HomeMy WebLinkAboutSTAFF COMMENTS PRE21-000374
PREAPPLICATION MEETING
Malik Short Plat
3726 Lake Washington Blvd N, Renton, WA 98056
PRE21-000374
CITY OF RENTON
Department of Community & Economic Development
November 4, 2021
Contact Information:
Planner: Andrew Van Gordon, 425.430.7286, avangordon@rentonwa.gov
Public Works Plan Reviewer: Yong Qi, 425.430.7439, yqi@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@rentonrfa.org
Building Department Reviewer: Rob Shuey, 425.430.7235, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the assigned planner to have the documents pre-
screened.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Community & Economic Development Administrator, Public Works Administrator, and
City Council).
M E M O R A N D U M
DATE: October 19, 2021
TO: Andrew Van Gordon, Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Malik Short Plat
1. The fire flow requirements for a single-family home is 1,000 gpm minimum for dwellings
up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square
feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is
required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to
1,500 gpm. It appears that there are existing fire hydrants within 300-feet of all proposed
homes, no new fire hydrants required.
2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit.
This fee is paid at building permit issuance. Credit will be granted for any existing homes that
are removed or retained.
3. Fire department apparatus access roadways are adequate with the existing city streets.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: November 04, 2021
June 20, 2011
TO: Andrew Van Gordon, Planner
FROM: Yong Qi, Civil Engineer III
SUBJECT: Malik Short Plat
3726 Lake Washington Blvd N, Renton, WA
PRE21-000374
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel #
3342700386. The following comments are based on the pre-application submittal made to the City of
Renton by the applicant.
WATER
1. The project is within the City of Renton’s water service area in the Kennydale 308 hydraulic
zone.
2. There is an existing ¾ -inch water meter serving the existing site (facility ID number LAT -
000358).
3. There is an existing 8-inch ductile iron water main (see City water project plan no. W- 043101) in
N 38th Street, which can deliver a maximum flow rate of 2,000 gallon per minute. There is an
existing 8-inch ductile iron water main (see City water project plan no. W- 035304) in Lake
Washington Blvd N, which can deliver a maximum flow rate of 2,500 gallon per minute
The static water pressure is approximately 106 psi at ground elevation 62 feet.
4. There is one fire hydrant to the north of the project site (Facility ID No. HYD-N-00122), which is
in the northeast landscaping strip at the intersection of N 38th St and Lake Washington Blvd N.
Please refer to the Renton Regional Fire Authority (RRFA) for fire hydrant requirements. The
hydrant is within 300 feet of the property and it can deliver 1,000 gpm.
5. Based on the review of project information submitted for the pre-application meeting, in order
to provide domestic and fire protection service to the development, developer constructed
improvements will include but are not limited to the items that follow:
a. Installation of a 1-inch water service and domestic water meter is required for the new Lot
A. The meter will be installed by City forces and a water meter permit is required. The sizing
Malik Short Plat PRE21-000374 Page 2 of 5
November 04, 2021
2
of the meter and of the private service line to the building shall be in accordance with the
most recent edition of the Uniform Plumbing Code (UPC).
b. Installation of pressure-reducing valve downstream of the water meter as required by the
UPC because the water supply pressure is over 80 psi.
c. Installation of an additional hydrant and/or fire sprinkler system if the building is over 3,600
sq-ft.
6. A conceptual utility plan will be required as part of the land use application for the subject
development.
7. The development is subject to applicable water system development charges (SDC’s) fee and
meter installation fees based on the number and size of the meters for domestic uses. Current
fees can be found in the 2021 Development Fees Document on the City’s website. Fees will be
charged based on the rate at the time of construction permit issuance.
a. The SDC fee for water is based on the size of the new domestic water meter(s) to serve the
project. The current water fee is $ 4,450 per 1-inch meter
b. Water service installation charges for each proposed domestic water service is applicable.
