Loading...
HomeMy WebLinkAboutT-412304SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. Z O I- Z W U. J 0 ( AAV 13. O I - E CU m ILIq 0 1 CV CV 0 CV ar o_ CD I� J U CV M 0 I L sn- CDL E 0 U O J C>3 0 Q cu a> 0 LL_ L (1) Tn 4' �Pi'lYv�41,� T' a1 iA W P 1 /4" LOAD FUSE LINE 1 /4" 1 /8„ I O CUTTING RINGS FUSE KIT CL7llVV CII I VY T t Jt'Lll.t SPLICE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON STANDARD PLANS 1ST DATE:04/04 .... nwr NAAAP" .Ills -i CP PAI;F• .I(11 i DocuSign Envelope ID: F41B6C7D-lA89-4D3E-83C3-E2FO224FAF96 POLE & BRACKET CABLE, #12 AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK REFER TO WSDOT LOCKING DISCONNECT 3 AMP IN LINE TO LUMINAIRE LID STANDARD DUTY FUSE KITS S.E.C. OR EQUAL JUNCTION BOX TYPES 1 & #8 GREEN INSULATED WIRE 2 STANDARD PLAN J-40.10 TO FIXTURE GROUND LUG GROUND LUG ---\ SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS--\ CONCRETE PAD OR SIDEWALK PER STD PLAN 120 rffi 24"(MIN) COVER v \ #8 BARE COPPER - GROUND WIRE GROUND II II CLAMP II I I 1 -#8 EQUIPMENT GROUND-]2" PVC CONDUIT II II IL_ -11 WIREW/GREEN INSULATION FROM SERVICE CABINET CONCRETE FOUNDATION 2 - LIGHTING SYSTEM 5/8"x8' COPPER CLAD WIRES TO CONTACTOR GROUND ROD (SIZED AS REQ'D.) NOTES: 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE OF THE SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. LUMINAIRE ELECTRICAL STD. PLAN - 119 PUBLIC WORKS WIRING SYSTEM AP OVED: rP DEPARTMENT F GAZ 5/22/2019 1 DATE DocuSign Envelope : 5 DocuSign Envelope ID: AOA08484-4OB8-4C5D-B9EO-E7OE51967ED2 TR E E _ DIRECTION OF TRAFFIC GENERDOW TEB: T STREET CURB AND e BDtZval STREET WPBAND P 5�, 1. OOAAMONN OECORAT VE PEDESTRIAN LUMINAIRES SHALL BE EOUPPED YAIIALL EOUVMEM SHOWN ON THISSHEET 7 MTE114DE00RATIVE FEDES7RM lWINARES SHaLI NOT C04F EQUIPPED WTH BANNERS MD ROWER BLSNE'AIONOFSIEIS PAINT SPECIFICATIONS: ALLIPMINTM POLE CAST ALUMIN$BASE PARTS . AID ANY ADAND DOWNTOWN LOCATIONS MDARTERIAL LOCATIONS SHILL BE PER J. ORIENTATION OFATION 7' - 0•� PO EQUIPMENT MOUNTED IS THE CQ_ORPOLESHAH BE FACTORY MIMED AND PONDER COATED TO MATCH FINISH COLOR. �, �, �, �. ETFOR ORIENTATION LOCATION DETAIL, SHEET 1 -6 1._6,I � 1._0,• LUMINAIRE POLE\ JUNCTION BOX CONCRETE PAD PLAN VIEW LUMINAIRE POLE CONCRETE PAD l'-6" 4" JUNCTION BOX _r�LUMINAIRE CONCRETE � FOUNDATION SIDE VIEW LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES: 1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS OUTSIDE OF SIDEWALK 2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL BE PER STD PLAN 135 3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELEVATION OR BOTTOM OF SIDEWALK ELEVATION 4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN 