HomeMy WebLinkAboutR-417787a 11 VAULT VISA VAULT V8B _ _ MATCHLINE - FOR CONTINUATION SECTION 1 I SECTION 2 SECTION 3 SECTION 4—T SEE SHEET 04-020-E4F-V8 SECTION 5 SECTION 6 INCOM ETHERNET I J as 480Y/277V, 3�, 4W, 3200A Lsc aD �INCOM ETHERNET 480Y/277V 3� 4W 3200A 100kAIC BUS BRACING ,000 5,435/39,21 I f I 5,435/38,79 as.000 100kAIC BUS BRACING I I INCOM D 2A ETHERNET T ¢a (� LSIO Io I PROVISIONS SPARE Fu u (4) 4" C.O. (6) 4" C.O. UNDERGROUND UNDERGROUND TO COL S6 TO COL S6;; (4) 4"C.O. OVERHEAD TO COL S6 (2) 4"C, 4#600kCMIL & 1 #1/0 G PNL S3-1 PNL S3-3 800A 225A (2) 2"C J 1 1/2"C, 4#2 & 1#8 G 1"C, 3#4 & 1#8 G 5 480:208Y/120V,3� #6 72>1�1 1/2"C, 4#1/0 & 1#6 G PNL 53-2 225A 2B 2C L9c moo � � oo y m� �o Y 4"C, 4#600kCMIL & 1 LCP 2,578/17,52 PNL N S7-12 400A VE- 65,000 2D )�3A /�313 3C 3D I 3200AF MA 513 MC MD 3200AT T a ¢¢ oo ¢ ¢¢ ¢¢ CD ¢¢ ¢¢ ¢¢ � � LSC o o LSC o o LSG o o LSG o 0 SPARE PROVISIONS 25-TI SPARE 5- NEUTRAL — � GROUND - n n -(2) 3ki"C, 4-600kCMIL (2) 5/"C, 4-600kCMIL & (2) 3 Yz"C, & 1 Y2"C, 1 1 OG #3/0 4-600kCMIL & 20' / _ 1 #1/OG (2) 4"C, 220' 210' u (6) 4" C.O. 4-600kCMIL & (6) 4" C.O. OVERHEAD u 1 #1/OG OVERHEAD TO COL S6 TO COL S6 4,610/31.92 29 547/21 22 3s,o0o FE PNL S6-1 800A MAIN BREAKER Z PNL S7-1 PNL 57-2 �V'���J'�y� PNL S6-6 PNL 52-1 PNL 52-2 800A 800A s5,000 800A 800A 800A of 7L� MAIN MAIN 100,00o MAIN MAIN MAIN BREAKER BREAKER BREAKER BREAKER BREAKER 3#6 & 1#10G 10' r1Y2"C, 3 4& 1#6G 2Y2"-4#4/0 & 1#4G iX2"C, 3#1 & 1 #6G XFMER T7-1 0 XFMER T7-2 --n 75KVA ---- 45KVA XFMER T6-1 cr A 1 #2 = 480:208Y/120V #6 480:208/120V n 30KVA - P>3"-4#1/0 & 1#6G 480:208Y/120V 2X"C, 4#4/0 & 1#4G O U2"C, 4#2 & 1 #8G 10' IN PNL PNL PNL YNL S/-J se; -2 S7-3 S7-4 150A 100A 225A MOB 225A MCB 1OC MCB FEED THRU 3PH, 4W EQUIPMENT ONE LINE DIAGRAM SCALE: NONE PNL S6-7 225A MCB EQUIPMENT/LTG. E 6A 6B moo 0 LBC o 0 0 co m_ ao SPARE PROVISIONS 6C GO 1�7D L? m� J��Y�mw Ym I I SPARE PROVISIONS SECTION 7 4) 4" C.O. 3"-4-500Kcmll & 1#2G UNDERGROUND TO COL S6 u (6) 4" C.O. u UNDERGROUND LEGEND/SCHEDULE TO COL S6;; (4) 4-C.O. OVERHEAD XXX/XXX AVAILABLE FAULT CURRENT TO COL S6 (CLOSED TRANSITION/NORMAL) xxxx AIC RATING OF EQUIPMENT ?9,547/21,22 XXXX FEEDER LENGTH GENERAL NOTES: F­�> WIREING CONTINUED, SEE MAIN CIRCUIT BREAKER Y2"C, 3#1 & 1#6G SECTIONS, 040-020-E4F 0 10 FOOT TAP PER N.E.C. ARTICLE 240.21(C)(2). XFMER T2-1 FEEDER CONDUCTOR LENGTH TO 10 FEET -- 75KVA 3. LOAD CALCULATIONS FOR THE SUBSTATION AND MEDIUM VOLTAGE FEEDERS ARE LOCATED ON DRAWING #2 = 480:208Y/120V 04-020-E579-09, COMPRESSED AIR BUILDING PROJECT. 4#4/0 & 1#4G q2Y2"C, REFERENCE DRAWINGS DWG 04-020-E577C SUBSTATION BUILDING PLAN PNL PNL DWG 04-020-E577H SUBSTATION DETAILS S2-3 S2-4 DWG 600-SITE-YDE1 BUILDING 04-020 MEDIUM 225A MCB 225A VOLTAGE FEEDER LOCATION FEED THRU DWG 600-SITE-YDE3 BUILDING 04-020 13.8KV SYSTEM PRIMARY SWITCHING DWG 04-020-E579-09 MISCELLANEOUS DETAILS - 3"C, 3#500, #2G (VAULT & FEEDER LOAD CALCS.) PSR7 CONSTRUCTION NOTES E 1� INSTALL RETAINED EQUIPMENT HARDSTAND AND CONNECTIONS TO ALL ELECTRICAL EQUIPMENT. PROVIDE CONDUCTORS. USE EXISTING CONDUIT AS PATHWAY. R-4177087 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CCASNE ENGINEERING, INC. ELECTRICALsIM r=WMCASEC� ��° wJ O.191-184 FCIVIL P E R M I T I SYM REV610N BY APPROVED DALE SYM REVISER BY APPROAED DATE BOE//VG®OVED J'i�'�ONAL ACCEPTABILITY THIS DESIGN AND OR SPECIFICATION IS APPROVED N.LAPRISE 8�76.13 ONE LINE DIAGRAM Q180242 Q7.Q9.21 ORIG WPL: LF.C./PERMR DOCUMEM SET W1608724 CEI PJ 8.16.13 E APRON R -CENTRAL C780242 CASNE CEC 07.09.21 H N C. MALONEY 8.16.13 SHEET E05 A WPL V6 RFI-0081 W1608724 CEI PJ 03.26.14 P. JONES 8.16.13YRGINEER nTLE APRON R -CENTRALE4F2 BUILDING 04-020 ELECTRICAL MASTER VAULT S6 TT EXTERIOR RENTON, WA BY DEPT, DATE B WPL: LOAD CALCUUSIONS ADDED W1608724 CEI PJ 06.06.14 cHHCNHD C ARC FLASH STUDY CASNE CEC 07.23.15 APPROVEDD JOB NO, COMP NO. APRON R CI PROJECT - DCN-01 CASNE CEC 07.25A6 APPROVED DWG No. 04-020-E4F2-V8