J
STS
STA=0+50.29
12" - 90° BEND
N:175647.66
E:1297123.201
a�� 12" DIP 15.66 LF i SCF _ -G
STA 0+40.20,
i
12"X6"-TEEW/J%
FLXMJ GATE VALVE (MJXFL)
N:175632.011 J
E:1297122.71 N
N
N
\S STA=0+05.00
TS 12" - 90° BEND
N:175602.40
E:1297121.77-A'
a
a
--
a
STS I
/ 8
-12" DIP 10.73 LF STA=1+81.21
12" DIP 92.90 LF 12" DIP 27.29 LF 12" - 90° BEND
=STA 0+76.04----------------- _ N:175644.83__09
_
STS E:1297254.
CROSSING 1+00 I
-w w
,0+75.48 ST-S - -- - --- ----,3
'
----- 9 -- -_- --- CV - LILTA 2I+V03.16/�
Yd
I -
/I
II _ �
OSSING STA 1+23.04
FIRE HYDRANT MOVED 25SOUTH ROSSIN
DUE TO UTILITY CONFLICT
' SING
Cq
c>
6" DIP 26.09 LF 0
BLDG FIFE=27.55 STA=2+42.16 I - - -
12"R S- 90° BEND- - - - - -r
N:175583.89
� E:1297252.77
%- I
-------------------------------------- -----
WATER IMPROVEMENTS PLAN
SCALE: 1" = 20'
A
WATER IMPROVEMENTS PROFILE (STA: 0+00 - 2+47)
O O 0 CCD #6
fie\ CCD #8
NO. I REVISION
A
\S �
TS
7
c� W W W
G STA 0+20.83 / CROSSING lSTA 0+21.47 FIRE X HYDRANT
�o o CR03.09G 2.5' SOUTH DUI
STA=0+05.00 UTILITY CONFL
12" X 6" - TEE W/ STA=0+31.09
FLXMJ GATE VALVE (MJXFL) FH ASMBLY
N:175632.011 N:175631.18
E:1297122.71 E.1297148.78
6"DIP 26.09LF ------ --- \
zyt-- -W
-W
FIRE LATERAL PLAN
SCALE: 1" = 20'
30
30
c�
Z
U)
U)
W CD +I
co
CD
N M
+
F N N M
�
II II II
F
F-00
m F_
-CO
FINISHED
GRADE
F:E:m
D
25025
5
N
O
�
m -
a
JSB
07/30/21
SURVEYED:
JK
MIMIC
10/14/21
DESIGN JSB
DRAWN:
JSB
CHECKED:
RCJ
BY
DATE
APPR
APPROVED:
BDA
SCALE:
AS NOTED
MOVED
:TO
CT
GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING
PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF
BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME
HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS.
PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND
ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK.
NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR
SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION A
THEIR COST.
NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO
BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO
COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK.
NOTE: CONTRACTOR RESPONSIBLE FOR AS -BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY
OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY,
UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. AS-BUILTS SHALL BE SIGNED AND
CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER.
NOTE: INFORMATION FOR AS -BUILT DRAWINGS SUPPLIED BY GENERAL CONTRACTOR.
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON
MAPS PROVIDED BY THE APPROPRIATE UTILITY
COMPANY AND FIELD SURFACE EVIDENCE AT THE 0
TIME OF SURVEY AND IS TO BE CONSIDERED AN 0
APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE LOCATION OF ALL UTILITIES, PUBLIC OR Know whaYsbeIow.
PRIVATE, WHETHER SHOWN ON THE PLANS OR Call before you dig.
NOT, PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND
VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH
POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
ja# WASjj
3
% CITY OF
RENTON
Planning/Building/Public Works Dept.
KEY MAP
NOT TO SCALE
SITE LEGEND
EXISTING BUILDING TO REMAIN
®
EXISTING BOLLARD TO REMAIN
X
X
EXISTING FENCE TO REMAIN
EXISTING CURB & GUTTER TO REMAIN
®
EXISTING STORM INLET TO REMAIN
EXISTING SIGN TO REMAIN
o-�
EXISTING SITE LIGHTING TO REMAIN
o-�
EXISTING SITE LIGHTING TO BE RELOCATED
so
EXISTING STORM SEWER MANHOLE TO REMAIN
EXISTING FIRE HYDRANT TO BE RELOCATED
PROPOSED FIRE HYDRANT
�a
EXISTING IRRIGATION VALVE TO REMAIN
►�
PROPOSED WATER VALVE
II I
PROPOSED WATER BEND
EXISTING CONCRETE PAVEMENT
p e
EXISTING ASPHALT PAVEMENT
PROPOSED CONCRETE PAVEMENT
- JI
PROPOSED ASPHALT PAVEMENT
r
PROPOSED PICK-UP SIGN
PROPOSED CURB AND GUTTER
PROPOSED SAWCUT LINE
PROPOSED EASEMENT
UTILITY LEGEND
W-
EXISTING WATER LINE TO REMAIN
-W-
EXISTING WATER LINE TO BE REMOVED
W
PROPOSED WATER LINE
- SS
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
SS
STS
PROPOSED STORM SEWER TO REMAIN
- -STS-
PROPOSED STORM SEWER TO BE REMOVED
STS
PROPOSED STORM SEWER
G
EXISTING GAS LINE
R-418513
S-418502 Z
0
W-418502 Z
IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q
0-
X
^Lu
I..L
i
U_
0-
WALMART #2516 07/29/2021
WALMART SUPERCENTER PICKUP EXPANSION FlELDBOOK:BOOK Q
CONSTRUCTION DOCUMENTS DRAWING NO:
WATER PLAN & PROFILE 0 C6. Q
of