5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE I AND TYPE 2 JUNCTION BOXES ONLY V OOO FIE -On LUMINAIRE POLE JUNCTION BOX CONCRETE SIDEWALK PLAN VIEW PER STD PLAN 102 LUMINAIRE POLE CONCRETE SIDEWALK PER STD PLAN 102 JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WITH SIDEWALK DETAIL CONCRETE PAD �� I'-0'• JUNCTION BOX -�/ PLAN VIEW 4" i CONCRETE PAD JUNCTION BOX SIDE VIEW INDIVIDUAL JUNCTION BOX PAD DETAIL LUMINAIRE CONCRETE PUBLIC WORKS PAD/SIDEWALK AND "1�4D LAN -3 1132[0aTT�p DEPARTMENT JUNCTION BOX CONCRETE PAD Gregq A._ZmmeFrTl19 I 4 E _1 DocuSign Envelope ID: 5D308A1A-204D-48EB-BB23-8A2834BB565E GENERAL NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS(I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 7. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. 8. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. TRANSPORTATION NOTES STD. Pi" PUBLIC WORKS APPROVED: DEPARTMENT GAZ 3/13/2019 I DATE RECORD DRAWINGS NO. REVISION ALLBMOID ANOALLOIIERMO,APING HARCMARE SHALL MATCH FINISH C0.0R. P IO,a P 190, FM9HOOLOt RALDO5IX'ET BLACK' DOWNTCNM LOCATION A BARS, EVEMYSPAfID ORIENTATION NOTES DCWN'TGAN LOCATIONS OIEATATONNOTES ARTERVLLOGTIONS DECOATILE PEDESTRIAN LUMINAIRES LII:UNIEDAT • DECORATIVE PEDESTRIAN LUMINAIRES MOUNTED AT 0•.JLESSOINERYISENCIED ON PLANS IV UNLESS OTHERWISE NOTEDON PLANS hNOHOES MOATTFD AT LBO' • XNONOEB MOUNTED ATO' %� REGEPTAGLEMCAUNTEO AT IV RECEFTACLE.MATDUATO' CENTER CONDUIT DECORATIVE LUMNANE POLE NOTES CARREX CONDUIT MD IRRIGAT ON POLE LOCATED • CAPFLEX CONDUIT MD IRRIGATION HOLE LOCATED IN FOUNDATION m ROUND TUDUNI SECTION Ara AT IV • PLMTSUPP3IITBRACKETSI.gUMEDAT50•&M ING TAPER) (UNLESS OTHERWSE NOTED ON RANSI • BANNER MOUNTED AT IV 041R, UNLESS STATED OTHERBISEON ORIENTATION LOCATION DETAIL THEPLANS.STUBOUTI'FROMEDGEOF DOME SI LED LUMNNRE(WATTAGE PER PLANS, 4' ALUMINUM POLE TOP CAP W17N COEFETEFO3NDAANDCONNECTTOCRY TIOI JU40TION BOX PER STD RAN 119 TYPESTESDISTROLTION a03WCCT,Ix M UNIVERSAL OUVERRWA,A OR LOYER). WITH FLAT (3) SET SCREWS AT 12D' APART GLASS LENSI BY CYCLONE rOR APPROVED EDUALL DRIVER SHALL BE INTEGRAL TO THE FIXTURE SEE STD PLIA TIT 3, NOTE 3. FOR ARMLENGTHIS,AND FOR MOUKTING HARDWARE SEE DETALSSHOWN ON STD PLAN 117.3 u DOBNTOWNLOCATKNSONLY NfC A. HOES FOR BANNER, SECURE DOWNTOWN LD `nCNSDMY, (2) CECORATNE SIMMER BRACKETS WITH PRESSURE TOP BAAMER BRACKET WITH T4R000H RELEASE SPRINGS WITH BO.TS AMO SHIM TO.EVEL PER PROTECTIVE RUBBER COATING AVNU=ACTURER'S INSIRUCTION6� STREET LIGHT STANDARD DECK NUMBERING PER S7D PL14121 DOVTTCWN LOCATIONS ONLY. 7,4'DECDRATNEBANNER EICERNAL FESTOON CASTING NTH ICOKAB-E DIE CAST NEW, 3R LOCIBNO. DOWNTOWN LOCATIONS ONLY. PALATABLE, Y•FATHERPROOF, 