HomeMy WebLinkAboutR-41851500
v
CONSTRUCTION
AREA
A
L
FLOW
``•tit"y'•..H+,
I
I
H-r.;.,w
E
. APRON .;
�•:.�.-i!
. . O.
sn' I
I p'
r. :0'7„
N
N
hJ4.`Y.yJ.
y
2
NS
1
1
.
IN Alt'3
z ell
FAn�.4R' !.�,
i
^
r�•'.•
I
I
.ADHERIVU
;•. • sC r.
ERA
M.
DIKE PLAN VEIW
NOTES:
1. INSTALLED SILT DIKE UNIT
SHALL HAVE CONTINUOUS AND
FIRM CONTACT WITH PAVEMENT.
APRON ON THIS
SIDE OF THE DIKE
SHALL BE FOLDED
UNDER THE DIKE
SECTION 20" AND
GLUED DOWN
Al
J
OVERLAP PER
MANUFACTURER'S
RECOMMENDATIONS
2. ADHESIVES SHALL BE LIQUID
NAIL OR APPROVED EQUAL FOR
CONCRETE PAVEMENT
APPLICATIONS AND EMULSIFIED
ASPHALT FOR ASPHALT
APPLICATIONS.
ADHESIVE SHALL BE PLACED
WHERE THE UNITS OVERLAP AND
A 20" STRIP ALONG BOTH EDGES.
EXISTING CONCRETE OR
FLOW + ASPHALT PAVEMENT
Of a. ..0 Jn '. J•u. ... .. M•'•u•'N J• uu..
ADHESIVE SECTION A -A `ADHESIVE
SILT DIKE
DP (ON EXISTING PAVEMENT)
Wu
WIRE MESH
--
CONCRETE BLOCKS
00'
KOS'
j
".
yFILTERED
_
SEE NOTE
WATER
00'
000,
RUNOF
a
FINISHEDGRADE
GRATED INLET
GRATED INLET
AGGREGATE
GORE El
PLAN
SECTION
NOTES
1. PLACE CONCRETE BLOCKS INA SINGLE ROW AROUND PERIMETER OF INLET ON THEIR SIDES, WITH ENDS OF ADJACENT
BLOCKS ABUTTING.
2L HEIGHT OF BARRIER NAMES. USE STACKS OF 4', SE, OR 12'BLOCKS. MIN. HEIGHT OF BARRIER SHP BE 1T AND MAX.
HEIGHT SHALL BE 24'.
3. PLACE HARDWARE CLOTHWIRE MESH W/MAX. LT OPENINGS OVER VERTICAL FACE OF CONCRETE BLOCKS.
4. ME AGGREGATE SHALL BE SEE T ANGULAR CLEAN STONE, WHICH WILL SLOW THE FLOW OF THE WATER AND ALLOW IT TO
FILTER THROUGH AND OVER ME MATERIAL BEFORE ENTERING ME INLET.
MAINTENANCE NOTES:
1. INLET PROTECTION DEVICES MUST BE INSPECTED FOR SEDIMENT ACCUMULATION WUMN ME CATCH BASIN (IF USING
INSERT -TYPE DEVICE) OR UPGRADIENT OF THE INLET
2. REMOVAL OF SEDIMENT ACCUMULATED IN OR ADJACENT TO A STORM DRAIN INLET MUST BEGIN IMMEDIATELY UPON
DISCOVERY, WITH COMPLETION OF THE ACTIVITY OCCURRING NO LATER MAN THE ENO OF THE FOLLOWING BUSINESS DAY.
3 INLET PROTECTION DEVICES SHALL BE INSPECTED FOR UNINTENDED BYPASS OR IMPROPER FLOW -RATES THAT MY
CAUSE DOWNSTREAM FLOODING.
