Loading...
HomeMy WebLinkAboutzR-4181Set00 O W f— W SURVEY LEGEND: FOUND MONUMENTIN CASE ® FOUND RAIL ROAD SPIKE ® SET MAG. NAIL MEASURED CALCULATED PER ROS 20071106900003 WATER VALVE FIRE HYDRANT ® WATER METER OS SEWER MANHOLE ❑ CATCH BASIN ® AREA DRAIN o MAIL BOX P POWER VAULT JUNCTION BOX POWER POLE WITH LIGHT ❑ T TELEPHONE RISER 0 COMMUNICATION MANHOLE SIGN ROCK WALL POWER POLE GUIDE ANCHOR - P P UNDERGROUND POWER LINE OVERHEAD POWER LINE - Po Po FIBER OPTIC LINE - w w WATER LINE STORM LINE SEWER LINE WOOD FENCE DECIDUOUS TREE CONCRETE ASPHALT LEGAL DESCRIPTION: THE WEST 139 FEET OF THE EAST 493 FEET OF TRACT 332, C.E. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN DIVISION NUMBER 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 83, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. HORIZONTAL DATUM: NAD 83/91 ESTABLISHED BY HOLDING CITY OF RENTON PUBLISHED CONTROL MONUMENTS #226 AND #1839. BASIS OF BEARINGS: BASIS OF BEARING: HELD THE BEARING OF S 00'33'33" W BETWEEN THE ABOVE NOTED BASIS OF POSITION AND THE FOUND CONCRETE MONUMENT WITH BRASS PIN IN CASE AT THE CENTERLINE INTERSECTION OF JONES AVENUE AND NE 20TH STREET (ALSO KNOWN AS CITY OF RENTON CONTROL POINT #1839). DOWN 0.5 FEET. VERTICAL DATUM: NA VD 88 BENCH MARKS: CITY OF RENTON SURVEY CONTROL POINT #1839 (AS DESCRIBED FOR BASIS OF BEARING). ELEVATION = 279.17 FEET SITE BM #1: SET MAG NAIL AND WASHER IN NE 24TH STREET 4.2 FEET NORTH OF THE SOUTH EDGE OF PAVEMENT AND 9.2 FEET NW OF THE WEST END OF A 4' CHAIN LINK FENCE. ELEVATION = 256.39 FEET SITE BM #2: SET MAG NAIL AND WASHER IN NE 24TH STREET NEAR THE WEST PROPERTY LINE, 0.9 FEET NORTH OF THE SOUTH EDGE OF PAVEMENT AND 21 FEET WEST OF A UTILITY POLE. ELEVATION = 247.19 FEET UTILITY DISTRICT INFORMATION: WATER/SEWER: CITY OF RENTON (425) 430-7339 FIRE DISTRICT. RENTON REGIONAL FIRE AUTHORITY (425) 430-7000 CABLE TV. • COMCAST (800) 934-6489 GAS/ELECTRIC: PUGET SOUND ENERGY (888) 321-7779 Encompass, ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA Y8027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 A PORTION OF THE SE 114 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON CONDITIONS OF APPROVAL: 1. A DEMOLITION PERMIT SHALL BE OBTAINED AND ALL REQUIRED INSPECTIONS COMPLETED FOR THE REMOVAL OF THE EXISTING RESIDENCE PRIOR TO THE RECORDING OF THE SHORT PLAT. 2. A FINAL DETAILED LANDSCAPE PLAN SHALL BE PROVIDED AT THE TIME OF CIVIL CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. LANDSCAPING PROPOSED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE INSTALLED PRIOR TO THE RECORDING OF THE SHORT PLAT, ONSITE LANDSCAPING SHALL BE INSTALLED PRIOR TO FINAL BUILDING INSPECTION FOR THE NEW HOMES TO BE CONSTRUCTED ON THE PROPOSED LOTS. 3. A FINAL TREE RETENTION PLAN SHALL BE SUBMITTED AT THE TIME OF CIVIL CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. 0 5 10 20 SCALE 1 " = 20' DESIGNATED EMERGENCY VEHICLE TURNAROUND PER CITY OF RENTON 20' FIRE PREVENTION BUREAU STANDARD TAX PARCEL 052305-9037 TAX PARCEL 052305-9062 z 1412 N 24TH ST. 2407 MEADOW AVE. N TAX PARCEL 052305-9041 R-6 R-6 W 1512 N 24TH ST. SITE B.M. #2 f w R-6 I IQ of i I STA 12+20.00, 0.00, EL.=247.19' J a ° SITE B.M. #1 N=190132.13 - EL. = 256.39' FIRE TURN E=1302659.56 ° A RADIUS=25' - - FIRE TURN / W 45' STA 9+70.00, 0.00' - - - - - - - RADIUS=25' / / o \ N=190123.60 - - --- W, - - - / E=1302909.41 15' r::::�- - - - - - --- - -- -,o„ L .... I I I- — — — FIRE TURN \ � \ X W — _ - - - - — — — — — — .2so oo'_ �:.... — — �....... N 24TH ST. I RADIUS=45 i\ — �► ..., 12+20 12 00 .......--� __�.__ ............ �ESIDENTtA-L.--eOttEET ........ — 20 — 45' ..��— ....Ir 777�45' .. ............... ............... ............ .. .........................'................. N88"02'41"W ...................... _ _.. ' ;-.r.,- .—.._ . — — — 11 + . — .— .— f. a5'. .........................................................................................i, -.:.�o+: "- 120' ..... 00......�........... ........ - - - - _. g+.7 ........ --------- �..................... _. . ° L _............................................. ...................... ':........... .... .....................I. ,A,.... 5'R----------- --- ----- 11. O.W. - -- -- a FIRE UR------------ ---------- o `S88'02'41 E 139.04' R = d. 66.92' 72.12' A A TAX PARCEL 334450-0235 1409 N 24TH ST. R-6 0 DISCREPANCIES: LOT 2 9,536 S. F. LOT 1 10,277 S. F. TAX PARCEL 334450-0234 C.D. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN #5 L——————————— — — ---� N88°02'41' W 139.04' TAX PARCEL 334450-0250 2219 MEADOW AVE. N R-6 IF THERE ARE ANY DISCREPANCIES BETWEEN DIMENSIONS IN DRAWINGS AND EXISTING CONDITIONS WHICH WILL AFFECT THE WORK, THE CONTRACTOR SHALL BRING SUCH DISCREPANCIES TO THE ATTENTION OF THE ENGINEER FOR ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF ALL WORK AND FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND PERSONS ENGAGED UPON THIS CONTRACT. CONTRACTOR RESPONSIBILITY. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. EXISTING UTILITY NOTE: ALL LOCATIONS OF EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. S AME,S OF WASX1 CID z 38285 ISTF �SSIONAL E��l 10/1912023 I N0. I REVISION I BY ►A 72.12' o TAX PARCEL 334450-0230 1509 N 24TH ST. R-6 AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) BY: KEVIN M. REESE 1011912023 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR SURVEYED: KMR SCALE: 1.,= 20, DESIGNED: SRS DRAWN: CVP ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: CJA DATE A P P R APPROVED: CJA BUILDING SETBACK TABLE: ZL 25' FRONT YARD S COMBINED 15' NOT LESS THAN 5' SIDE YARD R 25' REAR YARD FIRE SPRINKLER NOTE: ALL HOMES REQUIRE AN APPROVED FIRE SPRINKLER SYSTEM SEPARATE PLANS AND PERMITS SHALL BE SUBMITTED TO THE RENTON REGIONAL FIRE AUTHORITY FOR REVIEW AND PERMITTING SHEET INDEX" TITLE NO. COVER SHEET AND HORIZONTAL CONTROL 1 TOPOGRAPHIC SURVEY 2 TESC, DEMOLITION, AND TREE PROTECTION PLAN 3 TESC DETAILS 4 GRADING, DRAINAGE, UTILITY PLAN & PROFILE 5 GRADING PLAN 6 CONSTRUCTION DETAILS 7 CONSTRUCTION DETAILS 8 CONSTRUCTION DETAILS 9 Know what's below. R - 418101 Call before you dig. VERHORIZONTALTICAU NAD NAV1913388 RCITY OF RENTON NWOF DATUM Planning/Building/Public Works Dept. N 28TH ST NE 28TH ST FV NE27TH CT N 27TH oLCT Q a o 0 W N 26TH ST = z U-) W � Q Qk- cn a z z o U W N 24TH ST NE 24TH ST SI TE W Z NE 23RD ST Q S2 VICINITY MAP N. T. S. PROJECT TEAM: APPLICANT. • SUKHJINDER MANGAT 10623 SE 279TH STREET KENT, WA 98030 (253) 236-6819 ENGINEER/SURVEYOR: CHAD ALLEN PE, KEVIN REESE PLS ENCOMPASS ENGINEERING & SURVEYING 165 NE JUNIPER STREET, SUITE 201 ISSAQUAH, WA 98027 (425) 392-0250 ARBORIST: ROBERT LAYTON LAYTON TREE CONSULTING, LLC P.O. BOX 572 SNOHOMISH, WA 98291 (425) 220-5711 GEOTECH: PHIL HABERMAN. PE COBALT GEOSCIENCES P.O. BOX 82243 KENMORE, WA 98028 (206) 331-1097 LANDSCAPE. JEFF VARLEY VARLEY VARLEY VARLEY 19819 30TH DRIVE SE BOTHELL, WA 96012 (425) 446-9430 ON -OFF SITE IMPERIOUS / PERVIOUS SURFACE SUMMARY. PGIS = 3,199 SF SIDEWALK = 603 SF ROOFTOP = 10,147 SF NEW/REPLACED PERVIOUS = 9,693 SF TOTAL NEW IMPERVIOUS = 8,653 SF TOTAL LIMITS OF CONSTRUCTION = 23,642 SITE DATA: SITE ADDRESS: 1415 N 24TH ST RENTON, WA 98056 GROSS AREA: 21,412 SF (0.49 AC) NET AREA: GROSS -ROW = 19,813 SF (0.45 AC) TAX PARCEL: 334450-0234 CRITICAL AREA: AQUIFER PROTECTION AREA ZONE 2 WELLHEAD PROTECTION AREA ZONE 1 MODIFIED ZONING: R-6 SCHOOL DISTRICT. RENTON #403 (425) 204-2300 ALLOWED DENSITY: 3-6 DU/NET AC PROPOSED DENSITY.• 4 DU/NET AC MIN LOT SIZE: 7,000 SF MIN LOT WIDTH: 60' MIN LOT DEPTH: 90' MAX. BUILDING COVERAGE. 409 MAX. IMPERVIOUS SURFACE: 55% MAX. HEIGHTS: 2 STORIES / 24' TREE DENSITY REQUIREMENT (2) SIGNIFICANT TREES PER 5,000 SF N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGAT SHORT PLAT ASBUIL TS COVER SHEET AND HORIZONTAL CONTROL d- O O U �2 W Q_ f— Q J 0 DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA Q DRAWING NO: 20547 SHEET:1 OF: 9 00 Q) L4 A PORTION OF THE SE 114 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON = C.O.R. SURVEY CONTROL o� POINT #226 CD (NOT VISITED z FOR THIS SURVEY) 0 5 10 20 SCALE 1 " = 20' I 2525' LOCATION OF FOR GARDEN z 7 COURT N RIGHT OF WAY IS L 3 APPROXIMATE PER KING COUNTY QUARTER SECTION MAP I I" N SDCB TAX PARCEL 052305-9037 TAX PARCEL 052305-9062 N RIM=220.14 0 �' SDCB 1412 N 24TH ST, POWER POLE 2407 MEADOW AVE. N 0 TAX PARCEL 052305-9041 0 RIM=220.94 Q 1512 N 24TH ST. IE 12" ABS (NW)=216.69 �I SDCB R-6 W/ TRANSFORMER, R-6 i, �_ IE 8" CMP (SW)=218.44 SITE B.M. #2 4 POWER DROPS Q R-6 IE 8" CMP (NE)=216.74 RIM=244.55 'A IE 8" ABS (SE)=218.45 EL.=247.19' & 1 COMM. DROP W _4 (� IE 8" ABS (N)=241.15 o� ASPHALT ASPHALT I ° a SITE B.M. #1 FOUND Pi �o IE 8" ABS (NW)=241.25 CONC. o DRIVE DRIVE / ° 1 DRIVE \ - EL.