Loading...
HomeMy WebLinkAbout18396-CI-Hos-Submittal-15-Vault-2021-04-22To:SUBMITTAL #15 - Contech Stormfilter Vault DATE: 4/22/2021 Attention:Trenton Skoda PHONE:(425) 892-4041 Project:Forest Terrace (Pulte Homes) 2611 Union Ave NE, Renton, WA 98059 We are enclosing: Submittal Application Supplier 6'x12' Stormfilter Vault Shop Drawings Stormfilter Vault Contech (A) For approval or corrections - Return (B) For review and comment (C) Approved as corrected - Return (D) Approved - Work may proceed (E) Revise and resubmit - Work may proceed (F) Revise and resubmit - Work MAY NOT proceed ACTION REQUIRED ACTION REQD. Product 1 Contech - 6'x12' Stormfilter vault Shop Drawings *Need signed cover sheet to release for production* A Barghausen Consulting Engineers, Inc. 18215 72nd Ave S Kent, WA 98032 ITEM #DESCRIPTION 11835 NE Glenn Widing Dr. Portland, OR 97220 Ph: 800.548.4667 Fax: 503-240-9553 www.conteches.com Sequence Number Site Designation Product Description 10 Contech Stormfilter Vaults StormFilter, 6x12 Remarks: 1. Please confirm that the structure(s) shown on the attached submittal meet(s) the requirements of your project. 2. Please note heaviest section weights provided. 3. Please submit your approval or request revisions by checking the appropriate box below and returning this form and the approved submittal to CONTECH Engineered Solutions. 4. Upon receipt of “approved” submittal, the system(s) shall be released to manufacture. THE ATTACHED DRAWING(S) ARE: APPROVED AS SUBMITTED. No written comments/changes. Please cast the structure(s). APPROVED AS NOTED. Please cast the structure(s). NOT APPROVED. Do not cast the structure(s). Revise and resubmit. Certs/Inspection Required, Contract # __________________________ WSDOT Inspection required? If Yes, please complete the info below: WSDOT CONTRACT #____________ WSDOT FA# ______________ AUTHORIZED APPROVAL__________________________________________________ Please sign above Date APPROX. DATE NEEDED ________/________/________ To: Eric Anfinsen – Core & Main From: Anna Maggio Date: 4/21/2021 Project: 599910 – Forest Terrace Plat Location: Renton, WA Copies/Pages: 3 Including cover BARGHAUSEN CONSULTING ENGINEERS, Inc. Date _ By _____________________________ REJECTED SEE REMARKS NO EXCEPTIONS TAKEN SUBMIT SPECIFIED ITEM FURNISH AS CORRECTED REVISE AND RESUBMIT Corrections or comments made on the shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for conforming and correlating all quantities and dimensions selecting fabrication process and techniques or construction coordinating his work with that of all other trades, verifying compliance with the jurisdicting agencies; and performing his work in a safe and satisfactory manner. 4/22/21 Trent Skoda X PLAN VIEW FLOW KIT NOT SHOWN ELEVATION VIEW SECTION A-A CONTECH 11.25 GPM, RESTRICTOR DISK (PNK) FLOW SPREADER INLET DISSIPATOR ASSEMBLY 27", ZPG CARTRIDGE 1 1 MATERIAL LIST - PROVIDED BY CONTECH COUNT 1 14 1 15 CONTECH CONTECH CONTECH CONTECH CONTECH INSTALLED BY CONTRACTOR CONTECH FLOW KIT 11E 2" PVC SLIP PLUG 1 JOINT SEALANT DESCRIPTION 1 ZPG 100 YRS 0.35 CFS 7.43 CFSPEAK FLOWRATE RETURN PERIOD OF PEAK FLOW FILTER MEDIA TYPE SITE DESIGN DATA WATER QUALITY FLOW RATE KB #DHT6060AL 60" X 60" HATCH A A RIM ELEV. = 362.85+/- INLETINV. ELEV. = 355.48 OUTLET INV. ELEV. = 352.43 OUTSIDE BOTTOM ELEV. = 351.93 OUTSIDE TOP ELEV. 362.85 DATE: DESIGNED:DRAWN: CHECKED:APPROVED: PROJECT NUMBER: SHEET:NO.DATEREVISION DESCRIPTIONBYC:\Inventor Temp\599910-10 INV\599910-10-SF.dwgJMD DJB JMD JMD 599910 OFThe design and information shown on this drawing isprovided as a service to the project owner, engineer andcontractor by Contech Engineered Solutions LLC("Contech"). Neither this drawing, nor any part thereof,may be used, reproduced or modified in any mannerwithout the prior written consent of Contech. Failure tocomply is done at the user's own