Loading...
HomeMy WebLinkAboutMFP21003751.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21003751 IVR Number: 21003751 Permit Information Permit Name: ExteNet Systems - Fiber - EXTENET - PHASE 2 - SEG 23 - S-007409 P-023596 Address/Location:08/05/2021Application Date:3340403325Parcel Number: 200 SW 19TH ST Permit Type:08/13/2021Issue Date:Franchise Permit Work Class:08/15/2022Expiration Date:Major Utility Job Number: SEG 23 - S-007409 P-023596Franchise Type:Telephone Description: REVISION: ADD VAULT TO THE APPROVED PLAN. SEE ATTACHED SITE PLAN FOR DETAILS. ExteNet Systems Inc. master franchise agreement, ORD 6013 EXTENET PHASE 2 SEG 23 S 007409 P 023596 PROPOSED OPEN TRENCH AND DIRECTIONAL DRILL WEST ALONG SW 19TH ST FROM EXISTING CENTURYLINK VAULT TO EXISTING CENTURYLINK VAULT LOCATION. PULL (1) 144F CABLE THROUGH. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 Applicant MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 MARRIOTT BUSINESS SERVICES PO BOX 92129 SOUTHLAKE , TX 76092 Owner Rachel Fenton Extenet Systems LLC 3030 Warrenville Rd Lisle, IL 60532 Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Monday - Friday 8:00AM - 3:00PM MFP21003751 Scott Warlick CED 11/1/2021 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - TCPS.dwgPERMIT NUMBER: RONLYCONFIDENTIAL/PROPRIETARYSHEET: OF 13Know what'sbelow.before you dig.CallRRENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND SCOPE OF WORK:USE WORK AREA TO INSTALL NEW VAULT, BORE & TRENCHCONDUIT, ACCESS EXISTING VAULT, AND PULL FIBER CABLETHROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND _____NORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMSHORT-TERM STATIONARY WORK ZONE - MULTI-LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ROADWAY)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG SW 19TH ST (ALL LANES)HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLSW 19TH STEAST VALLEY RD 1801 EASTVALLEY RDPARCEL NO.3340403330PARCEL NO.3340400585WORKVEHICLE167W4-2RW20-5RW20-1XX W4-2RW20-5RW20-1X X 50'-100'WORK AREA800 SQ FTSPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONESPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONEL/2L/2W20-1W20-5CW4-2LXXXROADWORKAHEADRIGHTLANECLOSEDAHEADCENTERLANECLOSEDAHEADW4-119LW4-119RW4-119RGRADEGRADE MFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - TCPS.dwgPERMIT NUMBER: RNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMSHORT-TERM STATIONARY WORK ZONE - MULTI-LANE CLOSURE (FOR URBAN ROADWAY)TRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG SW 19TH ST (ALL LANES)HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESCONFIDENTIAL/PROPRIETARYSHEET: OF 23Know what'sbelow.before you dig.CallRRENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.SCOPE OF WORK:USE WORK AREA TO INSTALL NEW BOREPIT, BORE CONDUIT,AND PULL FIBER CABLE THROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND _____SW 19TH STWORKVEHICLEGRADELE VALLEY RD50'-100'WORK AREA200 SQ FTW20-1W20-5RW4-2RXXX200 SW 19TH STPARCEL NO.3340403325PARCEL NO.3340400585W20-1W20-5CW4-2LXXXL/2L/2W4-119RW4-119RW4-119L50'-100'W20-5RW20-1XROADWORKAHEADRIGHTLANECLOSEDAHEADCENTERLANECLOSEDAHEADSPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONESPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONELEGEND FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLMFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - TCPS.dwgPERMIT NUMBER: RNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMTRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG SW 19TH ST (ALL LANES)CONFIDENTIAL/PROPRIETARYSHEET: OF 33Know what'sbelow.before you dig.CallRRENTON TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.SCOPE OF WORK:USE WORK AREA TO INSTALL NEW VAULT, BORE & TRENCHCONDUIT, ACCESS EXISTING VAULT, AND PULL FIBER CABLETHROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND ____SW 19TH STGRADEWORKVEHICLE 50'-100'LIND AVE SW1900 LIND AVESWPARCEL NO.3340400425PARCEL NO.3340403328200 SW 19THSTPARCEL NO.3340403325L/2L/2W4-119RW4-119RPARCEL NO.3340400585W20-1W20-5CW4-2LXXXW20-1W20-5RW4-2RXXXW4-119L50'-100'W20-5RW20-1XROADWORKAHEADRIGHTLANECLOSEDAHEAD CENTERLANECLOSEDAHEADSPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONESPOTTER FLAGGER ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONELEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLWORK AREA550 SQ FTLSHORT-TERM STATIONARY WORK ZONE - MULTI-LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ROADWAY)MFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: R© 2021 Microsoft Corporation © 2021 TomTom SITE LOCATIONSCOPE OF WORK:Know what'sbelow.before you dig.CallRS H E E T 4 CONFIDENTIAL/PROPRIETARYSHEET: OF 18ENDADDRESS: 200 SW 19TH ST, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANSSHEET INDEX1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-6. DESIGN VIEWS A-C7. UNDERGROUND TYPICALS8. SITE PHOTOGRAPHSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMS H E E T 5 STARTNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMS H E E T 6 PROPOSED OPEN TRENCH AND DIRECTIONALDRILL WEST ALONG SW 19TH ST FROMEXISTING CENTURYLINK VAULT TO EXISTINGCENTURYLINK VAULT LOCATION. PULL (1)144F CABLE THROUGH.This permit is for Major construction work in the ROW and will be billed at an additional$60/HR for inspections. After hours and weekend work will be billed at $125/HRPOTHOLE ALL EXISTING UTILITIESRESTORATION PER CITY OF RENTON STANDARDSMFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 28#F#F#F##LEGENDMFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 38The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: RONLY0+00 0+001+002+001+00-1+00 CONFIDENTIAL/PROPRIETARYSHEET: OF 48Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #8 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 5DESIGN VIEW A 1'2'3'4'5'6'10'7'8'9'11'HORIZ. SCALE: 1"=20'-0"VERT. SCALE: 1"=5'-0"EXISTING GRADEDESIGN PROFILECONSTRUCTION NOTESRESTORATION NOTESPOTHOLE UTILITY CROSSING PRIOR TO BORE. MAINTAINMINIMUM 2' VERTICAL CLEARANCE AT THE CROSSING FROMEXISTING UTILITIES.4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF RENTON STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF RENTON STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.SW 19TH STEAST VALLEY RD 1801 EASTVALLEY RDPARCEL NO.3340403330PARCEL NO.3340400585283'30'37'216'18'18'13'12'12'16760'11'37'12'18'18'12'12'13'2134ARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.DRESTORE ASPHALT PER CITY OF RENTONSTANDARDS.ERESTORE CURB & GUTTER PERCITY OF RENTON STANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.15'14'22'3'7'8'8'9'12'246'15' 24'STA. 0+00STA. 1+00STA. 2+00EX.4".ELECTR. EX.8".STORM2.0DE1AAGD2.8'MFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: R3+004+005+006+00CONSTRUCTION NOTESPOTHOLE UTILITY CROSSING PRIOR TO BORE. MAINTAINMINIMUM 2' VERTICAL CLEARANCE AT THE CROSSING FROMEXISTING UTILITIES.CONFIDENTIAL/PROPRIETARYSHEET: OF 58Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #8 FOR SITE PHOTOGRAPHS.DESIGN VIEW B MATCH TO SHEET 6 1801 EASTVALLEY RDPARCEL NO.3340403330PARCEL NO.3340400585MATCH TO SHEET 4SW 19TH STE VALLEY RD 200 SW 19TH STPARCEL NO.334040332562'12'36'14'18'18'12'12'13'445'14'22'321'1'2'3'4'5'6'10'7'8'9'11'HORIZ. SCALE: 1"=20'-0"VERT. SCALE: 1"=5'-0"EXISTING GRADEDESIGN PROFILESTA. 