HomeMy WebLinkAboutMFP21004686.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP21004686
IVR Number: 21004686
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:09/21/2021Application Date:6198400125Parcel Number: 19016 116TH AVE SE
Permit Type:10/28/2021Issue Date:Franchise
Permit Work Class:10/28/2022Expiration Date:Minor Utility
Job Number: 755889Franchise Type:Cable
Description: Comcast proposes to bore and place conduit with .875 coax 137'. Place ne riser and pedestal. Pothole all existing
utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Applicant
Carissa Morris
Sefnco Communications
Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Scott Nall
SEFNCO Communications Inc
2904 4th Ave NE
Puyallup, WA 98372
B: (877) 385-2903
C: (253) 444-9057
Contractor
Business License Number: 41108Construction Contractor: SEFNCCI850QD
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
SEFNCO Communications, Inc.
SEFNCC1850QD BLO29666
Comcast Cable Communications Management, LLC
253 235-7406
owen_shackett@comcast.comCody Shackett
JB0000755889
19016 116th Ave SE Wang Short Plat
Comcast proposes
253-999-2271
to bore & place conduit w/.875 coax ~137'; Place new riser; Place new
pedestal.
137'
9/21/2021
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 3/18/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 3/18/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
▪ Include map(s) showing the location of the project and work area.
▪ Be legible lettering and clear, contrasting, symbols of viewing or printing.
▪ Must indicate street names, and north arrow and scale.
▪ Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
SEFNCO Communications
Ashley Kiehn (253) 999-2271
4610 Tacoma Ave Sumner, WA 98390
9:00am 3:30pm
JB0000755889 - Wang Short Plat
19016 116th Ave SE
Comcast proposes to bore & place conduit w/ .875 coax ~137'; Place new riser; Place new
pedestal.
10/21/21 11/03/21
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 3/18/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
• Must have approved Traffic Control Plan (TCP) prior to commencing the work.
• Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
• WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
• All permit conditions shall be met.
NOTES:
• Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
• Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
• In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 3/18/2021
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
FOCFOCEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WEOPFOCFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOP EOP
EOP EOP EOP SWSWSWSWSW116TH AVE SESE 190TH LN
PRIVATE ROAD
←DRIVEWAY→←DRIVEWAY→
←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←D
R
I
V
E
W
A
Y
→
←DRIVEWAY→
