HomeMy WebLinkAboutR-417751SITE SPECIFIC DATA PROJECT NUMBER 7606 PROJECT NAME BOEING M!T/GARON HANGAR PROJECT LOC477ON RENTON, WA SMW7URE lD M-17 TREATMENT REQUIRED VOLUME 541 (CF) FLOW BASED (CFS) •0.409 TREATMENT HGL AVAILABLE (FT) N/A PEAK BYPASS REOU/RED (CIS) - IF APPL/C46LE 2.176 PIPE DATA LE AM7FRUL DIAMETER INLET PIPE 16.67 HDPE /1' OUI£T PIPE 15.20 HOPE 12' PRE/REI7MLNT B/OFXTRA7KW DISCHARGE RIM ELEVATION 19.65 19.55 19.65 SURFACE LOW 120 KIPS 120 KIPS 120 KIPS FRAME A, COVER 36' X 36; 36' X 74' (2) 36' X 74 s (2) J6' X 36' (2) 30' X 30' INDUSTRIAL MED14 VOLUME (CY) 4.48 INDUSTPoAL MED14 DELIVERY MEVII00 PER CONTRACT ORIFICE SIZE (OJA INCHES) 2 FA 01.99' NOTES *A TOTAL OF TWO MWS UN17S WILL PROVIDE 7H£ REWIRED 7REA7MENT ROW. INSTALLATION NOTES 1. CONTRACTOR 70 PROVIDE ALL LABOR, EQUIPMENT, M47EI AND INCIDENTALS REWIRED TO OFFLOAD AND INSTALL THE SYS7EM AND J APPUR7EMACES IN ACCORBINCE WIN THIS DRAWING AND THE MANUFACTURERS SPECIRCATOAS UNLESS OTHERWISE STATED IN MANUFACTURERS CON7R4CT. 2 UNIT MUST BE INSTALLED ON LEVEL RISE. MANUFACTURER -� RECOMMENDS A MINIMUM 6' LEVEL ROCK BASE UNLESS SPECIFIED BY 7HE PROJECT ENGINEER. CONTRACTOR AS RESPONSIBLE TO VERIFY PROJECT ENGINEERS RECOMMENDED BASE SPECIPIC4IONS J. ALL PIPES MUST BE FLUSH W17H INSIDE SURFACE OF CONCRETE. (PIPES CANNOT IWRIJUE BEYOND RUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH NTH DISCHARGE CHAMBER F106R. ALL GAPS AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON -SHRINK GROUT PER MANUFACTURERS STANDARD CONNEC7ION DETAIL AND SHALL MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS. 4. CONTRAC70R 70 SUPPLY AND INSTALL ALL EXTERNAL CONNECTOG PIPES 5. C0N7R4C7OR RESPONSIBLE FOR IASTALUBON OF ALL RISERS, AIANWLES, AND HATCHES CON7RAC7OR 70 GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 6. DRIP OR SPRAY /AWTION REWIRED ON ALL UNITS W77H VEGETATION. r_VMCDAi NlnTCC 1. MANUFACTURER TD PROVIDE ALL M4TFR4LS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS B"AT/ONS, SPECIRC4706 AND CAPACITIES ARE SUBJECT 70 CHANGE. FOR PROJECT SPECIFIC DPAWNGS DETAILING EXACT DIMENSIONS, KOO AND ACCESSORIES PLEASE CONTACT MANUFACTURER. WSP 0AC 3330I9 e X tl CALL 48 HOURS wRe303DD fe Wry, 12Kb BEFORE YOU DIG L: (2 1-DOO )431-2250 1-QDB-A2A-.>JrJ.> FAX:(m FAX: (i(6)431-E350 SYM RENSION BY APPROVED DATE ORIG APRON R - CENTRAL C180242 WSP SPT I 07/09/21 � �- L,.ry,�.rn baborm � 11 El _ o I i J 0111710W FIFE ORl/V OOMN [ME PRE-FlUER SEE N07ES NEENUI FONNDRY NED14N FOUNDRY C4RTRIDGE RJ4W-RJS SPRING R-349R-R2S SARM ASSIST H4700 Asas7 /t47CN aWtow FIFE SEE NO2S PLAN VIEW 25' 0' ELEVATION VIEW INTERNAL BYPASS DISCLOSURE: THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD N BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK ROW SHALL BE ASSESSED 70 ENSURE ND UPSTREAM FLOODING. PEAR FILL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. -6C REVISION BY I APPROVED I DATE rJ- LEFT END VIEW NEDHN