4+00STA. 5+00STA. 6+00STA. 3+0024PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF RENTON STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF RENTON STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.49'11'11'D31RESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.DRESTORE ASPHALT PER CITY OF RENTONSTANDARDS.ERESTORE CURB & GUTTER PERCITY OF RENTON STANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.AEGDMFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: R7+008+009+0010+00CONFIDENTIAL/PROPRIETARYSHEET: OF 68Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #8 FOR SITE PHOTOGRAPHS.DESIGN VIEW C CONSTRUCTION NOTESRESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.DRESTORE ASPHALT PER CITY OF RENTONSTANDARDS.ERESTORE CURB & GUTTER PERCITY OF RENTON STANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.POTHOLE UTILITY CROSSING PRIOR TO BORE. MAINTAINMINIMUM 2' VERTICAL CLEARANCE AT THE CROSSING FROMEXISTING UTILITIES.4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF RENTON STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF RENTON STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.PARCEL NO.3340400585MATCH TO SHEET 5 LIND AVE SW 200 SW 19THSTPARCEL NO.334040332565'11'36'18'17'18'12'12'12'SW 19TH STPARCEL NO.33404033281900 LIND AVESWPARCEL NO.33404004254115'180'1 9 ' 7'3' 29' 5' 14' 23' 5'EAAG1'2'3'4'5'6'10'7'8'9'11'HORIZ. SCALE: 1"=20'-0"VERT. SCALE: 1"=5'-0"EXISTING GRADEDESIGN PROFILESTA. 7+00STA. 8+00STA. 9+00STA. 10+001' EX.8".WATER EX.8".WATER EX.8".STORM EX.8".STORM2.2'1.9'D213D2.2'2.4'MFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: RUNDERGROUND TYPICALSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 78TYPICAL TRENCH IN SOIL DETAILSCALE: NTSEXISTING GROUNDWARNING TAPEBACKFILL(8" LAYERS)6" MIN.12"36" MIN. DEPTH4"BACKFILL(COMPACTED @ 90%)HDPE DUCTCLEAN BACKFILLBACKFILL(COMPACTED EARTH @ 90%)24"12"6"6"3' MIN.PANEL WIDTH PER PLAN12"MIN.12"MIN.3" HMA (CL 12") (MATCHEX. IF GREATER)EX. ASPHALT SURFACE11" HMA (CL 12" OR 1)6" MIN. COMPACT MINERALAGGREGATE TYPE 2COMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGTYPICAL ASPHALT TRENCH DETAILSCALE: NTSTYPICAL CONCRETE TRENCH DETAILSCALE: NTS24"12"6"6"EX. CONCRETEREPLACE EX. CURBPER STD PLAN 410C6" MIN. TYPE 2 CRUSHEDROCKCOMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGPANEL WIDTH PER PLAN12"MIN.12"MIN.ZONE OF INFLUENCE12" PCC CLASS 6.5 (CL 1-1/2")233LA VAULT DETAILSCALE: NTSVAULTNo. 233-BLMANHOLE COVERAND FRAMELOADING: BUILT TOAN H2O RATING UPTO 150 KIPMFP21003751 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 23NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 200 SW 19TH ST RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 23 - PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 88CONSTRUCTION NOTESPHOTO #1: FACING NORTHEAST IN THE MIDDLE OF SW 19TH STPHOTO #2: FACING NORTHEAST ON NORTH SIDE OF SW 19TH ST4PROPOSED BORE (1) 4" CONDUIT, REPAIR SURFACE AS PERCITY OF RENTON STANDARDS. PULL (3) 1.25 INNERDUCTAND (1) 144F CABLE THROUGH.3PROPOSED (1) 4X6 BORE PIT. REPAIR SURFACE AS PER CITYOF RENTON STANDARDS.2PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.1PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL (3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.114312MFP21003751