Loading...
HomeMy WebLinkAboutMFP21003040.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21003040 IVR Number: 21003040 Permit Information Permit Name: ExteNet Systems - Fiber - EXTENET TUKWILA - PHASE 1 - SEG 1 - S-007447 P-023634Address/Location:06/29/2021Application Date:3623049111Parcel Number: 1600 SW 43RD ST Permit Type:10/27/2021Issue Date:Franchise Permit Work Class:10/27/2022Expiration Date:Major Utility Job Number: SEG 1 - S-007447 P-023634Franchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 EXTENET TUKWILA PHASE 1 SEG 1 S 007447 P 023634 PROOF EXISTING CITY OF RENTON HANDHOLDS AND CONDUIT ALONG S 180TH ST. Contacts Name Address PhoneTypeBilling Rachel Fenton Extenet Systems LLC 3030 Warrenville Rd Lisle, IL 60532 Applicant MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 ApplicantX Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 OAKESDALE BUSINESS PARK LLC 11225 SE 6TH STREET STE 215 BELLEVUE , WA 98004 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP21003040 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 10/27/2021 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RONLYCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 111Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (WEST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYS 180TH ST / SR 18118012 WEST VALLEYHWY SPARCEL NO.0000200017 7120 S 180TH STPARCEL NO.3623049039PARCEL NO.3623049037WEST VALLEY HWYW20-1W20-5RW4-2RXXXL2' MINWORKVEHICLEW20-1W20-1W20-1W20-1AVE S 71ST 72ND AVE S WORK AREA 10'X10'this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RONLYONLYCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 211Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)7200 S 180TH STPARCEL NO.3623049013PARCEL NO.0000200008S 180TH STW20-171ST AVE S 72ND AVE S 7120 S 180TH STPARCEL NO.362304903917900 WEST VALLEYHWYPARCEL NO.3623049011WORK AREA 10'X10'WORKVEHICLE2' MINL50'-100'XW20-1X W20-5RW20-1W20-1W20-5RW4-2RXXTRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (WEST BOUND LANE)W20-1this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RONLYONLYCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 311Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)7200 S 180TH STPARCEL NO.3623049013PARCEL NO.0000200008S 180TH ST72ND AVE S 17900 WEST VALLEYHWYPARCEL NO.3623049011WORK AREA 10'X10'WORKVEHICLE2' MINLXW20-1W20-1W20-1W20-5RW4-2RXXTRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (WEST BOUND LANE)50'-100'W20-1this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RBNSF R/W UP R/W CITY OF RENTON CITY OF TUKWILACITY OF KENTCITY OF TUKWILABNSF R/W BNSF R/W UP R/W CITY OF RENTON CITY OF TUKWILACITY OF KENTCITY OF TUKWILAUP R/W CONFIDENTIAL/PROPRIETARYSHEET: OF 411Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORK AREA 10'X10'WORKVEHICLE2' MINLXW20-1W20-1W20-5RW4-2RXXTRAFFIC CONTROL PLAN #4 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (WEST BOUND LANE)50'-100'17900 WEST VALLEYHWYPARCEL NO.3623049011 18000 72ND AVE SPARCEL NO.0000200012this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RBNSF R/WBNSF R/W BNSF R/W CITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 511JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRTRAFFIC CONTROL PLAN #5 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (WEST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE2' MINWORK AREA 10'X10' 1600 SW 43RD STPARCEL NO.3623049111PARCEL NO.1253710060 7421 S 180TH STPARCEL NO.3623049018PARCEL NO.3623049002LW20-1W20-150'-100'W20-1X W20-5RW20-1W20-5RW4-2RXXXMFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RBNSF R/WBNSF R/W BNSF R/W CITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 611JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE W PEDESTRIAN ESSCORT (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE 2' MINW20-150'-100'WORK AREA 10'X10' 1600 SW 43RD STPARCEL NO.3623049111PARCEL NO.1253710060 7421 S 180TH STPARCEL NO.3623049018PARCEL NO.3623049002LW20-1W20-5RW4-2RXXXW20-5RW20-1X SPOTTER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONEFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLW20-1TRAFFIC CONTROL PLAN #6 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (EAST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYMFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 711JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE2' MINW20-150'-100'WORK AREA 10'X10' 1600 SW 43RD STPARCEL NO.3623049111PARCEL NO.1253710060 7421 S 180TH STPARCEL NO.3623049018PARCEL NO.3623049002LW20-1W20-5RW4-2RXXW20-5RW20-1X W20-1TRAFFIC CONTROL PLAN #7 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (EAST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYWORK AREA 10'X10'W20-11412 SW 43RD STPARCEL NO.3623049110 7835 S 180TH STPARCEL NO.1253710050MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 811JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE 2' MINW20-150'-100'WORK AREA 10'X10'LW20-1W20-5RW4-2RXXW20-1W20-1TRAFFIC