Loading...
HomeMy WebLinkAboutR-417773I 4 I I N: 165802.45 1 • • I E: 1300182.02 3 I 2 I N: 17.61 1 I E 1300 00175.28 I J I w cw�---------- • • v N I �' • • m I �_-___--�_________-_-_- - _-- ---- ^-------------------------------- RS 1 N: 185780.50 N: 185777.27 E: 1300196.49 1 I I E 1300187.68 I 1 7.7 1 L---------------------------------------------- BOLLARD LAYOUT 6Q AT HARDSTAND R5 �1 jA M50 SCALE: 1"=10, Q 1 ______________ III I I 1 5687. 181880 I I I E: 1300288.10 I 1 � I II•� I 1 3 II I I I 4 • III• I I 111 I I JI I j ®• 0- I o--J 1 � v• •I. I I 1 1 7.7' • I I II 1 I • �I I I I I I II I 1 i 1 M 185658.75 • 1 1 E: 1300287.61 I I 1 I I II DETECTABLE SEE PAVING PLANS NS WAR NING TAPE. 6" MIN ABOVE CROWN (TYP.) TRENCH BACKFlLL SHALL BE SEE WSDOT STANDARD SPEC. 9-29.1(6) CSBC PER WSDOT STD SPEC 9-03.9(3) as ° a a - a -a a a< 1' 525 BE 1' 1' 1' SEE NOTE 5 BELOW 'S" MIN. (� ® DIAM LP OF - . 6 MIN. < UTILITIES .3" AIR PIPE BEDDING -SEE MECHANICN_ PUNS FOR SIZE -TYP. OF ALL UTILITIES PER WSO -IN ALL LOCATIONS STD SPEC 9-03.12(3) -I i i i i i i I I I I I I I 3 - 4" POWER + 1 - 4" SPARE 3 - 3" COMM SEE NOTE 5 BELOW NOTES: 1. ALL BACKFlLL MATERIAL SHALL BE PLACED IN LOOSE LAYERS OF NOT MORE THAN C DEPTH AND COMPACTED TO AT LEAST 95% OF MAX. DENSITY PER ASTM D1557. 2. FOR ADDITIONAL REQUIREMENTS SEE THE GENERAL NOTES ON SHEET C501-11E. 3. IF TRENCH SUBGRADE IS DETERMINED TO BE UNSUITABLE BY THE GEOTECHNICAL ENGINEER DURING CONSTRUCTION, PROVIDE GEOTEXTILE FABRIC FOR SUBGRADE STABILIZATION AS DIRECTED BY THE BOEING CONSTRUCTION MANAGER PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. 4. MINIMUM COVER OVER PIPE WITH PERMANENT CONCRETE PAVEMENT SECTION AS SHOWN IS REQUIRED TO PREVENT DAMAGE DUE TO LOADING, CONTRACTOR SHALL PROVIDE ALTERNATIVE METHOD OF PIPE AND TRENCH PROTECTION IF TEMPORARY PAVEMENT SECTION IS USED. 5. POWER AND DATA CONDUH ARRANGEMENT SHOWN REPRESENTS THE WIDEST CASE. REFER TO ELECTRICAL PLANS FOR VARIOUS ELECTRICAL AND DATA SECTIONS. (�K) PIPE BEDDING AT JOINT UTILITY TRENCH C501-6A SCALE: NITS TO C501-6C WSP 0AC 3330I9 AmmeSe S 30 CALL 48 HOURS aI fetleral Wry, 1-DOO 12Kb BEFORE YOU DIG FAX: (ZN) 1-800424-5555 FAX: czael+3l-zzs0 SYM 1 RENSION I SY APPROVED DATE SYM REVISION BRIG I APRON R - CENTRAL C180242 I WEE I SET 07/09/21 BOLLARD LAYOUT MSo A LE HARDSTAND R6 Q 3'-0. UNISTRUT P1380 FLAT PLATE FITTING P-------------------------------------------------T I I I I I I N: 185553.84 i 1 E: 1300104,97 1 N: 185554.32 I E 1300075.93 25 6 EA 0 5 OC I I I _ 4 I I \\\ I I I I/ L - - ----3 ------------I i 25'(6 EA 05'OC) 2 I � I I � I 1 N: 185539.36 1 N: 185551.34 E: 1300079.79 1 E: 1300095.29 1 R7 I 1 I I I - -----cww -�. ------ - -cwcw --- - ---0 0 0 0 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 UNISTRUT POST BASE P2072A SQ. UNISTRUT P1000 W/ (4) EPDXY ANCHOR Tj"0 HILTI HI 87 THREADED ROD W/ 4" EMBED DEPTH W/HILTI HR-HY 200, TYP 0 0 a a BY I APPROVED I DATE e UTILITY STAND NOTES: 1. UNISTRUT PART NUMBERS INDICATED ARE TAKEN FROM THE CURRENT VERSION OF THE GENERAL ENGINEERING CATALOGUE (No. 17A). CONTRACTOR MAY USE APPROVED EQUAL. 