HomeMy WebLinkAboutR-41775330" MAINTENANCE ACCESS W/IADDER- 30" SQUARE SAMPLING AND INSPECTION ACCESS- 8" SEE NOTES 9.0' MIN 8" SEE 7.0' MIN 8" SEE NOTES I �� I I I _L1-- I -J_L 7 I I 30" SQUARE SAMPLING AND INSPECTION ACCESS NLET WEIR I� J I I ryc� \ I_J- -J - ----------L1----- I 24" MAINTENANCE / 1.4 36" X 72" ACCESS FOR ACCESS W/LADDER_ 12" PLATE PACK REMOVAL 48" 0 RISER PVC UTLET TO RTU-01O6 - 1� Q J 18' HDPE HIGH FLOG BYPASS OUTLET ROWS-067 PLAN VIEW SHUT OFF 36" X 72"ACCESS FOR o i PLATE PACK REMOVAL PAC o ii 30" SAMPLING AND z 5 N z INSPECTION ACCES COALESCING PLATE PACK a HOLD-DOWNS SECURED 0 30" MAINTENANCE m TO VAULT, SEE NOTES 30" SAMPLING AND gCCE55 W/LADDER INSPECTION ACCESS c OF OUTLET m INLET TEE 18.35 4 C 12" OUTLET s WQ-SURFACE Q-- - WQ SURFACE Q- EL- 17.11 BE -- - - EL- 17.11 6" PVC TEE z ITMOUTLET INLET EL 15.75 SNLET L 1 .75 ADDER 1 a.. _ NLEf WEIR � z o 18" INLET PIPE C a EL - 13.11 b = LANGE WIDTH SHEAR GATE SECURED IN OPEN POSITION n Z o � OIL RETENTION BAFFLE/CONC COALESCING PLATE PACK,J SEE NOTES ( ) ROWS-067 SECTION 1 WSP "( 3330I9 e X tl CALL 48 HOURS 1 I 300AC eall fetl: 12Kb fi Wry, BEFORE YOU DIG ( 1-DOO )431-2250 -806-424-5555 FAX:(m FAX: (i(6) 431-E350 SYM RENSION EY APPROVED DATE ORIG APRON R - CENTRAL C180242 WEE SET I 07/09/21 REVISION 30" SAMPLING AND INSPECTION ACCESS �30" MAINTENANCE ACCESS W/LADDER P8"ET 14 EL - 18.35 SEE NOTES TOP OF RISER EL - 17.85 ISER TEE HOLD-DOWN @ SUPPORTS SECURED TO VAULT, SEE NOTES 18" BYPASS OUTLET EL TL 13.63 71 48" 0 RISER WITH SOLID BOTTOM onnnu ri - 11 u NOTES 1. SEE GENERAL NOTES ON THIS SHEET. 2. DESIGN WATER QUALITY FLOWRATE: 1.448 CFS 3. DESIGN PEAK 100-YR BYPASS FLOWRATE: 4.933 CPS BY I APPROVED I DATE i L -BOEArw" GENERAL BYPASS/OWS NOTES 1. ALL DIMENSIONS SHOWN REPRESENT INTERIOR OF CONCRETE LINED STEEL STRUCTURE. SEE STRUCTURAL DETAILS FOR STRUCTURAL DESIGN AND REINFORCEMENT INFORMATION. 2. PIPE AND COALESCING PLATE PACK SUPPORT/HOLD DOWN SHALL BE ALUMINUM OR STEEL AND BE ANCHORED AT A MAXIMUM SPACING OF W. ATTACH PIPE SUPPORTS TO STRUCTURE WITH 5/8-INCH STAINLESS STEEL EXPANSION BOLTS OR EMBED THE SUPPORTS INTO THE STRUCTURE WALL. 3. THE RISERS AND TEES SHALL BE FABRICATED FROM ONE OF THE FOLLOWING MATERIALS: 0.060" CORRUGATED ALUMINUM ALLOY DRAIN PIPE 0.064" CORRUGATED ALUMINIZED STEEL DRAIN PIPE 0.060" ALUMINUM ALLOY FLAT SHEET, IN ACCORDANCE WITH ASTM B 209. 5052 H32 OR EPS 4. FRAMES AND LADDERS OR STEPS ARE TO BE OFFSET SO THAT: THE SHEAR GATE IS VISIBLE FROM THE TOP AND THE CLIMB -DOWN SPACE IS CLEAR OF THE RISER AND GATE. 5. RESTRICTION PLATE ORIFICE OPENING IS TO BE CUT ROUND AND SMOOTH. 