=256.39 BRASS PIN IN 13 °\ CONC. / / CASED CONC. M ° a a ° <DRIVE J CONC. MONUMENT "r / WALK _ (BASIS OF o POSITION) o W /w w W/ W w W w w w w w W W W o w- EX. 6" STE L WATERMAIN NI / -i SD SD W. W. W W W. W w w _ - - �aa CONC. SD 1 (4SD SD _ s SD z- SD SD SD / �° �- / / w W w - - W W W/ WALK \ \I - T - ate- SD SD SD �p - ( - 3 / N 24TH ST. o ® EX. 16" DUCTILE WATERMAIN �� SS SS Ss ss P s- P s P P P P P -�- - - - (RESIDENTIAL COLLECTO W W W! W o 1 / I S� S Ss s SS SS 0 Po s - - - N88'02'41 "W 744.63' FO F h0 F0. --{�. w,o SS SS SS SS - _S \ Stl SS �. _ Fop \ I FO FO FO FOI. FO FO 3 3 \ , SS SS SS _ ❑T F F \ �0 F1 FO -y- FO Fo/O FOO OO FO F0. FO \ 700- A P i C(�NC. I TRENCH O T ( HP P 0 f6 =�6 Fg-- p--E� OHP 0_ OHP OHP OHP FO F�9 �- OHP OHP OHP OHP 2 SSMH DRIU\E DRAIN SSMH CQNC. P - I _ _ _ _ a RIM=261.45 RIM=226.34 ° EfRIVE CONCH/ ASPHALT I /�88'02'41"E 139.04' �- z ° -� ° (NE)=253.45 - a - IE 6" PVC IE 8" PVC (W)=219.09 DRIVE .DRIVE � ° ° o FENCE IE 8" CONC (W)=253.25 IE 6" PVC (S)=219.09 �2001 ( o IE 8" PVC (E)=219.14 SANITARY SEWER I �L46J70 V I 12000 ° a DRIVE a 1 CORNER POWER POLE ��� X 53.200 a a 120 0.5' E. & SIDE SERVICE SHOWN I PT214 SET RBC \ T218 SRBC OIL I W/POWER & LEGEND: NOTES: PER CITY OF RENTON ° 259.1451.4' N. COMM. DROP RECORDS \ \ PT213 *rTCfMER FOUND MONUMENT IN CASE 1. HORIZONTAL DATUM: CITY OF RENTON NAD 83191. ESTABLISHED BY HOLDING CITY OF RENTON PUBLISHED CONTROL MONUMENTS #226 AND #1839. ® FOUND RAIL ROAD SPIKE 2. BASIS OF POSITION: HELD THE FOUND CONCRETE MONUMENT WITH BRASS PIN IN CASE IN THE CENTERLINE OF ® SET MAG. NAIL JONES AVENUE 15 FEET NORTH OF THE INTERSECTION OF NE 24TH STREET. DOWN 0.5 FEET (M) MEASURED 3. BASIS OF BEARING: HELD THE BEARING OF S 00"3333" W BETWEEN THE ABOVE NOTED BASIS OF POSITION AND THE FOUND CONCRETE MONUMENT WITH BRASS PIN IN CASE AT THE CENTERLINE INTERSECTION OF JONES AVENUE (C) CALCULATED PER ROS 20071106900003 AND NE 20TH STREET (ALSO KNOWN AS CITY OF RENTON CONTROL POINT #1839). DOWN 0.5 FEET. H WATER VALVE 4. THE FOLLOWING RECORDS WERE REVIEWED WHILE DETERMINING THE BOUNDARY SHOWN HEREON: FIRE HYDRANT A)LAKE WASHINGTON GARDEN OF EDEN NUMBER 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 83, RECORDS OF KING COUNTY, WASHINGTON. ® WATER METER B) RECORD OF SURVEY AS RECORDED IN VOLUME 235 OF SURVEYS, PAGE 47, RECORDS OF KING COUNTY, OS SEWER MANHOLE WASHINGTON. POWER CATCH BASIN C) RECORD OF SURVEY AS RECORDED IN VOLUME 303 OF SURVEYS, PAGE 79, RECORDS OF KING COUNTY, POLE WASHINGTON. ® AREA DRAIN CONDUIT o MAIL BOX D) CITY OF RENTON SHORT PLAT NO. LUA-13-000151-SHPL, RECORDING NO. 2013029900001, RECORDS OF KING COUNTY, WASHINGTON. ONP P POWER VAULT E) KING COUNTY ASSESSOR'S MAP FOR THE NORTHWEST QUARTER OF SECTION 5, TOWNSHIP 23N, RANGE 5E, W.M. / 1 JUNCTION BOX 5. THE FOLLOWING DECISIONS WERE MADE IN DETERMING THE BOUNDARY SHOWN HEREON: iAX PARCEL 334450-0235 Q POWER POLE WITH LIGHT 1409 N 24TH ST. R-6 A) ESTABLISHED JONES AVENUE N AND NE 24TH STREET HOLDING THE ABOVE NOTED ROS (235147). ❑ T TELEPHONE RISER B) HELD THE EAST AND WEST LINES OF THE UNDERLYING PLAT TO BE PARALLEL WITH JONES AVENUE NE AND 0 COMMUNICATION MANHOLE THE NORTH AND SOUTH LINES PARALLEL WITH NE 24TH ST. dSIGN C) HELD DEED CALLS FOR LOT DIMENSIONS. �Q ROCK WALL 6. VERTICAL DATUM: NAVD 1988 POWER POLE MASTER BENCHMARK: CITY OF RENTON SURVEY CONTROL POINT #1839 (AS DESCRIBED FOR BASIS OF BEARING). GUIDE ANCHOR ELEVATION = 279.17 FEET P P UNDERGROUND POWER LINE SITE BM #1: SET MAG NAIL AND WASHER IN NE 24TH STREET 4.2 FEET NORTH OF THE SOUTH EDGE OF PAVEMENT AND 9.2 FEET NW OF THE WEST END OF A 4' CHAIN LINK FENCE. ELEVATION = 256.39 FEET :;HP OHP OHP OVERHEAD POWER LINE SITE BM #2: SET MAG NAIL AND WASHER IN NE 24TH STREET NEAR THE WEST PROPERTY LINE, 0.9 FEET NORTH FO FO FO FIBER OPTIC LINE OF THE SOUTH EDGE OF PAVEMENT AND 21 FEET WEST OF A UTILITY POLE. ELEVATION = 247.19 FEET -W w W WATER LINE 7. THE SUBJECT PROPERTY CONTAINS 21,412 SQUARE FEET OR 0.492 ACRES. SD SD SD STORM LINE 8. PLANIMETRIC AND TOPOGRAPHIC INFORMATION AND MONUMENTS SHOWN AS FOUND ARE THE RESULT OF FIELD - VISITS IN SEPTEMBER 2020. WOOD FENCE -SSss SEWER LINE CORNER 9• TRAVERSING AND DATA COLLECTION WERE PERFORMED USING A SPECTRA AND/OR TRIMBLE 5 SECOND TOTAL 1. 5' E. & - �❑ WOOD FENCE STATION. ALL FIELD WORK WAS PERFORMED AND EQUIPMENT MAINTAINED, IN COMPLIANCE WITH WAC 332-130. 0 DECIDUOUS TREE ADDITIONAL FIELD WORK WAS PERFORMED USING SPECTRA SP-80 GNSS POSITIONING SYSTEMS, THE WASHINGTON 01. S. OF CORNER STATE REFERENCE NETWORK, AND/OR THE NATIONAL GEODETIC SURVEY'S ONLINE POSITIONING USER SERVICE a o (OPUS). ° a CONCRETE 10. THE PURPOSE OF THIS EXHIBIT IS TO SHOW THE BOUNDARY AND EXISTING CONDITIONS ON THE SUBJECT PROPERTY. ASPHALT 11. UNDERGROUND UTILITIES SHOWN HEREON ARE PER A COMBINATION OF FIELD LOCATED SURFACE OBSERVABLE FEATURES, PAINTED LOCATIONS BY APPLIED PROFESSIONAL SERVICES INC. (APS INC.), AND RECORDS OF THE APPLICABLE UTILITIES AND SHOULD BE FIELD VERIFIED PRIOR TO ANY CONSTRUCTION. RECORDS FOR TELEPHONE, POWER AND CABLE WERE NOT AVAILABLE FROM THE INDIVIDUAL PURVEYOR. ALL UTILITY LOCATIONS SHOULD BE VERIFIED PRIOR TO ANY CONSTRUCTION. 12. THE LEGAL DESCRIPTION SHOWN HEREON IS PER CHICAGO TITLE INSURANCE COMPANY TITLE REPORT GUARANTEE NO. 0188547-16, DATED AUGUST 31, 2020. LEGAL DESCRIPTION THE WEST 139 FEET OF THE EAST 493 FEET OF TRACT 332, C.E. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN DIVISION NUMBER 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 83, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.. Encompass, ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA Y8027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 M. pF WASkl����� O �0 49917 9 �� ��70NAL LAN��'�4 1011912023 I N0. \ o \ I � DESK I \ ��� \ CARPORT o \ \ CONC\ ' PWR. a (DETACHD) \ WALL / CONN. 31 �\ GATE FF EL= HOUSE #141515RIVE 255.64 0 EATH �\ \ FF EL= CARPORp BRICK ° to CONC . PAD 247.63 � ROOF PEAK I WALL, 00 \\ BENEATH DECK \ \\ FF EL= EL=269.06 a I \ 247.65 - \ \ CHIMNEY PEAK a \ \ EL=272.43 I � � O�,, DEC Q#2 \ i 14" APPLE\ TREE 16"/14" CHERRY \y \\ \\ DECK do \ I 7 9" �OGWOOD #7/ CONC. \ L23PAD \ SHED HE0 23" ELM #6 �2004 PT215 SET C S. LINE OF SHED 1. 1' N. OF LINE COS C. �� PAD 4 �ONC. - STAIRS EAVF- WOOD\ I \TAIgS \\� \� #3 _ 031" MAPLE 6.1 CONC. WALL \ TAX PARCEL 334450-0230 \ 1509 N 24TH ST. \ R-6 4.7� TAX�ARCEL 33t450-0234 C.D. HILL" N'S LAKE WASHINGTON GAREN OF ED��#5 11" G,HESTNUT \ \ S. END CHAINLINK FENCE E. OF 1 \ OF LINE 0 36" E�M \ \ #4 \ E S.E. CORNER OF SHED 1.5' W OF TAX PARCEL 334450-0250 LINE 2219 MEADOW AVE. N R-6 AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) By: KEVI N M. REESE 1011912023 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR SURVEYED: KMR SCALE: DESIGNED: SRS DRAWN: CVP ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: CJA REVISION BY DATE A P P R APPROVED: CJA 12005 52-9-35 _ P T, E. END CHAINLINK FENCE 0.6' W. OF LINE Know what's below. R- 418102 call before you dig. VERTICAL: V HORIZONTAL: NADD 198 991 RCITY OF RENTON DATUM NWOF Planning/Building/Public Works Dept. FOUND C.O.R. RENTON SURVEY CONTROL POINT #1839 MASTER BENCHMARK EL.=279.17' BRASS PIN IN CASED CONCRETE MONUMENT SOUTH 1/4 CORNER SECTION 5 (NOT VISITED FOR THIS SURVEY) z ,m Im LO I^N M W 10 Z N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGA T SHORT PLAT ASBUIL TS TOPOGRAPHIC SURVEY d- O O U �M W Q CL 0 DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA Q DRAWING NO: 20547 SHEET:2 OF: 9 00 d- O d- Q) W TESC LEGEND: SILT FENCE CLEARING LIMITS TREE PROTECTION FENCING CONSTRUCTION ENTRANCE 0 0 o ® INLET PROTECTION TREE REMOVAL APPROXIMATE CUT/FILL VOLUMES CUT. • = 35t C. Y. FILL: = 70t C. Y. (CONTRACTOR TO CONFIRM) DISTURBANCE AREA 23,642 S.F. A PORTION OF THE SE 114 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON I = CD z I 25' 25' 0 5 10 20 I z LLI SCALE 1 " = 20' J o � TAX PARCEL 052305-9037 TAX PARCEL 052305-9062 -' CATCH BASIN INSERT PER 1412 N 24TH ST. POWER POLE 2407 MEADOW AVE. N 0 I TAX PARCEL 052305-9041 COR STD PLAN 215.10 Z 1512 N 24TH ST. R-6 W/ TRANSFORMER, R-6 W I R-6 SDCB EXISTING ACCESS TO BE UTILIZED RIM=244.55 SITE B.M. #2 4 POWER DROPS AS STABILIZED CONSTRUCTION IE 8" ABS (N)=241.15 EL.=247.19' & 1 COMM. DROP ENTRANCE. SUPPLEMENT PER W ASPHALT IE 8" ABS (NW)=241.25 CONC. ° °DETAIL ON SHEET 4 IF NEEDED SITE B.M. 9' DRIVE DRIVEil" EL.=256.39' a ° ° DRIVE CONC. WALK / \� 3:/ �h W W W W W W W o w w w w w w w E. 6 STE L WATERMAIN i \ sD - W ^ w w _ W v X SD - SD SD 3'g-- SD SD' SD - �. �� c+ a. W W -pw � W N 24TH �7T:'. _ _ °° EX. 1.6 DUCTILE WATERMAIN P s ss P P Ro - - _ (RESIDENTIAL COLLECTOR) �\ - W! W - s SS SS Ss SS - - N8L)2'41"W 744,63' FOFO FO SS - - -L - - - - ;- _ Fo FO FO FO FO 0 ku FO FO FO HP - - - - - - - - ----.- F0 FO �- - 3 � f FO IO0. FO F F P O HP OHP - -OAfr OHP OHP \ OHp OHP OHP I Z Dripline r I r � I k � I I I � I I I 3" G FL Temporary I Chain Link Fence I Critical - r l Root Zane ti xpar5 - n NO One sign per 50 feet ��? TRESSPASSING t.minimum of 2 signs} PROTECTED 10 Ft. TREES Figure 1. TREE PROTECTION FENCE DETAIL. DRIPLINE METHOD A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES OR COMPACT THE EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED. B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1) OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50) INDICATING THE WORDS 'NO TRESPASSING -PROTECTED TREES', OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET (50). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES. C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE TREE'S DRIP LINE. D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE. THE APPLICANT MAY NOT INSTALL IMPERVIOUS SURFACE MATERIAL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY. E. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL AROUND ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF THE FOLLOWING AREAS: 1) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR 2) AN AREA AROUND THE TREE EQUAL TO ONE AND ONE HALF FEET (1-1/2) IN DIAMETER FOR EACH ONE INCH (1) OF TREE CALIPER. A LARGER TREE PROTECTION ZONE BASED ON TREE SIZE, SPECIES, SOIL OR OTHER CONDITIONS MAY BE REQUIRED. F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITHIN A MINIMUM OF THREE INCHES (3') OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BE APPROVED IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST OR LICENSED LANDSCAPE ARCHITECT TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES OR ROOTS, FERTILIZE AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED. H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFEGUARDS MAY BE USED IF DETERMINED TO PROVIDE EQUAL OR GREATER TREE PROTECTION WITH APPROVAL FROM THE CURRENT PLANNING PROJECT MANAGER. Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA Y8027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 IM=261.45 CONCH ASPHALT 88°02'41"E 139.04' z ° °" IE 6, PVC (NE)=253.45 DRIVE DRIVE ° _ IE 8" CONC (W)=253.25 °ii 1 1 20010 SANITARY SEWER x246.170 IzVVV 0 a DRIVE CORNER POWER POLE SIDE SERVICE SHOWN PT214 SET RBC - - - - x 253.200 ° a 12002 ^,.5' E. & W/POWER & PER CITY OF RENTON PT218 SRBC ° x 59145 .' N. COMM. DROP OILP RECORDS T213 SET RBC F CLEARING LIMITS (TYP) SILT FENCE PER COR STD PLAN 214.00 1.0 POWER POLE W/ CONDUIT oNP 2� TAX PARCEL 334450-0235 1409 N 24TH ST. R-6 WOOD FENCE CORNER 1. 5' E. & 0.5' S. OF CORNER S AME,S of 1NASX1 � CID z 38285 1STF �SSIONAL E��l o a � EX HOUSE (TO BE REMOVED) - - - - - DE K - V CONC. o CARPORT P WR. 14- GATE ° FF EL- \ CONC. PAD \ 247.63 BENEATH \ - \ DECK \ CHIMNEY PEAK \ EL=272.43 la \ 4 I \ TREE 16"/14 C ERRY \ \� a DECK TREE TO BE REMOVED (TYP) TREE PROTEION FENCE (TYP) 0 9" GWOOD #7� CONC. PAD EH II SHED 12003 S. LINE OF SHED 1. 1' N. OF LINE 1011912023 1 No. X23" ELF/ #6 S.E. CORNER OF SHED 1. 5' N. OF LINE CONW (DETAC D) CONC. FF EL= HOUSE #1415 SRIVE 255.64 o BEIS'EATH CARPORp BRICK a ROOF PEAK a WALL FF EL_ EL=269.06 a 247.65 ARAGE C C. PAD ONC. \\ �� STAIRS WOOD STAI S � #3 ( X,31" MAPLE 1 \1% I I TAX`PARCEL 33 450-0234 C.D. HILL6 N'S LAKE WASHINGTON GAR EN OF EDE I #5 11" GHESTNU I I II I / II 36" ELM 12004 #4 TAX PARCEL 334450-0250 2219 MEADOW AVE. N R-6 EROSION PROTECTION NOTE: L ALL EXPOSED SOIL AND/OR DISTURBED SURFACES TO BE COVERED WITH MULCH, STRAW, AND/OR PLASTIC SHEETING PER CONC. FIG. C.3.4.A AND/OR TABLE C.3.2.A CORSWDM. UNDER NO CIRCUMSTANCES SHALL SOIL STOCKPILES BE LEFT UNCOVERED. NALL CONSTRUCTION SEQUENCE: TAX PARCEL 334450-0230 1. PRE -CONSTRUCTION MEETING. 1509 N 24TH ST. \ R-6 2. POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR. 4.7 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). - 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH \ CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 8. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON EROSION AND SEDIMENT CONTROL ` STANDARDS. 9. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS S. END SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF CHAINLINK RENTON EROSION AND SEDIMENT CONTROL STANDARDS. FENCE 0.6' E. 10. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAY OF LINE DURING WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT. 11. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. 12. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE. / 2005 13. UPON COMPLETION OF THE PROJECT. ALL DISTURBED AREAS MUST BE STABILIZED AND BMP'S REMOVED, IF 252.9-38 APPROPRIATE. PT216 E. END CHAINLINK AROBORIST NOTE: FENCE ARBORIST TO BE ON -SITE TO SUPERVISE ALL 0. 6' W. OF CONSTRUCTION ACTIVITIES BENEATH THE LINE DRIPLINES OF RETAINED TREES. DEMOLITION NOTE: ALL EXISTING IMPERVIOUS SURFACES TO BE REMOVED PRIOR TO THE START OF CONSTRUCTION AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) By: KEVI N M. REESE 1011912023 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR SURVEYED: KMR SCALE: 1 „=20, DESIGNED: SRS DRAWN: CVP ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: CJA REVISION BY DATE A P P R APPROVED: CJA Know what's below. R - 418103 Call before you dig. VERTICHORIZONTAL: NADVD 1988 991 RCITY OF RENTON DATUM NWOF Planning/Building/Public Works Dept. N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGA T SHORT PLAT ASBUIL TS TESC, DEMOLI TOIN, AND TREE PROTECTION PLAN d�- d- O O C� �M W CL Q J 0 DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA Q DRAWING NO: 20547 SHEET:3 OF: 9 00 d- Q) A PORTION OF THE SE 114 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON DocuSign Envelope 10: 6EECF5B6-602A-4E4A-B436-A317AA638878 OocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 2'x2. 14 GAUGE WIRE, OR EourvALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC Z MIN. -- - - - - - - - - - - -- -- - r 13' MAX. I I 72" MKV� POST S PACING MAY HE INCREASED 4-.4' MIN. TRENCH 70 8' IF WIRE SACKING IS USED I A ,LJI BACKF ILL TRENCH WITH NATIVE SOIL OR W4' TO I.1f2' WASHED GRAVEL 2"x4" WOOD POSTS. STEEL FENCE POSTS, OR ECIUIVALENT (TVP. ) MOTES: 1. CONDrTIDNS OF USE 1.1, SILT FENCE MAY BE USED ODWNSLOPE OF ALL DISTURBED AREAS 12 SILT FENCE rS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW_ ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AHD INSTALLATION SPECInCATKNS 2.1. THE GEOTEX TILE USED MUST MEET THE STANDARD LISTED BELLOW, A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE ADS (ASTM 047511 30-1110 SIEVE WE {6.Sp-p. l&x ) FOR SIL7 FILM 5l}100 SIEVE SIZE (0.3U-416m ) FOROTHERFABRICS WATER PERM ITUVITY(ASTM D4491) 0.I12 SEC'MINIMUM GRAD TENSILE STRENGTH IASTM D46321 1$D LBS. M IN. FOR EXTRA STRENGTH FAE3RIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4932) 30%MAIL (WOVEN) ULTRAVIOLET RESISTANCE(ASTM D43551 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BAC%ING TO INCREASE THE STRENGTH OFTHE FENCE WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMAME WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL M07 BE STEEPER THAN 2H:1 V 2.4. IF ATYPICAL SILT FENCE IS USEO, THE STANDARD 4'X4' TRENCH MAY BE RLAUCED AS LONG AS THE BOTTOM S INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 25. FILTER FABRIC FENCES SHAL L BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND_ 3.3. IT IS IMPORTANT 7O CHECK T HE UPHILL S IDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNFLZA7K7N OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRIPPED SEDIMENT 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT LS 6 INCHES HliaM. 3.5. IF THE FILTER FABRIC (GEOTEXTILf I WAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLE55 OTHFNLVISE NOTEb, DRAWING Z NOT Tn SCALI: CNT54 STD. PLAN - 214.00 1a PUBLIC WORKS SILT FENCE PROM-9/2$Izaxa 1 - DEPARTM ENT GAZ N4Wo„w: wo-,. a,i„�,,;,,,,q DATE Encompass, ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 :45 V �ORpPP R = 26 MIN. � INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STAN CARDS 4'-B" QUARRY SPALLS GEOTEXTILE 12' MIN. THICKNESS ADP MIN CONSTRUCTION ENTRANCE NOTES: 1 DRIVEWAYS SMALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2, IT IS RECOMMENDED THAT THE EN7RA.NCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15' MIN. PROVIDE FULL WIDTH OF INGRESSIEGRESS AREA NOTES: 1- CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL, BE STAB ILLZEU WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,GG6 FEET OF THE SITE 12: FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVI SION ENTRANCE STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHMIDTH TO PROVIDE VEHICLE ACCEMPARKING, BASED ON LOT S2E'CONFIGURATION. 7. DESIGN AND INSTALLATION SPECIFICATION$ 2.1. A SEPARATION GEOTEXTILE SHALL HE PLACED UNDER THE SPALLS TO PREVENT FLNE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS - GRAB TENSILE STRENGTH (ASTM 04632) 2M LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30%MAX. IWOVENI CBR PUNCTURE STRENGTH (ASTM D6241) 45)5 LSS. MIN. ADS (ASTM D4751) 20.O (U.S_ STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3. HOG FUEL (WOOD BASEO MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE LISP OF QUARRY SPALLS IF THE HOG FUEL i NOT PREVENTING SEDIMENT FROM BEING TRACK ❑ ❑NT❑ PAVEMENT OR IF THE H05 FUEL IS BEING CARRIED ONTO PAVEMENT 2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5- WHENEVER POSSIBLE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIFRM. COMPACTED SUBGRAUE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE L MAIWENANCESTANDAR08 3.1. QUARRY SPALLS SHALL HE ADDED IF THE PAD 15 NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING $EDWENY FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL 13C USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. DR THE INSTALLATION OF A WHEEL WASH IF WASHING LS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 3.3, ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEOIAT ELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DDWN THE STREET, EXCEPT WHEN SWEEPING IS rNEF FECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WA511 THE STREETS. A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANFROT DISCHARGE TO SYSTEMS TRIBUTARYTO SURFACE WATERS. 34. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAC) AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5, IF VEHICLES ARE ENTERING OR EXFr1NG THE SITES AT POINTS OTHER THAN THE CONSTRUCTION £NTRANCE(S), FENCNG SHALL BE INSTALLED TO CONTROL TRAFFIC. LINLE55 OTHERW rSY NCIV3. DRAWING 35 NOT TO SCALE (NT54 STD. PLAN - 215.10 PUBLIC WORKS PPROVED- +1� DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 rww.wow..nMn�uow RATE pp�-MES WASH �I ®d 38, IM 10/1912023 1 N 0. :4 5 AI B' MAX_ DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS Y ' BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN I RETRIEVAL SYSTEM CTYR) 1. Q II OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: L PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 501) FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CO IV o TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE IBIGD4 FOR THE STO R1.IWATER STRUCTURE IT WILL SERVICE_ 5, THE BIGO SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS), 5. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGO WITHOUT SPILLING THE COLLECTED MATERIAL 7. PE RFDRM MAINTENANCE IN ACCORDANCE WJTHSTANDARP SPECIFICATION I3-01105} S. ANY SEDIMENT IN T34E CATCH BASIN INSERT SHALL BE REM OVER WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE THE FILTER ME01A FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OT[ NWIA N41En, DRAWING I$ NOT TQ SCALE (NT51 STD. PLAN - 216.30 PUBLIC WORKS APPR Ea- DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 �onawo.e. annmaoim PATE AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) BY: KEVI N M. REESE 10/19/2023 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR R-418104 : 4 5 AI DocuSign Envelope ID: 6EECF5B6.602A4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL [ESC] STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOT ES THAT SMALL BE I NCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. T ADDITIONAL NOTES ARE NEECED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TD AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR 2_ THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASH INGTON STATE DEPARTMENT OF ECOLOGY {ECOLOGY) CONSTRUC11ON1 STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT_ THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT- Z. THE ESC PLAN SET SHALL INCL UDE AN £SC CONSTRUCTION SEQUENCE DIETA31UN5 THE ORDERED] STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS. AND AREAS OF VEGETATION FR£SE.RVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(SI SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN T HE F IELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DEsink MANUAL IRENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE c0A9TRUCTI0N PERIOD. NO DISTURB NCF BEYOND THE CLEARING LIMrrS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTALNED BY THE APPUCANTIESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RI GMT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SE DIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFFSrrE OR IN oFSEGHATEI3 CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND- pia TO STORM 13RAINS OR OPEN DITCHES- OWSITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS 7. ALL REQUIRED ESC HARPS SHALL HE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING ANDIOR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING ANWOR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALLESC 8MPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE ER08IDN DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILTY OF THE APPLICANT S. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9 THE ESC 8MPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TQ ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TOADDRESS ANY NEW CONOITrONS THAT MAY BE CREATED eY THE ACTIVITIES AND TO PROVIOEADOI TIONAL ESC BMPS. OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE keEOED, TO PROTECT ADJACENT PROPERTIES AND WATER OUALr Y OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY, FT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DE51GN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES, 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12 ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT HE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 3OTH) OR SEVEN DAYS DURING THE DAY SEASON (MY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERENG, ETC.) IN CONFORMANCE WITH APPENDIX O OF THE RENTON SWDM. 12. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTI014 BYTES BETWEEN OCTOBER 1 ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY_ 14 ANY AREA NEEDING ADDTONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITH IN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREOUENTLY AS REQUIRED BY THE CITY 16 BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CRY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS TIOW NSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTEO ANO REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED X1 OF THE CAPACTIY OF THE CATCH BADN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH 5EDIMENT- ADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. rF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE BOUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY_ 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILIMES OR ON -SITE BMPS (AMENDED SOILS. BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUC7I0N. 20 PRICK TO THE BEGINNING OF THE WET SEASON IGCTOBER 1 ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED DR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVI NG THE PROJECT SITE ALL ESC BMPS SMALL LSE REMOVED, ANO STORMWATER CONVEYANCE SYSTHIAS, FAGILFTIES, AND QN-5LTE 8MPS SHALL BE RESTDRIED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT 517E SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM. DISTURBED AREAS SHALL BE SODBED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST, 22 ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS-OF•WAY SHALL BE CONSTRUCTED IN ACCORDANCE WrTH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGWs-DF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL euILWNO CODE UNLESS dTREpwISY NOTED, DRAWING IS NOT TO SCALE CN!!5l STD. PLAN - 268.00 STANDARD PLAN NOTES PUBLIC WORKS EROSION ANDURSEDIMENT CONTROL D- DEPARTMENT GIAZ 9/28/2018 1 _ romwwo Aainnvuim RATE Know what's below. Call before you dig. :4 5 Ah N COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: SCALE: VERTICDATE: KMR 1 AA= 20 A HORIZONTAL: N DV1983/111991 1011912023 DESIGNED: SRS % CITY OF '� RENTON MANGO T SHORT PLAT ASBUIL TS FIELDBOOK: /A DRAWN: PAGE: N CVP DRAWING NO: ONE INCH DATUM TESC DETAILS 20547 CHECKED: CJA AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE A P P R APPROVED: CJA SCALE ACCORDINGLY SHEET: 4 OF: 9 O �J (- Jl N O O O O N J O N 00 I 00 N N ZE 2 w 260 250 240 230 220 A PORTION OF THE SE 1/4 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON \ \ LOCATION OF FOR GARDEN Z COURT N RIGHT OF WAY IS APPROXIMATE PER KING COUNTY d QUARTER SECTION MAP DESIGNATED EMERGENCY VEHICLE L w CONNECT TO EXISTING CATCH TURNAROUND PER CITY OF RENTON I 2 BASIN WITH INSIDE DROP FIRE PREVENTION BUREAU STANDARD STRUCTURE. CORE DRILL AND TAX PARCEL 052305-9037 TAX PARCEL 052305-9062 SDCB PROVIDE WATER TIGHT SEAL 1412 N 24TH ST. POWER POLE 2407 MEADOW AVE. N F I TAX PARCEL 052305-9041 69 I I RIM=220.94 SDCB R-6 W/ TRANSFORMER, R-6 Q 1512 NR 24TH ST. 4 / 3 IE 8" CMP (SW)=218.44 RIM=-244.3 4 POWER DROPS Q IE 8" ABS (SE)=218.45 & 1 COMM. DROP HALF STREET GRIND w ASPHALT IE 8" ABS (N)-241.15 AND OVERLAY � � so ASPHALT IC R" Aqc �LiWI-? 1 ?5 CONC. ° ° DRIVE DRIVE NEW i IE (SE)=z4.BB' 241. "D °.1 DRIVE / - FIRE TURN CONC. \ / RADIUS=25' ° DRIVE CONC. FIRE TURN 45 ° ® WALK w w � / COMM RADIUS=25' / \� � 1 �/ �/�\ '� w w w w w w w w w w w o ff 6" STE L WATERMAIN N sD SD- sD WSD 1_ so 4 sD _ S SD S� CABINS I w A W w. w w w r- w FIRE TURN W W __Z7 _ - - - - N 24TH ST. N A - I SD SD 3- BD Sp. SD - - - - - ' / _ \ W W �- _ RADIUS=45 EX. 1.6 DUCTI WATERMAIN Z ss ss ss ss s s ��i s P S 0 P. reE1 kA C�tLEE fir - 45' W_ W , s - 45 ss ss sS " _ .. ss - I 3 is* SS SS ' ss ' 20 5 P B S l P f... /.. i0+ _ T -� / 9+70 F .. .. .......... H .. OHP _...Or.-..... QHP.....?.9-IP....-. OHP ...... ..OHP.......OHp . SSMH CQNC. P .. - ... _ RIM=261.45 RIM=226.34 ° DRIVE � CB #� CONCH ASPHAL � ��g a W _ 90' °y 5:1 IE 6" PVC (NE)=253.45 IE 8" PVC (W)=219.09 STA:11+75.03, 12.22 T DRIVE DRIVE 1 4° /11.5'R.O. C+ < �j� TAPER IE 8" CONIC (W)=253.25 1 _ 5:1 TAPER a < FIRE TURN - IE 6" PVC (S)=219.09 `" TYPE 1 CB i ° ��� � e IE 8" PVC (E)=219.14 RIM=�4&99 246.12 �` a ..d ° d POWER POLE ' Q . IE=22 %*" (E)244.02, 8"ADS _ L W/POWER g� RADIUS=45' IE=24&22 8" (NW) 243.9, 8" DI IE = 244.12, 6" PVC (S) POWER POLE W/ CONDUIT ore TAX PARCEL 334450-0235 1409 N 24TH ST. R-6 0 I► �' � N 3 -- Q ^� co - -;° o ea 'o -' EX GRACE AT W ROAD CENTERLINE ' _ Cr W cnC4Cb _---- N CURB FLOWLINE 00 -r : N °° W v + P EX WA R m o ^ APPROX LOCA ON _ END OF PROPOSED FRONTAGE IMPROVEMENTS u n N 120LF8 PIS -_-- ___-- W v~i W L W - WATER SERW O �J: li i .1.1 % _ - -� 07ER SERV10E___-- - ' - EX SANITARY SEWER C - ° AP ROX LOCATION 25LF8"DI0 -._- 1.53% EX8" _--- 5 N zU �W 5 0) M CA W N N XW W II Vi W CNq p N co to N 00 N O 0) N d N cv N d N N N N cV N cv N N N N N LU w � LQ CD w � LQ w � LQ 12+00 11 +00 10+00 N 24TH ST PROFILE SCALE: HORIZ. 1 "= 20' VERT. 1 "-- 5' N M E S WAs�f� ncompass ENGINEERING & SURVEYING z Western Washington Division ®d 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 �� 38285 I STD Eastern Washington Division �SSIONAL�� 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 10/19/2023 rNO. L ►( E 1. SSCO 25 RIM `L 24P.51 $SCO IE=24 � RIA( 25 F I I 1 \ I 1 I I LOT 2 I 9,536 SF I I v LOT 2 1 9, 536 I O1 S. F. S. LINE OF SHED 1 J' N. OF LINE 260 250 240 230 220 CB TYPE 1 RIM=246.0 IE=244.0 (�)j \ ti &8 = F 0 Zb, I F-------------- LOT 1 I� 10,277SF 1 \\ I LOT 1 1 As 10, 277 �I I , S. F. I I I TAX`PARCEL 33�F450-0234 / C.D. HILL N'S LAKE WASHINGTON GAR EN OF ED' #5 19 CB TYPE 1 G 1 RIM=251.0± IE=249.0 0 I ' aD I I ✓✓✓ N I IN jN 0 2 LNj I 3 1' ELM jI #6 - i k \ k L_--- - - - - - - TAX PARCEL 334450-0250 2219 MEADOW AVE. N R-6 AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) By: KEVI N M. REESE 10/19/2023 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR SURVEYED: KMR SCALE: 1 "-20' DESIGNED: SRS DRAWN: CVP ONE INCH CHECKED: CJA AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY REVISION BY DATE A P P R APPROVED: CJA COMM. DROP 6.25% _CB #2 STA:10+55.03, 12.22 LT TYPE 1 CB RIM r 256.14 IE=Pii4 994 9 (W)253.74, 8"ADS \ TAX PARCEL 334450-0230 \ 1509 N 24TH ST. R-6 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 11.5' DEDICATION *PER COR STD 201 418101 418101 Know what's below. 