risk and Contechexpressly disclaims any liability or responsibility for suchuse.If discrepancies between the supplied information uponwhich the drawing is based and actual field conditionsare encountered as site work progresses, thesediscrepancies must be reported to Contech immediatelyfor re-evaluation of the design. Contech accepts noliability for designs based on missing, incomplete orinaccurate information supplied by others.SF0612 - 599910-010FOREST TERRACE PLATRENTON, WAfor SYSTEM: CONTECHSTORMFILTER VAULTS1 4/20/2021 SCALE: 1 972-590-2039 FAX972-590-20002201 W. Royal Lane, Suite 260, Irving, TX 75063ENGINEERED SOLUTIONS LLCwww.ContechES.com®®The Stormwater ManagementStormFilterTHIS PRODUCT MAY BE PROTECTED BY ONE OR MORE OF THE FOLLOWING U.S.PATENTS: 5,322,629; 5,524,576; 5,707,527; 5,985,157; 6,027,639; 6,649,048; RELATEDFOREIGN PATENTS, OR OTHER PATENTS PENDING.CONTECH CONTRACT DRAWING INLET OUTLET FLOW SPECIAL HATCH(1) TYP.7'-0"4'-0"5'-0"5'-0"13'-0"10'-11"10'-5"6'-0"12'-0" NONE CUZLAYOUT 2 CLASS 600 FLOW KIT STORMFILTERCARTRIDGE 2" PVC SLIP PLUG OUTLET BAY WALLWITH FLOW SPREADER OUTLET BAY FILTRATION BAY INLET PIPEØ24" HDPE(Ø32" OPG.) OUTLET PIPE Ø24" HDPE(Ø32" OPG.) PERFORMANCE SPECIFICATIONFILTER CARTRIDGES SHALL BE MEDIA-FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING.RADIALMEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. SPECIFIC FLOW RATE SHALL BE 1 GPM/SF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPM/CF OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH REPRESENTATIVE. www.ContechES.com 3. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT.4. STRUCTURE SHALL MEET AASHTO HS-20, ASSUMING EARTH COVER OF 0' - 5', AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 LOAD RATING AND BE CAST WITH THE CONTECH LOGO.5. STORMFILTER STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-857 AND AASHTO LOAD FACTOR DESIGN METHOD. INSTALLATION NOTESA. ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION-RELATED EROSION RUNOFF. STRUCTURE WEIGHTAPPROXIMATE HEAVIEST PICK = 43500 LBSOF 2 PIECESMAX FOOTPRINT = 7' x 13' SYSTEM ACTIVATION DISKLOCATED HERE. SEEACTIVATION INSTRUCTIONS 3'-6"1'-6 1/2"1'-0"3'-6 1/2"362.73362.35 362.45 362.97 LID IS SLOPED SEE ABOVE AND SHEET 31 OF 89 Slamlock1 1/2" Drain Coupling5'-0" I.D.5'-8" O.D.5'-0" I.D.6'-0" O.D.Flush DropHandleRecessedLock BoxStainless SteelCompression Springs14"Tread PlateCoversStainless SteelSlamlockTrough Frame w/Continuous Anchor FlangeStainless SteelLockbar w/HandleI-BeamCenter SupportAlum. Channel BracingSee Note "A" forPocket Requirements1/4" AluminumTread Plate Cover1 1/2 x 2 x 1/4 Angle(channel support)Detail3" ChannelExtruded Angle FrameSee Note "A" forFrame and Pocket Detail6"BeamSkirtPocket Requirements2 x 2 x 1/4Gusset1/4" Stainless SteelBeam Pocket1/4" AluminumTread Plate Cover3"ChannelExtruded Trough Frame8"Frame HeightNOTE "A" Beam Support Pockets Must be Secured with 1/2" Dia. Concrete Inserts or Anchor Bolts to Maintain Load Requirements. Failure to do so will cause Load Failure and Void Manufacturers Warranty.Beam Pocket3/8 x 4 S.S. Flat bar(to be welded tosides of pocket)2 x 2 x 1/4GussetDetail9/16" Holes(for 1/2" S.S. Bolts6 places)Extruded Aluminum Trough Framew/Continous Anchor FlangeNeopreneGasket3. Spring Assist Note: 1. Extruded Trough Frame 2. H-20 Loading 4. (316) SS Hardware & Hinges (6061-T6 Alum.)API\Alum. Prod.\Recessed Lock H20\DHT6060AL H20 w-Rec. Lock Box (12in.) 050514Z:\Submittal PDF\DHT - PDF\DHT - W-Lock Box\(Date: 05-05-14) IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4048FOREST TERRACE PLAT PULTE GROUP, INC3535 FACTORIA BLVD S.E., #600 BELLEVUE, WA 98006FOREST TERRACE PLATLUA: 18-000124C: 18-006619FOREST TERRACE PLATPR: 18-0000817/15/2020 FOREST TERRACE PLAT SCALE: 1"=20' SCALE: 1"=5' SCALE: 1"=20' R-404831 SURFACE WATER UTILITY jfarah 09/09/2020 DEVELOPMENT ENGINEERING MSippo 09/11/2020