CONTROL PLAN #8 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (EAST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYW20-11412 SW 43RD STPARCEL NO.3623049110 7835 S 180TH STPARCEL NO.1253710050XMFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 911JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE 2' MINW20-150'-100'WORK AREA 10'X10'LW20-1W20-5RW4-2RXXW20-1TRAFFIC CONTROL PLAN #9 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (EAST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYW20-1XPARCEL NO.3623049045 7835 S 180TH STPARCEL NO.12537100501412 SW 43RD STPARCEL NO.3623049110 7835 S 180TH STPARCEL NO.1253710050MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 1011JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)S 180TH STWORKVEHICLE 2' MINW20-150'-100'WORK AREA 10'X10'LW20-1W20-5RW4-2RXXW20-1TRAFFIC CONTROL PLAN #10 - USE SET-UP WHERE APPLICABLE ALONG S 180TH ST (EAST BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYW20-1XPARCEL NO.3623049045 7835 S 180TH STPARCEL NO.125371005080TH AVE S 1200 SW 43RD STPARCEL NO.36230491087979 S 180TH STPARCEL NO.3623049086MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: TUKWILA, WA 98188 RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL - TCPS.dwgPERMIT NUMBER: RONLY CITY OF KENT CITY OF RENTON CONFIDENTIAL/PROPRIETARYSHEET: OF 1111JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTKnow what'sbelow.before you dig.CallRSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH 22517 88THAVE S KENT, WA 98031 C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYWORK AREA 10'X10'W20-5RW20-1X W20-1WORKVEHICLE2' MIN50'-100'S 180TH ST 7979 S 180TH STPARCEL NO.36230490861200 SW 43RD STPARCEL NO.3623049108SW 43RD ST80TH AVE S8009 S 180TH STPARCEL NO.36230491001001 SW 41ST STPARCEL NO.3623049112LW20-1W20-5RW4-2RXXXTRAFFIC CONTROL PLAN #11 - USE SET-UP WHERE APPLICABLE ALONG 80TH AVE S (SOUTH BOUND LANE)W20-1this work is in the city of Kent'sROW. Approval from Kent willbe needed for work in theirROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RSITE LOCATIONSHEET INDEXSCOPE OF WORK:PULL THROUGH EXISTING CTL/LUMENFACILITIES ALONG S 180TH ST, FROM THENORTHEAST CORNER OF S 180TH ST ANDWEST VALLEY HWY TO THE CITY OF RENTONRIGHT OF WAY.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 114NORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMADDRESS: 7120 S 180TH ST, TUKWILA, WA 98188PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMSTARTSHEET 4SHEET 5SH E E T 6 S H E E T 7 ENDS H E E T 8 1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-12. DESIGN VIEWS A-I13-14. SITE PHOTOGRAPHSS H E E T 9 S H E E T 1 0 S H E E T 1 1 S H E E T 1 2 MFP21003040This permit is for Major construction work in the ROW and will be billed at an additional$60/HR for inspections. After hours and weekend work will be billed at $125/HR NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 214#F#F#F##LEGENDMFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF TUKWILA ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 314The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF TUKWILA REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF TUKWILA INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF TUKWILA INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF TUKWILA AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF TUKWILA, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF TUKWILA.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF TUKWILA INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF TUKWILA.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 414DESIGN VIEW A CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 5S 180TH STWEST VALLEY HWY / SR 18118012 WEST VALLEYHWY SPARCEL NO.0000200017 7120 S 180TH STPARCEL NO.3623049039PARCEL NO.362304903771ST AVE S 100' 52' 18' 47' 69'13'126' 11'11'11'11'12'12'61'23'65'74'28'16'12'12'12'11'11'21207'STATION LINE START ATSPERRY DR SMH 1641MATCH TO EXTENET TUKWILA -PHASE 1 - SEG 3 - S-007452 P-023639 -CTL/LUMEN DIG AND FIX PLANS MATCH TO EXTENET TUKWILA -PHASE 1 - SEG 2 - S-007449 P-023636 CTL PLANSthis work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 514DESIGN VIEW B Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MATCH TO SHEET 4 MATCH TO SHEET 6S 180TH ST7200 S 180TH STPARCEL NO.362304901371ST AVE S18016 71ST AVE SPARCEL NO.3585290020PARCEL NO.000020000882' 28' 1' 54' 54'28' 11'10'16'11'65'52'13'27'50'12'14'12'12'14'72ND AVE S 2112137'210'32'2MH 444MH 43323this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RUP R/W UP R/WCITY OF KENTCITY OF TUKWILACONFIDENTIAL/PROPRIETARYSHEET: OF 614DESIGN VIEW C Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MATCH TO SHEET 5 MATCH TO SHEET 7S 180TH ST17900 WEST VALLEYHWYPARCEL NO.362304901182'28'1'54'53'28'11'10'10'12' 18000 72ND AVE SPARCEL NO.00002000122314'4MH 43561'21this work is in the city ofTukwila's ROW. Approval fromTukwila will be needed for workin