Loading...
HomeMy WebLinkAboutW-412302SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SEE SHEET C-4.2 FOR CONTINUATION N 7 Tom N C I N H 1 1 1 �: z 0 F- z LU w LL J 0 0 IL 0 F- I N U) U) 3IgI rngr ` I M .. c >P — �r - =c STA: 0+83.5 20 LF 12" DI P— 10LF6"DI M E �� I Q N LH I CONTRACTOR TO VERIFY LOCATION OF EXISTING SD LINE. cNv IF A CONFLICT WITH PROPOSED WATER LINE IS IDENTIFIED N NOTIFY THE CITY AND PROVIDE PLAN REVISIONS. cc CONTRACTOR TO VERIFY IF EXISTING BOEING HIGH PRESSURE) `V WATER MAIN PRESENTS A CONFLICT WITH PROPOSED WATER Q) MAIN. IF A CONFLICT WITH PROPOSED WATER LINE IS v' IDENTIFIED AND REQUIRES CHANGE OF PROPOSED WATER LINE THEN NOTIFY THE CITY AND PROVIDE PLAN REVISIONS. LEGEND 0 �I PROPERTY LINE -WWWWW- EX. 12" WATER MAIN 0' WATER LINE I ,I FIRE DEPARTMENT CONNECTION 360.2 C-4.8 BEND/TEE WITH THRUST BLOCKING 330.2 o C-4.7 ~ ►� GATE VALVE 330.1 i C-4.7 DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY 360.2 :3 -A REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2 Q C-4.7 ® DOUBLE CHECK VALVE ASSEMBLY 340.8 i� FIRE HYDRANTry 14:7 3" DOMESTIC WATER METER r32.4 Q, 8 c Cn 6m 2" IRRIGATION 320.2 WATER METER m ►91 29 _ a = LF 12" DI LF 12" DI- I — 15' WATER UTILIT EASEMENT LL. I�I O 13 LF 6" DI 8 6+00 65 LF 12" Di l �I - I C 14 4 LF 12" DI EXISTING STORM — DRAIN LINE 14 TO BE 5+00 ABANDONED IN PLACE 88 LF 12" DI — � I 20 LF 2" DI 20 LF 3" DI 27+36 7 - 5 LF 12" DI 26+00 6 LF 12" DI' 3 5 c� 23+09 22 � 2 + �TA.J4+12.311 �26 LF 6" DI o 29 LF 12" DI o 0 \/h 4+00 0 2 LF 6" DI 19 LF 12" DI 12 LF 6" DI I■I IPA wk. —m mu •• CN �� • �,� 7—A OGAN AVE N -- (IS lim Fil i i i i N M M a�.. IT m WATER SCHEDULE KEY NOTE KEY NOTE KEY NOTE KEY NOTE KEY NOTE OSTD CONNECT TO EXISTING 12" WATER MAIN (CUT IN BY CITY FORCES) PER COR PLAN 300.4, SHEET C-4.8 WITH: 1 - 12" x 12" TEE (FL) 3 - 12" GATE VALVES (FL x MJ) 3 - 12" SLEEVES (MJ x MJ) WITH THRUST BLOCKING SEE PLANS FOR STATION CONTRACTOR TO VERIFY EXISTING WATER MAIN LOCATION AN D DEPTH PRIOR TO CONSTRUCTION ANY PORTION OF PROPOSED WATER MAIN EXTENSION CUT IN BY CITY FORCES AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 3 O 1 - 12" 90° BEND (MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 8 O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 15 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 6+15.59, 15.03' LT 20 1 - 3" DOMESTIC METER PER COR STD PLAN 320.4, SHEET C-4.8. INSTALL 4" x 3" REDUCER INSIDE 5' x 7' x 7' METER VAULT. STA: 25+77.07 25 1 - 2" PRESSURE REDUCING VALVE 1 - 2" BACKFLOW ASSEMBLY DCVA IN METER BOX PER COR STD PLAN 340.8, SHEET C-4.8. STA: 27+04.75 (PRV) STA: 27+10.20 (DCVA) O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 