ------ ----------------- ---------------- O — — — — — — — — — — — — — — r-- ----------------- I I I I O I I I I I I I I I I I I I I I I I I I I ---- AND C50011-2E FLooR Box AND OPERATOR 1a" ouTLET WATERTIGHT FRAME AND COVER - TOP SLAB AND EXTERIOR WALL CONTROL JOINT WSP "( 3330I9 AxmeX It CALL 48 HOURS 1 I 300AC w aI fe Wry, 12Kb BEFORE YOU DIG L: (2 1-DOO )431-2250 1-800-424-5555 FAX:(m FAX: (i(6) 431-E350 SYM RENSION SY APPROVED DATE CRIS APRON R - CENTRAL C180242 WEE SPT I 07/09/21 REVISION O - TOP SLAB AND EXTERIOR WALL CONTROL JOINT C BREAK UP STRUCTURAL CONCRETE VAULT FLOOR AS REQUIRED PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS (TYPICAL) BY I APPROVED I DATE 10" DIA DI OUTLET ASSEMBLY TO BE REMOVED 4 � C501-2E PLUG VALVE TO BE REMOVED — ISOLATION JOINT CONCRETE PAVEMENT #5 X 2'-6" 0 18" OC B8 09" OC #5 0 12"OC EW EF 0 c #8 0 12" OC TOP AND BOTTOM #8 09- OC J'6 0 12" ON TAR — #5 0 12" OC TOP AND BOTTOM FG EG LEGEND REMOVE AND DISPOSE OF EXISTING STRUCTURE GENERAL NOTES 12" oC 1. VAULT DEMOLITION, REMOVAL, AND DISPOSAL SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION SECTION 2-02 AND AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. SEE 2" OC GEOTECHNICAL REPORT DATED 09/07/2018. HOOKS 2. DE -WATERING SHALL BE PERFORMED IN ACCORDANCE WITH T&B CONSTRUCTION DEWATERING GENERAL NOTES ON SHEET C501-11E. n STRUCTURE REMOVAL DETAIL C501-2E SCALE: NTS WET VAULT REMOVAL SEQUENCE OIL SKIMMER TO BE REMOVED COALESCING PLATE PACK To BE REMOVED AND DI' 2" WASTE OIL LINE LEX COUPLING X TO- REDUCER (PE X PE) 1 }" BEND 14" DIA DI OUTLET PLAN 1011mo'l0oa:L\I1]11 well] IF, go] n1►1■:lI•[a%1m11ar_lII i L -BOEArw" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC 1. INSTALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES. 2. ARRANGE FOR INSPECTION WITH BOEING EHS AND TAKE VAULT OFFUNE. CONTRACTOR SHALL COORDINATE ALL STORMWATER INSPECTION AND SHUTDOWN ACTIVITIES WRH BOEING EHS. 3. DE -WATER. 4. CLEAN AND REMOVE OIL SEPARATION COMPONENTS INCLUDING COALESCING PLATES, OIL SKIMMER, SUPPORT BRACKETS, AND OUTLET PIPE. OIL SEPARATION COMPONENTS SHALL BE STORED UNDER COVER UNTIL THEY ARE REMOVED FROM THE SITE AND DISPOSED. 5. DEMOLISH AND REMOVE VAULT STRUCTURE LID. DEMOLISH AND REMOVE STRUCTURE INTERIOR AND EXTERIOR WALLS TO A MINIMUM DEPTH OF 3-FEET BELOW FINISH GRADE ELEVATION OR AS REQUIRED BY GEOTECHNICAL ENGINEER. 6. BACKHLL TO BOTTOM OF SUBGRADE. REMOVE 24" DUCTILE IRON FRAME AND LOCKING COVER (TYPICAL) REMOVE 10" DI OUTLET PIPING, OIL SKIMMER COMPONENTS, AND SUPPORT BRACKETS V REMOVE SLIDE GATES TYPICAL EACH SIDE INED WASTE OIL RESERVOIR SCALE: NITS [CIVIL PERMIT E WET VAULT REMOVAL DETAILS APRON R — CENTRAL RENTON SITE MASTER S 11 RENTON, ' R-41770231 IN COMPLIANCE WITH CITY OF RENTON STANDARDS C180242U Klb 07/09/91 ;501-2E DMP C23 C180242 RTN—YD—0501-2E