Loading...
HomeMy WebLinkAboutzW-4116Set'S T. of -900 BEND (MJxMJ) ' 60NGBLOCK E SPOOLS AS REQ �/4" WATER METER (BY CITY FORCES) GUT AND CAP EX. 6" W CI (BY CITY FORCES) W(E)-. W(E)� waE� SO(1� 300 BRONSON WAY.DCDA NORTH IRR, DW, FW S VICE: BACKFLOW PREY OCATED INSIDE BUILDING. FW:4 ER 360.5) 2" IRR, DW SERVICE DW' p^ DCVA METERS PER STD 320.2 IRR: 1-112 RPBh ER 340.8) (CITY TO PROVIDE METERS) SEE PLU ND FIRE PLANS IN BUILDING PERMIT SET ABANDON 3/4' REMOVE EX. 6" W CI NON -SLIP LIDS 2"IRR SERVICE SEE LARCH ( ) WATER METER BY CITY FORCES ( ) FROM STA 21+62.46 TO STA 25+58.73 STA 22+85.30, 22.42 LT (DW) 2" DW SERVICE STA 22+g3.80, 22.42 LT (IRR) ABANDON 314" 6" FW-DIP PIV TO BE FDC W/CONN. IN WATER METER ABANDON 3l4" WATER METER SUPERVISED POST INSTALLED AWAY BLDG BY PLUMBING ` (BY CITY FORCES) (BY CITY FORCES) INDICATING VALVE FROM FACE OF STA 24+33.10, 30.98 LT PER STD 360.5 BUILDING PER STD PLAN 360.5 _ ..-.._- -� v 3313 3sd 33�3 3sd ---.--__-_.--.--._..-.. ..-_- 60 - 41.60� ABANDON 4 2 _ 8" W WCE; ,,, � �n w,r, ^ �;...�.- _ CITY FORCES): --W"CITY-+[�'-8 8"xB"TEE(MJxFL) ®"'•'I�"" 8" GV (FLxMJ) 2-8" SLEEVES (MJ) '> 12"W TEE (MJxFL) CONIC. BLOCK 8" GV (FLxMJ) PER STD PLAN N0.300.2 ,;: CONIC. BLOCK STA 21+60.97, 14.00 LT 12" VERT. CROSS ---"-"-"-"SEE NOTE#8 FOR POLYPIGGII�G--- PER STD PLAN N 300.6 -, w STA 21+70.97, 10.p0 LT EX. WATER VALVES (TYP.) w c I I wQ 50 45 40 35 4Tt SO J 0 403 LF 12' W DI WITH CITY v 24+00` vea 6" GV (FLxMJ) 12"4V DIP CL-52 - - CONNECT TO EX. 8" W DI CUT IN BY CITY FORCES: CONIC. BLOCK WITH PE ENCASEMENT STA 22+8713 10 00 LT OFFSET 10 00' LT FROM CIL " NOTES: on \ 1. SEE COR STD 300.00 AND 2012 WATER SYSTEM �J \ PLAN, APPENDIX J, FOR WATERMAIN CONN 70 EX. 8" W CI SPECIFICATIONS AND REQUIREMENTS. S CUT IN (B1\CITY FORCES): 2 CONTRACTOR TO VERIFY LOCATIONS OF ALL EXISTING WATERMAINS PRIOR TO INSTALLATION \ /f� 8"x8" TEE (FLr�FL) WICONC. BLOCK OF NEW WATERMAIN. vv 2$" GV (FLzMy� ' \ 3. ELEVATIONS FOR EXISTING WATERMAIN AND v 1-8" GV (F�cFL) a n➢ o 'lS SERVICES ESTIMATED VIA POTHOLING. 2S" " INC ADAPTERS (DI TO CI) `�c +•_. � 8"x12" INCRERSER (FLzFL) 4. FDC TO BE LOCATED NEAR SW CORNER OF EX.6"/8" GVs PER 1-12" FLxMJ ADAPTER BUILDING, APPROX. 40' FROM NEW FH. FIVE \ COR RECORD DWGS 1-12" SLEEVE (MJ�, ADDITIONAL FHa LOCATED WITHIN 300' OF REMOI BUILDING. FIELD VERIFY SPOOL AS NEEDED EX. HYDRANT - \ 5. CONNECTIONS TO EXISTING WATERMAINS SEE STD PLAN N0. 300.4 FIRE HYDRANT REMOVE EX. 6" W CI SHALL BE COORDINATED WITH COR STAFF. CDR FOR TESTING AND FINAL TAILS PER COR STD 310.1 FROM STA 21+62.46 STAFF TO PERFORM PIPE CONNECTIONS. TO STA 25+58.73 STA 25+58.4, 13.58 LT \ 6. EX. 6" (CI) WATERMAIN TO BE REMOVED AFTER STA 24+68.96, 14.00 LT SEE NOTE #8 \ NEW 12" (DI) WATERMAIN TESTED AND COORD. APPROVED BY COR. a WITH CITY 7. SEE SHEETS CB-2.01 THROUGH CB-2.51 FOR W(E) VT W(E) - wo 3 STREET CENTERLINE STATIONING CONTROL. v/fvvvvv \ c^ 8. ALL MECHANICAL JOINT FITTINGS AND VALVES o \ SHALL HAVE MEGALUG SERIES 1100 25+00 RESTRAINED JOINTS (OR APPROVED EQUAL) ' ' ' ' ' ' " ' 12"45° D (MJxMJ) AND CONCRETE BLOCKING PER CDR STANDARD WITH MEGALUG PLANS. 