←DRIVEWAY→11464 SE 191ST CT,RENTON, WA 98055, USA11458 SE 191ST CT,RENTON, WA 98055, USA19116 116TH AVE SE,RENTON, WA 98058, USA11527 SE 190TH LN,RENTON, WA 98055, USA19100 116TH AVE SE,RENTON, WA 98058, USA19030 116TH AVE SE,RENTON, WA 98058, USA19021 116TH AVE SE,RENTON, WA 98058, USA19015 116TH AVE SE,RENTON, WA 98058, USA19009 116TH AVE SE,RENTON, WA 98058, USA19003 116TH AVE SE,RENTON, WA 98058, USA11645 SE 189TH PL,RENTON, WA 98058, USA11639 SE 189TH PL,RENTON, WA 98058, USADBDBDBDB92'19016 116TH AVE SE,RENTON, WA 98058, USAWORKVEHICLEWORKZONEPOLE 1WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTNREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC
CONTROL
PLAN-113ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7040/5540/5540/2525DISTANCEABCD1000' +/-1000' +/-1000' +/-1000' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-200' +/-100' +/-SPEEDLONGITUDINAL BUFFER SPACE = BLENGTHÄÄÄÄÄLANEWIDTHMINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)GENERAL NOTE:1.ALL ROW WORK MUST YIELD TO SCHOOLTRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPEDOR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS,DEPART: COMMENCE WORK.CONSTRUCTION TCP NOTES:1. /#+06#+0&4+8'9#;#%%'55#6#..6+/'52. 5+&'9#.-#4''+6*'412'01401612'0#5+&'9#.-+5%.15'&+(#/+0+/7/2#6*%#0016$'/#+06#+0'&/'#574'&(41/2412'46;.+0'14+(%4'#6'&(41/(#%'1(%74$(PEDESTRIAN PATH PROVIDED WHEREREQUIRED)#0&9+..$'MONITORED BY A SPOTTER TO INSUREFLOW AND SAFETY DURING WORK UNLESS OTHERWISENOTED.SPOTTER IS NOT TO CONTROL TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADACOMPLIANCE#..%10641.5'6Ä725+)052#%+0)#0&241%'&74'59+..%10(14/6152'%+(+%#6+10556#6'&+06*'('&'4#./#07#.1070+(14/'&64#((+%%10641.&'8+%'5
/76%&%+6+'5#0&8#4+175/70+%+2#.+6+'5/#;*#8'#.51#&126'&52'%+#.+<'&)7+&'.+0'5(1464#((+%%10641.9+6*+06*'+4,74+5&+%6+10+6+56*'4'52105+$+.+6;1(6*'10Ä5+6'64#((+%%10641.2'4510#.615''+(#0�52'%+#.%10&+6+105':+56(.#))'455*#..$'75'&+0#%%14�%'9+6*9#%ÄÄ+(10.;10'.#0'+512'0+0#&+4'%6+106*#6.#0'5*#..$'#/+0+/7/1(9+&'70.'5552166'4(.#))'45#4'75'&+09*+%*%#5'6*'.#0'%#0$'#/+0+/7/1(TABLE 6C-2SHOULDERWORKBROADWORKAHEADA
FOC EOPFOCFOCFOCFOCFOCSWSWSWSWSWSWSWFOC FOCR/W R/WR/WR/WR/WR/WR/WSW SW SW
SWSWR/W R/W
EOP EOP
EOP EOPEOPEOPEOP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→PRIVATE ROADPRIVATE ROAD
SE 191ST ST117TH PL SE
19140 117TH PL SE,RENTON, WA 98058, USA19134 117TH PL SE,RENTON, WA 98058, USA11719 SE 191 ST,RENTON, WA 98058, USA11725 SE 191 ST,RENTON, WA 98058, USA11731 SE 191 ST,RENTON, WA 98058, USA11737 SE 191 ST,RENTON, WA 98058, USA11743 SE 191 ST,RENTON, WA 98058, USA11805 SE 191 ST,RENTON, WA 98058, USA11811 SE 191 ST,RENTON, WA 98058, USA11823 SE 191 ST,RENTON, WA 98058, USA11829 SE 191 ST,RENTON, WA 98058, USA11835 SE 191ST, RENTON,WA 98058, USA11806 SE 191 ST,RENTON, WA 98058, USA11752 SE 191 ST,RENTON, WA 98058, USA11740 SE 191 ST,RENTON, WA 98058, USA19113 117TH PL SE,RENTON, WA 98058, USA19119 117TH PL SE,RENTON, WA 98058, USA11668 SE 189TH PL,RENTON, WA 98058, USA19135 117TH PL SE,RENTON, WA 98058, USA19141 117TH PL SE,RENTON, WA 98058, USA
