Loading...
HomeMy WebLinkAboutR-417755INLET PIPE k— (T) SAFE DRAIN VAULT ELEVATION C501-6V SCALE: NITS ]n]vn AHolnHS 2" RRRIImarT.a;ll I III➢ N i �+ II:LTII�,Ins �41I1a; D;.;ssTua.�;o�i:aa�•�A.a_1as:lau°ISY4.a; CD VALVE SAFE DRAIN VAULT PLAN 53 C505�V TEXT 4" HIGH, BLACK � A C Q z 12" WIDE YELLOW TRAFFIC COLLAR J PRECAST VAULT 1. VAULT IS TO BE AIRPLANE RATED PER LOADS ON SHEEP C501-ID. 2. LID NEEDS TO BE AIRCRAFT RATED WITH LIFT ASSIST. NEENAH FRAME AND GRATE ASSEMBLY R-3498-R2G5, OR EQUIVALENT. 3. SHALLOW GROUND WATER (APPROX 4.5' OR SHALLOWER PER GEOTECH REPORT). 4. VAULT SUPPORT SHALL BE PER STRUCTURAL SHEET sso7. SAFE DRAIN ISOLATION OPERATION SAFE DRAIN VAULT ELEVATION C501-6V SCALE: NITS 1. THE SAFE DRAIN CATCH BASIN AFT OF THE AIRCRAFT MAIN GEAR H45 SURFACE GRADING DRAINING TO THE GRATE. 2. DURING THE SAFE DRAIN VALVE INSTALLATION, ENSURE THE SAFE DRAIN CLOSING WHEEL IS ALIGNED DIRECTLY UNDERNEATH A HOLE IN THE GRATE ABOVE. THE SAFE DRAIN TOOL SHALL BE ABLE TO REACH THE CLOSING WHEEL WHILE THE GRATE IS CLOSED. 3. THE SAFE DRAIN BUTTERFLY VALVE IS VISIBLE THROUGH THE GRATE. IF THE BUTTERFLY VALVE DISC IS VERTICAL THE VALVE IS OPEN. IF THE VALVE DISC IS HORIZONTAL THE VALVE IS CLOSED. 4. THE SAFE DRAIN VALVE IS NORMALLY OPEN TO PASS STORMWATER RUNOFF. 5. THE SAFE DRAIN VALVE MAY BE OPERATED BY OPENING THE GRATE AND TURNING THE HAND WHEEL. ALTERNATIVELY THE VALVE KEY CAN BE INSERTED THROUGH THE GRATE, PLACED UPON THE VALVE NUT AND TURNED. 6. SPILL STORAGE CAPACITY WITHIN THE SAFE GRAIN IS APPROXIMATELY 120 GALLONS. 7. DEFAULT POSITION: THE SAFE DRAIN VALVES LEFT OPEN AND MANUALLY CLOSED IN THE EVENT OF A SPILL. 8. THE SAFE DRAIN CATCH BASIN IS NOT ELECTRONICALLY MONITORED. IN THE EVENT OF A SPILL REPORT AS REQUIRED AND HAVE THE SAFE DRAIN CATCH BASIN EVACUATED OF ACCUMULATED CONTAMINANTS. (2) TYPE 'SA' HINGES ' T ,r•�I +( lip �IW TI� Imfligfimlffrl I,�,+mllli� I GRADE vcmiarro (M SAFE DRAT INSERT ° a VALVE WHEEL FLUSH MOUNT VALVE AND FILTER TD-1 SAFE DRAIN BASIN 4 3/16° L 1 (3) 7/8" DID. HOLE FOR ADJUSTABIOTY (TTP. 2 PLACES) I U I FRAME AND u0 BOLTED — w/ (2) 7/2' S.S. HEX. H0. D CAP SCREW AND WASHER I fJtE � I I � I [---�ummn-,•oamwr co reOr--asA---- II -- �Irj TAND-CLEAR Y1�POF5�7PE --j' 1 /2° [73mm] HIGH ENGRAVED LETTERS 'a 3/4"� ON A FLAT AREA W/ NO PERMAGRIP — az' x az° '30 35" % 36° �1 T MOUNT VALVE AND FILTER _... E DRAIN BASIN L SAFE DRAIN BASINS SHALL BE SAFE DRAIN MODEL TD-1 FITTED WITH FLUSH MOUNTED BUTTERFLY VALVES AND INSTALLED PER THE CONTRACTORS RECOMMENDATIONS. 