418105 call before you dig. - , C TY OF RENTON Planning/Building/Public Works Dept. EX. 15' R.O.N 13' PAVING EX. kL CURB PER I SAWCUT & MATCH EX. CIL 0 5 10 20 SCALE 1 " = 20' N 24TH ST. SECTION (RESIDENTIAL COLLECTOR) NTS KEYNOTES: OA EXISTING UTILITY TO BE UNDERGROUNDED. COORDINATE K17H U71LITY PROVIDER OEXISTING MAILBOX TO BE RELOCATED AS SHOWN OC EXISTING 3/4" WATER ME7ER AND SERVICE LINE TO BE CUT AND CAPPED AT THE MAIN (BY CITY FORCES UNDER SEPARATE PERMIT) OD EXISTING SEWER SERVICE TO BE CUT AND CAPPED AT 7HE MAIN LINE OE PROPOSED 1" WATER METER SERVICE PER COR STD PLAN 320.1 (SERVICE AND METER TO BE INSTALLED BY CITY FORCES UNDER SEPARATE PERMIT) OSANITARY SEWER STUB WITH SSCO PER COR S7D PLAN 403.1 AND 406.1 OG 50' BASIC DISPERSION TRENCH M7H NOTCH BOARD AND 25' VEGETATED FLOW PATH, TOP OF THE TRENCH TO BE LEVEL AND ALIGN WI7H CONTOURS (TO BE CONSTRUCTED UNDER SINGLE FAMILY BUILDING PERMIT) OH PAVEMENT RESTORA71ON PER COR STD PLAN 110, 110.1, 110.2 (TYP) OCONNECT TO EXISTING SEWER MAIN USING INSERTA TEE CONNEC7ON O25 LF 8" DI O 0.88% OK PROPOSED 15' RESIDENTIAL DRIVEWAY PER COR STD PLAN 104.3 OL PROPOSED ASPHALT ADA RAMP K17H PEDESTRIAN CURB PER COR STD PLAN 101 (TYP) OM PROPOSED VERTICAL CONCRETE CURB & GUTTER PER CDR STD PLAN 101 ON SAWCUT LINE OO GRADE TO DRAIN OP 120 LF 8" PVC 0 9.77% NOTES: 1. ALL NEW HOMES SHALL BE EQUIPPED WITH A RESIDENTIAL FIRE SPRINKLER SYSTEM APPROVED BY THE RENTON REGIONAL FIRE AUTHORITY UNDER A SEPARATE PERMIT. A MINIMUM 1" WATER METER IS REQUIRED FOR HOMES EQUIPPED WITH A RESIDENTIAL FIRE SPRINKLER SYSTEM. A DOUBLE CHECK VALVE ASSEMBLY IS REQUIRED DOWNSTREAM OF THE CITY WATER METER. 2. A PRESSURE REDUCING VALVE SHALL BE INSTALLED DOWNSTREAM OF THE CITY WATER METER ON PRIVATE PROPERTY SERVICING ALL NEW HOMES IF WATER CONNECTION STATIC WATER PRESSURE EXCEEDS 80 PSI, EX. 15' R.O.W. X. 13' PAVING N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGAT SHORT PLAT ASBUILTS GRADING, DRAINAGE, UTILITY PLAN & PROFILE 0 N U N J �J Q_ Q_ 0 DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA DRAWING NO: 20541 SHEET: S OF: n 0 U 0 0 0 Q J 0 CN W CL Q J CL Q QD Q z J DocuSign Envelope 10:38183403-7EOAA76C-AD83-4329FFEGCIOB DocuSign Envelope 10:38183403-7EOAA76C-AD83-4329FFEOCIOB SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF UENEPAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET- ALL YHE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT THE APPLICANT OR OWNER. HEREBY REFERRED 70 AS APPLICANT, MAY SYRI KE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL 140TE5 ARE NEEDED FOR SPECIFIC ASPECTS THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HERESY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLIGANr13 CONTRACTOR 2- THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY- STATE AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3 ALL STORM ORAINAGE IMPROVEMENTS SHALL BE DESIONED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDMI. RENTON MUNICIPAL CODE (RkIC). AND THE STANDARD SPECIFICATIONS FOR ROAD. BRiOGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AJERICJW PUBLIC WORKS ASSOCIATION (APWA)_ IT SHALL.BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSK7N OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS- ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TC: THE CITY. A. APPROVAL OF THE ROAD, GRADING. PARKING. BUILDING. AND ORAWAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E-G. WATER, SEWER. GAS. ELECTRICAL ETC.). PLANS FOR STRUCTURES SUCH AS 0ROCE5. VAULTS. AND RETAINING WALLS REQUIRE A SEPARATE RENEW AND APPROVAL BY THE CrTY PRIOR TO CONSTRUCTION, THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COOIDWATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5 A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION RS IN PROGRESS- &. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABIJSHEO BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AMC, NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS•SUILT DRAWINGS ALL UNOOCUMFJNTED UTILITIES DISCOVERED AND ANY CHANGES TO THEAPPROVED PLANS. THE APPLICANT SHALL IMMEDNTELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS- 7. VERTICAL DATUM SHALL BE NAVD S8 AND HORIZONTAL DATUM SHALL BE MAD 433 (WA STATE PUKE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY - REFERENCE BENCHMARK. DATUM. AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8 ALL UTILITY TRENCH BACKFILL AND ROADWAY SLEGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2•03.3f14P • COMPACTION AND MOISTURE CONTROL TESTS OF THE "DOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED -TO MORE THAN 9296 OF MAXIMUM DRY DENSITY- 9 OPEN CUTTING OF ExISTTNG ROADWAYS FOR STORM DRAINAGE WORK 15 NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PL AhS ANY OPEN CUT SHALL. B£ RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS 10- ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PUNS OR WHERE DIRECTED BY THE CITY. THE EXISTING MANHOLES. CATCH BASINS OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL RE WSTALLEO AND IN OPERATION PRIOR TO. OR IN CONJtmTION WITH, ANY CANSTRUMoN ACTIVITY UNLESS 0fHDWSE APPROVED BY THE CFTY 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED REDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIrROING RASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLIW 220-DC, Z20,79. AND 2Y0-20 I a. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2. OR 5INSIDE AND OUTSIDE. 14, ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FrrTED WITH DUCTILE IRON. BOLT -LOCKING UOS PER THE CITY STANDARD PLAN 204-10- 204.20, 204M. 204.441, AND 204-50. STRUCTURES SHALL HAVE • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WEfHIN THE ROADWAY- BUT OUTSIDE OF THE CURSIGUTTER LINE - ROUND. SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TOTHE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-CF-WAY AND EASEMENTS TO THE CrrY SHALL NOT DISPLAY THE CITY LOGO - IS. ElUILDINOS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDAANCE WITH TABLE 4 1 EASEMENT WIDTHS AND BUILOMHI SETBACKS UN ES OF THE RENTON SWD` I le. LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOI.EICA.TCH BASIN RIMS SHALL SE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN IT ALL DRIVEWAY CULVERTS LOCATED WITHIN CFY RIGHT­QF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A M IµIMUM 3:1 SLOPE FROM THE EDGE OF THE DR IVEWAY TO THE BOTTOM OF THE DITCH UNLESS OTH ERW i5E NOTED. DRAWING M NOT TO SCALE RNT51 STD. PLAN - 267.00 PUBLIC WORKS SURFACE WATER STANDARD PLAN agIo%dny: DEPARTMENT NOTES (1 OF 2) artin Pastucha8/13/2020 DATE _-I1EE"'1E X S/B•D DUMMY JOINT 2' - aD- 3/0' PREMOLDED JOINT FILLER (TY2) rFACE DP ff FRANE A QRA71? CURB l�I-EIE>t"IC��E'- II-�I1111T�IFI L�lr�lrlr! i �� I/2" RINAWDr[ERIUDRE ROADWAY I GLOM TOP OF W 3• mI REc1rJ� ROADWAY • p• C b- ♦ a 1- P ••••• a AWUSTNIMSECTION-NGTINCLUDED : n' IN WRB AI'lq GU1"IT3N 81DDEA1 CATCH aSSIN - NUT DICE. WED v - BN CUTNB AND QITI-IER al D (TEN •b SE-.T16T4 C) GENERAL NOTES: EM NOTE 2 CESIMT CURB AND GUTTER CONCRETE 1. The intent of this design is to W tt b the removal �• .of a Catch basin v4th minimal disturbance Of the MM. - 2. The expansion Joints of the adjacent aldewelk shall be -adjusted to be In r + Ir Ilne wltlT 81B5e curb expanslon Joints. I ISOME41C MLW CEMENT CONCRETE: CURB - 101•I PUBUC WORKS RD F: DEPARTMENTINSTALLATION AT �j CATCH BASINS Encompass, ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 1 8.48 A PORTION OF THE SE 1/4 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING M A OSTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET- ALL YHE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT THE APPLICANT OR OWNER, HEREBY REFERRED 70 AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTE5 ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER TI IF SURFACE WATER STANDARD PLAN NOTES. Ia. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES- WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE 01 FOOT AND SHALL ME£F THE FOLLOWING SPECIFICATIONS' • 4,E;NCHR0CK140-Tt1%PAS5ING; 2 -4 RICH ROCK I S0 -4(]% PASSING: ANO • LESS THAN 2INCH ROCK 110. 20% PASSING_ 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE. UNLESS APPROVED BY THE CRY FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BM PS 20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED, A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED 'STORM'OR'DRAIN' SHALL HE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227-Oo- 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY ASURVEYOR UCENSEO IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION 22. ALL NEWLY -IN STALLED AMC, NEWLY•REHABI LITATED (PUBLIC AND PRIVATE; STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE OCTV ACCORDING TO THE CITY STANDARD PLAN 266.010. CCTV INSPECTION S AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS. GUTTERS ANDIOR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO ExISTWG MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-004 311) OF THE WSDDT STANDARD SFECIFICA770N�; AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAW STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED 24 FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED- ETC.( OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITFI STANDARD PLAN 264-t)0 25 ISSUANCE OF THE BUILDING OR CONSTRUCTION PERLIFFS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND70R LIABILFTY CCNWCTED WITH STORMW ATER DISPOSAL THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION 26. ADEQUATE SAFEGUARDS- SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RI5HT43r•WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SRALL REOUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CrFY ALL SECTIONS OF THE WSODT STANOARO SPECIFICATIONS 1-107EMPORARY TRAFFIC CONTROL SHALL APPLY. 