6. THE SHEAR GATE SHALL BE MADE OF ALUMINUM ALLOY IN ACCORDANCE WITH ASTM B 26 AND ASTM B 275, DESIGNATION ZG32A; OR CAST IRON IN ACCORDANCE WITH ASTM A 48, CLASS 308. THE LIFT HANDLE SHALL BE MADE OF A SIMILAR METAL TO THE GATE (TO PREVENT GALVANIC CORROSION), IT MAY BE OF SOLID ROD OR HOLLOW TUBING, WITH ADJUSTABLE HOOK AS REQUIRED. A NEOPRENE RUBBER GASKET IS REQUIRED BETWEEN THE RESTRICTOR PLATE MOUNTING FLANGE AND THE GATE FLANGE. INSTALL THE GATE SO THAT THE LEVEL -LINE MARK IS LEVEL WHEN THE GATE IS OPEN, THE MATING SURFACES OF THE LID AND THE BODY SHALL BE MACHINED FOR PROPER ITT. ALL SHEAR GATE BOLTS SHALL BE STAINLESS STEEL. 7. THE SHEAR GATE MAXIMUM OPENING SHALL BE CONTROLLED BY LIMITED HINGE MOVEMENT, A STOP TAB, OR SOME OTHER DEVICE. 8. ALTERNATIVE SHEAR GATE DESIGNS ARE ACCEPTABLE IF MATERIAL SPECIFICATIONS ARE MET AND FLANGE BOLT PATTERN MATCHES. 9. COALESCING PLATE SHALL BE MADE OF STAINLESS STEEL OR POLYPROPYLENE AND SHALL BE SECURELY BUNDLED IN PACKS SO THAT THEY CAN BE REMOVED AS UNITS. PLATES WITHIN EACH PACK SHALL BE INCLINED AT 454 TO 604 FROM THE HORIZONTAL, HAVE A MINIMUM SPACING OF 1/2-INCH AND HAVE CORRUGATIONS. THE PLATE PACK SHALL HAVE A MINIMUM OF 6-INCHES OF SEPARATION FROM THE BOTTOM OF THE VAULT AND 1-FOOT OF CLEARANCE FROM THE TOP OF THE PLATE PACK TO THE BOTTOM OF THE VAULT LID. 10. THE ENTIRE SPACE BETWEEN THE SIDES OF THE PLATE PACK(S) AND THE INTERIOR VAULT WALL SHALL BE FILLED WITH A SINGLE PIECE OF REMOVABLE POLYETHYLENE FOAM TO PREVENT SHORT-CIRCUITING OF THE PLATE PACK(S). 11. MANUFACTURER SHALL PROVIDE CALCULATIONS CONFIRMING THE PLATE PACK MEET THE DESIGN REQUIREMENTS OF THE 2017 CITY OF RENTON STORMWATER DESIGN MANUAL BASED ON THE FOLLOWING INFLUENT AND EFFLUENT CRITERIA: OIL SPECIFIC GRAVITY 0.88 OPERATING TEMPERATURE 50' INFLUENT OIL CONCENTRATION 100 PPM MEAN OIL DROPLET SIZE 130 MICRONS OIL RISE RATE 0.033 FT/MIN FLOW RATE SEE DETAIL WQ FLOW EFFLUENT OIL CONCENTRATION 10 PPM 100% SIZE COLLECTED 60 MICRONS 12. ALL INTERIOR VAULT BAFFLES AND WEIRS SHALL BE CONCRETE OR STAINLESS STEEL AND SHALL BE SECURELY FASTENED TO THE VAULT. PAINTING OR OTHER COATING OF METAL PARTS FOR CORROSION RESISTANCE IS NOT ALLOWED. 13. LIDS SHALL MEET LOADING AND LIFT REQUIREMENTS SHOWN ON SHEET C501-1D. 14, LINK -SEAL MODULAR SEALS SHALL BE PROVIDED AT EXTERIOR WALL PENETRATIONS AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. SEE STRUCTURAL PLANS FOR ADDITIONAL WALL PENETRATION DETAILS. 15. PERMANENT WATER QUALITY TREATMENT FACIUIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFUNE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET C501-18. 16, SEE STRUCTURAL SHEETS SS01 THROUGH SS07 FOR VAULT STRUCTURE DETAILS. [CIVIL PER ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ADM STORM DETAILS SPT K 07 09 21 JDM 07 09 21 APRON R - CENTRAL RENTON SITE CIVIL MASTER S APPROVED BT DEPT. DATE CHECKED APPRDVED WPHUVED R-4177053� IN COMPLIANCE WITH CITY OF RENTON STANDARDS 08/25/2021 CT802421 U KI61 07/09/21 101-6S C180242 1 COME RTN-YD-0501-6S