6'x12' FRAME, GRATE, & SOLID COVER WITH LOCKING BOLTS.
KCRDCS DWG 7-022,7-023
RIM=449.64-
368.00
IN
0
crf
O
m
w
IJ
i0
0
3" X 0.090" GAGE SUPPORT
BRACKET ANCHORED TO
CONCRETE WALL. (MAX. 3'
VERTICAL SPACING)
3' MIN
24" OUTLET PIPE
TO STORMFILTER
of
w
cn
m
U
O
ro
BOTTOM OF VAULT LID EL=367.00
MAXIMUM DESIGN WATER
SURFACE EL=366.50
p ..
° SAFETY HANDHOLES,
STEPS, OR LADDER.
SEE KCRDCS DWG
7-006.
v
ORIFICE 0=2-5/16"
ORIFICE #3
IE=363.75 (6")
ELBOW RESTRICTOR
D 'p
ORIFICE 0=2-1/8"
ORIFICE ##2
IE=361.50 (6")
° ELBOW RESTRICTOR
D
0
D
by
v 8" SHEAR GATE W/CONTROL ROD FOR
CLEANOUT/DRAIN (ROD BENT AS REQUIRED
FOR VERTICAL ALIGNMENT WITH COVER).
SEE KCRDCS DWG 7-026.
D
p ..
ASBUILT DRAINAGE FACILITY DETAILS
OF
FOREST TERRACE PLAT
A PORTION OF SECTION 04, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
J
=
STATIC WATER SURFACE
IE=i555.519 (18
b
355.57
355.57 (24 ")
°
N
v
b
D
v
M
N
N
0
N
N
P
N
�
N
12"
MAX.
(TYP.)
v
P
rn
v b
NOTES:
Z
D
°
1. ALL METAL PARTS MUST BE CORROSION
Z
RESTRICTOR PLATE WITH
BOTTOM
OF SUMP EL=351.50
RESISTANT. STEEL PARTS MUST BE
z
w
ORIFICE #1 0=2-1/32"
STAINLESS STEEL OR ALUMINIZED STEEL.
EL=353.50
2. PROVIDE WATER STOP AT ALLCAST-IN-PLACE
o
CONTROL
STRUCTURE
CONSTRUCTION JOINTS.
VAULT
PRECAST VAULTS HAVEIE APPROVED
RUBBER GASKET SYSTEM.
W
SCALE: 1 =2
0
J
3
BENCHMARK
FOUND PUNCHMARK IN 1 Y4" BRASS FOUND PUNCHMARK IN Y8" BRASS PIN
DATUM DISK IN CONCRETE MONUMENT IN CASE IN CONCRETE MONUMENT IN CASE
0.4' BELOW GRADE (7/20/2017) 1.4' BELOW GRADE (7/20/2017)
HORIZONTAL DATUM: VERTICAL DATUM: OBSERVED (NAD 83/11) OBSERVED (NAD 83/11)
NAD '83/'11 NAVD '88 N:191092.94, E:1311476.14 N:191241.77, E:1311481.30
1 I RECORD DRAWINGS AS BUILT
NO.
(4'-5")
TOP SLAB ACCESS
SEE FRAME AND
COVER DETAIL
FILTRATION BAY
(3'-7")
ALTERNATE PIPE
LOCATION (TYP)
A
A
co
OUTLET
INLET
FLOW v
A
:..
OUTLET
INLET BAY
STORMFILTER
BAY
CARTRIDGE
6" CONCRETE
WALL WIDTH
12'-0"
MAY VARY
REGIONALLY
PLAN VIEW
VAULT STYLE: INLET BAY - OUTLET BAY
•l,
STEP
:.S
w
a
INLET PIPE
F
J Q
4••
�w
i U)
•
oz
i
WLL
w
wa
77,
1,
77
f.
PERMANENT
STORMFILTER
LL
POOL ELEV.
CARTRIDGE
j
0 z
FLOW KIT OUTLET PIPE
p Z -
U H w
FLOW SPREADER & BAFFLE
w -i
WALL (TYP OF 2)
-0
O
ENERGYY
SECTION A -A
DISSIPATOR
REVISION
m.smnn w "M
StormFilter•
STORMFILTER DESIGN NOTES
STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD VAULT
STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (11), VAULT STYLE OPTIONS INCLUDE, OUTLET BAY (11), FULL HEIGHT BAFFLE WALL
(12). STORMFILTER 6X12 PEAK HYDRAULIC CAPACITY IS 1.6 CFS. IF THE SITE CONDITIONS EXCEED 1.6 CFS AN UPSTREAM BYPASS STRUCTURE IS
REQUIRED.