27 PROJECTS LOCATED WITHIN THE CJTY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPEC IAL REQUIREMENT p6 OF THE RENTON SWOM AND AQUIFER PROTECTION REGULATIONS IRMC 4-M501. 28. PLACEMENT OF SURFACE APPURTENANCES ICATCH BASINIMANHOLE LI(1S, CLEANOUTS, 1NLETS, ETC-) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, S[DEWAU(S, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE ANY SURFACE APPURYENAHW PLACED 1N A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON-EQP OR NON-9KIQ LID PER ADA REGWREIAMTS, M. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS, PRIVATE SYSTEMS SHALL BE MAINTAINED SY THE APPLCANT, 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4Y.1 A2 OF THE RENTON SWOM. 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER FLOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTER CONTINUOUSLY FOR AT LEAST 10 MINUTES COMPLIANCE WITH THIS MINIMUM RATE SHALL, BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT COMPL IANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN W HICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE- THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST LS NOT CONCLUSNE- THEN ANOTHER TEST PER ASTM C1 161 SHALL BE CONDUCTED. FOR LARGE AREAS (E. G.. PARKING AREAS;, TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST- PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781- UNLE55 OTHERWISE NOTED, DRAWING 15 NOT TO SCALE I N I STD. PLAN - Z67.10 PUBLIC WORKS SURFACE WATER STANDARD PLAN[ FRI §RFd by: DEPARTMENT NOTES (2 OF 2y Aar -tin PastuGhJ/13/2020 •1rk1F �..�n'iia DATE 8• RAISES] EDGE DETAIL 1 BIZMWAkX LEVEL fat• EXTENE, WDEWALK TRANSVERSE 1••e' T-15, 218'BHI PRDWLDEG JOINT FID-Rt 1rJ"WHIR JOINTS TO INCLUOE RAISED EDGE 4"0UPA:GT::TO DALVJHERLAPPL]n„gaN.aFOR CURB DETNl3SEE BTU PLAIN 1DI 46,ING ROADWAY oN i'.i-R-HEnSE'E NAI5FA_-BIOEWALIC UNiTAX-TII183H CRIMEDSURFACMTOPCOUR811 p�OTC;LLCkITMIN. ONPM1CF FO 95LK 1JODIFICD PRO C i6R I WITH RAISED EDGE IUNLEW REUDLFIDIEWT iv ED 9Y Irr II R(TYP. ENGnNEERI TYPICAL UNDER ALL CURD, GuTTIFIR AL 20% NDER 1 q FOR GURA DETAILS CUM aO I TEER OIL g71HICRC�e DR N 0p 1•'•GL MATCH E?79T81G R M GW CRIIBHEG ROCK '.vi .' •_ .r SEE STO PUN 161 MATE, WHk'SMGR 18 GREATER SHEryp FOR pLFT1 ALL CURSEGLITIBR} 1 FINISHED tlRAEE 7•(1N18RpW FOP DF CDNDitE-[E Sa�i11FACE ADJACENT TO CURB t••r 1,_a, MIN. RDu DwG 1fJ• pNy R [rrP.J ems I "CURSOETAILS tsy V. $a1 TD PLAN eRIDDEPR PEOES�iLAAN� •• • ,I-• •�pVi3'I" FOR CURD DETAILS ADJACENT TO CURB lid BIER -ILE WDEH'ACR BEE STO PLAN 101 (STEEP FILL SLOPES) OOWRACTHANS ALL OR DARMR. IM' Ilk)R. (TYP.) RuSH t 1 ti I - SIDEWAIX 7_ax VERTICAL WALL .. 9 .. .. I�• ": a' ME DETAIL • . r 11M PREAID[DED�-- •• JOINT FILLER ADJACENT TO CURB AND RAILING OR WALL Ppeiii LDED JOINT FILLER FOR BIDE TREATMENT SIDEWALK WJF}XR STRIP SIDEWALK ADJACENT TO WALL DETAIL MDVWAt1( (BEE NOTE 1I CFYP9ECnDkB 77 .) f t : 13k 'I FOR OURS AN imB fSXf�eM. SFE STD PUN 101 + OR R MATCH FINEXI1 TI ORI.UTCH EaiSTIDIG �. TRODE, RUwELED PER(PEAIMETEA PINMHED LYUG£ I" IINI tLONI TOP OF COIiGYiETE -r BVRTiAOE FOIL IND-FLUGH IFPAVi:O jfl••o- S" il• 7 • •. "� CEMENT CDNCREFE cUm ADJACENTTCI3UFFERS7IUP [Y� �~ ~ �'• LCURB Amu inurrER s1-rowk} '. .. FOR CURD DETAILS SEE STO PLAN 1W NOTESr - z 11ITO 1H' 1- Flier feel of the Rldevnik Wft OTTII •: �� _ - ba the whIraum pedasRlan �i' � ,ICONTRACT"L JOINT ► •' � , 80c@ bia mute IaVN trod of ventral c • ► . .''.+ Tp •' and h IL=Led ab5LFUCUone. GraBnge, -' Awesa Co -am. JlnciloD FLDLL•U$PTH EXPANSION JOINT IN BOTH • I• CAWBVai*s, Pull BomIs and o&r MM AND SWEWALK({FE STa MM ]CIA 9ppumusst b INA iM binour LhD s}dnvralk `�� •% dra' 4 - CONTRACTION JOINT mU6I dM INsh WRIT dUfIaOD, anti raatch ' grade or Lhe eldawalk. •- JOINT AND FINISH DETAIL 2. Marw lthle Cement Conuote Curb and Sidewalk a not perminM In new For other referenced NOTES Bea • • ' : I ; `q� constwdLon When reptacamoln work STO PLAN 104.2, heresslmtesI Mondiffirc Cement Concrete Curl, build per WfDDT MOT FIT} -ER Slndard Plan Fa6Iu-p3, Paved surfaces must comply with 5TO PLAN 1OZI as apptleabla. E • FULL-OEPTN S. Cwlrrete l0 6c 4,11lDO PSI. EXPANSION JOINT )&�D BLI 7WORKS CEMEINT COMCFtETE =. P - 102 1:1J TMEN7 SIDEWALK • I JIH2(r II;17. fr r ��MES of WASH f � 01) t'� 38285 I STL��� �SSIONAL�� 1011912023 I N0. 8:48 FACE OF CURS _Biz 5112' S" 1i2•ly. v 1'R 124 4 TOP OF 1lZ'R. ROADWAY 1 CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 1 rd •-8 •-- FLUSH WITH GUTTER PAN AT SIDEWAL1i RAMP ENTRANCE M2 124 rLTP OF 112• R• ROADWAY I To I V-0. DEPRESSED CURB SECTION AT SIDEWALK RAMPS aw &' CEMENTCONCRETE 112' R. 1• R SIDEWALK RAMP VARIES OR LANDING FROM 6'TOO 1 B' } 31W PREMOLDED JOINTFILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB a 7 ri y SEE DEPRESSED CURB DETAIL THIS SHEET 124 TOP OF I 1 1• In, R ROADWAY T Y - i 4 1' • B• DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STO PLAN 104-2 FACE OF CURB FACE OF ADJACENT CURB • '.e GUTTER SURFACE 'i0 •r PFIEMOLDEO JOINTFILLER E FULL -DEPTH EXPANSION JOINT 8 1 ri' 5 1I2' 1' V R, N I • � TOP OF ROADWAY 1 T 0 1I4- CEMENT CONCRETE TRAFFIG CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAY& AND ALLEYS GENERAL NOTES: I. Sae slanderd plans 102 and 101.1 for L•1Nb wanslOn and Donvacton Mint spacing, 1. Expamlon joint shad be full depth, 3/8'(In-) "molded Julm Viv, 3, For Depressed ManolPhk Ddvirway Curb 6 Guller S Ian, see Standard PWn 104.2 M. PLAN! - 101 PUBLIC WORKS llliI'AR'I'1v4ENT CEMENT CONCRETE CURBS 11J111, I'l 6 CEMIDIT CONCRETE SIDEWALK DEPRESSED MONOLTrHC CLERK d GUTTER [SEE DETAIL THIS SHEET) TYPE C213 - ISOIWIETRIC VIEW (COMMERCIAL, WITH BUFFER) NOTES 1, When a driveway width exceeds 15 feet, conslmd a full depth expans Ion joint with 3/8' Joint filler a" the driveway ions lines (68B Sid, plan 1102), Construct eKpanslon joints psr Iel with the centelilne as required at IS maximum spedng When driveway widths exceed 30'. 2. See std. plan 102 for sldewslk damns. 3. Curb and gutter shown, other curb deslgm may be apecifled. Sae std. plan 101 For curb dMalla. 4. Noi used. 5. The engineer will design all driveways to Include eiavalans at all paints marked wkh symbol "X•. Al elevations are at the hack of curb top an uphill Side. 6- Not used. T. For Ddvsway Wtdit am DRIVEWAY STANDARDS (See N07E 10). The expansion jaft (see BtW. plan 102) Shall tDe specad as shown In the carresponding %omalrsc view. CEMENT CONCRETE CURB A GUTTER (SEE NOTE 3) FAeeoFetlRa BEE _ lr�OFFRET18e17 CUFm 1dETAL CONTKwr.CN JOINT - e III' ON n=ISHEYT eT7 FLAN 1C2 a Ur. r . 6 112R TOPOF ROADWAY NOTE SIRNCY46lY LIkNGITUOIrrALEAJIa19N JOKM IeYYL IY FiA-L DEPTH DEPRESSED MONOLITHIC CURS a GUTTER? DETAIL 8. Slopes shall comply with sections R303.2,1 or R3032.2 or FACE OF ADJACENT CURD R3032.3 of the Reviaed TJrLft Guii*Hi s for Acamiibl a PaUc Rigbts-af--Way Novcmhcr 23, 2005 (PROWAO). of Y 9. Curb returns for any Type C-MAX ONeway may he approved an -� s -1• R- �U1FAICE a Case -by -case basis. ,, P ••_1.R 10, STREET STANDARDS - Renton MunicipalCode (RIVIC) a TWe IV Development ReguiaUorls n , CHAPTER 6 MEET AND lUTIi3TYSTANDARD.5 SeLt3on 4-6-060 STREET STANDARDS DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMr1ERMAL DW VEIWAYS, AND ALLEYS DRIVEWAY STANDARDS - Menton Munlrlpal Cade (Rrv1C) Title IV Dovelopment Regulatlons Driveway Example: 'TYPE C18 CHAPTERS R pAFaemrN. wCamnsI - �yJ CITY-VADE PROPERTY DEVELOPMENT STAN DARD5 Nuo'b r Ki Lenea, - SettlDn 4-44M PARKING, LOADING AND DRIVEWAY CMA.K-A Lana Comrnercxq REGULATIONS B�L rh r a e awA1, WM* a Suffer STD. PLAN - 104.E PUBLIC WORKS CEMENT CONCRETE DRIVEWAY DEPARTMENT ENTRANCES -NOTES AND DETAILS 1�1_�._ � _ ._. _-- IJI�■I, SURVEYED: SCALE: KMR 1 "=20' DESIGNED: SRS DRAWN: CVP ONE INCH CHECKED: CA AT FULL SCALE IF NOT ONE INCH REVISION BY DATE A P P R ACCORDINGLY APPROVED: CASCALE Know what's below. R - 41810 7 Call before you dig. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 C T Y OF RENTON DATUM Planning/Building/Public Works Dept. AS-BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11 /10/22 (DATE SIGNED) BY: KEVIN M. REESE 11110122 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGA T SHORT PLAT ASBUIL TS CONSTRUCTION DETAILS I O O C' �V `J N J O O O 1 Q 0 DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA DRAWING NO: 20547 SHEET: ? OF: 9 r� 7V L Q an i1Eu a.nuoE s raoErrAEN PaNPEI a411N IiEE NaTH t? a'hfll __ {SEE 116TEa DEC Nf]IE it 101E ov PAYED r upPi>:wxr REauPEo 1S Fj,A,W SIOM ialfT (�.I C�]�r 13EE STO rwl I� CWlGRETE L �� T4EnaTPs R R k PA'.IP wl W T211 IY f ���,�� rFt1EMf CORLRfiTi upagfm.l s �p�Nat�i1 a A- rAw"V'Q. earn:" me Eru PµN b PLJEN VgW -Te HG'rEiT r]ti1.tAk OFF l�tln aiTr^� eawi I c'Hw cE wr � 6'RpN rsE¢[ua aG TrEn .` 8a]EWALR LT EIIYf[RONAIKTfr-1 Immu 1, --- ---- 3£CTSUH �A IaEE arG. PLNN IQIs imp po=1-EnEFCE w SLOPE rY]. �`--- �_ _��-v91MiWAY wIA�aRNE a:arE 191ooE s.lOrM E]wPGEMttPI y ___�, - a.v¢Yr.