R-417783
I F r. rn In oI LLJ F- CURRENT LOAD - 320KVA X 125% 400KVA NEW 120/208V DEMAND LOAD - 1190.7KVA NEW HVAC LOAD - 12.5KVA TOTAL LOAD - 603.2KVA 31� 1600AF �� 600AF 1000AT 400AT 50' 3"C, 50OKcmil X MCC #11 PFD FEEDER ALT FEEDER 1 A78 (1A8)Y80E 2A8A OOKVA AA ONLY 13.8KV PRI - 480 277V SEC �Y�YI Z = 5.7% % R = 6.75(VERIFY) T\ 1600AF / 1000AT 4/� 600AF 400AT 24 382 16 79 25 963 17 510 UBS 600A MAIN 3 1/2"C 4# 50OKcmil 3T 5)� 600AF 500AT 4A6-2 225A MLO 1"C 3#6 14841 11841 14 000 T XX KVA 45 KVA 2"C, 4#1 2"C, 4#1 100' S0' 10 000 10 000 A5.5 UAS-1 UL 00A 150A (Y; MAIN MAIN 2 137 2 116 3 150 3 096 r 30000 1200A SWBD BUS - 48OY277V fi B 600AF 600AF 300AT 600AF400AT 400AT 2"C, 3#4/0 2-3 1/2"C, 3 1/2"C, X 3-50OKcmil 3-50OKcmil 126' 60' 120' 26 891 17 92 26 891 17,921 MCC #5 22 000 18 000 CBS A7 CATWALK 800A 400A MLO MLO 15513 12291 18314 1372 2"C, 3#4/0 2"C, 3#4/0 80' CZO 25A 25A 2"C, 4#1/0+1#6G MLO LMLO 17 307 13 290 17 721 13 520 20' 25 000 25 000 2 2-1/2" C, 3 25OkCMIL (1) #2G 300KVA 48OV:208Y/120V )JWITH HARMONIC FILTER — (3) 3"C-(4) 400kCMIL, (1) #2/OG < I OOOA CB A WEST TOWER NORTH UNIT SUBSTATION ,9 V26A 600-VLLM2-El VAULT DATA SHEEP 600-FDR.IA88-E1 FEEDER DATA SHEEP 600-FDR.2A5A-El FEEDER DATA SHEET 31762 1990 600AF 600AF 600AF 400AT 30 AT 600AT 3 1/2"C, 260' 2-3"C/ 3-50OKcmil 4#350Kcmil 18 000 UB6-2 600A 74AJ MLO 12 178 9 629 1 1 929 /2"C-3#2 80' 14 000 B6 100A MAIN 1"C, 3#6- 2A3.75 1 soA 1 Q' MAIN 9 746 9 088 10 000 1.1 0 12 1600AF X TIE TO V25A 21' 40' 2-1/2"C- 4#4/0 +1#4G 14 000 2B5.5 225A MLO 2 972 16.22$ 3#1/0 30 KVA 30 KVA 112.5 KVA 1 1/2"C-4#2im 30' 1 1 4 2 3C, 4 1.25"C. / �4'C, # "#40OKcmil 0 0 0 4#2 0 0' 10 000 10 000 B4.3 B4.2 A3.5-1 B6.5 UB6-1 1 ODA 1ODA 100A 100A 400A a MAIN MAIN MAIN MAIN MLO 8 973 8 433 8 971 8 433 1 793 1 778 1 770 1 757 6 114 5 856 l0000 l0000 l0000 LN Lp Lp Lp Lp Lp Lp Lp z(4) #" C, 20' 2"C, 4#1/0+1#6G w 1 (1) #6G N 3A3.25 3A3.75 2A4.25 3A4.25 3A4.5 285.5-1 385.5 TYPICAL 2A3.754 125A 125A 125A 125A 125A 125A 125A 150A MAIN MAIN MAIN MAIN MAIN MAIN MAIN MAIN 7 736 7 354 7 736 7 354 9 453 8 842 7 736 7 354 7 736 7 354 8 528 8 048 6 746 6 226 22 000 10 000 10 000 10 000 10 000 10 000 