4. CONTACT THE DEC FOR ALTERNATE INLET PROTECTION IF TIE DESIGNED PROTECTION MAY IMPACT DOWNSTREAM BOPS,
ADJACENT SLOPES. ETG, DUE TO PENDING ISSUES. ENSURE THAT NO UNDERMINING OF INLET PROTECTION DEVICES HAS
OCCURRED,
5. INLET PROTECTION DEVICES AND BARRIERS SHALL BE REPAIRED OR REPLACED IF THEY SHOW SIGNS OF UNDERMINING OR
DETERIORATION.
8BLOCK AND AGGREGATE INLET PROTECTION
8
TS.
CONCRETE A
BLOCKS AGGREGATE
00
00
Ll
00
0.0
010 10
00
10
10
GUTTER
WIRE MESH CURB
CURB INLET
A
PLANWIRE MESH MAINTAIN
MAINTAIN ACCESS TO COVER
FOR INSPECTION
CONCRETE BLOCKS FILTERED WATER
CURBINLET
ERuxVF y `'
z
AGGREGAT
CONCRETE GUTTER
SUB -GRADE
SECTION A -A
NOTES:
1. PLACE CONCRETE BLOCKS IN A SINGLE ROW AROUND PERIMETER OF CURB INLET ON THEIR SIDES. WITH ENDS OF
ADJACENT BLOCKS ABUTTING.
2. HEIGHT OF BARRIER VARIES. USE STACKS OF 4',8', OR 12-BLOCKS. TOP OF BARRIER MUST BE LOWER THAN TOP
OF CURB ELEVATIONS ADJACENT TO INLET. MAX. HEIGHT SHALL BE 24".
3. PLACE HARDWARE CLOTHNJIRE MESH W/MA)L 12 OPENINGS OVER VERTICAL FACE OF CONCRETE BLOCKS.
4. THE AGGREGATE SHALL BE 3W-T'ANGULAR CLEAN STONE WHICH WILL SLOW THE FLOW OF WATER AND ALLOW IT
TO FILTER THROUGH AND OVER THE MATERIAL BEFORE ENTERING THE INLET
5. IF ROAD OR PARKING AREA IS OPEN TO PUBLIC, VERIFY SUITABILITY OF BMP WITH AGENCIES HAVING JURISDICTION
AND WITH DEC.
AMINTENANCE NOTES:
1. INLET PROTECTION DEVICES MUST BE INSPECTED FOR SEDIMENT ACCUMULATION WITHIN THE CATCH BASIN (IF
USING INSERT -TYPE DEVICE) OR UPGR UMENT OF THE INLET.
2. REMOVAL OF SEDIMENT ACCUMULATED IN OR ADJACENT TO A STORM DRAIN INLET MUST BEGIN IMMEDIATELY
UPON DISCOVERY. WITH COMPLETION OF THE ACTIVITY OCCURRING NO LATER THAN THE END OF THE FOLLOWING
BUSINESS DAY.
3. INLET PROTECTION DEVICES SHALL BE INSPECTED FOR UNINTENDED BYPASS OR IMPROPER FLOW -RATES THAT
MAY CAUSE DOWNSTREAM FLOODING.
4, CONTACT THE DEC FOR ALTERNATE INLET PROTECTION IF THE DESIGNED PROTECTION MAY IMPACT DOWNSTREAM
BOPS, ADJACENT SLOPES, ETC., DUE TO PENDING ISSUES. ENSURE THAT NO UNDERMINING OF INLET PROTECTION
DEVICES HAS OCCURRED.
5. INLET PROTECTION DEVICES AND BARRIERS SHALL BE REPAIRED OR REPLACED IF THEY SHOW SIGNS OF
UNDERMINING OR DETERIORATION.
Pz BLOCK AND AGGREGATE CURB INLET PROTECTION
N.T.G.