Water service installation is $2,875 per 1-inch service line
c. Drop-in meter fee is $ 460 per 1-inch meter
d. A credit will be applied to the existing service if abandoned.
e. The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=1&repo=CityofRe
nton
SEWER
1. Sewer service is provided by City of Renton.
2. There is an existing 8’’ concrete gravity wastewater main located within N 38th St (see record dwg:
S-014204). The existing house is connected to a 6’’ concrete sewer stub (Facility ID No. SLAT -
03959). There is also an existing 8’’ concrete gravity wastewater main located within Lake
Washington Ave N (see record dwg: S-014206), and a 6’’ concrete sewer stub (Facility ID No. SLAT-
03927) to the west of the project site.
3. The two existing sewer stubs shall be CCTV’d and, if found to be in acceptable condition, lined.
Individual new sewer stubs from the sewer main and individual new side sewers are required for
each lot if the existing sewer stubs are not in acceptable condition. All new sewer stubs shall
conform to the standards in RMC 4-6-040 and City of Renton Standard Details.
4. A conceptual utility plan will be required as part of the land use application for the subject
development.
5. The development is subject to a wastewater system development charge (SDC) fee. SCD fee for
sewer is based on the size of the new domestic water to serve the project. Current fees can be
found in the 2021 Development Fees Document on the City’s website. Fees will be charged
based on the rate at the time of construction permit issuance.
a. The current sewer fee is $ 3,450 per 1-inch meter.
b. Final determination of applicable fees will be made after the water meter size has been
determined.
c. The developer will receive a credit for the existing homes if demoed.
d. The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=1&repo=Cityo
fRenton
Malik Short Plat PRE21-000374 Page 3 of 5
November 04, 2021
3
SURFACE WATER
1. There is a City of Renton 12-inch concrete stormwater main (Facility ID No. 151325) and virtual
drainline in the south side of N 38th St along the north frontage of the site. Within the east side
of Lake Washington Blvd next to the project site, there are City of Renton 12-inch concrete
stormwater main (Record Dwg: R-330709) and associated two catch basins (Facility ID No.
504734 and No. 132915).
2. Refer to Figure 1.1.2.A – Flow Chart in the 2017 City of Renton Surface Water Manual (2017
RSWDM) to determine what type of drainage review is required for this site. A drainage study
complying with the 2017 RSWDM will be required. Based on the City’s flow control map, this site
falls within the Peak Rate Flow Control Standard area (matching existing site conditions). The
site is located in the East Lake Washington – Renton basin and West Kennydale sub basin.
3. Drainage report and drainage plans based on 2017 RSWDM are required to be provided.
4. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant
will be required to provide basic water quality treatment. Any proposed detention and/or water
quality vault shall be designed in accordance with the 2017 RSWDM. Separate structural plans
will be required to be submitted for review and approval under a separate building permit for
the detention and/or water quality vault. Special inspection from the building department is
required.
5. Any new storm conveyance installed on or off-site shall be designed and sized in accordance
with standards found in Chapter 4 of the 2017 RSWDM and shall account for the total upstream
tributary area, assuming developed conditions for onsite tributary areas and existing conditions
for any offsite tributary areas.
6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the
new runoff created by this development to the maximum extend feasible. On-site BMPs shall be
evaluated as described in Section C.1.3 of the 2017 RSWDM. A preliminary drainage plan,
including the application of on-site BMPs, shall be included with the land use application, as
appliable to the project. The final drainage plan and drainage report must be submitted with the
utility construction permit construction.
7. The site is located in the Moderate Landslide Hazard and Regulated Slopes area.
8. A geotechnical report for the site is required and shall be submitted with the land use application.
Information concerning the soils, geology, drainage patterns, vegetation present, water table and
soil permeability, with recommendations of appropriate on-site BMP options with typical designs
for the site from the geotechnical engineer, shall be submitted with the application. The
geotechnical report should include an on-site infiltration test to clearly show if the site is suitable
or unsuitable for infiltration.
9. Erosion control measures to meet the City requirements shall be provided.
10. All work proposed outside of the applicant’s property will require a permanent drainage
easement to be provided to the City and a temporary construction easement prior to any
permits being issued.
