HomeMy WebLinkAboutR-412347SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. s? Q0 Lf i I N N O N N Q a� c/-) 77) CD I") Wo BPU-10241B-PV WADOE GUILD Max Treatment Flow 0.72 cfs Max Peak Flow 20 cfs 2.00" MULCH. 18.00" StormMixTN MEDIA 6.00" DRAIN ROCK. 3X 04.00" SLOTTED PVC UNDERDRAIN PIPE. QCENTInKI Q Q 2X 6"x24" INLET WINDOW, EL: 25,21'. DRAIN DOWN DEVICE Z RIM: 29.63' 6.08' IE:23.55' -gypp INLET, 026" OPENING L FOR 018" HDPE. INTERIORIEXTERIOR JOINT SEALANT REQUIRED, (CONSEAL CS-231 OR EQUIVALENT), BY OTHERS. D INLET, 026" OPENING FOR 018" HDPE, IE: 23.55'- LI II II I I. II 17-6' 1 V-6" 10'-0" FOOTING WALL OD WALL ID I I I II II A fl lII II. f L 2X 036.00" BOLTED 8 GASKETED ACCESS COVERS, FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. 2" SLOT RIM:29,63' TYPICAL NLJ I tJ: 1 DESIGN LOADINGS: A. AASHTO HS-20-44 Wf IMPACT S. DESIGN FILL: I' MAXIMUM. 26'-6" SLAB OD C. ASSUMED WATER TABLE = V BELOW GRADE D, DRY LATERAL EARTH PRESSURE IEFP)-40 PCF 26-6" WALL OD E. LATERAL LIVE LOAD SURCHARGE = SO PSF (APPLIED TO 8' BELOW GRADE). 9' TYPICAL F NO URCHARGE M ADJACENT 24'-0" WALL ID WALL THICKNESS BUILDINGS, OR FOUNDATIONS. • 8" 10'-1" 2. CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE 5.000 PSI MINIMUM 3. STEEL REINFORCEMENT: REBAR. ASTM A-615 OR 2X DRAIN DOWN DEVICE A-706, GRADE 60. 4. MESH REINFORCEMENT ASTM A-1064, S1.2. GRAD B0. 5. CEMENT: ASTM CA 50 SPECIFICATION r 6. REFERENCE STANDARD: 6X 04.00' SLOTTED PVC B. ASTM C 913 UNDERDRAIN PIPE. 7- THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. PLEASE VERIFY i Y v A A I B I I Q) B THAT THESE PARAMETERS MEET PROJECT I I REQUIREMENTS (LE. UVE LOAD. FILL RANGE. 1 WATER TABLE). IF DESIGN PARAMETERS ARE jj I INCORRECT, REVIEWING ENGINEEPJAUTHORITY , I- SHALL NOTIFY OLDCASTLE INFRASTRUCTURE 1.1 I UPON REVIEW OF THIS SUBMITTAL O a 0 .11 .I A 8 OVERSIZED HOLES TO ACCOMMODATE SPECIFIC PIPE TYPE MUST BE CONCENTRIC TO PIPE ID. AFTER PIPES ARE INSTALLED, ALL ANNULAR SPACES SHALL BE FILLED WITH A MINIMUM OF 3000 PSI CONCRETE FOR FULL THICKNESS OF PRECAST WALLS. PIPES ARE TO BE FLUSH WITH THE INSIDE SURFACE OF THE CONCRETE COBBLES FOR ENERGY DISSIPATION D 2X 6"x24" INLET WINDOW, EL:25.21'. STRUCTURE OUTLET, 026' OPENING BYPASS WEIR, EL: 25.8T. 9 CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES FOR 018" HDPE, IE: 23.04'. LOCATIONS AND ELEVATIONS OF OPENINGS 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (LE COMPACTED AND LEVEL PER PROJECT PLAN VIEW SPECIFICATIONS). t I. ADAPTOR5IANGLESRND EXTERNAL PIPING BY OTHERS. IZ SYSTEM SHIPPED EMPTY. INTERNAL PIPE, FILTER MEDIA & DRAIN ROCK PROVIDED IN BULK & INSTALLED BY OTHERS. t3. MAXIMUM PICK WEIGHT IF 45,1100 LBS (MEDIA SHIPPED SEPARATELY AND INSTALLED BY CONTRACTOR). 14. OLDCASTLE REPRESENTATIVE TO BE ON SITE TO OVERSEE THE INSTALLATION OF ALL INTERNAL 2X 024.00" BOLTED &GASKETED ACCESS COVERS, COMPONENTS BY INSTALLING CONTRACTOR BYPASS WEIR, EL: 25.87'. FIELD POURED CONCRETE COLLAR REQUIRED, BAFFLE WALL BY OTHERS. 