HomeMy WebLinkAboutR-417750112m TOP OF SLOT SHALL BE DEPRESSED 1/2" BELOW SURROUNDING PAVEMENT I I �1 3/ CONSTRUCTION JOINT (TYR) SEE 1 DETAIL 4 ON SHEET C501-5D- CONCRETE PAVING AS SHOWN ON PAVING PLANS (TYR) SEE NOTES - NOTES: 1. SLOTTED DRAIN ASSEMBLY SHALL BE RANCOR DURASLOT, OR APPROVED EQUAL. SLOTTED DRAIN AND TRENCH SHALL MEET AIRPORT LOAD RATING REQUIREMENTS. MANUFACTURER SHALL PROVIDE STAMPED SUBMITTAL DRAWINGS PRIOR TO MATERIAL ACCEPTANCE. INSTALLATION SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. 2. HIGH SLUMP CONCRETE SHALL HAVE MINIMUM 1000 PSI 28-DAY COMPRESSIVE STRENGTH. 3. CONCRETE PAVEMENT ABOVE SLOTTED DRAIN TRENCH SHALL MATCH PAVEMENT REQUIREMENTS SHOWN ON THE PAVING PLANS. IF REINFORCEMENT IS SHOWN ON THE PAVEMENT PLANS, IT SHALL BE CONTINUED ACROSS SLOTTED DRAIN TRENCH. 4. SLOTTED DRAIN PIPE SHALL BE HIGH DENSITY POLYETHYLENE OR ALUMINIZED STEEL TYPE 2. PIPE WALL THICKNESS AND GAUGE SHALL BE AS REQUIRED TO MEET AIRPORT LOADING REQUIREMENTS. PIPE MATERIAL SHALL HAVE A MAXIMUM MANNING COEFFICIENT OF 0,024, FINAL CONFIGURATION OF SLOTTED DRAIN ASSEMBLY AND TRENCH SHALL MEET THE DIMENSIONS SHOWN BASED ON SELECTED PIPE MATERIAL AND SLOT DIMENSIONS. 5. ALL METAL PARTS USED IN SLOT DRAIN ASSEMBLY INCLUDING PIPE, SLOT, COUPLING BANDS, AND FIRINGS SHALL BE NON GALVANIZED ALUMINIUM, STAINLESS STEEL, ALUMINIZED STEEL, OR PLASTIC. ADS DURASLOT DRAIN B" HDPE DUAL WALL PIPE WITH 15" SLOT. INSTALL PER MANUFACTURERS RECOMMENDATIONS. HIGH SLUMP CONCRETE SEE NOTE 2 ELEVATION AS SHOWN ON GRADING PLANS (TYP) PAVEMENT SLOPED AS SHOWN 15" ACTUAL ON GRADING PLANS (TYR) SLOT HEIGHT T2% _ I 12% �18 -12" ' 30" #5 EPDXY COATED '/' �' a REBAR, 18" O.C. TYR #4 EPDXY COATED Q RERAR, 12" O.C. (TYR) `HIGH SLUMP CONCRETE 3 w oa SUB -BASE MATERIAL M SEE NOTE 2 AS SHOWN ON m n 8° OR AS SHOWN ON PAVING PLANS (TYR) o z PLANS . SEE NOTES E = o 1 PIPE INVERT ELEVATION AS SHOWN ON PLANS 8" SLOTTED DRAIN SECTION C501-61) SCALE: NTS CAST IRON CAP WITH RUBBER GASKET — CONCRETE PAVING AS SUB -BASE MATERIAL SHOWN ON PAVING PLANS AS SHOWN ON PAVING PANS ( F I 2 1 CATCH BASIN " SLOTTED DRAIN CONNECTION T WSP AC 3330I9 AxmeSe S 300 CALL 48 HOURS fe L: aI (2Wry, 1- 9B0012Kb LEI:( BEFORE YOU DIG 0 )31-z300 1-800424-5555 FAX: (zas) 43I-2250 SYM 1 RENSION BY APPROVED DATE SYM REVISION ORIG I APRON R - CENTRAL C180242 I WSP I SPT 07/09/21 fG+ IoA C50, 1 6� BY I APPROVED I DATE NOTE: 1. BASINS SHALL BE NYLOPLAST PVC DRAINS OR APPROVED EQUAL AND SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 2. CONTRACTOR SHALL FOLLOW MANUFACTURERS RECOMMENDATIONS FOR BACKFIWNG WITH CDF DURING INSTALLATION. 