Loading...
HomeMy WebLinkAboutS-412302N � r ti N C I N z O z W LL J O O LH N N 0 N N Q a) U-) O L� G M 5 Q \ U U I� Ld i,i Z — SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SEE SHEET C-5.2 FOR CONTINUATION I U °° J SSCO #3 O 00 6 LF 6" PVC SSCO #2 I o + GREASE INTERCEPTOR OUTLET 0 N �000 33 LF 6" PVC D GREASE INTERCEPTOR INLET +D I ° I- 8+64 ° — WASTEWATER CONNECTION - — — — — _FD — — — (SEE PLUMBING PLANS FOR CONTINUATION) D o GREASE WASTE CONNECTION 0+ (SEE PLUMBING PLANS 10+31 — — FOR CONTINUATION) 7 LF 4" PVC `3x — ■ SSCO 4 o _ -� O # o + I O I _ ��PG D — LF 8" PVC I 406. SANITARY SEWER PIPE C-5.E • SANITARY SEWER CLEANOUTE SANITARY SEWER MANHOLE C 1 1500 GALLON GREASE INTERCEPTOR M ail L_ M F- — — — — — — — — � — — — — IS OG N as — ALL ALL ON -SITE SEWER PIPES, MANHOLES, CLEANOUTS, AND GREASE INTERCEPTOR ARE PRIVATELY OWNED AND MAINTAINED. SEE DETAIL 413, SHEET C-5.7 FOR CITY OF RENTON WASTEWATER UTILITY NOTES. O 2 RECORD DRAWINGS 0 0 2 RECORD DRAWINGS �p Q 1 RECORD DRAWINGS \� e NO. REVISION O L_� O O O O O O O ■ AVE N ,(„ M IT Q0 O 0-) N O Q0 O� N Ln ■� II ■ 0 15 30 60 SCALE: 1 inch = 30 ft. HAVIX 11235 s.e. 6th street suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com j 6ABBT ■ R� pY WASgI�� j itally sign y nelle T flin Date: 2022.09.3 0 418726:aUQ:08-0 r Cfl O O 1 O N ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR Z VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, a CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q S-412302 BY O V IN COMPLIANCE WITH CITY OF RENTON STANDARDS W z O F_ z NW Ii SURVEYED: Z.NALL SCALE: HORIZONTAL: NAD 1983/1991 DATUM o CITY OF RENTON � Planning/Building/Public Works Dept. ARCO/M U RRAY TOPGOLF RENTON 780 LOGAN AVENUE NORTH RENTON WA 98057 DATE: 09.26.2022 U. O a. O DESIGNED: J.GREEN NAVIX 09.29.22 JET PAGE:OOK: PAGE: NAVIX 06.10.22 JET DRAWN: J.GREEN ONE INCH DRAWING N0: C-5.1 NAVIX 05.17.22 JET CHECKED: J.TAFLIN AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE APPR APPROVED: SANITARY SEWER PLAN SHEET: OF: J.TAFLIN 59 82