'THIS MUST BE FILLED OUT BEFORE 2X 6"x24" INLET MANUFACTURING BEGINS' WINDOW, EL: 25.21'. -4' ADJUST TO GRADE DRAIN DOWN DEVICE APPROVED W/ NO EXCEPTIONS TAKEN: ❑ RIM: 29.63' APPROVED AS NOTED: . "-�-r'='�---- • '- - 1 TOP REVISE AND RESUBMIT r I : BAFFLE WALL EL: 25.87' [78.. 9.08 2.81' yy ti.+ w a L SIGNATURE DATE [33.72"]S (71 IE: 23.06' ` +: 10" BASE Oldt�astle Infrastructure' - • • -' - . :. ; - • -- EL: 22.21' watxtwrwr OUTLET, 026" OPENING INLET, 026" OPENING ///6X 04.00" SLOTTED PVC w ern e.. • " M."N nR,,wM. FOR 018" HDPE. INTERIOR/EXTERIOR JOINT FOR 018" HDPE, FARSIDE. UNDERDRAIN PIPE. »IBODcuMEmis,NEPRd•E OFOLocr3-FINFRASTROETURE-C. IT IS CONFIDENTI.LL, BUSMITTEO FOR REFERENCE PURPOBEB ONLY ;ND 06.00" PVC OUTLET ORIFICE SEALANT REQUIRED, TREATED OUTLET ORIFICE COBBLES FOR ENERGY DISSIPATION SITYL FIOT BE USED IN - WAr l Or RIOUS 10 THE INTERESTS OF OR ,LOUT THE WFITTEN PERMISSIOx F OLOCASTLE INFRASTMICTURE.IhC CAP INTO OUTLET CHAMBER. (CONSEAL CS-231 OR CAP INTO OUTLET CHAMBER. OUTLET, 026" OPENING r.QfYSONT6RU0 <sTLe IHFR B RUc URF, Ixc All RIOHT9RFBewFn EQUIVALENT), BY OTHERS. FOR 018" HDPE, NEARSIDE. BioPod- BiofiRer Underground SECTION D-D 10'x24' Panel Vault with Internal Bypass SECTION A -A VJSTOWR HD Fowler JU1114 E Topgolf Renton -Renton. WA A N c SM120 010-AU PPS MJT MJT stil9ss PDD- 'TION BY DATE w» • 10545 �YDAE I of 1 BIOINFILTRATION UNIT (WEST BASIN) FIGURE 5.1.4-k SCHEMATIC REPRESENTATION OF A FLOW RESTRICTOR (TEE) 11 MIN UNDER PAVEMENT REMOVABLE ELEVATION WATERTIGHT PER PLANS COUPLING OR FLANGE-716" MA?L 2" MIN. 6" MIN, OW RE ICTOR s"IIN_ E D L- a' MAX.- PLATE WELDED PIPE SUPPORTS 1 5 x a SEE NOTE 6 MI24 TO ELBOW WITH T ORIFICE AS SPECIFIED D 1 y ELBOW RESTRICTOR � OUTLET PIPE DETAIL SEE NOTF5 1 & 5 NTS INVERT AND ELEVATION PER PLANS RESTRICTOR PLATE WITH ORIFICE DIAMETERA$ SPEC IFIEO (NOT NEEDED IF FOR SPILL CONTROL ONLY ACCESS ADJACENT TO TEE 2" MIN. CLEARANCE TO ANY PORTION OF FROP-T INCLUDING ELBOWS A ISOMETRIC NTS ELBOW RESTRICTOR SEE DETAIL NTS FRAMEa SOLID COVER MARKED "❑RAIIN" WITH LOCKING BOLTS SEE NOTE 3 & KCROCS DWGS7-022.7�VERT11rALBA TOP OF RISER ELEVATION CB#5: 26,17 TOP OF RISER ELEVATION CB#20: 28.83 R WATER SURFACE 2' MIN. SECTION A -A NTS SECONOARYINLET RAkNDHOLDS, STEPS OR LADDER SEE KCROCS DWG, 7-006 INLET PIPE ROD FOR CLEANOUTORAIN (ROD BENT A5 REQUIRED FOR VERTICAL ALIGNMENT WITH COVER)SEE KCRDCS DING. 7.026 ADD ITIONAL LADDER RUN (IN SETS) TO ALLDW ACCESS TO TANKS OR VAULTS WHEN CATCH 15 FILLED WITH WATER, 1 A NOTES: AN.GLF AS 1. USE it MIMIMUMI OF A 54" DIAMETER TYPE 2 CATCH BASIN. NECESSARY 2. OUTLET CAPAG]TY, 100-YEAk DEVELOPED PEAT{ FLOW. PLPLAN ��� SSE EEE NNOTEOTE 7 3, METAL PARTS: CORROSION RESISTANT, NTS STAINLESS STEEL OR ALUMINIZED STEEL. 4, FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP- E- CLIMB -DOWN SPACE 15 CIrEAR OF RISER AND CLEANOUT GATE. C FRAME IS CLEAR OF CURB, S. IF METAL OUTLET PIPE CONNECTS TO CEMENT CCNGRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE 1.0- LESS 1/4" 6. PROVI❑E AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL (MAXIMUM 3'. 0- VERTICAL SPACING) 7, LOCATE EL80W RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. S. LOCATE ADINTIONAL LADDER. RUNGS IN STRUCTURES USED AS ACCESS TO TANKS ANO VAULT TO ALLOW ACCESS WHEN CATCH BASIN I$ FILLED WITH WATER. 9. TEE SHALL BE CONSTRUCTED OFALUMMUM CMP OR ALUMINIZED STEEL CMP MEETING WSDOTIAPWA STANDARDS. FLOWRESTRICTOR (TEE) NTS UNIT ID: East BioPod Underground - Panel Vault Treatment Flow Rate = 1.38 cfs 6" 6" TYP INLET, 026" OPENING FOR 018" CPEP, IE: 24.96' 2X V-9" OD WALL ID 3X INTERIOR BAFFLE WALL, EL: 28.96' 10'-9" MEDIA SURFACE AREA 2" MULCH. 18" StormMix- MEDIA JW(4X 12" DRAIN ROCK. 06" SLOTTED PVC UNDERDRAIN PIPE. SECTION B-B 6X 024" BOLTED & GASKETED ACCESS COVERS. FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. 3X INTERIOR BAFFLE WALL, 3X INTERIOR BAFFLE WALL, EL: 28.96' EL: 28.96' 5X DRAIN DOWN 2X INTERIOR WALL, DEVICE, SK-0962 EL: 29.29' RIM: VARIES BYPASS WEIR, VARIES EL: 27.63' 1 2X 030" DOGHOUSE J OPENING, IE: 24.46' 40'-6" SLAB OD 39'-6" WALL OD 38'-0" WALL ID - #1 12'-0" MEDIA #2 12'-0" MEDIA #4 12'-0" MEDIA SURFACE AREA SURFACE AREA SURFACE AREA 8X4"x24"INLET 6" 2'-6" 5X DRAIN DOWN WINDOW, DEVICE, SK-0962 B D IE: 27.13' BBB I�B I�B BBB OMB B ® I -D 8X COBBLES FOR 4X 06" SLOTTED 2X INTERIOR WALL, ENERGY PVC UNDERDRAIN EL:29.29' DISSIPATION. PIPE. PLAN VIEW (TOP SLAB & BASE SLAB JOINT PROJECTION NOT SHOWN FOR CLARITY) 9" TYPICAL WALL THICKNESS BYPASS WEIR, EL: 27.63' OUTLET, 026" OPENING FOR 018" CPEP, IE: 24.46' 08" ORIFICE CAP 012"DOGHOUSE OPENING FOR 010" PVC 6X 036" BOLTED & GASKETED ACCESS COVERS, FIELD POURED CONCRETE COLLAR REQUIRED, -14'-0" TOP SLAB #1 13'-0" TOP SLAB #2 13'-6" TOP SLAB #3 BY OTHERS. 2X 030" DOGHOUSE BYP S OPENING, IE: 24.46' 2X INTERIOR WALL, TOP OF STRUCTURE : 30.79' A EL: 29.29' RIM: VARIES a:.... <._. :,l ;; .., s .. • t)^ `" .. ..'' r ,.,..-... . T. ..., . , ri 1,-4" SLAB 31.12' IN C= I O H O Oli;il C= I C= I C= HIA O I O N^ IE: 24.96' Y O INLET, 026" OPENING10" R 4X 06" UNDERDRAIN. SLAB #1 " OPENING FOR 018" CPEP FOR �20'-3" BASE Y 20-3" BASE SLAB FOR 4/ 8X COBBLES FOR ENERGY DISSIPATION. 5X DRAIN DOWN 10"x84" OPENING FOR 4X 06" UNDERDRAIN, DEVICE, SK-0962 J BX 4"x24" INLET WINDOW, IE: 27.13' IE: 24.46', (TYPICAL 2 PLACES). INTERIOR/EXTERIOR JOINT SEALANT REQUIRED, (CONSEAL CS-231 OR EQUIVALENT), BY OTHERS. SECTION D-D SECTION A -A (OUTLET PIPE NOT SHOWN FOR CLARITY) 3.17' P8.00"] 6 1'-2" SLAB IE; 24.46' OUTLET, 026" OPENING FOR 018" CPEP 012" DOGHOUSE OPENING FOR 010" PVC BIOINFILTRATION UNIT (EAST BASIN) NTS BlorelenUW Bi"fl4"IUn NU I tJ: 1. DESIGN LOADINGS: A. AASHTO HS-2044 WI IMPACT. B. DESIGN FILL: 1' MAXIMUM. C. ASSUMED WATER TABLE = 5' BELOW GRADE. D. DRY LATERAL EARTH PRESSURE (EFP) = 40 PCF. E. LATERAL LIVE LOAD SURCHARGE = 80 PSF (APPLIED TO 8' BELOW GRADE). F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE 5,000 PSI MINIMUM. 