• . r uN 1.1 f.EGiNE SE�PI: LSL�E - II __ SwOWN ErA77G4•ATEGi l J- 1 fJ. ct uErrr caNcnETE s>vF�v!4x TYPE R 1 B - ISOMETRIC VIEW (RESIDENTIAL, WITH BUFFER! c[uFrl1 [olrcnETe cwe a cuTTeR IBE! n01E ]V PUBLIC WORKS CEMENT CONCRETE DRIVEWAY J DEPARTIAENT ENTRANCE - TYPE RIB 0 A PORTION OF THE SE 114 OF THE NW 114 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON 1 MIN I 1. VARIES V MIN 7rn }.TIN T MIN SPECIAL NOTES ! [ IN THE EVENT TRANSAERSE PATCHES EXIST WITHIN THE AFFECTED STREET, THE LENGTH I 11 OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EMSTIND PATCH WITHIN 10 I FEET OF THE EDGE OF THE PATCH REOUIRED FOR THE NEW CROSSING AND ANY 5U$SEOUENT PATCH EDGE WITHIN 10 FEET OF THE EDGE OF THE SECOND PATCH AND I SO ON UP TO A TOTAL OF 300 FEET- II I TRAFFIC FLOW 1 { I 1I i 2" H µA ; 2' TO B" HMA III 6.5' µIN- 2- DEPTH OF PLANING OR SAWCUT AND REMOVE FACE OF GUTTER OR EDGE OF PAVEMENT CENTER LINE OR LANE LINE VARIES: 6-5' MIN- T'DEPTH VR1ilE5 MIN µIN OF EXISTING PAVEMENT MIN MIN 2' SAWN AND REMOVE OR PLANE. SEAL WITH 2- - 6" MIN- HMA (SEE NOTE 2) AR-4000W �6- [EACH SIDE) CRUSHED SURFACING TOP COURSE (CSTC) 2' HMA (9-03.9(3)) PER WSOOT STANDARD SPECIFICARDINS, COMPACTED TO 95% MODIFIED PROCTOR, SAWCUT AFTER BACKFILL (LION SIEfE) CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL BORROW (9-03-14(1)A PER WSDOT WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GECTECH REPORT, COMPACTED TO 9SX, MODIFIED PROCTOR - MOTH MPRO OF TRENCH AS REODOT STANDARD BY SITE OF CATIOPROPOSED PLUS N ENTALL (SEE E FOR STANDARD SPECIFICATION F-pg 4) PLUS AN ALLOWANCE FOR ANY SMNSHORING, IF PIPE ZONE BEDDING- MATERIAL- SEE STANDARD NEEDED. SHALL MEET THE REQUIREMENTS TS OF WSOOT PLAN 1TO.1 STANDARD SPECIFICATION 7-00.3(1)8 TRENCH WIDTH For NorEs stD PLAN 104.2 FOR NOTF�.. SEE STANDARD PLAN 1TOA TYPICAL TRANSVERSE PATCH FOR PLAN - 11q STD. PLAN - 1U4.3 .■� PUBLIC WORKS ,, • . F' '1 E ❑ a„ DEPARTMENT FLEXIBLE PAVEMENT OR RIGID 1' P M _ J 1 PAVEMENT WIT" OVERLAY Isho 6miM Ilmmef r% Puhllc Works Administrator INITIAL 2' DEEP SAWCUT OR GRIND. AND LIMIT OF FINAL OVERLAY- CRIND AND PAVE FULL 57REET +MOTH OVERLAY REQUIRED EDGE OF EXISTING PAVEMENT EDGE OF TRAVELED LANE (EDGE STRIPE) VARIES: 4,5' MIN. (SEE STD PLAN T1D.1) CENTER OF ANY MARKED LANE LINE, PROVIOE NEW CHANNi"LJZATION AFTER OVERLAY SECONDARY FULL DEPTH SR SAWCUT FOR PROPOSEO TRENCH INITIAL 2- DEEP SAWCUT OR GRIND, AND LIMIT OF FINAL OVERLAY, GRIND AND PAVE FULL STREET WIDTH OVERLAY REQUIRED FOR TYPICAL SECTION AND NOTES SEE STANDARD PLAN 110.1 STD. pl" - PUBLIC WORKS REGUIRED SAWCUT, GRIND AND ;'I'fi DEPARTMENTOVERLAY FOR LONGITUDINAL TRENCHES Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 110 OacuSign Envulupu ID: 6EECF5BS-602A-4E4A-8436-A317AA638878 FRAME►4NG VANED GRATE 41, 8-, 1 F. OR 24- >- ONE ♦rs BAR ROOD FOR T HEIGHT INCREMENT (SPACED EpUA1LLY), SF NOTE I RECTANGULAR ADJUSTMENT SECTION 93 SAL2 EACH CORNER I � _ f 43 BAR EACH SIDE #3 BAR EACH WAY PRECAST SASE SECTION $03 BAR HDGP N3 BAR EACH CORNER 18MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PUBLIC WORKS DEPARTMENT OF WAs�t � 8285 1011912023 I N0. PIPE ALLOWANCES MAXIMUM PIPE MATERIAL Msioe MAME7ER REINFORCED OR PLAIN GONGRETE 12- ALL METAL PIPE 16, CPSSP', i2- 57D. SPEC. 9-05.28 SOLID VMEL PVC, BTD- SPEC- 9-08.12(t } 75. PROFILE WALL PVC, STD- SPEC. 9-09. 1212) 1$, ' CORRUGATED POLYETHYLENE STORM SEWERPIPE NOTESt I- AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS }PLACED IN ACCORDANCE WI TH STANDARD SPECIFICATION 9-D5-50[9}), Oft WIRE MESH HAVING A FANIMUM ARFA OF 0.12 SQUARE p'DC1iE3 PER FOOT SHALL BB USED WITH THE MINIMUM REQUIRED RESAH SHOWN IN THE ALTERNATIVE PRECAST BABE SECTION. WK MESH SHALL NOT BE PLACED IN THE KNOCKOUTS, AS AN ACCEPTABLEALTERNATIVE TD THE REBAR SHOWN W THE RFGTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED - THE KNOCKOUT DIAMETER SHALL MDT BE GREATER THAN 2D-- KMOCKO1FM SHALL HAVE A WALL THICKNESS OF,?- MINIMUM TO 2.5" MA_)MAUM PROVIDE A I,S" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PWF IS.N tTALLED, FILL THE GAPVATH JOINT MORTAR IN ACCORDANCE 9WTH STANDARD SPECIFICATION 9-04-3, 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE S FEET. 4- THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN, 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H24V OR STEEPER. B. THE OPENING SHALL BE MEASURED AT THE TOP [IF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER TkF INLET HAS BEEN PLACED- USE GROUT TYPE 2 FOR NOMSHRiNK APPLICATIONS IN ACGOROANCC WRH STANDARD SPECIFICATION 9-20-3421_ 8 ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH 8TANGARD SPECIFMATLON 9A{.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS. ANO FRAMES- 9- MORTAR SHALL BE. MIXED AND APPLIED PER MANUFACTUREMS OIRECTIONS. Itl_ FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTL FRAME IS FLUSH WITH PAViMENT AS DETERMINED WfTH A STRAIGHT EDGE DI-_ SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AHD REMAIN VISIBLE UPON COMPLETION, UNLESS 0141E 9 W HE NOTE P, PRA W ING 5 NOT TO KALE I" STD. PLAN - 20100 [YpRmto. CATCH BASIN TYPE 1 GAZ 9/28/2018 n'ni4 amn•.npaio, VATL :45 AI VARIES: 4.5' MIN, LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT 2" - 6" HMA (SEE NOTE 2) T' EDGE OF PAVEMENT, EDGE 1' OF CURB & GUTTER, DP. MIN- MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03:9(3)) PER WSDOT STANDARD 2 SAWCUT AND REMOVE SPEC€FCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4Daow CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03A9), GRAVEL BORROW (9-03.T4(T)) PER - WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEpTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF0 95% MODIFIED PROCTOR. PROPOSED IMPROVEMENT (SEE WSDOT STANDARD 5PEGIFICATIQN 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING- SHORING, IF REQUIRED By THE WSOOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS .OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSU0T STANDARD 5PEGIFICATI()N 7-08-3(1)B ' FOR STORM ANO WATER PIPE, PER STD PLAN 220.0 F- • FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH ` FOR JOINT UTILITY TRENCH, SAND WITH 95Z PASSING A #4 SIEVE AND LESS THAN 59 PASSING A #200 SIEVE NOTES 1 WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE 50 CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER 15 GREATER, 2 PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, do INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL 3" PG B4-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN S". RESIDENTIAL ACCESS STREETS - HMA CL }" PG 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4"- 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK ANIO/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT. 5, IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH' KAN- 114.1 PUBLIC WORKS FOR FLFJQBLI'e PAVEMENT OR i'F H S T:il DEPARTMENT R1401D PAVEMENT WITH OVERLAY Docu5igr) Envelope ID 6EECF5B6-602A-4E4A-S436-A317AA638878 CLEAN SURFACE AND BOTTOM AREA PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE 80TT13M AREA OF THE ADJU STME NT SECONN FRAME AND VANED GRATE ADJUSTTIIENT SECTION I I 1 I � � f i 1 � SEE NOTE 4 NOTM 1. THE COVER pR GRATING OF A CATCH BASIN SHALL NOT 13E ADJUSTEQ TO FINAL GRADE UNTIL THE FINAL ELEVATFGN OF THE PAVEMiENTGUTTER. DITCH. DR SIQEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GE4fLN BY THE ENGINEER TO MORTAR IN PLACE I N ACCOIZOANCE WITH WSDOVAPWASTANDARD SPECIE ICATION 7-M3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE THE USE GP SHIMS IS PROWSITEO. 3. A CONTINuOus LAYER OF MORTAR SHALL M PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TD PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY- THE USE OF BRICKS M PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE ARU N LNG BOND OR Y,BOND. 5: BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTFON WITH MORTAR 15, MORTAR SHALL MEET THE REpUIRE1,kT5 qF WSDp71APWA 5YAN D.ARD SPECIFICATION T- PICKY LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUY TYPE 2 FOR NON -SHRINK APPLICATIONS FN ACCORDANCE WITH STANDARO SPECIFICATION 9.20.3(2). 8, MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURE R'S DIRECTIONS. 9, FRAME SHALL BE ADJ05TE13 TO PAVEMENT GRAVE BY TAPPIM3 UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT FDGE OF SUFFICIENT LENGTH. 10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN V1518LE UPON MmPLE tKm UN LE55 ETTHE7Wl51' NOTED. DRAWING IS NOT TG WA:F INT5I STD. PLAN - 202.00 PUBLICWORKS R. DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 1 oArE :45 A Know what's below. R - 418108 Call before you dig. SURVEYED: SCALE: KMR 1 »_ 20, VERTICAL: NAVD 1988 DESIGNED: • HORIZONTAL: NAD 1983/1991 CITY OF [;R SRS R E N T O N DRAWN: CVP • ONE INCH DATU M CHECKED: CJA AT FULL Sc ALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE A P P R APPROVED: WALE SCAACCORDINGLY AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) BY: KEVIN M. REESE 4 11110122 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGA T SHORT PLAT ASBUIL TS CONSTRUCTION DETAILS II O O N O N J IN Q 0 v J DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA QD Q DRAWING NO: 20547 SHEET:8 OF: 9 00 0 DocuSign Envelop@ID:6EECF586-602A-4E4A-B436-A317AA636878 L I LI a �i 3 3 DIfTFALL TO STREAM DAMP NO POiLIIiANiS TOP 1 3EO LETTERRJO BOLT-DOVYN SLOT. SEE DETAIL AND NOTE 1 ISOMETRIC 24- 7 OR R EQUAL SPACES j DIRECTIpipF FLOW 1 516' MAX. �}.. SECTION A I I 1 114- �f } I I 11 ROLT-DOWN $Le}T [IETAII NOTES: 1. BOLT -DOWN CAPA510 TY IS REQQIREP ON AFRAM F$. GRATFS. AN13 COVERS, UNLESS OTHERWISE SPEOFIED-LL PROVIDE TWO HOLES IN Tt1E FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 516'-11 NC K 2' ALLEN HEAD CAP SCREW BY BEING TAPPED. OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. Z. REFER TO STANDARD SPECIFICATION 9-06.I SQ) FOR ADDITIONAL REQUIREMENTS 3. FOR FRAME DETAILS. SEE STAHUARD PLAN 2C4.00. SECTION B UN LESS OTHERWISE NDTTD. DRAW:NIG IS N01 TO WALE (UTSI STD. PLAN - 204.20 PUBLIC WORKS RECTANGULAR VANED GRATE Ra DEPARTMENT GAZ 9/28/2018 I DATE DocuSign Envelope IO 345B681D-914F-4F2D-AR59.7CID203B78A3 RECESSED Not LD 5cole LIFT POCKET FRAME ff/2�' 3/4' LETTERING "SEWER"❑IALAETfR(2) BOLT SOC. (ALLEN HEAD) 5/6" - 11 X 1 5 STAINLESS STEEL REF PART #00gg11771-3/16" SEE NOTE 3 1 5/W 