11. The current City of Renton Surface Water Standard Plans that shall be used in all drainage
submittals. The current City of Renton Standard details are available online at the City of Renton
website:
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton.
12. The development is subject to a surface water system development charge (SDC) fee. Fees will
be charged based on the rate at the time of construction permit issuance.
a. The 2021 Surface water system development fee is $0.80 per square foot of new
impervious surface, but no less than $2,000.00.
Malik Short Plat PRE21-000374 Page 4 of 5
November 04, 2021
4
b. The full schedule can be found at:
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=1&repo=Cityo
fRenton
TRANSPORTATION
1. In accordance with RMC 4-6-060, if the site improvements and/or proposed building additions
exceed an overall valuation is greater than $150,000, the project site(s) shall be required to meet
the City’s Complete Streets Standards.
a. N 38th St is classified as a residential access street, with an existing right-of-way (ROW) width
of approximately 50 feet with an existing paved width of approximately 26 feet. To meet the
City’s complete street standards for Residential Access streets, a minimum ROW width of 53
feet is required. Per RMC 4-6-060, half street improvements as taken from the ROW
centerline will be required and include a minimum 13-foot paved road, 0.5 feet of cub and
gutter, an 8-foot planting strip, and 5-foot sidewalk, street trees and storm drainage
improvements, 1.5’ dedication would be required for this project on N 38th St based on final
survey.
b. Lake Washington Blvd N is classified as Collector Arterial, with an existing right-of-way
(ROW) width of approximately 60’. To meet the City’s complete street standards for
Collector Arterial per RMC 4-6-060, a minimum ROW width of 83’ with 2 lanes is required.
Per RMC 4-6-060, half street improvements as taken from the ROW centerline will be
required and include a minimum 23-foot paved road, 0.5 feet of cub and gutter, an 8-foot
planting strip, and 8-foot sidewalk, 2’ of clearance, street trees and storm drainage
improvements, 11.5’ dedication would be required for this project on Lake Washington Blvd
N depending on final survey.
2. Refer to City code 4-4-080 regarding driveway regulations:
a. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide slotted drains at
the lower end with positive drainage discharge to restrict runoff from entering the garage.
b. The maximum width of a single loaded garage driveway is 9-feet and the maximum width of
a double loaded garage driveway is 16-feet. If a garage is not present, the maximum driveway
width is 16-feet.
c. Driveways shall not be closer than 5-feet to any property line.
3. Undergrounding of all exiting utilities is required on all frontages per RMC 4-6-090.
4. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay
Requirements.
5. Street trees are required to meet current city standards.
6. The development is subject to transportation impact fees. Fees will be charged based on the rate
at the time of construction permit issuance.
a. Unless noted otherwise in the Fee Schedule, for a single-family dwelling, the 2021
transportation impact fee is $10,861.69.
b. The current property contains one single family home, the developer will receive one credit
for the existing home.
Malik Short Plat PRE21-000374 Page 5 of 5
November 04, 2021
5
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e., electrical, phone, and cable services, etc.) along property
frontage or within the site must be underground. The construction of these franchise utilities must be
inspected and approved by a City of Renton inspector.
2. Adequate separation between utilities as well as other features shall be provided in accordance with
code requirements:
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
3. All civil construction permits for utility and street improvements will require separate plan submittals.
All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare
the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan
submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
4. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall
be on separate sheets.
5. Additional Building Permit Applications will be required for the following:
a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040.
b. Detention vaults for storm water flow control.
c. Demo of any existing structures on the project site(s).
6. Fees quoted in this document reflect the fees applicable in the year 2021 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to the
permit type. Please visit www.rentonwa.gov for the current fee schedule.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: November 4, 2021
TO: Pre-Application File No. 21-000374
FROM: Andrew Van Gordon, Associate Planner
SUBJECT: Malik Short Plat – 3726 Lake Washington Blvd N (Parcel number
3342700386)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, and City Council). Review comments may also need to be
revised based on site planning and other design changes required by City staff or made by the
applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal
Code. The Development Regulations are available online at
https://www.codepublishing.com/WA/Renton/.