PPDB DBDBDB45'WORKVEHICLEWORKZONE←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTNREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC
CONTROL
PLAN-223ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7040/5540/5540/2525DISTANCEABCD1000' +/-1000' +/-1000' +/-1000' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-200' +/-100' +/-SPEEDLONGITUDINAL BUFFER SPACE = BLENGTHÄÄÄÄÄLANEWIDTHMINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)GENERAL NOTE:1.ALL ROW WORK MUST YIELD TO SCHOOLTRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPEDOR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS,DEPART: COMMENCE WORK.CONSTRUCTION TCP NOTES:1. /#+06#+0&4+8'9#;#%%'55#6#..6+/'52. 5+&'9#.-#4''+6*'412'01401612'0#5+&'9#.-+5%.15'&+(#/+0+/7/2#6*%#0016$'/#+06#+0'&/'#574'&(41/2412'46;.+0'14+(%4'#6'&(41/(#%'1(%74$(PEDESTRIAN PATH PROVIDED WHEREREQUIRED)#0&9+..$'MONITORED BY A SPOTTER TO INSUREFLOW AND SAFETY DURING WORK UNLESS OTHERWISENOTED.SPOTTER IS NOT TO CONTROL TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADACOMPLIANCE#..%10641.5'6Ä725+)052#%+0)#0&241%'&74'59+..%10(14/6152'%+(+%#6+10556#6'&+06*'('&'4#./#07#.1070+(14/'&64#((+%%10641.&'8+%'5
/76%&%+6+'5#0&8#4+175/70+%+2#.+6+'5/#;*#8'#.51#&126'&52'%+#.+<'&)7+&'.+0'5(1464#((+%%10641.9+6*+06*'+4,74+5&+%6+10+6+56*'4'52105+$+.+6;1(6*'10Ä5+6'64#((+%%10641.2'4510#.615''+(#0�52'%+#.%10&+6+105':+56(.#))'455*#..$'75'&+0#%%14�%'9+6*9#%ÄÄ+(10.;10'.#0'+512'0+0#&+4'%6+106*#6.#0'5*#..$'#/+0+/7/1(9+&'70.'5552166'4(.#))'45#4'75'&+09*+%*%#5'6*'.#0'%#0$'#/+0+/7/1(TABLE 6C-2CBONELANEROADAHEAD
ROADWORKAHEAD
LIMIT
SPEED R2-1
25ACBONELANEROADAHEADROADWORKAHEADLIMITSPEEDR2-125ASPOTTERFLAGGER
FLAGGER
FOC EOPFOCFOCFOCFOCFOCSWSWSWSWSWSWSWFOC FOCR/W R/WR/WR/WR/WR/WR/WR/WSW SW SW
SWSWR/W R/W
EOP EOP
EOP EOPEOPEOPEOP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→←DRIVEWAY→PRIVATE ROADPRIVATE ROAD
SE 191ST ST117TH PL SE
19140 117TH PL SE,RENTON, WA 98058, USA19134 117TH PL SE,RENTON, WA 98058, USA11719 SE 191 ST,RENTON, WA 98058, USA11725 SE 191 ST,RENTON, WA 98058, USA11731 SE 191 ST,RENTON, WA 98058, USA11737 SE 191 ST,RENTON, WA 98058, USA11743 SE 191 ST,RENTON, WA 98058, USA11805 SE 191 ST,RENTON, WA 98058, USA11811 SE 191 ST,RENTON, WA 98058, USA11823 SE 191 ST,RENTON, WA 98058, USA11829 SE 191 ST,RENTON, WA 98058, USA11835 SE 191ST, RENTON,WA 98058, USA11806 SE 191 ST,RENTON, WA 98058, USA11752 SE 191 ST,RENTON, WA 98058, USA11740 SE 191 ST,RENTON, WA 98058, USA19113 117TH PL SE,RENTON, WA 98058, USA19119 117TH PL SE,RENTON, WA 98058, USA11668 SE 189TH PL,RENTON, WA 98058, USA19135 117TH PL SE,RENTON, WA 98058, USA19141 117TH PL SE,RENTON, WA 98058, USA