3. DRAIN BASINS SHALL BE CUSTOM MANUFACTURED ACCORDING TO PLAN AND PROFILE INFORMATION. RISERS ARE NEEDED FOR BASINS OVER 84-INCHES DUE TO SHIPPING RESTRICTIONS. THE MAXIMUM DEPTH FROM FINISHED GRADE TO THE LOWEST INVERT SHALL BE 8-FEET. 4. DRAINAGE CONNECTIONS SHALL UTILIZE FLEXIBLE ELASTOMETRIC SEALS CONFORMING TO ASTM F477 AND SHALL MEET THE REQUIREMENTS OF ASTM D3212. CONNECTIONS SHALL BE MADE PER MANUFACTURER'S RECOMMENDATION. CONNECTION ADAPTERS SHALL BE AS REQUIRED TO ACCOMMODATE PIPE TYPE AND DIAMETER SPECIFIED ON PLANS. 5. FRAME AND GRATE OR COVER SHALL BE RATED TO MEET THE PROJECT LOADING REQUIREMENTS ON SHEET G3. DUCTILE IRON FRAME SHALL BE CAST INTO AND FULLY SUPPORTED BY CONCRETE COLLAR. CARE SHALL BE TAKEN TO ENSURE NO LOAD WILL BE TRANSFER TO THE PVC BASIN. 6. FRAME AND COVER FOR 30-INCH DRAIN WITH LOCKING LID SHALL BE NEENAH FOUNDRY PRODUCT NUMBER R-3492-A OR ENGINEER APPROVED EQUAL. FRAME AND GRATE FOR 24-INCH DRAIN WITH HERRINGBONE GRATE SHALL BE NYLOPLAST 24"0 X 24" SQUARE BASEPLATE AND EAST JORDAN IRON WORK 24N20" RECTANGLE GRATE PRODUCT 00775035B01. 7. ALL BACKFILL SHALL BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY PER ASTM 0-1557. 8. IF SUBGRADE IS DETERMINED BY THE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO BE UNSUITABLE, PROVIDE GEOTEXTILE FABRIC FOR SUBGRADE STABILIZATION AS DIRECTED BY THE BOEING CONSTRUCTION MANAGER PER THE CEOTECHNICAL ENGINEER'S RECOMMENDATIONS. 9. HIGH SLUMP CONCRETE SHALL HAVE MINIMUM 1000 PSI 28-DAY COMPRESSIVE STRENGTH AND SHALL EXTEND TO 12-INCHES BELOW BOTTOM OF CONCRETE PAVEMENT OR THE BELL OF THE UPPERMOST PIPE CONNECTION. 10. CONCRETE PAVEMENT SHALL MATCH PAVEMENT REQUIREMENTS SHOWN ON THE PAVING PLANS. 11. SEE GENERAL NOTES ON C501-18 FOR ADDITIONAL DESIGN REQUIREMENTS. CEMENT CEMENT CONCRETE CONCRETE PAVEMENT 10' MODIHED CONCRETE PAVEMENT COLLAR PER DETAIL MINIMUM PIPE AIRCRAFT RATED FRAME COVER 27-INCHES AND GRATE, SEE NOTES a2 n -� 12• SEE NOTES r - J THIGH SLUMP \� CONCRETE LELEEVAl FULL WIDTH OF TRENCH (18" MIN) Z//X ,. / /CSBC/ / ' - QUARRY N NYLOPLAST PVC DRAIN BASIN C501-6A SCALE: INTO C501-6B CAST IRON •- d a d d. A d PCCP SECTION d < a r d a d. e CSBC a. z MONITOR WELL INSTALLATION PLAN - SCALE: NITS i L_BOEArw" NATIVE SOIL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC CAST IRON CAP WITH RUBBER CASKET BOLTED TO FLANGE LOCKABLE 4 ?6} WATERPROOF _ CAP y IMPERVIOUS GROUT APRON R FINISHED GRADE STEEL RUBBER STEEL VAULT PVC WELL CASING SUMP DEPTH SHALL BE MINIMAL ALLOWABLE DEPTH PER MANUFACTURER UNLESS OTHERWISE NOTED ON PLAN LOCKABLE WATERPROOF CAP 1SSEMBLY PADLOCK ATE WELL CASING NOTES: SECTION B 1. MONITORING WELL INSTALLATION SHALL BE PERFORMED BY BOEING APPROVED CONTRACTOR AND ALL WORK SHALL BE COORDINATED WITH BOEING ENVIRONMENTAL. 2. MONITORING WELL LOCATIONS SHALL BE FIELD ADJUSTED AS DIRECTED BY 300% R-4177050 IN COMPLIANCE WITH CITY OF RENTON STANDARDS [CIVIL PERMIT E STORM DETAILS APRON R - CENTRAL RENTON SITE MASTER S 11 RENTON,' C180242 U K l; 07/09/91 'F501-61P C50 COMP o C 180242 RTN-YD-0501-6P