12" X 8" TEE (MJxFL) 3 ' ' W/CONIC. BLOCK 12"x2" TAPPED TEE AND GV �ssv CENTERLINE " GARDEN AVE N TEE: STA 22+73.21, 10.00 LT PER STD. 320.3 (RIGHT-OF-WAY) 8" GV'('IULXMJ) 3 STA 22+85.30, 10.00 LT (DW) - .. °.BEND �-- -- .-x..-_-. -.. -STA-22+8M,,,1"017{RR�- -.- -- -.. - - -.-.-..-..-..-..-. 8" SLEEVE (MJ) G' CONC. BLOCKS w PER STD 300.3 Ld CONN: STA 22+75.97, 3.33 LT SEE NOTE #8 ; ; - 314" WATER SERVICE ry ry TRANSFER BY CITY Q STA 22+05.62, 9.00 LT WATERMAIN PLAN - GARDEN AVE N 12"A" TEE (MJxFL) 6' GV (FLxMJ) CONIC. BLOCK e FIRE HYDRANT ASSEMBLY STA 25+55.16, 10.00 LT PER STD. 310.1 �STA24+68.96, 10.00 LT",°% HYDRANT MARKER PER STD. 310.3 STA 24+68.96, 0.33 LT'\ cj cj EX. 6" CI W !, TO BE REMOVED ! 14 a SEE CURB RETURN._... ......... ..................................................... ........ ......... ......... ...._... .._.... ........ ........ ......... SEE CURB RETURN rGARDEN AVE C/L '... .. ..... PROFILE FOR CONT. : PROFILE FOR CONT. f ---------------- __ ___ _____ ___ ....._.. ....... ... .: ..:. :.. :.................'.... 2".1RR... 2'LWJ....... .... ..:.. ELEVATION AT.... !. .._._. !. ..._... ! .._.... ...._.. .._.. _ .................. CONNECTTO _', STA 22+83 80 10.00 LT, IE = 35.58 STA 22+g5.30 10.00 LT - _-_ TOP OF CURB, TYP < EX.6"DIPW :, ____,, ---- : n IE=35.58 COORD. WICITY :, CONNECTTO STA 21+60.97,14.00 LT EX. 8" CI W ....._._..._..' .._ 1E=W.136 ._..:..._..._.......:.........Sq...:..................:...................................',......................... 12"x8"TEESLOPETOMEET .............................:................................_..,_..._._..._..i_._......._..i.................i..........._....i......_..._....i._..._.16"�W-DIP :EX. 8" DIP W : 6" FW-DIP ............................ ........... ...._ ._. ... COORO WI CBY WIPOLYPIGGING TRANSFER': 12"x8" TEE ISTA 22+75 97 I10.00 LT STA 22+87.13, 10.00 LT 12"!W DIP CLb2 ! : : : EX. CI WATER STA 25+56.73, 13.58 LT STA 21+70i97, 10.00 LT f2'SD EX. 3/4" SERVICE STA 21+73.21,10.00 LT i1E=37.09 IE=35.43 WITH POLYETHYLENE STA 24+68.96, 10.00 LT MAX. DEFLECTION 2.5° IE = 39.30: IE = 35.95 STA 22+05.02, 4.16 LT IE = 35.26 !TO BE REMOVED ! ENCASEMENT IE = 37.15 D U B I FL ' Seat Meridian 103Ave N d1a IV Seahle, WA 98103 tony@dubinerrv.Dom Environmental (206) 898-0057 0 0CD N M < N N N WATERMAIN PROFILE - GARDEN AVE N SCALE: HORIZ 1"=20' VERT 1"=5' � AS -NOTED P1301""`"'O .1.+988n9°' �Nmro o TD M DATUM �PHL F NER ONE INCH N0. REVISION BY DATE APPR � '`""''IX01°'NMY 0 N CITY OF RENTON Planning/Building/Public Works Dept. EM I- 40 U) 5 3 W a- 30 \J 0 cn W-411601 0�_ IN COMPLIANCE WITH CITY OF RENTON STANDARDS W DEVELOPMENT ENGINEERING O jchavez 08/28/2020 WATER UTILITY M.Mitchell 09/04/2020 O Q CITC RENTON ""i020.07.0]58 L J 1300 BRONSON WAY N °°'°°' _ RENTON, WA 98057 WE C> WATERMAIN PLAN AND PROFILE CB-5.� GARDEN AVE N "" 13 ° U