their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RBNSF R/W BNSF R/W CITY OF RENTONCITY OF TUKWILACITY OF KENTCONFIDENTIAL/PROPRIETARYSHEET: OF 714CONSTRUCTION NOTESDESIGN VIEW D Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MATCH TO SHEET 6 S 180TH ST 7421 S 180TH STPARCEL NO.362304901883' 45' 19' 38' 51'13' 15'12'11'14'PARCEL NO.3623049002134'2MATCH TO SHEET 82238'this work is in thecity of Tukwila'sROW. Approval fromTukwila will beneeded for work intheir ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 814CONSTRUCTION NOTESDESIGN VIEW E Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL(1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MATCH TO SHEET 7 S 180TH ST / SW 43RD ST 1600 SW 43RD STPARCEL NO.362304911184'45'19'38'52'13'15'11'11'14'PARCEL NO.1253710060 7421 S 180TH STPARCEL NO.3623049018PARCEL NO.36230490022211MH 7430MH 437132'85'561 4" VACANT2-1.25 INNER-DUCTVACANTPLACED MULE TAPE384 FT1 4" VACANT2-1.25 INNER-DUCTVACANTPLACED MULE TAPE166 FTMCI VAULT3256'133EXISTING (1) 4" CTL/LUMEN CONDUIT WITH (1) OCCUPIED1.25 INNERDUCT (72 CT FIBER & 50x) PULL (1) 1728F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.55'MATCH TO SHEET 9 MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 914DESIGN VIEW F Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESMATCH TO SHEET 8 MATCH TO SHEET 10 S 180TH ST / SW 43RD ST 1508 SW 43RD STPARCEL NO.3623049042107'47'23'60'48'36'11'11'11'11' 7835 S 180TH STPARCEL NO.1253710050PARCEL NO.3623049115314107'265'MH 27931EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL(1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.3EXISTING (1) 4" CTL/LUMEN CONDUIT WITH (1) OCCUPIED1.25 INNERDUCT (72 CT FIBER & 50x) PULL (1) 1728F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.4EXISTING (1) 4" CTL/LUMEN OCCUPIED CONDUIT (72 CTFIBER & 600PAIR) PULL (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 1014DESIGN VIEW G Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 11 S 180TH ST / SW 43RD ST1412 SW 43RD STPARCEL NO.3623049110103' 49' 21' 54' 56'26' 11'11'11'11' 7835 S 180TH STPARCEL NO.125371005011' MATCH TO SHEET 9 5CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL(1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.5EXISTING (1) 4" CTL/LUMEN CONDUIT WITH (1) OCCUPIED1.25 INNERDUCT (600PAIR) PULL (1) 1728F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.5149'323'MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 1114DESIGN VIEW H Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 10 MATCH TO SHEET 12 S 180TH ST / SW 43RD STPARCEL NO.3623049045103'49'21'54'56'26'12'11'11'11' 7835 S 180TH STPARCEL NO.125371005011'1250 SW 43RD STPARCEL NO.362304911414570'MH 4394CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL(1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.5EXISTING (1) 4" CTL/LUMEN CONDUIT WITH (1) OCCUPIED1.25 INNERDUCT (600PAIR) PULL (1) 1728F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.4EXISTING (1) 4" CTL/LUMEN OCCUPIED CONDUIT (72 CTFIBER & 600PAIR) PULL (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.1547'264'MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCITY OF KENTCITY OF RENTONCONFIDENTIAL/PROPRIETARYSHEET: OF 1214DESIGN VIEW I Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #13-14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 11 CONSTRUCTION NOTESS 180TH ST / SW 43RD ST1200 SW 43RD STPARCEL NO.362304910891' 47' 20' 44' 56'16' 11'11'11'11'7979 S 180TH STPARCEL NO.362304908611'1250 SW 43RD STPARCEL NO.362304911480TH AVE S 91'44'47'16'56'19'11'11'11'11'12'5444 NOTE 11218'OAKESDALE AVE S 1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL(1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.5EXISTING (1) 4" CTL/LUMEN CONDUIT WITH (1) OCCUPIED1.25 INNERDUCT (600PAIR) PULL (1) 1728F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.this work is in thecity of Kent's ROW.Approval from Kentwill be needed forwork in their ROW.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1314Know what'sbelow.before you dig.CallRCONSTRUCTION NOTESPHOTO #1: FACING EAST ON NORTH SIDE OF S 180TH ST121221222PHOTO #2: FACING WEST ON NORTH SIDE OF S 180TH STPHOTO #3: FACING WEST ON NORTH SIDE OF S 180TH ST12PHOTO #4: FACING EAST ON NORTH SIDE OF S 180TH ST1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MFP21003040 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 7120 S 180TH ST TUKWILA, WA 98188DRAWING NAME: NORTH SKY - EXTENET TUKWILA - PHASE 1 - SEG 1 S-007447 P-023634 - CTL PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 1414Know what'sbelow.before you dig.CallRCONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)1728F CABLE THROUGH. CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TO WORK.2EXISTING (1) 4" CTL/LUMEN CONDUIT. PULL (3) 1.25"INNERDUCTS AND (1) 1728F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.PHOTO #5: FACING WEST ON NORTH SIDE OF S 180TH STPHOTO #6: FACING EAST ON SOUTH SIDE OF S 180TH ST12212MFP21003040