PPDB DBDBDB45'WORKVEHICLEWORKZONE←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→
WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTNREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC
CONTROL
PLAN-333ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7040/5540/5540/2525DISTANCEABCD1000' +/-1000' +/-1000' +/-1000' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-250' +/-100' +/-500' +/-350' +/-200' +/-100' +/-SPEEDLONGITUDINAL BUFFER SPACE = BLENGTHÄÄÄÄÄLANEWIDTHMINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)GENERAL NOTE:1.ALL ROW WORK MUST YIELD TO SCHOOLTRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPEDOR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS,DEPART: COMMENCE WORK.CONSTRUCTION TCP NOTES:1. /#+06#+0&4+8'9#;#%%'55#6#..6+/'52. 5+&'9#.-#4''+6*'412'01401612'0#5+&'9#.-+5%.15'&+(#/+0+/7/2#6*%#0016$'/#+06#+0'&/'#574'&(41/2412'46;.+0'14+(%4'#6'&(41/(#%'1(%74$(PEDESTRIAN PATH PROVIDED WHEREREQUIRED)#0&9+..$'MONITORED BY A SPOTTER TO INSUREFLOW AND SAFETY DURING WORK UNLESS OTHERWISENOTED.SPOTTER IS NOT TO CONTROL TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADACOMPLIANCE#..%10641.5'6Ä725+)052#%+0)#0&241%'&74'59+..%10(14/6152'%+(+%#6+10556#6'&+06*'('&'4#./#07#.1070+(14/'&64#((+%%10641.&'8+%'5
/76%&%+6+'5#0&8#4+175/70+%+2#.+6+'5/#;*#8'#.51#&126'&52'%+#.+<'&)7+&'.+0'5(1464#((+%%10641.9+6*+06*'+4,74+5&+%6+10+6+56*'4'52105+$+.+6;1(6*'10Ä5+6'64#((+%%10641.2'4510#.615''+(#0�52'%+#.%10&+6+105':+56(.#))'455*#..$'75'&+0#%%14�%'9+6*9#%ÄÄ+(10.;10'.#0'+512'0+0#&+4'%6+106*#6.#0'5*#..$'#/+0+/7/1(9+&'70.'5552166'4(.#))'45#4'75'&+09*+%*%#5'6*'.#0'%#0$'#/+0+/7/1(TABLE 6C-2SHOULDERWORKBROADWORKAHEAD A
SEFNCOCOMMUNICATIONSPROPOSED UNDERGROUND COAX INSTALLATIONCOMCASTWANG SHORT PLAT19016 116TH AVE SE, RENTON, WA 98058, USAJB# 0000755889
DB DB
DBDBDBWANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21VICINITY MAP19016 116TH AVE SE,RENTON, WA 98058COSTRUCTION SUPERVISORSEFNCOCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-6SITE-PLAN7TYPICAL DETAILS72N/AN/ADESCRIPTION OF WORKTOTALBORE AND PLACE CONDUIT WITH .875 COAX.137LFPLACE NEW RISERPLACE NEW PEDESTALTOTAL:137LFSEFNCO OPE410 TACOMA AVESUMNER, WA 98104PHONE:253-740-1087EMAIL: SEFNCO OPE@SEFNCO.COMVICINITY MAP BEGIN11725 SE 191 ST,RENTON, WA 98058ENDPERMITTINGASHLEY KIEHN253-999-22714610 TACOMA AVESUMNER, WA 98104ASKIEHN@SEFNCO.COMBRANDON MORRIS410 TACOMA AVESUMNER, WA 98104PHONE:253-306-1908EMAIL: BRANDONMORRIS@SEFNCO.COM11740 SE 191 ST,RENTON, WA 98058BEGIN19016 116TH AVE SE,RENTON, WA 98058END
WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21GENERAL NOTES7REVISIONSDATEDESCRIPTIONINITIAL3N/AN/ATHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.GENERAL NOTESRENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.
WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/217REVISIONSDATEDESCRIPTIONINITIAL4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREPROPOSED AERIAL OVERLASH AAPROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED PEDESTALPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS BORE PITN/AN/ALEGEND PROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFMHMHBUILDING OUTLINEFLFOG LINETRENCHPSPLICE CASEPROPOSED AERIAL STORAGEEXISTING AERIAL STORAGE0'0'POTHOLESWSIDEWALK LINEPROPOSED AERIAL STRAND AA
FOCFOCEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WEOPFOCFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOP EOP EOP
EOP EOP EOP SWSWSWSWSW116TH AVE SESE 190TH LN
PRIVATE ROAD
←DRIVEWAY→←DRIVEWAY→
←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←D
R
I
V
E
W
A
Y
→
←DRIVEWAY→
←DRIVEWAY→11464 SE 191ST CT,RENTON, WA 98055, USA11458 SE 191ST CT,RENTON, WA 98055, USA19116 116TH AVE SE,RENTON, WA 98058, USA11527 SE 190TH LN,RENTON, WA 98055, USA19100 116TH AVE SE,RENTON, WA 98058, USA19030 116TH AVE SE,RENTON, WA 98058, USA19021 116TH AVE SE,RENTON, WA 98058, USA19015 116TH AVE SE,RENTON, WA 98058, USA19009 116TH AVE SE,RENTON, WA 98058, USA19003 116TH AVE SE,RENTON, WA 98058, USA11645 SE 189TH PL,RENTON, WA 98058, USA11639 SE 189TH PL,RENTON, WA 98058, USADBDBDBDB92'19016 116TH AVE SE,RENTON, WA 98058, USA12'22'58'12'35'11'POLE 1WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTN7REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN - 1 PLACE NEW RISER.SCOPE OF WORKEND OF ROW DESIGN.CONTINUE TO PRIVATE.1245CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.TIE INTO EXISTING POLE.BORE AND PLACE CONDUIT WITH.875 COAX.321345
14'14'
FOC FOC EOPFOCFOCFOCFOCSWSWSWSWSWSWSWFOC FOC FOCR/W R/W R/WR/WR/WR/WR/WR/WSW SW SW SW
SWSWR/W R/W R/W
EOP EOP
EOP EOPEOPEOPEOPSW←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→
←DRIVEWAY→←DRIVEWAY→PRIVATE ROADPRIVATE ROAD
SE 191ST ST117TH PL SE
19140 117TH PL SE,RENTON, WA 98058, USA19134 117TH PL SE,RENTON, WA 98058, USA11719 SE 191 ST,RENTON, WA 98058, USA11725 SE 191 ST,RENTON, WA 98058, USA11731 SE 191 ST,RENTON, WA 98058, USA11737 SE 191 ST,RENTON, WA 98058, USA11743 SE 191 ST,RENTON, WA 98058, USA11805 SE 191 ST,RENTON, WA 98058, USA11811 SE 191 ST,RENTON, WA 98058, USA11823 SE 191 ST,RENTON, WA 98058, USA11829 SE 191 ST,RENTON, WA 98058, USA11835 SE 191ST, RENTON,WA 98058, USA11806 SE 191 ST,
RENTON, WA 98058, USA
11810 SE 191 ST,
RENTON, WA 98058, USA11752 SE 191 ST,RENTON, WA 98058, USA11748 SE 191 ST,RENTON, WA 98058, USA11740 SE 191 ST,RENTON, WA 98058, USA11744 SE 191 ST,RENTON, WA 98058, USA19113 117TH PL SE,RENTON, WA 98058, USA19119 117TH PL SE,RENTON, WA 98058, USA11668 SE 189TH PL,RENTON, WA 98058, USA19135 117TH PL SE,RENTON, WA 98058, USA19141 117TH PL SE,RENTON, WA 98058, USA
DB DBDBDB45'
54'
27'13'47'9'24'16'16'PP←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTN7REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN - 2 EXISTING PEDESTAL.SCOPE OF WORKEND OF ROW DESIGN.CONTINUE FROM PRIVATE.1234CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.PLACE NEW PEDESTAL AND TIE IN.BORE AND PLACE CONDUITWITH .875 COAX.521345
7REVISIONSDATEDESCRIPTIONINITIAL7TYPICAL DETAILS
WANG SHORT PLAT
19016 116TH AVE SE
RENTON, WA 98058
JB#0000755889REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSVV09/18/21R
DIGALERTNTS(1) 10' NOTCHED STEELCONDUIT SECTIONPROPOSED FIBER15" HDG POLE BRACKETW/ PIPE CLAMP (B2017BY POWER-STRUT OREQUAL) 4" MIN. OFFSETFROM POLETYPE C STEEL-TO-STEELADAPTER. CAP (1) 4"Ø AT 10'.(1) 10' NOTCHED & (1) 10'STEEL CONDUITSECTIONS3'R, 90°STEELEXISTING UTILITY POLETYPE C STEEL-TO-STEEL ADAPTERTYPICAL POLE RISERS (2) 4"ØEXISTING GROUND22'(TYP.)24'(TYP.)HEIGHTVARIES
2"36"
38"(1)-2" HDPEGRADEPAVEMENTBORE @ PAVEMENT