Loading...
HomeMy WebLinkAboutR-418503AS —BUILT SET LO 00 T W I- &I, a ° as F1 a a 4 a 4. a a a as 4 a °- ° a a ° a 4 a ° Q HORIZONTAL CONTROL PLAN NOTE: INFORMATION FOR AS -BUILT DRAWINGS SUPPLIED BY GENERAL CONTRACTOR. 14/S -'- V G SrON, i6.65' � 1 r x 10, CV 7.33' II II II-4'—HI III CD N X X X X X X x X]IU7 — X — X �X- X Cn Ci 8 9 10 11 12 19.1' 7.33' eo v X X X X X X - - x X x X— X— X_ X_ X_ X j Ci 25 26 27 28 29 30 co F- 4=11 N Q b S2rF7T GRAPHIC SCALE 20 0 10 20 40 ( IN FEET) 1 inch = 20 ft. CCD #6 JSB 07/30/21 SURVEYED: TJ K DESIGNED: JSB DRAWN: JSB CHECKED: RCJ NO. REVISION BY DATE APPR APPROVED: BDA 80 SCALE: AS NOTED ER 0 40 41 a NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION A THEIR COST. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK. NOTE: CONTRACTOR RESPONSIBLE FOR AS -BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. AS-BUILTS SHALL BE SIGNED AND CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER. GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NAD 19 IFICA • NAVID 1988 HORIZONTAL 1 CITY OF ICo RENTON DATUM M Planning/Building/Public Works Dept. KEY MAP NOT TO SCALE SITE LEGEND EXISTING BUILDING TO REMAIN ® EXISTING BOLLARD TO REMAIN —X X EXISTING FENCE TO REMAIN EXISTING CURB & GUTTER TO REMAIN ® ® EXISTING STORM INLET TO REMAIN EXISTING SIGN TO REMAIN -Ell EXISTING SITE LIGHTING TO REMAIN o-� EXISTING SITE LIGHTING TO BE RELOCATED so EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING FIRE HYDRANT TO BE RELOCATED PROPOSED FIRE HYDRANT >a EXISTING IRRIGATION VALVE TO REMAIN EXISTING CONCRETE PAVEMENT P EXISTING ASPHALT PAVEMENT JI PROPOSED CONCRETE PAVEMENT PROPOSED ASPHALT PAVEMENT SEAL COAT TO REMOVE EXISTING STRIPING FOR NEW PICKUP STALLS AND ASSOCIATED PARKING STALL MODIFICATIONS. EXISTING ASPHALT TO BE REMOVED = PROPOSED PICK-UP SIGN PROPOSED CURB AND GUTTER CAUTION — NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE 00 ,)� TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE o CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR Know whaVsbeI ow. PRIVATE, WHETHER SHOWN ON THE PLANS OR C C I I before you dig. NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. _ �OF WAS 56606 ss�oh'ALG A 08/31 /2023 z O R-41850 co z IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q 0- X /W I..L U_ n #2516 DAMWALMART 7/29/2021 WALMART SUPERCENTER PICKUP EXPANSION FIELDBOOK:B00K CONSTRUCTION DOCUMENTS PAGE: PAGE DRAWIN HORIZONTAL CONTROL PLAN G 2.2 Q SHEET: 5 OF:17