Loading...
HomeMy WebLinkAboutR-418317M 00 T T r•1 J 0_ O 2 U) 0 z_ 0 z Q J Cn C7 Call ] Working Days Before You Dig 811 tilities Underground Location Cente (ID,NT,ND,OR,WA) LUMINAIRE SCHEDULE LUM. NO. POLE x ID. NO. CIRCUIT NO. LOCATION GPS COORDINATES OFFSET (FEET) LED LAMP WATTAGE MAST ARM (FEET) MOUNTING HGT(FT) STANDARD PLAN # FIXTURE TYPE 1 5094A44 A HOQUTAM AVE NE 7+39 22.5' RT 44 NA 14' 1161 NEIGHBORHOOD PEDESTRIAN 2 5095A44 A HOQUTAM AVE NE 8+36 22.5' RT 44 NA 14' 116.1 NEIGHBORHOOD PEDESTRIAN 3 5096A44 A HOQUTAM AVE NE 9+58 22.5' RT 44 NA 14' 116A NEIGHBORHOOD PEDESTRIAN 4 5097A44 A NE 2ND ST 19+53 22.5' LT 44 NA 14' 116.1 NEIGHBORHOOD PEDESTRIAN 5 509BA44 A NE 2ND ST 18+47 22.5' LT 44 NA 14' 116.1 NEIGHBORHOOD PEDESTRIAN x NOTE: GPS COORDINATES TO BE ADDED ON AS -BUILT DRAWINGS III IpID °I r IIIIIIIIII�( III II III el IIIIIIIID�' I 1 60 LEGEND LED PEDESTRIAN LUMINAIRE AND DECORATIVE POLE ROADWAY LUMINAIRE - - - - - PVC CONDUIT (SEE WIR+NG SCHEDULE) 19 TYPE 1 JUNCTION BOX WITH CONCRETE PAD ® SERVICE CABINET WIRE NOTE O CONSTRUCTION NOTE CONSTRUCTION NOTES OINSTALL NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 1161, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 2 AND 3, AND LUMINAIRE POLE SCHEDULE, MINIMUM SEPARATION FROM DRIVEWAY EDGE TO STREETLIGHT FOUNDATION EDGE IS 10 FEET. OCONNECT CONDUCTORS TO NEW CIRCUIT IN THE EXISTING ELECTRICAL SERVICE CABINET, PULL CONDUCTORS THROUGH EXISTING AND NEW JUNCTION BOXES AND CONDUITS TO NEW LUMINAIRES, COORDINATE WITH C.D.R. ERIC CUTSHALL, TRANSPORTATION MAINTENANCE MANAGER 425-430-7220 FOR SERVICE INSPECTION, CONNECTION TO BE MADE BY THE CONTRACTOR AFTER INSPECTION, O INSTALL TYPE I JUNCTION BOX PER STANDARD PLANS. WIRING SCHEDULE -ONI)Ull CONDUIT CONDUCTORS NOTES RUN SIZE 1 2.0" PVC (SCHEDULE 40) 2-#8, 1-#8 GREEN 2 EXISTING CONDUIT 2-#8, 1-#8 GREEN 2.W PVC (SCHEDULE 40) 3 2.0" PVC (SCHEDULE 80) 2-#8, 1-#8 GREEN REQUIRED INSPECTIONS FOR STREETLIGHTING ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS AND CABINET FOUNDATION CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL PHONE # 425-430-7220 FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING FOLLOWING TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR ELECTRICAL CONTRACTOR SHOULD SUBMIT APPLICATION TO ESE TO ENERGIZE THE STREETLIGHTING ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREELIGHTING HAS BEEN ENERGIZED GREEN'S LANDING SHORT PLAT 5008 NE 2ND STREET RENTON, WASHINGTON 98055 ILLUMINATION PLAN `a W 0 N U Q J a 0 2 0 Z_ 0 Z J Z W W tr C'3 a y T-418301