12 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 3+69.47 14.55' LT 21 1 - 3" PRESSURE REDUCING VALVE 1 - 3" BACKFLOW ASSEMBLY MOUNTED ON CONCRETE PAD IN HOT BOX PER COR STD PLAN 350.2, SHEET C-4.7. STA: 25+62.70 (PRV) STA: 25+68.45 (RPBA) 14 1 - 12" 45° VERTICAL BEND (MJ) WITH MEGALUG WITH THRUST BLOCKING PER COR STD PLAN 330.3, SHEET C-4.8. SEE PLAN FOR STATION 26 IRRIGATION POINT OF CONNECTION. SEE PLAN FOR STATION. SEE LANDSCAPE PLANS FOR CONTINUATION. O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 1 - 12" GATE VALVE (FL x MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 16 O 1 - POST INDICATOR VALVE DOWNSTREAM OF DDCVA STA: 22+66.48 22 1 - 12 US BEND MJ WITH THRUST BLOCKING SEE PLAN FOR STATION 27 BUILDING POINT OF CONNECTION. SEE PLAN FOR STATION. SEE PLUMBING PLANS FOR CONTINUATION. 17 1 - 6" DOUBLE DETECTOR CHECK VALVE ASSEMBLY PER COR STD PLAN 360.2, SHEET C-4.8. STA: 22+74.42 23 1 - 4" 45° BEND MJ WITH THRUST BLOCKING STA: 24+17.62 " 1 - 3DOMESTIC SERVICE CONNECTION SEE PLAN FOR STATION O6 2 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 10 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 0+61.76, 11.91' LT 24 1 - 2" IRRIGATION METER PER COR STD PLAN 320.2, SHEET C-4.6. METER TO BE INSTALLED WITH A 17" x 30" METER BOX. STA: 27+14.87 18 1 - FIRE DEPARTMENT CONNECTION STA: 22+76.49, 5.73' RT 29 O CONCRETE DEADMAN BLOCK PER DETAIL 2, SHEET C-4.7 WITH SHACKLE RODS PER C.O.R. DET. 330.5, SHEET C-4.7. 7 O 1 - 2" IRRIGATION SERVICE 1 - 2" GATE VALVE (THREADED) 1 - 12 GATE VALVE (MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 19 1 - 6" 90° BEND (MJ) WITH THRUST BLOCKING STA: 21+20.44 O 2 RECORD DRAWINGS 0 2 RECORD DRAWINGS �p Q 1 RECORD DRAWINGS \� e NO. REVISION SURVEYED: Z.NALL DESIGNED: J.GREEN NAVIX 09.29.22 JET NAVIX 06.10.22 JET DRAWN: J.GREEN NAVIX 05.17.22 JET CHECKED: J.TAFLIN BY DATE APPR APPROVED: J.TAFLIN SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF 1"R] RENTON Planning/Building/Public Works Dept. ■ 0 15 30 60 SCALE: 1 inch = 30 ft. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RESTRAINT SERIES 1100 RESTRAINED (OR APPROVED EQUAL) AND CONCRETE BLOCKING PER COR STANDARD PLANS rJ 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com " I -- BE , WA itally sign y nelle T flin Date: 2022.09.3 A 418726:3;Z:09-0 m ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. NAVIX CERTIFICATION W-412302 BY IN COMPLIANCE WITH CITY OF RENTON STANDARDS LAI O N O O z 0 F- z LU w ARCO/M U RRAY DATE:09.26.2022 J TOPGOLF RENTON O OOK: 780 LOGAN AVENUE NORTH PAGE: PAGE: DRAWING N0. RENTON, WA 98057 C-4.1 a0 WATER PLAN SHEET: 50 0F: 82