CARTRIDGE SELECTION
CARTRIDGE HEIGHT
27"
18"
LOW DROP
RECOMMENDED HYDRAULIC DROP (H)
3.05'
2.3'
1.8'
SPECIFIC FLOW RATE (gpm/sf)
2 gpm/sf
1.67` gpm/sf
1 gpm/sf
2 gpm/sf
1.67" gpm/sf
1 gpm/sf
2 gpm/sf
1.67" gpm/sf
1 gpm/sf
CARTRIDGE FLOW RATE (gpm)
22.5
1 18.79
1 11.25
1 15
1 12.53
1 7.5
10
1 8.35
1 5
' 1.67 gpm/sf SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB® (PSORB) MEDIA ONLY
FRAME AND COVER
(DIAMETER VARIES)
N.T.S.
SITE SPECIFIC
DATA REQUIREMENTS
STRUCTUREID
WATER QUALITY FLOW RATE (cfs)
0.35
PEAK FLOW RATE (cfs)
7.43
RETURN PERIOD OF PEAK FLOW (yrs)
100-YR
CARTRIDGE HEIGHT (27", 18", LOW DROP(LD))
27"
NUMBER OF CARTRIDGES REQUIRED
14
CARTRIDGE FLOW RATE
MEDIA TYPE (PERLITE, ZPG, PSORB)
ZPG
PIPE DATA:
I.E.
MATERIAL
DIAMETER
INLET PIPE #1
355.48
LCPE
24"
INLET PIPE #2
OUTLET PIPE
352.43
LCPE
24"
UPSTREAM RIM ELEVATION
362.85
DOWNSTREAM RIM ELEVATION
362.40
ANTI -FLOTATION BALLAST
WIDTH
HEIGHT
NOTES/SPECIAL REQUIREMENTS:
" PER ENGINEER OF RECORD
GENERALNOTES
1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY.
3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS
LLC REPRESENTATIVE. www.ContechES.com
4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS
DRAWING.
5. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0'- 5' AND GROUNDWATER ELEVATION AT, OR BELOW, THE
OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO
M306 AND BE CAST WITH THE CONTECH LOGO.
6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL
BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS.
7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft).
8. STORMFILTER STRUCTURE SHALL BE PRECAST CONFORMING TO ASTM C-857 AND AASHTO LOAD FACTOR DESIGN METHOD.
INSTALLATION NOTES
A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE
SPECIFIED BY ENGINEER OF RECORD.
B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER VAULT (LIFTING
CLUTCHES PROVIDED).
C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL VAULT SECTIONS AND ASSEMBLE VAULT.
D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR.
E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF.
I- l4t
o Z
Z
y 423 p ��
�0
�F
S T 0,
NA L E�0\
2/ 7/21
V
G
V
`YI
7
m
•�
0
im
i
Z
All
W
c:
�
fV
M
i
a
05
m
�QQq
N
i
O
L0
a-7 f V
N
/c�a
W
V
r
a)
Y"t
R-404828�
ini rnnnIDi innirF XnnTu riTv nG RGnirnni eTnninnrzne
r-
co
CD
O
O
O
I
co
Q
LLJ
(0
Uco
00
=
O
TJS
1 /12/22
BJT
suRmED:
VERTICAL- NAw ,
HORIZONTAL NAD 1983 199,
CITY OF
ASBUILT DRAINAGE FACILITY DETAILS
DATE,
/7/2022
LLJ
m
DESIGN TJS
FOREST TERRACE PLAT
F-
OO
F� BOOK:
RENTON
('
DRAWN:
TJS
PULTE GROUP, I N l�
DRAWING NO:
ONE INCH
AT FULL SCJLLE
IF NOT ONE INCH
DATUM
Planning/Building/Public Works Dept.
3535 FACTORIA BLVD S.E., #600
LLJ
W
CHECKED:
eJT
APP T
SHEET: ^8 GF: 89
BY
DATE
APPR
SCALE ACCORDINGLY
BELLEVUE, WA 98006
O
L
LL
m