1/4^�,2-1/2"---I -L 1 T,_1/S� �g1 3/q OAST IRON RING AND COVER BOLT DETAIL 45- (I/a) BEND etc.. F� 4+ 45' (1 /8) BEND SAND OR EXPANDABLE FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES, 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3598 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, S-O" SOUARE CONCRETE, CLASS 3000. PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 PUBLIC WORKS 8" OR 6" CLEANGUT DEPARTMENT FOR SANITARY SEWER MAIN Martin Pastucfl*26/2020 ""1�n�,kyu oATL Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433 :4 5 AN 1 12:1 A PORTION OF THE SE 114 OF THE NW 114 OF SEC. 05, T. 23 N., R. 05 E., W.M. KING COUNTY, STATE OF WASHINGTON WATER PLAN GENERAL NOTES Standard Plan No.3DD 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT IAPWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON, A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIORTO CONSTRUCTION 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION, 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER 5YSTfM IMPROVEMENTS SHALL 9E NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON-SFFE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL 8E PUSH-0N OR MECHAN[CAL JOINT. CAST IRON 0R DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250AS PER ANSI/AWWA C1201A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA CIOS STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 361NCHES FOR PIPE DIAMETER Of 104NCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHAD BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE LMUTY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FORSIZE OF PIPE USED. ALLTRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAMMUM DRY DENSITY AS DETERMINED BYTHE MODIFIED PROCTORTEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6, CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE W17H CTFY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANKALJOINT5IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIORTO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL HE TESTED AT STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURETEST, THE LJNIESHALLSE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BETAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY TILE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRE❑ FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATERSYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFIR. CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION, PUBLIC WORKS STD. PLAN — 300.0 DEPARTMENT MARCH FLAN GENERAL NOTES a MARCH 20110 DocDSlgn Envelope l❑ 345B681D-9141=-4F2D-AB59-7CT92D3B78A3 W AS�I o� co a� 7 38285IST 4 Al ---------7 Ell. SEWER MAIN PROPERTY LINE _rSPQOL [LENGTH AS NEEDED) i - o 3'-0' MIN I II 6" SEWER STUB I - :' FUTURE 4' SLOE SEWER ______ _ i I} 2"x 4" STUD MARKING POST PAINTED fi` CAP WHITE WNTii THE WORD 'SEWER" STENCILED SEWER MAIN TEE X 6' TEE i I IN 3" HICH BLACK LETTERS AHD N6 WIRE I sDEWALK w WRAPPED AROUND THE STUD AND • COUPLING M I I I C ). L_J_L_________J I a Q EXTENDED TO THE TOP OF THE STUD I # ,t 6'X6'96' SURFACE CLEANOUT WITH CAST IRON RING AND COVER 0 (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR I r APPROVED EQUAL SPECIFY 'SEWER ON LID), Rrz-A CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8'iN DEPT-I I 1 BEND AS �� 8" REQUIRED fEXISTINC SANITARY SEWER MAIN —MIN SLOPE .d>� �6" SEWER STUB 1.6-7T6-X6- WYE LFUTURE 6•- A" REDUCER SEWER MAIN SIZE x s" TEE ACCEPTABLE PROCEDURES FOR SIDE SEMR CONNECTIONS TO EXISTING SEINER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE' USING "STRONG-SACk" FLEXBLE [nuPUNGS (PERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC 'TEE- 4JSING "STRONG -BACK" FLEXIBLE COUPLINGS [FERNCO OR APPROVED EQUAL) C PVC & C9G0 PVC MAIN - CUT IN NEW TEE US+NC RIGID COUPLINGS OR CORE -DRILLED WTH A ROMAC SADDLE (OR APPROVED EQUAL) 0. DUCTILE IRON MAIN - CORE -DRILLED VAT" A fiOMAC SADDLE (OR APPROVED EQUAL) E LINFO MAIN - CONNECROte- TO SEWER MAINS THAI HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE' USING `STRONC-BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EOVAL)• F HOPE - CORE -DRILLED WITH A ROMAC SADDLE 'INSERIA-TEE' MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER C IdANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHAH 13E AT MANUFACTURED KNOCK -CUTS OR THE STRUCTURE SHALL BE CORE-ORILLEO AND USE KOR-N-SEAT. ROOFS OR APPROVED EQUAL NOTES. I PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SLIVER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 ONLESS ❑T1IERWASE SHOWN ON PLAN. SIDE SEWER SHALL HAVE A MINtNUM 25' COVER AY PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHAL_ HAVE A MINIMUM 2 71 SLOPE UNLESS APPROVED BY THE Pu BLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST HE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME OO NOT BACKFILL Ti< TRENCH uNTIL APPROVAL IS OVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RICHT-OF-WAY SHALL CONFORM TQ STANDARD PLAN 110 OR 1102 5 TIE SIDE S[MIER STUB 5HALL HAVE PrPE BEDDING IN ACCORDANCE 0I114 5TAN0ARO PLAN 4D5 7 ALL SUE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSEE] AND BONLIEQ IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN -406,1 PUBLICWORKS INSTALLATION DEPARTMENT Martin PastUetJOV26/202 (SEWER MAIN TO PROPERTY LINE) SIT. D�9EIR49D DATE 1011912023 NO. 1014106110101 1 12 13%24` PLASTIC METER BOX EWAI. TO MID -SPATES PLASTIC. INC. BCF SERIES MSBCF 1324-18 WITH 1,75 THICK DUCTILE RON AiAMONO PLATE COVER EQUAL TO MID -STATES PLASTICS, INC. MSCBC-1324-R NITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 9- MIN 12" MA: FINISH GRADE x zap - 36" MIN COVER o �+ n MTV PF?JVATE H aaTc vnlnc z I IN UNIMPROVED RIGHT OF J � WAY INSTALL METER BOX AT PROPERTY LINE WITH 12" r LONG COPPER TAILPIECE. >aa ISIDEWALK t TOUCHREAD WATER J METER TO 9E SUPPLIED BY THE CITY TYPE 'K" SOFT `v COPPER TUBING. NEW DUCTILE IRON WA TE R M A(N IF SERMCE LINE TO HOUSE IS 3/4" OR T" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD CT4-33 OR 44 FIPT PLUG x COMPRESSION COUPLING LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVDE SLACK IN COPPER COPPERSETTER FOR 5/$"x3/4" METER; FORD SERVICE LINE TO METER. VSH72-15W-44-33G, OR McDONALD BRASS: 21I-2T5WCQ033. OR MUELLER! 3/4-8-24713-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE Ci-IECK VALVE ON OUTLET L CORPORATION STOP WITH BALL VALVE. FORD COPPFRSETTER FOR 1" METER: FORD WH72-15W-44-44G, OR TAPERED THREAD [GC]. gL2ICK JOINT Mc06NALD BRASS: 21-415WCQ044. OR MUELLER' 1-S-2470-2 (:3/4" FB1000-3-0) OR AY MCDONALO 4707E BOTH INLET AND OIUTLET WITH QUICK JOINT- PADLOCK WINGS ON (T' FE1000-4-0) OR AY MCOONALD 47018 INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL 13E WITH QUICK JOINT. NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARL EXPANSION JOINTS MUSH BE INSTALLED DN BOTH SIDES OF METER BOY,. A— A DRILL 2' DIA- HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE L _ 2-1%2" MIN. FROM NEAREST F � AND FRONT EDGE OF PIT LID T,ill TYPECAL NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST I' FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. 34" PUBLIC WOR1�= AND 1" WATER SERVICE SM PLAN --- 320.1 e 4 1]liPAR'T'hil;N'[' INSIDE HOUSE PREFERRED CONFIGURATION G 5 7�11Q 8 10 4 2 FLOW # ITEM AMT 1 90' GALVANIZED STEEL ELBOW 4 EA. 2 3/4" PACKING JOINT COUPLING W/MALE IRON PIPE 2 EA. THREAD FOR COPPER PIPE SERVICE: FORD C84-33 OR EQUIVALENT FOR GALVANIZED PIPE SERVICE FORD C85-33 OR EQUIVALENT 3 PRESSURE REDUCING VALVE W/STRAINER - 3/4" 1 EA. WITH UNION COUPLINGS AT INLET AND OUTLET, WILKINS 600 SERIES OR EQUAL (WITH INTERNAL BYPASS AND STRAINER) 4 3/4" CLOSE UNION - BRASS (M X F) 1 EA. 5 3/4" BRASS VALVE VARIABLE 6 12" STANDARD METER BOX W/SOLID COVER 1 EA. CONCRETE: 17 1/4 X 28 5/8 INSIDE DIMENSIONS, EQUAL TO FOG TITE METER SEAL CO. +2 PLASTIC: 13 X 24 1 INSIDE DIMENSIONS, EQUAL TO BROOKS METER BOX 7 3/4" GALVANIZED STEEL PIPE, THREADED, LENGTH AS VARIABLE REQUIRED 8 3/4" X 1/4" X 3/4" STD. BRASS TEE 1 EA. 9 1/4" PETCOCK (M X F) 1 EA. 10 3/4" BRASS NIPPLE VARIABLE ADJACENT TO WATER METER PROPERTY LINE SAWDUST 5 6 9 5 FILL Mal 24" MIN 7 7 6" �7 FROM 6" P A L WATER TYP METER 1 10 3 70 8 10 4 2O FLOW 2 FUNCTION THE FUNCTION OF A PRESSURE REDUCING VALVE IS TO REDUCE HIGH-WATER PRESSURES IN THE SERVICE CONNECTION TO AN ACCEPTABLE RANGE OF 55 TO 75 PSI INSTALLATION OF A PRESSURE REDUCING VALVE IS REQUIRED WHERE THE SERVICE CONNECTION PRESSURE EXCEEDS 80 POUNDS PER SQUARE INCH IN ACCORDANCE TO THE UNIFORM PLUMBING CODE. INSTALLATION THE PRESSURE REDUCING VALVE SHALL BE LOCATED ON THE CUSTOMER'S PROPERTY "DOWNSTREAM" OF THE METER BOX. RESPONSIBILITY FOR PROPER INSTALLATION, OPERATION, AND MAINTENANCE OF THE VALVE SHALL BE ASSUMED BY THE CUSTOMER. THREE POSSIBLE CONFIGURATIONS FOR INSTALLATION OF THE VALVE ARE SHOWN ABOVE. A BUILDING DEPARTMENT PLUMBING PERMIT IS REQUIRED PRIOR TO INSTALLATION 1 STD. PLAN — 340.5 e PUBLIC WORKS 3 " & 1" INDIVIDUAL PRESSURE REDUCING DEPARTMENT VALVE ASSEMBLY MARCH 2O10 SURVEYED: KMR DESIGNED: SRS DRAWN: CVP CHECKED: CJA BY DATE APPR APPROVED: CJA Know what's below. R 41810 9 Call before you dig. SCALE: 1„-20' HORIZONTAL: VERTICAL: NAVD C TY OF NAD 1983/183/1991 RENTON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY AS -BUILT DRAWINGS PLAN THESE AS —BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 11/10/22 (DATE SIGNED) By: KEVI N M. REESE 11110122 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR N COMPLIANCE WITH CITY OF RENTON STANDARDS MANGAT SHORT PLAT ASBUILTS CONSTRUCTION DETAILS III N U O N Q 0 v J DATE: 1011912023 FIELDBOOK: N/A PAGE: NIA DRAWING NO: 20541 SHEET: n OF: n