HomeMy WebLinkAboutW-418502AS -BUILT SET 00 T I W I- 00 T N U-) M W T N I n r1r M N O N co U N CD 0 z rn 3 0 a a� 0 3 U I N Q 2 K O / 0 0 U rn 0 0 0 N In N 0 0 O L C O 0 3 Q / r w zz J STS STA=0+50.29 12" - 90° BEND N:175647.66 E:1297123.201 a�� 12" DIP 15.66 LF i SCF _ -G STA 0+40.20, i 12"X6"-TEEW/J% FLXMJ GATE VALVE (MJXFL) N:175632.011 J E:1297122.71 N N N \S STA=0+05.00 TS 12" - 90° BEND N:175602.40 E:1297121.77-A' a a -- a STS I / 8 -12" DIP 10.73 LF STA=1+81.21 12" DIP 92.90 LF 12" DIP 27.29 LF 12" - 90° BEND =STA 0+76.04----------------- _ N:175644.83__09 _ STS E:1297254. CROSSING 1+00 I -w w ,0+75.48 ST-S - -- - --- ----,3 ' ----- 9 -- -_- --- CV - LILTA 2I+V03.16/� Yd I - /I II _ � OSSING STA 1+23.04 FIRE HYDRANT MOVED 25SOUTH ROSSIN DUE TO UTILITY CONFLICT ' SING Cq c> 6" DIP 26.09 LF 0 BLDG FIFE=27.55 STA=2+42.16 I - - - 12"R S- 90° BEND- - - - - -r N:175583.89 � E:1297252.77 %- I -------------------------------------- ----- WATER IMPROVEMENTS PLAN SCALE: 1" = 20' A WATER IMPROVEMENTS PROFILE (STA: 0+00 - 2+47) O O 0 CCD #6 fie\ CCD #8 NO. I REVISION A \S � TS 7 c� W W W G STA 0+20.83 / CROSSING lSTA 0+21.47 FIRE X HYDRANT �o o CR03.09G 2.5' SOUTH DUI STA=0+05.00 UTILITY CONFL 12" X 6" - TEE W/ STA=0+31.09 FLXMJ GATE VALVE (MJXFL) FH ASMBLY N:175632.011 N:175631.18 E:1297122.71 E.1297148.78 6"DIP 26.09LF ------ --- \ zyt-- -W -W FIRE LATERAL PLAN SCALE: 1" = 20' 30 30 c� Z U) U) W CD +I co CD N M + F N N M � II II II F F-00 m F_ -CO FINISHED GRADE F:E:m D 25025 5 N O � m - a JSB 07/30/21 SURVEYED: JK MIMIC 10/14/21 DESIGN JSB DRAWN: JSB CHECKED: RCJ BY DATE APPR APPROVED: BDA SCALE: AS NOTED MOVED :TO CT GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION A THEIR COST. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK. NOTE: CONTRACTOR RESPONSIBLE FOR AS -BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. AS-BUILTS SHALL BE SIGNED AND CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER. NOTE: INFORMATION FOR AS -BUILT DRAWINGS SUPPLIED BY GENERAL CONTRACTOR. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE 0 TIME OF SURVEY AND IS TO BE CONSIDERED AN 0 APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR Know whaYsbeIow. PRIVATE, WHETHER SHOWN ON THE PLANS OR Call before you dig. NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. ja# WASjj 3 % CITY OF RENTON Planning/Building/Public Works Dept. KEY MAP NOT TO SCALE SITE LEGEND EXISTING BUILDING TO REMAIN ® EXISTING BOLLARD TO REMAIN X X EXISTING FENCE TO REMAIN EXISTING CURB & GUTTER TO REMAIN ® EXISTING STORM INLET TO REMAIN EXISTING SIGN TO REMAIN o-� EXISTING SITE LIGHTING TO REMAIN o-� EXISTING SITE LIGHTING TO BE RELOCATED so EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING FIRE HYDRANT TO BE RELOCATED PROPOSED FIRE HYDRANT �a EXISTING IRRIGATION VALVE TO REMAIN ►� PROPOSED WATER VALVE II I PROPOSED WATER BEND EXISTING CONCRETE PAVEMENT p e EXISTING ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT - JI PROPOSED ASPHALT PAVEMENT r PROPOSED PICK-UP SIGN PROPOSED CURB AND GUTTER PROPOSED SAWCUT LINE PROPOSED EASEMENT UTILITY LEGEND W- EXISTING WATER LINE TO REMAIN -W- EXISTING WATER LINE TO BE REMOVED W PROPOSED WATER LINE - SS EXISTING SANITARY SEWER PROPOSED SANITARY SEWER SS STS PROPOSED STORM SEWER TO REMAIN - -STS- PROPOSED STORM SEWER TO BE REMOVED STS PROPOSED STORM SEWER G EXISTING GAS LINE R-418513 S-418502 Z 0 W-418502 Z IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q 0- X ^Lu I..L i U_ 0- WALMART #2516 07/29/2021 WALMART SUPERCENTER PICKUP EXPANSION FlELDBOOK:BOOK Q CONSTRUCTION DOCUMENTS DRAWING NO: WATER PLAN & PROFILE 0 C6. Q of