HomeMy WebLinkAboutR-417737n
n
C
LLl
094-18
SDMH TYPE 3 -
srs sTs sTS— / sJs 30" HDPE srs w srs sTs STs sTs
i
-18
SADDLE MH TYPE 3 - 72"
STOP
k
—----_—_-- __
8'F
FW FW
i
F�CW CW
8" AF PRD
HDPE
F __--OW _----FW--- FW�W--- FW FW
cr,2 _
RIM, T720
TWN 16.64 ...
200' SHORELINE SETBACK
PER CITY OF RENTON
O
O
1093-18 O
OO O soMH TYPE sa O
WSP AC
333019n A. mescum
CALL 48 HOURS
SURe3003No
fe 9B0012Kb
BEFORE YOU DIG
L: (2Wry, 1-
-800-424-5555
FAX: GM6)431-2250
FAX: (i(6) 431-E350
SYM
REVISION
EY
APPROVED
DATE
ONTO
APRON R - CENTRAL
C180242
ARAM
SET
I 07/09/21
STS
■ _ H5
1
1
•
Oil
1062-18 ------
----------•- ----- �R —
1 24" PVC DRAIN
1
1
w
_ W/ HERRINGBONE GRATE
•
1
PROVIDE 2' SUMP
1
NOT 18.35
N: 185801.06
•
�E: 1300306.89
1
IE (S) = 15.30 (12" HDPE)_
-
- All
11,,
r
•
3
;
1
1�
1
1
cwcwA cW m
1 X x
1
—cw
—----_
—
-1
II
II
• •
II
II
II
00
II
II
II
�
II
II
-IT
�
II
ORE 729-18 F71
1
it
SAFE DRAIN
RIM: 18.45
IT 185770.70
E: 1300199.18
ire
I
IE (S) - 15.44 (12°
HDPE)I
vi
I I
II
II
II
\
I II
I II
I II
I II
I II
I II
LASTS
=
I III
REVISION
BY I APPROVED I DATE
i L -BOEArw"
vo,cq3� -EL*
10 0 10 20 n /
scale feet / V
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICA➢ON IS APPROVED
APPROVED�PTTC
GENERAL
NOTES
1.
HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM,
NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL
DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29).
I
VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN
I
VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET.
I
2.
THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS,
COATINGS OR ZINC APPLIED SURFACE TREATMENTS ONANY
EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL
GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL
BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE
I
OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR
COMPLEDON OF CONSTRUCTION.
3.
PERMANENT WATER QUALITY TREATMENT FACILITIES SHALL NOT BE
I
USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER.
I
NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS
COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL
PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET
C501-1A AND C501-18.
4.
SEE PAVING AND GRADING DETAIL PLAN SHEETS C501-5A
THROUGH C501-5D FOR PAVEMENT DEFAILS AND GRADING
x
INFORMATION.
I
5.
SEE STORM DRAINAGE DETAIL PLAN SHEETS C501-68 THROUGH
I
C501-6V FOR ADDITIONAL STORM SYSTEM IMPROVEMENT DETAILS.
I
6.
SEE UTILItt DETAIL PLAN SHEETS M501-IA THROUGH M501-11)
—
FOR FIRE WATER SYSTEM IMPROVEMENT DETAIL.
1- --
7.
SEE UTILItt PLAN SHEET Al FOR DOMESTIC WATER
DETAILS.
I
8.
SEE MECHANICAL AND ELECTRICAL PLANS FOR ADDITIONAL
I
I
INFORMATION.
N
n
RE
SAFE DRAIN PER DETAIL 1 ON SHEET C501-6V
C
r
Z
Gi ® PIPE CROSSING. SEE SHEET C501-613 FOR PIPE CROSSING TABLE.
O
EDO CONSTRUCTION NOTES
/ li--�:> PROVIDE 24" PVC DRAIN BASIN WITH HERRINGBONE GRATE
C
C
CD
Z
ODD
CIO
C11
C12
C13
C14
C15
C16
C17
CIB
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
[CIVIL PERMIT
E
STORM DETAILS
APRON R — CENTRAL
RENTON SITE
MASTER ' 11 RENTON,'
KEY PLAN
SME : NONE
RR-41770371 IN COMPLIANCE WITH CITY OF RENTON STANDARDS
H180242UKlli 07/09/21
;501-6A C37
COMP
C 180242
RTN—YD—0501-6A