Project Proposal: The subject property is a corner lot located at 3726 Lake Washington Blvd N
(Parcel number 3342700386). The parcel has public street frontage on both Lake Washington Blvd
N and N 38th St and is located within the R-6 Zone. The site area is approximately 15,577 square
feet (0.36 acre) and is currently improved with a detached dwelling. The proposal is to subdivide
the property into 2 lots. Access to the site appears to be proposed via residential driveways off of
either Lake Washington Blvd N or N 38th St. The proposed lot size, based on the provided drawings,
for Lot A is approximately 6,577 square feet and approximately 7,965 square feet for Lot B.
Current Use: The property is currently developed with a detached dwelling which is proposed to
be removed.
Zoning/Density Requirements: The subject property is located within the Residential-6 (R-6)
zoning classification. The density range allowed in the R-6 zone is a minimum of 3.0 to a maximum
of 6.0 dwelling units per net acre. The Residential Medium Density Land Use designation is
intended to implement the R-6 zone. The R-6 zone is established for detached dwellings.
Development within the R-6 zone is intended to be residential at moderate density. Detached
dwelling units are permitted within the R-6 zone.
Density: The area of public and private streets and critical areas would be deducted from the
gross site area to determine the “net” site area prior to calculating density. In order to calculate
the proposed density of the project, any area of public road, private driveway/easement, and/or
critical area dedication must be known. All fractions which result from net density calculations
shall be truncated at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations
Malik Short Plat, PRE21-000374
Page 2 of 5
November 4, 2021
for minimum or maximum density that result in a fraction that is 0.50 or greater shall be rounded
up to the nearest whole number. Those density calculations resulting in a fraction that is less than
0.50 shall be rounded down to the nearest whole number. Based on the gross land area of 15,577
square feet, the 2-lot proposal arrives at a gross density of approximately 5.56 du/ac (2 lots / 0.36
gross acres = 5.56 du/ac). Based on the gross density of 5.56 du/ac, the subject site would meet
the density requirements of the zone. Flag lots are only permitted to achieve minimum density;
at current density a flag lot would not be permitted for this project. The applicant would be
required to demonstrate compliance with the net density requirements of the zone at the time
of formal application, after deduction of ROW dedication along N 38th St (approximately 1.5-
feet) and Lake Washington Blvd. (approximately 4.5-feet) and/or critical areas.
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Residential Zoning Designations” effective at the time of complete application
(noted as “R-6 standards” herein).
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-6 zone is 7,000
square feet for parcels being subdivided. Minimum lot width is 60 feet and 70 feet for corner lots;
minimum lot depth is 90 feet. Please note that for short plats of parcels smaller than one acre,
one parcel may be allowed to be smaller than the required minimum lot size, if all other parcels
meet the required minimum lot size standard of the zone. In the R-6 zone, one parcel may be
allowed to be six thousand two hundred (6,250) square feet.
Based on the pre-application submittal provided by the applicant and with the exception of the
flag lot layout, proposed lots appear to comply with minimum lot size, width, and depth
requirements of the zone. Dedication along Lake Washington Blvd N and N 38 th St will be
required; please keep in mind that minimum lot width does not include dedication areas. The
applicant will need to demonstrate compliance with the minimum lot size, width and depth
requirements of the zone (following deduction of required ROW dedication), based on the
definitions of lot size, width, and depth (RMC 4-11-120), prior to the City accepting the formal
land use application.
Building Standards – The R-6 standards allow a maximum building coverage of 40% of the lot area.
The maximum impervious coverage in the R-6 zone is 55%. The maximum wall plate height is
restricted to 24 feet, and the buildings shall be not more than two stories. Roofs with a pitch equal
to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate
height; common rooftop features, such as chimneys, may project an additional four (4) vertical
feet from the roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.) shall not
extend above the maximum wall plate height unless the projection is stepped back one-and-a-
half (1.5) horizontal feet from each façade for each one (1) vertical foot above the maximum wall
plate height. The maximum wall plate height for detached accessory structures is 12 feet. The
gross floor area must be less than that of the primary structure. Accessory structures are also
included in building lot coverage calculations. New detached dwellings would need to comply
with the maximum building coverage, impervious surface requirements, and building height
regulations of the zone at the time of building permit review.