3, STEEL REINFORCEMENT. REBAR, ASTM A-615 OR A-706, GRADE 60. 4. MESH REINFORCEMENT. ASTM A-1064, S1.2, GRADE 80. 5. CEMENT: ASTM C-150 SPECIFICATION. 6. REFERENCE STANDARD: A. ASTM C 890 B_ ASTM C 913 7. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. PLEASE VERIFY THAT THESE PARAMETERS MEET PROJECT REQUIREMENTS (I.E. LIVE LOAD, FILL RANGE, WATER TABLE). IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEERIAUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW OF THIS SUBMITTAL. 8. OVERSIZED HOLES TO ACCOMMODATE SPECIFIC PIPE TYPE MUST BE CONCENTRIC TO PIPE ID. AFTER PIPES ARE INSTALLED, ALL ANNULAR SPACES SHALL BE FILLED WITH A MINIMUM OF 3000 PSI CONCRETE FOR FULL THICKNESS OF PRECAST WALLS. PIPES ARE TO BE PLUS WITH THE INSIDE SURFACE OF THE CONCRETE STRUCTURE. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS AND ELEVATIONS OF OPENINGS. 10, CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. MEDIA, DRAIN ROCK, MULCH, AND INTERNAL COMPONENTS SHIPPED SEPARATELY. INSTALLER RESPONSIBLE FOR PLACEMENT OF THESE MATERIALS IN THESTRUCTURE. 12, OLDCASTLE REPRESENTATIVE TO BE ON SITE TO OVERSEE INSTALLATION, 13, CONTRACTOR TO ENSURE UNIT IS PROTECTED FROM CONSTRUCTION DEBRISIRUNOFF AFTER INSTALLATION. 14, CONTRACTOR RESPONSIBLE FOR SUPPLYING CRANE TO Q OFF-LOAD AND SET PANELS; SUPPLY PERSONNEL AND TOOLS NEEDED FOR INSTALLATION; INSTALL GASKET AT TOP, BOTTOM AND BETWEEN ALL WALLS: GROUT ALL SEAMS & WALL CONNECTIONS PRIOR TO BACKFILLING (GROUT TO BE NON -SHRINK, 5000 PSI MINIMUM BEFORE BACKFILLING). 15. SECTION HEIGHTS, SLABAVALL THICKNESSES AND KEYWAYS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY AND PRODUCTION PLANT CAPABILITY. 16, ADAPTORS/ANGLES AND EXTERNAL PIPING BY OTHERS. 17. MAXIMUM PICK WEIGHT: 61,700 LES. N O N O O O (4) r �A I X a 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com �L ZA R OF WASgj��� itally sign by nelle T flin Date: 9 UUUU 2022.09.3 418726:M 29-MO' �'SSIONAL 0 ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR Z VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q R-412347 BY O V IN COMPLIANCE WITH CITY OF RENTON STANDARDS W SURVEYED: SCALE: DATE: Z.NALL VERTICAL: NAVD 1988 ARCO/M U RRAY 09.26.2022 J HORIZONTAL: NAD 1983/1991 CITY O F DESIGNED: :� TOPGOLF RENTON PAGE:FIELDBOOK: 0 2 RECORD DRAWINGS NAVIX 09.29.22 JET J.GREEN � RENTON 780 LOGAN AVENUE NORTH PAGE: O DRAWN: I _ ® 2 RECORD DRAWINGS NAVIX 06.10.22 JET J.GREEN DRAWING NO: rvn ONE INCH DATUM Q 4 1 RECORD DRAWINGS NAVIX 05.17.22 JET CHECKED: AT FULL SCALE RENTON WA 98057 C'3R12 a J.TAFLIN SCALE ONE INCH Planning/Building/Public Works Dept. NO. REVISION BY DATE APPR APPROVED: DRAINAGE DETAILS SHEET: OF O J.TAFLIN 47 82