HomeMy WebLinkAboutW-412309SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. M N Tm N ^^I 1� I— m%4 n 00 N-) Lri I N N CD N N Q (D cf) SHACT4LE RODS „ ... TYPE A 1LOCKING mom. TYPE B } + PUBLIC WORKS CONCRETE BLOCKING OR VERTICAL FITTINGS DEPARTMENT II +'EUPORARY 2" CALVANIZED PIPE AND 2" GATE VALVE .LI'I SHED GRADE ELEVATION INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 Fll MINL COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) NEW WATER MAIN POLYPIG ~I � VERTICAL CROSS FOR POLYPICCING STATION. - SIZE 4F VERTICAL CROSS SHALL 13E THE SAME AS SIZE DF MAIN LINE VERTICAL CROSS (MJ X FL) Did€ BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW --OFF ASSEMBLY (REMGVE BLOW -OFF ASSEMBLY AND INSTAL). 2' PLUG AFTER REMD'Mt OF CLEANING "POLY -PIG") ONE BLIND FLANG€ ON BOTTOM OF CROSS ON€ PLUG (MJ) DIN END OF CRO55 CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL, BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION DF NEW WATER MAIN REGISTER SHALL BE TOUCH READ PIT Up a" RasT INDICATOF? VALVE PRECAST CONCRETE VAULT WITH 3 - Y7 31 ONE EACH SIDE (TR-PL) AND BE INTELLIGENT COMMUNICATION HINGED STEEL PLATE COVERS. DIMENSIONS ENCODER TYPE ICE METERGIENT MUST REAP W tMJXKW) PAINTM FLUE 4" ADAPTER, FL_x SCREWED 5',Syx 11'-2"x 7�-2" E41JeAi TO U3TLITY } 2-3j4" SHACKLE OCAS PER CITY VAULT OR EQUAL 4"x4 xfi" BULL HEAD TEE. FL- U. FT, OF RENTON SPECIFICATFONS TOUCH READ PIT LIT) SENSOR A' G4' RFNo ("u) "- 4" 9O' LIEND CMW) MOUNTED ON STCEL I'LAM ptpg FL x 1NSTALL IN TEST COVER THROUGH IN CO DER_ 4 DRILLED FIOLE IH COVER. FL 2'-D" L T3 LF 4" D.1 PORT A NIPPLE . TEE (M.I.:L) � BRASS NIPPLE WITH 12" THE BY-PASS AS$EMRLY SHALL BE w GATE VALVk (1T_xMU} 7�,0" A 2" RESILIENT i o � INCLUDED A�5 PART OF THE DETECTOR SEATED BRASS GATE DOUBLE CHECK VALVE A55EMBLY 18" FOR 10" ASSEMBLY e z J LADDER WITH VALVE AND 2" PLUG. 5/8"x3%4" EENSUS SRII (TR/PQ METER 17 1/2" FOR 9" ASSElA9LY a' FLxMJ ADAPTOR SUPPORT BARS :2 -4" 4" FLaMJ ADAPTOR WITH ICE REGISTER, 14 1/2' FOR 6" ASSEMBLY * PER Obi ti I - 2 4" a b" D.I. _ _ CIS PRIVATE TQ BALIXNG PIPING PIPIN4 e EPDXY NON -SHRINK 1T (Md I, FL) 11 GROW? • " GATE VALVE EFL W MS1 2'-1rr 4" TEE (M16-1_3 5•_ S•• WELDED STEEL COLLAR CITY PRIVATE TOUCH READ PIT UD SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DSA PIPING PIflNG vE4 ID I.ED HOLE IN COVER. LOCATE HOLE FN3" FROM EDGE OF PIT LID AND RIPS {� TEE RE0IJIRED VnTH 'SHACKLING TO TEE !2" ALL AROUND 2 - 6 _ (FL} CONCRETE r 1,• . _ _ - PRECAST CONCRETE VAUL7 OATH 2 3".3" HINCM STEEL BLQCKkNG - PLATE COVER, OUTSIDE DIMENSIONS a'-13'a7'•-D'• (EQUAL TO PEPE INC., 0R UTILIZY VAULT WITH ALL DETECTOR DOU@LE CHECK YALVE 57-71L-8, 2 SxV DIAMOND PLATE DOO)RSI SENSUS MODEL 52OR RADIO READ PIT SET SENSOR B" OR 6" FLx P.E_ ASSEMBLIES SHALL INCLUDE RESILIENT PLAN 8',�S" Oli 3- GATE VALVE {FL:FL] MOUNTED ON STEEL RLAT1= TVlU PIECE fin',,; 1-�.•I:.,',..t_,.