FOUNDRY R-34RB-R2S SPOW ASS5Tm W R/DNT END VIEW i L -BOEArw" AEDWl fWNORY R-3/RR-RJS SPRMC ASSIST MTCW ^i ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC LEGEND/QUADRANT CODE DESCRIPTION I SIZE PIPE SIZE I II 11 UTILITY WATER, GAS,ETC III MATERIAL CAST IRON, PVC, ETC IV DEPTH DISTANCE IN FEET 12" HPW TO TOP OF UTILITY MATERIALS ABBREVIATION: CL DI 4'-6" CAST IRON PIPE OF CORRUGATED METAL PIPE CMP III IV COMPOSIT PIPE CP POLYMNYL CHLORIDE PVC REINFORCED CONCRETE PIPE RCP GALVANIZED STEEL CS STEEL PIPE SP EXISTING OR VITRIFIED CLAY PIPE VCR FINAL PAVEMENT 3" BRASS MARKER ALUMINUM AL W/ ANCHORING PIN DUCTILE IRON CI COPPER OLD DURIRON DUE POLYPROPYLENE PP HIGH DENSITY POLYPROPYLENE HDPP a ADD THE FOLLOWING IN APPROPRIATE CASES: DRILL 4* DIAMETER HOLE CONCRETE ENCASED CONIC a- DOUBLE CONTAINED PIPE DOE < FIRE PROTECTION FP A 4 CEMENT LINED CL - - INSULATED INS NON -SHRINK GROUT IN EXISTING PAVEMENT OR SET MARKER IN NEW CONCRETE PAVEMENT BOEING RENTON FACILITIES MECHANICAL PIPING STANDARD SECTION D38106-502 NOTES: 1. ARROWS INDICATE DIRECTION(S OF UTILITY WITH DISTANCES IN FEET, TO AND FROM ADJACENT MARKER S) OR UTILITY STUB-UP(S). 2. LETTERING SHALL BE STAMPED 1/4" BLOCK STYLE LETTERS, ALL NEW AND EXISTING (UNCOVERED AT POINT OF EXCAVATION) UNDERGROUND UTILITIES SHALL BE MARKED PER THE ABOVE REQUIREMENTS. 3. MARKERS SHALL BE A 3" FLAT BRASS OR ALUMINUM SURVEY MARKER. 4. SEE PROJECT LEGEND FOR PIPING CONTENTS ABBREVIATIONS. USE THE ABOVE TABLE FOR PIPING MATERIALS. 5, MARKERS SHALL BE LOCATED AT MAXIMUM INTERVALS OF 150 FEET, AT CHANGES OF DIRECTION, WITHIN 5 FEET OF A WALL, AT ALL MANHOLES AND VALVE BOXES, AND ADJACENT TO ROADS. MARKERS SHOULD INDICATE SERVICE, PIPE SIZE, DIRECTION OF FLOW, PIPE MATERIAL AND PIPE DEPTH. 6. MARKER INSTALLATION LOCATIONS SHALL BE INDICATED ON THE CONTRACTOR'S PROVIDED AS -BUILT INFORMATION IN THE FORM OF RED -MARKED DRAWING. AIRCRAFT RATED HATCHES 72° X 36° DOUBLE NEENAH R-3498-R35 fit' X 36' DOUBLE EAST JOURDAN 8196-DOUBLE 36" X 36" SINGLE NEENAH R-3498-132S 24" DIA ROUND NEENAH R-3492 NOTES: 1. ALL VAULT STRUCTURES AND ASSOCIATED ACCESS LIDS AND HATCHES SHALL MEET THE DESIGN LOADING REQUIREMENTS SHOWN ON SHEET C501-11 2. THE LIFTING FORCE REQUIRED TO OPEN ACCESS LIDS AND HATCHES SHALL BE A MAXIMUM OF 35-POUNDS. HINGED LIDS AND ACCESS HATCHES SHALL BE EQUIPPED WITH A HYDRAULIC LIFT ASSIST SYSTEM AS REQUIRED TO MEET THE MAXIMUM LIFTING FORCE REQUIREMENTS. 3. MODULAR WETLAND FRAMES, HATCHES, AND LIDS SHALL BE AS SHOWN IN THE TABLE ABOVE OR ENGINEER APPROVED EQUAL. 4. SEE 501-5C FOR LID ELEVATIONS. 5. PERMANENT WATER QUALITY TREATMENT FACEITIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET C501-1B. 6. SEE STRUCTURAL PLANS FOR STRUCTURAL SUPPORT DETAIL [CIVIL PER STORM DETAILS R-4177051 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEWWPMEW EMINE n NO C180242 C501-6Q 07/09/21 RENTON SITE MASTER S 11 0, C180242 ICOMF I0, RTN-YD-0501-6Q