2. VALVE GASKET MATERIAL SHALL BE ETHYLENE PROPYLENE (EPDM) OR APPROVED EQUAL. 3. BASIN STEEL SHALL BE STAINLESS STEEL. SAFE DRAIN BASIN DETAIL NJ WI I I I I I I SAFETY SPRING ASSIST PER NF-T994 (SHOWN IN WOUND POSITION) ARM J (ENGAGED) SPRING ASSIST PER NF-T994 STAINLESS STEEL 17-7 (SHOW IN UNWOUND POSITION) (i) HOLD DOWN LATCH -DUCTILE IRON SEE DRAWING NF-T960 FOR LATCH DETAILS (1) HOLD DOWN LATCH RELEASE LEVER (HIX. HD. DEEP SOCKET MELDED TO FREE OPEN AREA IS 3.0 SO. FT. FAB. STEEL T-HANDLE PER NF-7966) NOTE: CONFORMS TO MINIMUM 100,000-POUND LOADS PER FAA ADVISORY CIRCULAR AC 150/5320-6D APPENDIX 3 ITEM 2.D.(1). (ACTUAL PROOF LOAD IS 185,000-POUND ON A 9" % 9" CONTACT AREA.) MEETS FASTENING REQUIREMENT PER FAA ADVISORY CIRCULAR AC 150/5370-10A KITS INCLUDED IN THIS urvlT �- COMPONENT N0.'S: FRAME 3498-2238, GRATE 3498-3136 1 X 81710 - SAFETY ARM MATERIAL: FRAME -CAST GRAY IRON ASTM A-48, CLASS 358 1 X 81990 -LATCH KIT 2 X 91556 -BOLTING KIT GRATE -CAST DUCTILE IRON ASTM A536, 55 + KSI. 1 X 81981 -SPRINGS KIT FINISH: NO PAINT PER FAA ADVISORY CIRCULAR AC 150/5370-10A HEIGHT: FRAME 207C GRATE APPROX. 415$ SPRING ASSIST ASSEMBLY APPROX. 54W PERMIT DATE ACCEPTABILITY NEENAH FOUNDRY FRAME AND GRATE — R-3498—R2GS � SAFE DRAIN, VAULT, AND GRATE DETAILS SCALE: Nrs R-4177055 C501-6A SCALE: NTS IN COMPLIANCE WITH CITY OF RENTON STANDARDS WSP US4AC 1 3voi w+A.reme w,m C501-6B CALL 48 HOURS wDRAWN DATE M300 C I V I L fetlerel w.y, wA seoou5m C501-6C BEFORE YOU DIG TEL: fzo57 <Bl-znao 1-800-424-5555 FAX: (za5)4az-zzso SYM RENSION BY APPROVED DALE SVM REVISION BY APPROVED M1E SUBIIRE CURREM RMSION SVMBOI JDM 07 09 21 STORM DETAILS ctEim42 OR�'i 07/09/21 ORIG APRON R - CENTRAL C780242 WSP SPT 07/09/21 �¢N ?T THIS DESIGN AND/OR H K W SPECIFICATION IS APPROVED SPT 07 09 21 Sr EET LBOE//V6® APPROVED BY DEPT. DATE JDM 07 09 21 APRON R °ENTRAL CHECKED C501-6V C55 Coa APPROVED RENTON SITE 'OR NO, ct eoz42 COMP ND. NA` APPROVED DWG N0. �\� CIVIL MASTER `, II RENTON, WA RTN-YD-0501-6V