� COVER THROUGH 2' OLA. EQUAL TO OLYMPIG FOUNDRY CO- i:IrE VATii COLLAR 1$` FROM P_E. SEATED SHUTOFF VALVES AND TE5T COCKS AND APPROVED NON -RISING STEM WITH HAND WHEE EODAL 1-0 MIJELLER CO_A-231M-6. ➢FULLED HOLE IN COVER STANDARD 8 TOP SECTION, WIT}l i0"- LONG CROSS -CONNECTION CONTROL ASSEMBLIES PER DEPARTMENT OF REGULAR BASE SECTION LENGTH TO FI -6` B'- 3'-S" LONG HEALTH LATEST APPROVED LIST B" DR A" (LZxPE) CEMENT LJNED 5"- 4'-D, LONG DUCTILE IRON PIPE CLASS 52 3'-6" LONG N+T11 COLLAR 2D" FROM P.E. DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESIDENT SEATED EDUAL TO THOSE SUPPLIED BY PACIFIC VALVE NUT EXTENSION 1F RE;U!Pr_- 4HS17F7FF VAI VFS �3•' WATER WORKS UQ. INC. (ow013"/PRGE 6o96) " 10', 8'. OR 6' J:LANGED GDUPLJNG ADAPTER EQUAL TO ROMAC. 12- AROUND- 1, Ii LI 6'.4" OR 3" D"D 1�ao M tFl) J E4ilAL T9 S£N51JS SRII COMPOUND WITH TOUCHREAR PITUD I,C.E. REOS7f.R k WITH 4 WHEEL HIGH RESOLUTION AD,NSTAEpF STEEL FEET) RE615TER. FOR 3' METER, REDUCE AT PE SUPPCIi1' METER MTH 4'X3' FL.FL .CONCENTRIC STANQHION BOLTED REDUCER. Tp FLOOR GENERAL NOTES: ALL iAETERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHM OR ENCLUDEO IN THE STANDARC DETAIL DRAWINGS, IF YOUR PARTICULAR COMBINAIICN IS NOT SHOWN. AN APPROVED DRAWING WILL BE REQUIRED BY THE UTILITY ENGINEERING DEPT FOR ITS INSTALLATION, THE PRINOPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, [WHtCii CLEARANCE SHALL SE A MINIMUM OF 12" FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE A$ TYPICALLY SHOYIIN ON THE VARtOU5 STANDARD DETAILS}. NOTE: DEADMAN BLDCK SHALL BE DESIGNED AND INSTALLED S❑ IT REARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED] THRUST- 6 • 4 OR 3 GATE VALVC (FLxMJ) EOWAL TO MUELLER CO A-23B0-20_ rO BUII'DING CITY PRIuvTE PIPHfG P14xp{C V6' Oft 4" PExPE CEMENT 1JNE0 OUDTILE IRON PkPE CLASS 52. LENGTH TO FIT. 5" QR 4' FLEXIBLE FLANOEU L'UUHLJ'RG AU.Ah'IL41, "UMAU DR APPIWV♦=D ECIUAL TOUCH READ PIT LID SENSOR MOUNTED NOTE: ON STEEL PLATE COVER THROUGH 2" DIAL. DRILLED HOLE IN COVER, I_ LOCATE VAULT IN PLANTING AREA. NOT IN PAVING. 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT UNEi7, 18" FOR 10' ASSEMBLY 17 1/2 FOR B' ASSEMBLY IS 3 TEMPORARY SUPPORT SHALL BE PROVIDED UNDER 1/2' 1/2' FOR 6" ASSEMBLY 2ALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPEN NG. AFTER COMPLETE 5r6'x3/4' INVENSYS INSTALLATTON REMOVE THE TEMPORARY SUPPORT TR-PL METER WTH T•-2" AND INSTALL AD.iUSTABLE PIPE SUPPORT. ICE REGISTER IhSTAtL GALVANIZED LADDER FOR ACCESS. 6" ViN, DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH AFTER FIELD INSTALLATION, MAIN DDCVA AND CATCH BASIN 04. MANHOLE BY-PASS DCVA VUST BE TESTED -SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TO CITY OF R£NTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE COMPACTED FOUNDATION " INSTALL BRASS A* FLARE TEST COCKS Willi Y." GRAVEL FLARE CAPS. 4'x 2 1/2' FIRE DEPARTMEt•1T DOUBLE CONNECTION FOR STAND PIPE WITH BREAKABLE CAST IRON HOSE CAPS. ONE EACH SIDE ECIUAL TO GRINNEL FIG. 1662 WITH HOSE CAPS FIG, 1333_ - 6' SWING TYPE GRAVITY OPERATED CHECK VALVE. FL, EQUAL TO MUELLER CO. A-2600-6 WITH BALL DRIP VALVE AT BOTTOM INSTALL EPDXY NON -SHRINK CROUT (T)P.). 