111119E l DECORATIVE BANNER ARM COVERT MODEL YRpMG B WITHFINAL NTERLMTIL IOR APPROVE101D EQUAL)Y - - - - - - - - MOUNTEDTO GFCI RECEPTACLE. PLANT TO WTCH POLE TASREINFORCEDALUMINUMORIP ACCESS HMDHOLE OPENING AND DOWNTOWN LOCATIONS ONLY. FLUSH FITTING ALUMINUM DOOR 1YITH BECURERCTTOM7NRACIET SAERB GASKETLOCNTEDAT'O' WITH 3 ADJUSTABLE STAINLESS STEEL BAVOS AND SHIM TO'.EVEL PER NUWU=ACTURER'S MSTid1CTIONS DOWMOWN LOCATIONS ONLY DECORATIVE ROWER BASKET AND ARus PER STD PIN nTA ,• DM IRRIGATION TLIBNG HOLE TAPERED POLE SHAFT FABRICATED FROM eDS3 IN TUBE (POLE ASSEMBLY4EKT TREATED i5 COND RpN AFTER BELONG) B'OD.. 250'WNL - TOP OF BASE ACCEPTING S STRAIGHT ROUND POLE SECTION. INSTALL m RUBBER GASKET AT TOP OF BILE T . 5' PEINFORCED ALUMINUM W 6 NONE MR CONNECTOR� T033EMA%FROM FACEOFCURSM DOCIARUSNFITIING� GASIQET k FACE OF CURS, IF SURFACE 15 NOT LEVEL. INSTALL GROUT AT BASE OF POLE AND J WE COVER, MOVES 1?OM ORAN TUBE THROUGH GROIT JJ ASTMT55 SPLNTCASTALUMINUMBASE, 1'17 TALE WITH 4'A S• REMOVABLE ACCESS DOpi. STDRM1,1A FON ADDITIONAL DEDETALS FABRICATED ALUMINUM BASE PLATE e ASSEADLY DER STD RAN I I74 1] TOP ST PADLNOB / CONCRETE AO POLE ELEVATION COIICRETE PM OR SIDEWNK >EA sro RAN Ix FOUNDATION T N HOOPS *IT FOUNDATION SECTION FOUNDATION DETAIL ,-RE'LXA1,10 HYPO W STEEL PLAN BOLT CIRCLE PER STD MN I174 T / ANCHOR BOLT TEMPLATE DETAIL roPoc 1-015MIION NN HORBOLT A IDTAL, I'DIA, GALVMLTED STEEL F155AORGRIDE SSITVP)� I' HEX NUTS, STEELIB REOUPER ANCHOR BOLT).- FLATl4ASHFASIBgEODPEAANCNORBOr ANCHOR BOLT ASSEMBLY DETAIL ARTERIAL & DOWNTOWN STREET PUBLIC WORKS DECORATIVE PEDESTRIAN DEPARTMENT LUMINAIRE POLE DETAILS �FNiO� INSTALL DECAL NUMBERS VER71CALLY. INSTALL EN DRY WEATHER, 50' F OR ABOVE NLIMBERPVG / 2 EXAVO'I.ES / 3 ! 4 C s 6 17 WATTAGE 4J LL Ln L- LD W z z CD PLAN VIEW FORM PLAIN 117.1 FOR MD MAN 116.1,117.$117.4 3 4" TO 2" 0.88" Lew 1_4 G `co ' ^ o - I ' DECAL: RE LECIORIIZED GOTHIC GOLD OR WHITE LEGEND ON BLACK BACKGROUND I S-REET LIGHT STANDARD STD. PLAN- 121 PUBLIC WORKS DECAL NUMBERING SYSTEM A PR01' DEPAR"MiNT OA SURVEYED: DEEIENED BTATE DRAwv: B.PATE F D 09/19/22 CHECKED: F.DERAS BY DATE A P P R I APPROVED: SALE' VERTICAL: NAVD 1988 NO SCALE HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ). PLAN - 117.2 n .astuchetl/5/2020 D98B449D... DATE Ao"u CITY OF 1V!4r;URj1FJF R ENTON Planning/Building/Public Works Dept. F26 FSG 2525 WALNUT HILL LANE SUITE 100 DALLAS, TX 75229 PH: 214-357-5697 FAX: 214-357-5794 WWW.FSGI.COM 09.19.2022 T-412304 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ARCO/MURRAY - TOPGOLF RENTON 780 LOGAN AVENUE NORTH RENTON, WA 98057 SITE LIGHTING PLANS z O z NW IEEt• 04.17.2020 ALL J �0 V S L4 a 1 O 79 82 i