2. UNISTRUT FRAMING MEMBERS SHALL BE 12 GAGE STEEL AND SHALL CONFORM TO ASIA A1011 SS GRADE 33. 3. CONTRACTOR SHALL USE ONLY UNISTRUT FITTINGS WITH UNISTRUT FRAMING MEMBERS. UNISTRUT FITTINGS SHALL CONFORM TO EITHER ASTM A575, A576, A635 OR A36, AND SHALL MEET THE PHYSICAL REQUIREMENT OF ASTM A1011 SS GRADE 33. 4. CONTRACTOR SHALL USE ONLY UNISTRUT NUTS, BOLTS AND WASHERS FOR ASSEMBLING UNISTRUT STRUT SYSTEMS. NUTS AND BOLTS SHALL HAVE UNIFIED COARSE THREADS. UNISTRUT NUTS, BOLTS AND WASHERS ARE NOT SHOWN IN THIS DETAIL; HOWEVER, THIS DOES NOT PRECLUDE THE CONTRACTOR'S RESPONSIBNTY TO FURNISH AND INSTALL ALL CONNECTIONS AS SPECIFIED BY THE ENGINEER AND/OR AS RECOMMENDED BY THE MANUFACTURER. 5. UNISTRUT FRAMING AND FITTINGS SHALL BE HOT DIP GALVANIZED, (HG) FINISH, CONFORMING TO EITHER ASTM A123 OR A153. UNISTRUT BOLTS, NUTS AND WASHERS SHALL BE ELECTRO-GALVANIZED (EG), CONFORMING TO ASIA B633 TYPE III SOL FINISH, UNLESS NOTED OTHERWISE. 6. AFTER ASSEMBLY, APPLY TWO COATS OF BOEING APPROVED PAINT SYSTEM OVER ALL GALVANIZED SURFACES, TYP. n DETAIL - UTILITY STAND UNISTRUT - SCALE: NETS i L_BOEArw" 0 10 20 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC BOLLARD LAYOUT HARMSoSACn E: 1"=10' AND R6 Q GENERAL NOTES 1. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NM29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 2. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 3. ABOVE GRADE DRAINAGE AND UTILITY APPURTENANCES ARE SHOWN ON THIS PLAN FOR REFERENCE ONLY. SEE DRAINAGE, MECHANICAL, OR ELECTRICAL PLANS FOR DESIGN DETAILS. 4. BURIED UTILITIES ARE SHOWN FOR REFERENCE ONLY. SEE DRAINAGE, MECHANICAL, OR ELECTRICAL PUNS FOR DESIGN DETAILS. 5. HARDSTAND WORKPOINT SHALL BE ON THE CENTERLINE OF FRAME AT THE EDGE OF THE STAND AS SHOWN. SEE DETAIL 6 ON M501-1C. 6. SEE SHE PUNS FOR BACK OF CURB HORIZONTAL CONTROL. l> INSTALL BOLLARD PROTECTION AT ABOVE GRADE UTILITIES AS SHOWN PER DETAIL M501-1B CONSTRUCTION NOTES HARDSTAND WATER AND COMPRESSED AIR VALVE VAULT YARD HYDRANT AIR MANIFOLD tj WORKPOINT AT i END OF STAND. REFER TO PLAN VIEW SHEET C500-58 FOR COORDINATES. n HARDSTAND WORKPOINT \/ SCALE: 1"=10' CIVIL PERMIT E UTILITY DETAILS APRON R - CENTRAL RENTON SITE MASTER S 11 RENTON, ' R-4177073I IN COMPLIANCE WITH CITY OF RENTON STANDARDS C1802421 UK16 07/09/91 1501-1 C M03 COMP N C180242 RTN-YD-M501-iC