5" PIPE. FL x FL. 3.0" LONG [6'& 8' ASSEMBLY. 6' SFIOF RADIUS 90' BEND FL 1fl" A-,gFURIY 9{1' REDUCING BEND FL. ITO BUIL➢ING DEADMAN a BLOCK REQUIRED. 8".6' FL x MJ ADAPTOR 10' ASSEMBLY 10"00"xa'TEE FL. 8' A55EMBLY B'xB"x5" TEE, FL 6' A51AMBLY 0'4"4" TEE, FL. 10% B'• OR 6' GATE VALVE, FLx MJ, WITH INDICATOR POST. INDICATOR POST VALVE SAME SIZE A$ PQURLE CHECK VALVE (MUELLER CO. OP EQUAL). PAINTED RtD. 10`, 8", OR 6" 01tCTILE IRON CLASS 52 NIPPLE PIPE, CEMENT uNED, LENGTH TO FIT PI x 5" 90' BEND FL.� GALVANIZED tf�STER .ADDFP 1 AMWSTADLC STEEL PIPE SUPI'GRT, STANCHIONS BOLTED TO FLOOR. STD. PLAN - 330.3 4 STD. PLAN 300.8 „ sm. Pi" - 520.4 6" S" & 1 D" ❑ O U B L E DETECTOR CHECK STD . PLAN - 360.2 t PUBLIC WORKS POLY PIG STATION FOR CLEANING OF * + PUBLIC WORKS 3", 4 & 6' COMPOUND DOMESTIC sI PUBLIC WORKS ASSEMBLY WITH STANDPIPE OUTSIDE ,VARCH 2O10 I]EPARTMENT WATER MAINS -MARCEL 2010 f a. DEPAR'FMENT WATER METER ASSEMBLY MARCH 2010 _ DEPARTMENT MARCH 2010 INSTALLATION 3„MAx. Z o0 � C] 5"MIN. TO Cl TY METER STACKED METER SECTION\_6" MIN. FREE BOXES DRAININC CRAVI=- NOTES-. 1, ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA'sj MUST BE LISTED ON LATEST LIST OF 'BACKFLOW PREVENT10r.. ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE ❑F WASHINGTON [DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENT4N PLUMBING PERMI'T FOR THE INSPECTION OF THE IN5TALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAhNTAIN THE DCVA ANO ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST RE TESTED BY A STATE CERTIFIER E4CKFLOW ASSEMELY TESTER AFTLR ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S E}CPENSE_ A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING ❑EPT_, ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-434-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER VETER_ T" Q Q 1 N LA Q Q Q C) 1 r lirA "'I"lX 1 a -ITS I CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com ��,I WA 6ABET itally sign y nelle T flin Date: 2022.09.3 418726:3,9:41- zoo' ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR Z VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q W-412309 BY o V IN COMPLIANCE WITH CITY OF RENTON STANDARDS W �l Y PUBLIC WORKS 34" TO 2" DOUBLE CHECK VALVE SM. PLAN - 340.8 Z DEPARTMENT ASSEMBLY FOR IRRIGATION OR O RESIDENTIAL FIRE SPRINKLER MARC14 2010 Z NW w SURVEYED: SCALE: DATE: VERTICAL: NAV1988 Z.NALL HORIZONTAL: NAD D1983/1991 ARCO/M U RRAY 09.26.2022 J DESIGNED: % CITY OF FIELDBOOK: 2 RECORD DRAWINGS NAVIX 09.29.22 JET J.GREEN TOPGOLF RENTON ® 2 RECORD DRAWINGS NAVIX 06.10.22 JET DRAWN: PAGE: '� RENTON 780 LOGAN AVENUE NORTH PAGE• O ONE INCH DATUM (�DRAWING NO: Q 1 RECORD DRAWINGS NAVIX 05.17.22 JET CHECKED: AT FULL SCALE RENTON WA 98057 C-4.8 a G� J.TAFLIN IF NOT ONE INCH Planning/Building/Public Works Dept. NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY WATER DETAILS SHEET: OF: O J.TAFLIN 57 82