SOURCE BOX
LAST REVISED: WAL-MART
STANDARD
OCTOBER 2012 DETAIL
SC-5 Rock Sock (RS)
1S" (WINDS)
CRUSHED RCGK 8ENCLOSED IN WIRE MESH Y fMINJSI CRuslf➢ ROCK
fp Ifsl
WIRE TIE ENDS 1
:T
o'A Cry SURFACE
r x OR GROUND SURFACE L D=. sE
aD SuaFACE, c UEPENoINC
IN so1L ON EE O
SEDIMENT
LOAM
ROCK SOCK SECTION ROCK SOCK PLAN
MY GAP AT JOINT SHALL BE FILLED WITH AN ADEQUATE
AMOUNT OF IS' (MINES) CRUSHED ROCK AND WRAPPED
WITH ADDITIONAL WIRE MESH SECURED TO ENDS OF ROCK
ROCK SOCK. reDrvfORCED SOCK. AS AN ALTERNATIVE TO FILING UPSETS
MR BETWEEN ADJOINING ROCK SOCKS WITH CRUSHED ROCK AND
1'Y IY ADDHIONAL MARE WRAPPING, ROCK SOCKS CAN BE
OVERLAPPED ("ICALLY 12-INCH OVERLAP) TO AVOID CMS,
1. SEE PUSH KIDS FOR'.
-LOCATION(S) OF ROCK SOCKS.
LExmnn)n TABLE
&ESE WE
M0.55 PERCENT PASSING
SQUARE MESH 51EVE5
x0. 4
2
ICE
vC
90 - 100
20 - 55
$'
0 - 15
MATCHES SPECIFICATIONS FOR No. 4
COARSE AGCREGATE FOR CONCRETE
RISE MSHTO RHO ALL ROCK SHALL BE
FRACTURED FACE, ALL SIDES.
2. CRUSHED ROCK SMALL BE Ih- (MINUS) IN SIZE WITH A REACTORS) FACE (ALL SIDES)
AND SHALL COMPLY WITH GRADATION SHOWN ON MIS SHEET (IX. MUM),
J. WINE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESTL OR EQUIVALENT WITH A
MAXIMUM OPENING OF X-, RECOMMENCED MINIMUM ROLL WIDTH OF M'
4. WINE MESH SHALL BE SECURED USING 'HOG RINGS" OR WIRE TEA AT B' CENTERS
ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OP SOCKS.
5. SOME MUNICIPALITIES MAY YLLON LIFE USE OF FILTER FABRIC AS AN AUIE9MIBE TO WINE
MESH FOR ➢E ROCK ENCLOSURE,
RS-1. ROCK SOCK PERIMETER CONTROL.
RS-2 Urban DLainage and Flood Control District Novemba:2010
Utbm Storm Dmivage Criteria Mem1a1 Vo11we 3
1 ' • '
:
NOTE:• " •' TO COMPLETETABLE• PROJECT SCHEDULE
m�EYIE�EII•il®®�®��
1WITH
'®m�RYYEm�®®�®��'®
�EEI��
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
SEDIMENT CONTROL BASlN(SNClU%PUSA
1111111111111111111111111111111.111111111111111111111111111111111111111111111111111111■■■111111111111111111■111111111111
STRIP IT STOCKPILE TOPSOIL
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
ROUGIAGRAIDING
STORMI■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■
SITE CONSTRUCTION
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
PERMANENT CONTROL STRUCTURES
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
FOUNDATION IBUILDING CONSTRUCTION
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
1) CONTRACTOR MUST COMPLETE TABLE WITH ESTIMATED DATES
2) TIME SCHEDULE MUST COINCIDE WITH THE SWPPP IMPLEMENTED
R-418515
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
Scott Warlick 8/30/2021
TJK fRR "°f'�fL"1 CITY OF WALMART#2516 D%
Am AS NOTED
JSB WALMART SUPERCENTER PICKUP EXPANSION ""
MB RENTON CONSTRUCTION DOCUMENTS M.
DATUM �sR
amn CJ Plonning/Building/Public Works Dept. EROSION AND SEDIMENT CONTROL PLAN NOTES AND DETAILS
NO. REVISION BY DATE APPR ANO BDA see
►n