10 000 10 000 SYM REASION IN APPROVED DATE SYM I REASION A BUILD 2A3 OFFICE AREA Jp150587-04 CIERRA AACIO 07.21.05 G APRON R Cl PROJECT - DCN-01 B LINE 1 UTILITY FEEDS TO S.I. TOOL AS -BUILT 140982-51 FSI 04.14.06 H APRON R - CENTRAL - C INSTALL UTILFIES WING S.I. LINE 1 AS -BUILT 150587-01 FSI 06.05.06 D RELOCATE EBU PROJECT W2254632 CASNE CAT 05.29.14 F ARC FLASH STUDY CASNE RJJ 12.30.15 IN APPROVED DALE CASNE CEC 07.25.16 C180242 CASNE DEC 07.09.21�O`�/_i/ min 600AF 400AT TO A/P Pos � 2-3"C, — 2-3"C, 4#4/0 r , H PSR5 T60A_ X XUZ X 80' WA6-1 PNL CSBA 225A 125A 2"C, 4#4/0 MCB MAIN 1PH, 3W 4 644 4 500 10 000 REVOVAE 105 KIRKLAND, WA 98033 ;ASNE COM J09 NO 191-184 ACCEPTABILITY DRAWN DATE THIS DESIGN AND/OR R NLU ECIRCATION IS APPROVED ® FUSE CIRCUIT BREAKER, AIR, PULLOUT FRAME AND SENSOR RATING AS INDICATED 277/480V PANEL 120/208V PANEL LAAAJ TRANSFORMER, 48OV/120/208V ry-T- T UNLESS OTHERWISE NOTED CIRCUIT BREAKER, AIR LIGHTNING ARRESTER XXX XXX AVAILABLE FAULT CURRENT (CLOSED TRANSITION/NORMAL) XXX XXX EQUIPMENT AIR RATING XXX FEEDER LENGTH IN FEET REFERENCE DRAWINGS DRAWING # SUBSTATION # 04-81-82-E4 V23A 04-81-82-E4A V23B 04-81-82-E4B V24A 04-81-82-E4C V24B 04-81-82-E4D V25A 04-81-82-E4E V25B 04-81-82-E4F V26A 04-81-82-E4G V27A 04-81-82-E4H V28A 04-81-82-E5 EMERGENCY SYSTEM CONSTRUCTION NOTES DISCONNECT AND RETAIN ELECTRICAL HARDSTAND, EQUIPMENT DISCONNECTS, RECEPTACLES, PULL BOXES, AND ANY ASSOCIATED EQUIPMENT. HARDSTAND TO BE REINSTALLED. DISCONNECT AND REMOVE FEEDER CONDUCTORS BACK TO SOURCE. PROVIDE H NYLON PULL STRING IN RETAINED CONDUIT FOR FEEDER RE -INSTALLATION. DISCONNECT AND REMOVE CREW SHELTER TRANSFORMER. COORDINATE WITH BOEING CONSTRUCTION MANAGER TO RETURN OF EQUIPMENT TO CUSTOMER. ® DISCONNECT AND REMOVE CONDUIT AND CONDUCTORS FROM HARDSTAND TO CREW SHELTER. DISCONNECT AND REMOVE ABOVE GRADE CONDUIT, CONDUCTORS, AND MOUNTING HARDWARE. CIVIL PER ONE -LINE DIAGRAM VAULT V26A APRON R - CENTRAL BUILDING 04-81-82 MASTER COL 3-5/A-B RENTON, WI R-4177083 IN COMPLIANCE WITH CITY OF RENTON STANDARDS JKKLNi MLA"N 11111L WIL C180242 H 07,09.21 IEET E4F-V26AR E01 .s NO, COUP 140982-51 NO, VG NO, 04-81-82-E4F-V26AR