Setbacks – Setbacks are the minimum required distance between the building footprint and the
property line. The required setbacks for the R-6 zone are: Front yard: 25 feet for the primary
structure; Rear yard: 25 feet; Side yards: combined 15 feet with not less than five feet on either
side; and secondary front yards: 25 feet. Side yard along a street is defined as the yard
requirement that is neither a front yard nor a rear yard, yet it abuts a street right-of-way or private
Malik Short Plat, PRE21-000374
Page 3 of 5
November 4, 2021
street. New detached dwellings must comply with the secondary front yard setback requirements.
Compliance with required setbacks for the new detached dwellings would be verified at the time
of building permit application.
Access/Parking: Access to the individual lots appears to be proposed via residential driveways
off of either Lake Washington Blvd N or N 38th St. Each lot is required to accommodate off street
parking for a minimum of two vehicles. The maximum width of single loaded garage driveways
shall not exceed 9 feet and double loaded garage driveways shall not exceed 16 feet. Maximum
driveway slopes shall not exceed fifteen percent (15%); provided, that driveways exceeding eight
percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to
restrict runoff from entering the garage/residence or crossing any public sidewalk. Detached
dwellings are required to provide a minimum of two (2) parking spaces per dwelling unit. As
mentioned previously, the flag lot currently proposed for Lot B would not be permitted.
Compliance with driveway and parking standards would be verified at the time of building
permit review.
Landscaping: With the exception of critical areas, all portions of the development area not
covered by structures, required parking, access, circulation or service areas, must be landscaped
with native, drought-resistant vegetative cover. The minimum on-site landscape width required
along street frontages is 10 feet and shall contain trees, shrubs, and landscaping. Street trees in
the ROW planter will also be required. Landscaping may include hardscape such as decorative
paving, rock outcroppings, fountains, plant containers, etc. Minimum planting strip widths
between the curb and sidewalk are established according to the street development standards of
RMC 4-6-060. Street trees and, at a minimum, groundcover are to be located in this area when
present. Street trees shall be planted in the center of the planting strip between the curb and the
sidewalk at the following intervals; provided, that, where right-of-way is constrained, irregular
intervals and slight increases or decreases may be permitted or required. Additionally, trees shall
be planted in locations that meet required spacing distances from facilities located in the right-
of-way including, but not limited to, underground utilities, street lights, utility poles, traffic signs,
fire hydrants, and driveways; such spacing standards are identified in the City’s Approved Tree
List. Generally, the following spacing is required: i. Small-sized maturing trees: thirty feet (30') on
center; ii. Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized maturing
trees: fifty feet (50') on center. A conceptual landscape plan shall be provided with the land use
application as prepared by a licensed Landscape Architect, a certified nurseryman or other
certified professional.
Storm drainage facilities are required to comply with the minimum 15-foot perimeter
landscaping strip on the outside of the fence unless otherwise determined through the site plan
review or subdivision review process. Please refer to landscape regulations RMC 4-4-070 for
further general and specific landscape requirements.
Significant Tree Retention: Staff review of aerial image of the site identifies mature trees on the
site. If significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods)
are proposed to be removed, a tree inventory and a tree retention plan along with an arborist
report, tree retention plan and tree retention worksheet shall be provided with the formal land
use application as defined in RMC 4-8-120. The tree retention plan must show preservation of at
least 30% of significant trees. The Administrator may authorize the planting of replacement trees
on the site if it can be demonstrated to the Administrator's satisfaction that an insufficient
number of trees can be retained. Please refer to Tree Retention and Land Clearing Regulations
RMC 4-4-130 for further general and specific tree retention and land clearing requirements.
Malik Short Plat, PRE21-000374
Page 4 of 5
November 4, 2021
In addition to retaining 30% of existing significant trees, each new lot would be required to provide
a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected trees that
do not contribute to a lot's required minimum tree density shall be held in perpetuity within a
tree protection tract.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on
slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their
associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen
inches (18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; Other
significant native evergreen or deciduous trees; and Other significant non- native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods
are used as part of an approved enhancement project within a critical area or its buffer.
The Administrator may require independent review of any land use application that involves tree
removal and land clearing at the City's discretion.
If staff determines that the trees cannot be retained, replacement trees, with at least a 2-inch
caliper or an evergreen at least 6 feet tall, shall be planted at a rate of 12 caliper inches of new
trees to replace each protected tree removed. A formal tree retention plan prepared by an
arborist or landscape architect would be reviewed at the time of the Short Plat application.
Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project,
the location must be designated on the landscape plan or grading plan. A fence and/or wall detail
should also be included on the plan. A retaining wall that is 4 feet or taller, as measured by the
vertical distance from the bottom of the footing to the finish grade at the top of the wall requires
a building permit. A fence shall not be constructed on top of a retaining wall unless the total
combined height of the retaining wall and the fence does not exceed the allowed height of a
standalone fence. For more information about fences and retaining walls refer to RMC 4-4-040.
Critical Areas: According to COR Maps, there is a moderate landslide hazard area and slopes
exceeding 25% and 40% grade. It is the applicant’s responsibility to ascertain whether any critical
areas are present on the site. A geotechnical report prepared by a licensed professional engineer
would be required with the formal land use application assessing slopes and hazard areas.
Environmental Review: Short Plats are generally exempt from State Environmental Policy Act
(SEPA) review. However, the project may be subject to Environmental Review, in accordance with
RMC 4-9-070 H.3., if it is determined that critical areas are located on the property.
Permit Requirements: The proposal would require administrative short plat approval and may
require an Environmental Review. The application would be reviewed within an estimated time
frame of six to eight weeks. The 2021 fees, if Environmental Review is necessary, would total
$7,360.50 ($5,410 Short Plat + $1,600 SEPA + $350.50 Technology Fee (5%) = $7,350.50). Each
modification request is $260.00. A 5% technology fee added to the total cost of the reviews would
also be assessed at the time of land use application. All fees are subject to change. Detailed
information regarding the land use permit application submittal requirements can be found on
the Short Plat Submittal Requirements checklist. Other informational applications and handouts
can be found on the City’s Digital Records Library. The City requires electronic plan submittal for
Malik Short Plat, PRE21-000374
Page 5 of 5
November 4, 2021
all applications. Please refer to the City’s Electronic File Standards. A Final Short Plat application,
and it’s associated fee, will be required following construction of the subdivision’s infrastructure.
Public Information Sign: Public Information Signs are required for all Type II and Type III Land Use
Permits as classified by RMC 4-8-080. Public Information Signs are intended to inform the public
of potential land development, specific permits/actions being considered by the City, and to
facilitate timely and effective public participation in the review process. The applicant must follow
the specifications provided in the public information sign handout. The applicant is solely
responsible for the construction, installation, maintenance, removal, and any costs associated
with the sign.
Fees: In addition to the applicable building and construction fees, impact fees would be required.
The fee in effect at the time of permit issuance will apply. The 2021 impact fees are as follows:
• A Transportation Impact Fee based on $10,861.69 per each new detached dwelling unit.
• A Parks Impact Fee based on $2,914.99 per each new detached dwelling unit.
• A Fire Impact fee of $829.77 per each new detached dwelling unit.
• Renton School District Impact Fee is $7,681.00 per each new detached dwelling unit.
A handout listing Renton’s development-related fees is available on the City of Renton website
for your review.
Next Steps: When the formal land use application materials are complete, the applicant shall have
the application materials pre-screened prior to submitting the complete application package.
Please contact Andrew Van Gordon, Associate Planner at avangordon@rentonwa.gov or 425-430-
7312 for an appointment.
Expiration: Upon approval, the Short Plat is valid for five years with a possible one year extension
(RMC 4-7-070M). It is the responsibility of the owner to monitor the expiration date.